Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹31.2 L+₹3.3 L (11.8%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹33.0 L+₹5.0 L (18.0%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹37.7 L+₹9.7 L (34.8%)Rejected-Finance | L4 | Rejected-Finance Not lowest |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
7 Oct 2020, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIRS/ REPLACEMENT OF U/S INTRNL ELECTRICAL FITTINGS, SPLIT/WINDOW ACs, COOLERS AND ITS ACCESSORIES, REWINDING OF CEILING/EXHAUST FANS RPLCMNT OF U/S DBS/MCCBS/MCBs, BLDG SECURITY LIGHTS, OTHER ALLIED WRKS AT DMRL, ATC, DLRL AND ADJOINING AREA, HYD
2020_MES_376482_1
GE I KBAGH TOKEN 56 OF 2020 2021
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹98,000
Yes
19 Nov 2020
10 Sept 2020
10 Oct 2020
10 Sept 2020
7 Oct 2020
24 Sept 2020
11 Sept 2020 - 17 Sept 2020
Amount
M&L for One light point / fan point controlled by one 5 Amps one way switch by using point wiring using 1.5 sqmm nominal cross sectional area copper conductor multistranded, PVC insulated unsheathed cables in and including new PVC conduits and fittings, fixed on surface of walls or concealed or above ceilings terminated in existing sunk type pressed steel terminal switch boxes, including new 3 mm thick bakelite sheet top cover fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multi-multistranded copper conductor, green PVC insulated unsheathed earth wire and connecting to earth dolly including taking down old point wiring including all fittings & fixture complete all as directed.
All as per item No. 01 here-in-before but for One 3 pin 5 Amps switch socket outlet point on independent board.
M&L for One light point / fan point controlled by one 5 Amps one way switch by using point wiring using 1.5 sqmm nominal cross sectional area copper conductor multistranded, PVC insulated unsheathed, FR cables drawn in existing PVC Casing Capping or PVC conduits and fittings, fixed on surface/concealed in walls/ceilings terminated in existing sunk type pressed steel terminal switch boxes, including new 3 mm thick bakelite sheet top cover fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multi-multistranded copper conductor, FR, green PVC insulated unsheathed earth wire and connecting to earth dolly including taking down old point wiring, making good disturbed surfaces complete all as directed.
All as per srl item No. 03 here-in-before but for One 3 pin 5 Amps switch socket outlet point on independent board
M&L for point wiring using 2.5 sqmm nominal cross sectional area copper conductor multistranded, PVC insulated unsheathed, including new PVC conduits and fittings, fixed on surface of walls or concealed or above ceilings, terminated in existing sunk type pressed steel terminal switch boxes, including new 3 mm thick bakelite sheet top cover fitted with Chromium plated brass screws & washers and 2.5sqmm nominal cross sectional area multi-multistranded copper conductor, FR, green PVC insulated unsheathed earth wire and connecting to earth dolly including taking down old point wiring, making good disturbed surfaces complete all as directed for 15 Amps socket outlet.
All as per srl item No. 05 here-in-before drawn in existing Conduits complete all as directed.
M&L for sub main wiring complete with 4 runs of 4 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawn through surface or concealed in and including PVC conduit of appropriate size and connecting terminal ends including provision of 2 runs of 4 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor for earth continuity conductor and connecting to earth dolly including taking down old unserviceable sub main wiring complete all as directed. Note: 6 runs of 4 Sqmm conductor and one run PVC conduit shall be measured as one length.
All as per srl item No.7 here-in-before but with 4 runs of 6 sqmm and 2 runs of 6 sqmm, complete all as directed. Note : 6 runs of 6 Sqmm cable and one run PVC conduit shall be measured as one length.
All as per srl item No. 7 here-in-before but with 4 runs of 10 sqmm and 2 runs of 10 sqmm, complete all as directed. Note: 4 runs of 10 Sqmm cable, 2 runs of 10 Sqmm earth continuity conductor and one run PVC conduit shall be measured as one length.
M&L for sub main wiring complete with 2 runs of 4 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawn through surface or concealed in and including PVC conduit of appropriate size and connecting terminal ends including provision of 1 run of 4 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor for earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring complete all as directed. Note: 2 runs of 4 Sqmm cable, 1 run of 4 Sqmm earth continuity conductor and one run PVC conduit shall be measured as one length. Makes for item No 1 to 10 : PVC wires - KEI/ RPG/ INDOASIAN/ FINOLEX/ GLOSTER/ HAVELLS PVC conduits/Casing& caping : - FINOLEX/ MODI/ AVON PLAST /SUDHAKAR/ PRESTO PLAST/ PRECISSION/ BAJAJ/ P&A
S&F switch piano one way 5 Amps 240 Volts complete all as directed.
S&F switch socket 3 pin 5 Amps complete all as directed.
S&F switch socket 5 pin 15 Amps multipurpose type complete all as directed.
S&F switch 5 pin 15 Amps multipurpose type complete all as directed by Engr-in-charge. Make for Item No. 11 to 14 :- ANCHOR/LEADER /STANDARD/ KONE/ HAVLEES/ INDOASIAN
S&F sheet metal enclosure DB concealed/mounted on wall, TP vertical type 08 ways complete with incomer MCCB 3 Pole 125 Amp, 16 KA, 200 Amp rated bus bar capacity double door vertical type including taking down old unserviceable MCCB distribution board blanking plates including making good disturbed surfaces complete all as directed.
All as per item No.15 here-in-before but MCCB DB, Double Door, TP vertical type 04 ways complete with incomer MCCB 3 Pole 100 Amp, 10KA, TP complete all as directed. Make for item Nos.15 & 16 :- ABB/ SIEMENS/ LEGRAND/ L&T/C&S/ SCHNEIDER/ HAVELLS
S&F in repairs electronic choke suitable for 28 watts fluorescent tube light fittings including taking down old unserviceable choke, complete all as directed.
S&F in repairs electronic choke suitable for 36/40 watts fluorescent tube light fittings including taking down old defective choke, complete all as directed.
S&F of LED 18 watts, 4 pin, (PL-L lamp) retrofit by taking down unserviceable lamp from the fitting from any height and fixing complete all as directed.
Earthing with GI earth plate electrode 600x600x6 mm buried directly in ground vertically to a depth of not less than 2.25 mtrs below ground level with the top edge not less than 1.5 mtrs below ground level connected to GI earth strip of size 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by40mm dia GI pipe light grade including necessary excavation and earthwork, PCC 1:3:6 type C2 (using 40mm graded stone aggregate) for earth pit and RCC covers 1:2:4 type B1 (using 20mm graded stone aggregate) with 8mm dia TMT bars @ 100mm C/C both way, 20mm dia GI watering pipe medium grade, funnel, mesh, salt, charcoal complete and frame work complete all as shown in electrical plate No. 3 of MES Sch `A' Part - I complete all as directed. Note:- GI strip beyond 7.5M length shall be measuerd and paid separately.
S&F sheet metal AC earth plug and socket of 3 pin with MCB SP 5 to 30 Amps 240 Volts, including taking down old one, complete all as directed by Engr-in-charge.
S&F sheet metal AC 3 Phase earth plug and socket of 3 pin with neutral with and including MCB TPN 32Amps operating on 415V, 50Hz AC supply, including taking down old one, complete all as directed.
S&F of MCB SP 5-32 Amps capacity including taking down unserviceable one complete all as directed.
S&F in repairs of MCB SPN of 40Amps capacity complete all as directed.
S&F isolator 4 pole 100 Amps 415 Volts including taking down existing unserviceable Isolator complete all as directed by Engr-in-charge.
S&F including taking down old one of MCB TPN 40 to 63 Amps 415 Volts including taking down existing unserviceable MCB complete all as directed.
S&F MCB TP 40 to 63 Amps 415 Volts including taking down existing unserviceable MCB complete all as directed.
S&F MCB DB SPN 4 way double door type with 200 Amps rating Busbar and suitable arrangement for mounting MCB's including taking down old one complete all as directed .
S&F of MCB DB SPN 8 way double door type with 200 Amps rating Busbar and suitable arrangement for mounting MCB's including taking down old one complete all as directed.
S&F of MCB DB SPN 12 way double door type with 200 Amps rating Busbar and suitable arrangement for mounting MCB' including taking down old one complete all as directed by Engr-in-charge. Make for item No. 28 to 30:- STANDARD/ C&S/HAVELLS/ INDOASIAN
S&F LED 2'x2' type recess mounted lumniaire 24 Watt, Lumen Output -6500 lm , with Drive, connector block, etc. complete with all accessories internally pre-wired and including connecting up 3 core sheathed copper flexible cable 1.5 sqmm up to light fitting and connecting testing complete fixed on false ceiling complete.
Supply & Fixing LED fitting indoor tube light batten type, 18/20 W, Lumen output 2000 Lm, 230v Energy efficient, with Drive, connector block, etc. complete with all accessories internally pre-wired and including connecting up 3 core sheathed copper flexible cable 1.5 sqmm up to light fitting.
S&F LED Street light fitting with IP66 type protection, 90W, CCT (K) not less than 5700 Lm , 50 Hz and housing epoxy powder coated dia casted aluminuim housing with bright anodised reflector and enclosed with heat resistant and toughened glass front visor including constant current driver suitable for 140-270V AC , fixing on pole/Wall/bldg (including adjustment for up or down in pole or wall) side mounitng suitable for 40-60mm OD pipe and provn of 3 core PVC insulated PVC sheathed copper conductor multistranded wire upto fitting complete all as specified and directed. Make for item Nos.31 to 33: WIPRO/ PHILIPS/ JAGUAR/ BAJAJ/ HAVELLS / CROMPTION GREVES/ SYSKA
Supply & Fixing LED fitting.indoor type 35W (1'x 4'), 230v Energy efficient, Recess/ Surface mounted ,with Drive , connecter block, etc. complete with all accessories internally pre-wired and including connecting up with twin core hvisted flexible copper conductor cable with suitable size. Wipro Model NO CRCO13R038HP57 or equivalent in Philips/Crompton
Supply and lay XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sq. mm 3 Core including takingdown existing unserviceable HT cable complete all as directed.
Supply and lay XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 25 sq. mm 3.5 Core including takingdown existing unserviceable LT cable complete all as directed.
Supply and lay cable XLPE of size 16 Sqmm, 4 core multistranded aluminium conductor Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade including taking down XLPE cable complete all as directed.
Supply and lay cable XLPE of size 10 Sqmm, 2 core multistranded aluminium conductor Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade including taking down XLPE cable complete all as directed.
Excavation in trenches n.exc 1.5m wide and n. exc 1.5m in depth; for pole foundation, etc. or for cable laying, etc. n exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as directed
M&L Returning, filling in including spreading, levelling watering and well ramming in layers not exc 25 cm thick, using soil complete all as directed.
Removing excavated material to a distance n. exc 50 m and depositing where directed at a level n. exc 1.5M above the starting point complete all as directed.
M&L brick protection with unreinforced precast concrete flat cable covers of class HV of size 300x180x40mm for cable protection complete all as directed.
M & L for laying of bricks common burnt clay building bricks, sub class 'B' size 230x115x75mm for cable protection complete all as directed.
Supply and spread approved natural, clean dry river sand for cushioning of cable laid in trenches complete all as directed.
S&F of GI tubing of light grade with necessary fitings of size 50mm bore laying in trenches, floor/fixing on wall or roof complete all as directed.
Servicing of capacitor panel upto 400 KVAR and checking of capacitance of capacitor including control & power wiring complete cleaning of spares parts including testing of relay & contactor, tighting of nuts/bolts etc of any capacity after taking shutdown as per electrical safety norms complete all as directed.
S&F in repairs capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 5 KVAR capacity Make : L& T/Neptune
Supply and fix in repairs capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 10 KVAR capacity. Make : L& T/Neptune
Supply and fix in repairs capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 20 KVAR capacity. Make : L& T/Neptune
S&F FTL starter of capacity 40W, operating on 230V, AC supply including taking down old unserviceable starter complete all as directed. Make :- ANCHOR/ ROMA/LEADER/INDO ASIAN
S&F ceiling fan regulator electronic stepped type operating on 230V, AC supply including taking down old unserviceable regulator complete all as directed. Make: - ANCHOR/ ROMA/LEADER/INDO ASIAN
S&F switch socket 5 pin 15 Amps multipurpose type including taking down old unserviceable switch socket, complete all as directed Make : ANCHOR/ ROMA/LEADER
S&F switch socket 3 pin 5 Amps multipurpose type including taking down old unserviceable switch socket, complete all as directed Make :- ANCHOR/ ROMA/LEADER/INDO ASIAN
S&F MCCB fixed therma type 100 Amps, breaking capacity 16KA, 3-Pole, including all arrnagement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down old unserviceable MCCB complete all as directed . Make : Havells/C&S/Legrand
S&F MCCB fixed thermal type 125 Amps, breaking capacity 16KA, 3-Pole, including all arrnagement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down old unserviceable MCCB complete all as directed. Make : Havells/C&S/Legrand
S&F MCCB fixed thermal type , 200 Amps, 4 pole, breaking capacity 25 KA breaking capacity including taking down complete all as directed. Make : Havells/C&S/Legrand
S&F MCCB fixed thermal type 250 Amps, 4 pole, breaking capacity 25KA breaking capacity including taking down old unserviceable MCCB complete all as directed. Make : Standard/Havells/C&S/L&T
S&F MCCB fixed thermer type 400 Amps, 4 pole, breaking capacity 35KA including taking down old unserviceable MCCB complete all as directed. Make : Standard/Havells/C&S/L&T
S & F in repairs MCCB fixed thermal type, 100A DPX 125, 3 pole, breaking capacity 16 KA complete all as directed. Make : Havells/C&S/Legrand
S&F sheet metal enclosure suitable for fixing of MCCB's, 3P/4P of any type and capacity including taking down old unserviceable sheet metal enclosure complete all as directed.
S&F Capacitor of 2.5 mfd of ceiling fan including taking down old capacitor complete all as directed. Make: TIBCON/DADA /CAPCO/CG
S&F Capacitor of 3.15/4 mfd of ceiling fan/air circulator fans including taking down old capacitor complete all as directed. Make . TIBCON/DADA /CAPCO/CG
M&L for LT 1100 V straight through joints heat Shrinkable type suitable for 3.5 Core, 50 to 95 Sqmm cable including taking down existing old unserviceable joint complete all as directed
M&L for LT 1100 V straight through joints heat Shrinkable type suitable for 3.5 Core 120 to 185 Sqmm, cable ncluding taking down existing old unserviceable joint complete all as directed.
S&F for Galvanized iron strip 25 x 4 mm buried in ground/fixed on wall including taking down unserviceable GI strip complete all as directed.
Taking down FTL/HPSV/HPMV/CFL fitting of any capacity after dismantling from any height of pole/walls /any location and detecting the fault in the fitting by checking the accessories and wiring, refixing the same after repairs complete all as directed. Note :- Items like HPSV/MH ballast ,lamp, capacitor, etc shall be measured and paid separately under relevant items of this schedule.
Renewal of ballast copper wounded type of capacity 70 W suitable for HPSV light fitting complete all as directed.
All as per srl item No.67 here-in-before but 150 Watts complete all as directed.
All as per item No.67 here-in-before but 250 Watts complete all as directed.
All as per item No.67 here-in-before but 400 Watts complete all as directed.
Renewal of Lamp Tubular suitable for HPSV150W fitting
Renewal of Lamp tubular suitable for HPSV 250W fitting.
Renewal of Lamp Tubular suitable for HPSV 400W fitting.
Renewal of MH Lamp Suitable for 150 Watt
Renewal of MH Lamp Suitable for 250 Watt
Renewal of Ignitor for HPSV/HID fittings 70/150/250/400 W Make for srl Item No 67 to 75 : - CG/Wipro
Renewal of lamp holder suitable for HPSV/MV/halogen lamp up to 125 W screw /pin type complete all as directed
All as per item No.77 here-in-before but 150/250/400 complete all as directed.
Renwal of LED tube (T-8) 4 feet length,20/18W including taking down unserviceable tube complete all as directed. Make:CG/Wipro/Havells
Disconnecting and taking down old exisiting Bus bar insulator from VCB after taking shutdown complete breaker removing, Supply and fixing New Bus bar insulator in position with all connection complete testing and commissioning 11000V of capacity 1250 Amps on existing aluminium bus including cleaning with CTC and solution insulation of bus bar complete all as directed.
Inspection of defective cable to locate the fault using cable fault Locator machine complete all as directed.
Renewal of digital type volt meter suitable for Eleven KV breaker ranging (0-11KV) suitable for auxilary voltage 230 volts complete including taking down old unserviceable Voltmeter complete all as directed. Make- MECCO/AE/L&T
Renewal of digital type Ammeter suitable for Eleven KV breaker ranging (0-400) Amps suitable for auxilary voltage 230 volts complete including taking down old unserviceable Ammeter complete all as directed. Make- MECCO/AE/L&T
Supply & laying in repairs GI tubing of 40mm bore Medium grade for cable protection complete all as directed. Make of pipe: - OSWAL/PRAKASH/JINDAL
Renewal of service wire insulated PVC sheathed 2 core x 6 Sqmm aluminium conductor including taking down old defective wire complete all as directed
Renewal of service wire insulated PVC sheathed 2 core x 4 Sqmm aluminium conductor including taking down old defective wire complete all as directed
S&F PVC Junction box of size 250x200x100mm,light weight pole mounting including MCB SP 10Amps including necessary busbar MCB mounting arrangement and necessary connector for looping in and looping out cable connection and suitable glands including taking down old unserviceable junction box complete all as directed. Make :- SINTEX or techno commercially equal in Hensil and C&S
Supply and fix timer switch 32A, 3pole 230V, digital type suitable for timelite distribution board including taking down old unserviceable timer switch complete all as directed. Make: Cat Ref TL016ABQ of Indo Asian or equivalent in Havells/CG
Cutting and trimming the tree branches of any girth and of any size touching the overhead lines and clearing to a distane of 1.5 mtr length on either side of OH line with in an average span of 40 mtrs each and disposing the same and clearing the site complete all as directed.
M&L for cleaning the street light poles of any height including GI pipe for street light fitting and any description, cleaning thoroughly with cleaning agent including scrapping up of old corroded paint dirt/dust/ rust carefully and applying two coats of aluminium paint over one coat of red oxide metal primer paint before 01 Day of aluminium painting, and marking of zebra crossings up to a height of 1.5m above the coping with black and yellow strips of synthetic enamel paint including writing of pole numbers and two coats of black synthetic enamel paint on PCC coping complete all as directed. Note :- Strip size of yellow and black painting shall be directed. Make:- ASIAN (APCOLITE)/ SHALIMAR (SUPERLAC)/ BERGER (LUXOL)
Disconnection of all Primery/Secondary connection of the defective transformer of any KV rating, out door / indoor any make taking down / out from plinth / pole / platform with the help of crane and transporting the same carefully to workshop for repair and bringing back and install, with all connections as per directions, after repair to its existing position, upto 800 KVA capacity of transformer complete with testing and commissioning, complete all as directed.
Disconnection of all Primery/Secondary connection of the defective transformer of any KV rating, out door / indoor any make taking down / out from plinth / pole / platform with the help of crane and transporting the same carefully to workshop for repair and bringing back and install, with all connections as per directions, after repair to its existing position, upto 800 KVA capacity of transformer complete with testing and commissioning, complete all as directed.
Making Primery/Secondary coil with insulating copper wire of required gauge craft paper cotton tape HT/LT insulation as per specification of old transformer including making of coil as required of various capacity of transformer complete all as directed.
Reconditioning of over heated HT/ LT coil of transformer upto 800 KVA after removing all old insulation any type and re-insulation as required and remaking of LT coil complete all as directed.
Supply and fixing in repairs HT bushing including metal parts and washer complete for any make of plinth/pole mounted transformer of 63 to 315 KVA capacity complete all as directed.
Supply and fixing in repairs HT bushing including metal parts and washer complete for any make of plinth/pole mounted transformer of 400 to 800 KVA capacity complete all as directed
Supply and fixing in repairs LT rod / studs for 63 KVA to 315 KVA transformer made of brass with nut and washers, Insulator and fittings etc as per size and shape of existing complete all as directed.
All as per Srl item No. 97 here-in-before but for 400 KVA to 800 KVA complete all as directed.
Supply and fixing in repairs Gasket set upto 800 KVA for top of transformer or conservator tank after decanning the required level of oil all as directed.
Supply and fixing in repairs of air breather of any type up to 500 KVA transformer complete with filled silica gel complete all as directed.
Supply and fixing in repairs of air breather of any type above 500 to 1500 KVA transformer complete with filled silica gel complete all as directed.
Supply and filling of transformer oil having minimum break down voltage not less than 50KV, in transformer plinth/pole mounted including testing complete all as directed. Make:- SERVO / POWER OIL
Dehydration including filtration cleaning of transformer oil in transformer indoor / outdoor type at different locations of DLRL area by centifusion / machine having minimum capacity 1000 to 30000 ltrs / hrs including testing oil before and after dehydration complete all as directed.
Supply and fixing in repairs Silica gel complete all as directed.
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board CPRI approved cubical type made of 2 mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 500 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations, testing and commissioning complete and consisting the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (a) MCCB fixed thermal ltype, 4 Pole, 315 Amps, 35KA breaking capacity -01 No. (as Incoming) (b) MCCB fixed thermal type, 3 Pole, 250 Amps, 25KA breaking capacity -01 No. (as Outgoing) (c) MCCB fixed thermal type, 3 Pole ,,200 Amps, 25KA braking capacity -02 Nos (connected-01 & Spare-01) (as Outgoing) (d) MCCB fixed thermal type, 3 Pole, 25-63 Amps, 16KA breaking capacity -03 Nos (as Outgoing) Make-L&T/Schneider/ABB/Havells
Opening of the 11 KV / 0.433 KV transformer up to 500 KVA by removing the inspection cover / top cover, decanning of the transformer oil up to the required level for replacement of leaked cork seal with insulator or LT/HT bush (which is unsv) complete from the shell and making again connections of LT/HT bush to avoid leakage of oil refilling back to existing oil into the transformer testing & commissioning complete all as directed Note : HT/LT bush will measured and paid separately under relevant item and cork seal with insulator is deemed to be included in quoted rate.
Opening of the 11 KV / 0.433 KV transformer 500 KVA to 1000 KVA by removing the inspection cover / top cover, decanning of the transformer oil up to the required level for replacement of leaked cork seal with insulator or LT/HT bush (which is unsv) complete from the shell and making again connections of LT/HT bush to avoid leakage of oil refilling back to existing oil into the transformer testing & commissioning complete all as directed Note : HT/LT bush will measured and paid separately under relevant item and cork seal with insulator is deemed to be included in quoted rate.
M&L for opening the top of Transformer upto 1000 KVA for renewal of jumpering (with brazing or welding) with new copper wire of existing size after removal of burnt out jumpering including decanning of oil upto required level and testing the tranformer complete all as directed.
M&L for Cable jointing kit for HT, Eleven KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm including taking down old unserviceable joint complete all as directed.
M&L for Cable jointing kit for HT, Eleven KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 400 Sqmm including taking down old unserviceable joint complete all as directed.
M&L for cable end termination kit, heat shrinkable, outdoor type, suitable for 3 core x 120 to 185 Sqmm HT, 11 KV cable with necessary lugs including taking down old unserviceable jointing kit complete all as directed.
Taking down the unserviceable disc insulator and S&F new disc type porcelain insulator vitreous brown 145mm height and 255mm dia ball and socket type single disc assembly with GI clamp nuts and bolts etc suitable for 11000 V grade working pressure complete all as directed.
Renewal of barrel fuse single pole 20 amps (suitable for 200 KVAR capacitor bank each of 100 KVAR capacity) complete all as directed.
S&F in repairs tinned Copper fuse wire of 30 Amp to 50 Amps capacity complete all as directed.
All as per srl item No.114 here-in-before but of Capacity 100 Amp
M&L for HT 11 KV, Air Break Switch,Gang operated,Triple pole, mechanically operated, mounted on insulator and steel frame, with oprating mechanism worked from ground level suitable for 11KV supply and current rating upto 400Amps including taking down unserviceable AB switch complete all as directed.
Servicing of 11KV 3-Phase Gang Operated Device including replacing the defective items and applying mineral Jelly,oil, grease after proper removal of carbon deposits, refixing of Switch A/B Gang operated triple pole mechanically operated mounted on isolator and steel frame with operating mechanisam works from Ground level, complete all as directed.
S&F 11 KV Grade, Lightning arresters expulsion type complete (Set of Three) with all fittings, transmission class,11000Volts discharge capacity 65KA including taking down unserviceable light fitting arrestors complete all as directed.
M&L for cement concrete 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundations, filling & mass concrete including domolition of existing old concrete work complete all as directed.
M&L Cement concrete 1:3:6 type C2 (using 40mm graded aggregate) as in foundation, filling & mass concrete for electric pole & mass concrete including domolition of existing old concrete work complete all as directed.
Supply and Fixing in repairs battery cell UPST 100 for 110V or 30 V Battery Bank complete all as directed. Make :- Exide - UPST 100.
M&L for cleaning/Painting the HT poles of OH lines and six poles/four poles/two poles structure complete with cross arms any height and any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/rust carefully and applying two coats of aluminum paint including marking of pole numbers for the following : -
Single HT Poles
Two poles with cross Arms
Four Poles with cross Arms
Six Poles with cross Arms
S&F in repairs panel circuit board (PCB) including display unit suitable for Air cooled chiller AC plant of capacity upto 33 TR including making necessary connection, testing, complete all as directed. Make- Blue Star /Voltas
Taking down UNSV Ceiling fans/Exhaust fans/Pedestal Fan, dismantling, overhauling,and replace the unserviceble spares like Ball bearing/ bushes, Capacitors, down rods including reassembling/refixing back in the same location, including with cord flexible copper conductor connections after completion of repairs, complete all as directed . Note: Spare parts will be measured and paid separately under relevant items.
M&L for rewinding of fan motor of any make/sweep of ceiling fan, exhaust fan any dia mm, including removal of existing burn't winding carefully from slots,cleaning the slots with cleaning agents,and rewinding with super enameled copper wire of same guage/type,varnishing complete all as directed .
S&F of Capacitor of 2.5 mfd including taking down old one complete all as directed.
Supply only ball bearings suitable for any type of fan/exhaust fan and testing complete all as directed. Make-NBF/NBC/TATA
Taking down unserviceable down rod of ceiling fan and replace with new down rod (Pin or Thread type) to any height including painting for fixing ceiling fans,including connected spares for mounting of fan, complete all as directed .
M&L steel tubular swaged poles type 410 SP-31 (9.0 meter long) complete with CI base plate including errection of pole with excavation and earth work including PCC (1:4:8) type D2 for foundation base and PCC (1:3:6) type C1 for foundation and coping with PCC (1;2:4 ) and painting two coats Red oxide paint including removing of old unserviceable steel tubular pole complete all as directed by Engr-In-Charge. Note:- Crane charges for erection shall be deemed to be inclusive in quoted rate. Make : M/S BOMBAY TUBES/ M/S JINDAL STEEL PRODUCTS/ M/S INDIA TUBES CO / M/S BHARAT POLES/ NATIONAL TUBING
Removing defective fan motor from A/C and rewinding of blower motor with same gauge and turns of copper enameled wire and replacement of bearing, & refixing, testing and commissioning of 1.5 Ton window/Split type AC of any make complete all as directed.
S & F in repairs Running capacitor of 50+6 MFD for Window/Split type AC's all as directed.
S & F in repairs Running capacitor of 36 MFD for Window/Split type AC's all as directed.
Rewinding of blower motor with same guage and turns and weight of copper enameled wire and replacement of bearing, testing and commissioning of 1.5/2.0 Ton split type AC of any make, any model complete all as directed.
Taking down carefully old burnt/unserviceable compressor unit of 1.5 ton capacity window type AC of any make and model and replacing the same with Brand new Com-pressor (reciprocating /rotary) including necessary accessories and mounting materials, welding, brazing, leak testing, vaccumissing and charging the refrigerant gas to the required pressure and weight, reinstalling the AC unit on the same place including testing and commissioning complete all as directed. Make : VOLTAS/VIDEOCON/ CARRIER/ BLUESTAR/ /LG/HITACHI
All as per Item No-134 above but 1.5 Ton Split type AC
Servicing and overhauling the 1.5/2.0/3.0 Ton capacity (Window/Split) AC with water, chemical air clearner, filter and drying, checking the bolt and nut connections, filling, refixing and testing complete all as directed.
S & F in repairs evaporating coil made out of 25 SWG copper tubing having 30/34G aluminium fins per length for window /split type AC's of 1.5 Ton capacity complete all as directed
Taking out the unserviceable condensor coil and S & F new condensor coil made out of 25 SWG copper tubing having 30/34G aluminium fins per CM length for window /split type AC's of 1.5 Ton capacity .
S & F in repairs Fan Motor Single phase, 230V for 40/80 Ltrs capacity Water Coolers of any make complete all as directed. Make- AUE/C&G
S & F in repairs Starting Capacitor 60/80 Mfd, for 40/80 Ltrs capacity Water Coolers of any make complete all as directed.
S & F in repairs Running Capacitor , for 40/80 Ltrs capacity Water Coolers of any make complete all as directed.
Removing of defective fan motor from water cooler rewinding of fan motor with same gauge and turns and weight of copper enameled wire and replacement of bearing and refixing, testing and commissioning of water coolers of any make complete all as directed.
S & F in repairs of Water circulation pump motor as per existing capacity complete for desert coolers of any make complete for capacity 3000/4000 CUM. Make-TULLU/CG/BAJAJ/Kaithan
S & F in repairs of Fan motor of desert cooler single phase, 215 Volts, AC, 50 Hz complete for desert coolers of any make complete for capacity 3000/4000 CUM. Make- C&G/BAJAJ/ AUE/ kaithan
S & F in repairsof Fan blade of desert cooler Metallic/PVC as per existing model complete for desert coolers of any make complete for capacity 3000/4000 CUM.
S & F in repairs of KHAS-KHAS (One set of three) as approved by Engr-in-charge, complete for desert coolers of any make complete for capacity 3000/4000 CUM.
Supply and fix in repairs copper tube of size 3/8, 5/8 inch dia including necessary soldering , flooring and connecting and testing in between indoor to out door units of split type AC 1.5 Ton complete all as specified and directed.
Description all as per Item No-147 above but size of copper tubing 1/2, 1/4 inch dia complete all as directed.
S & F in repairs insulation felt for split type AC 1.5 / 2.0 Ton copper tube inlet/outlet to out door unit complete all as directed.
Supply & charge in repairs refrigerant gas R-22 upto required level complete all as specified and directed. Make- MAFRON/FREON
S & F in repairs indoor blower for split type AC as per existing model, sample complete all as directed.
M&L for dismantling concrete and removing of existing 09 metre long LT Steel tubular swaged pole complete with cast iron base plate, final taper plug, bolts, nuts and screws and erecting in new location including one coat of aluminium paint for exposed surfaces and one coat of black bituminious internally and of external embodded portion in ground and Zebra Crossing Strips from Copping (Copping Excluded) to 1.5 mtr height with Yellow and Black Strip and Copping should be painted with Black Paint, complete with excavation,earth work,PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation and coping of poles PCC 1:3:6 type C1 (using 20mm graded aggregate), including transportation from one place to another place inside Lab area, complete all as directed by Engineer-in-Charge. Note:- Rate quoted is deemed to be included excavation, earth work,foundation and coping work and painting work complete. Strip size of painting shall be directed by Engr -in-Charge at the time of execution.
CHITRA ENGINEERING CORPORATION
S.S.ENGINEERING CORPORATION
UNITY ENGINEERING TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .