Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹36.2 L+₹59,248 (1.66%)Rejected-Finance FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L2 | Rejected-Finance RATE HIGH | |
| 3 | L3₹36.5 L+₹83,418 (2.34%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L3 | Rejected-Finance RATE HIGH | |
| 4 | L4₹37.1 L+₹1.5 L (4.10%)Rejected-Finance | L4 | Rejected-Finance RATE HIGH | |
| 5 | L5₹37.3 L+₹1.6 L (4.55%)Rejected-Finance | L5 | Rejected-Finance RATE HIGH |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
14 Nov 2023, 6:00 pmClosed
GE South Pune
NO 1 GEN BHAGAT MARG PUNE 411040
8462 PREVENTIVE MAINTENANCE OF PROTECTIVE SYSTEM AND REPAIR REPLACEMENT OF LT DISTRIBUTION AND PROTECTIVE SYSTEM POLE PANEL UG CABLE EXTERNAL ELECTRICAL SYSTEM IN EME WORKSHOP SHO MINTSD OFFICERS QTRS JCO QTRS UNDER AGE EM I OF GE SOUTH PUNE
2023_MES_623712_1
8462 GE SOUTH PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE South Pune
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹90,000
Yes
11 Jan 2024
17 Oct 2023
16 Nov 2023
17 Oct 2023
14 Nov 2023
31 Oct 2023
Amount
Dismantling unserviceable steel poles /struts any size and removing from site complete all as specified and directed.
Dismantling unserviceable stay assembly and removing from site, complete all as specified and directed.
Dismantling cross arms of MS channel or angle sections etc and setting aside for reuse within 50 m, complete all as specified and directed.
Dismantling unserviceable galvanized earth steel wire 3.15 or 4 mm dia and existing hexagonal cradle guard HT/LT poles and removing binding wire and removal of the same from site complete all as specified and directed by Engineer-in-Charge.
Dismantling old ACSR conductor any size from over head lines, poles by removing binding wire, service wire, cables and removal from site, complete all as specified and directed.
Dismantling insulator any type/ any size from LT poles, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft/loose soil complete all specified and as directed.
All as per Serial item No 7.00 above but depth exceeding 1.5 mtr and not exceeding 3.00 mtr , complete all as specified and directed.
Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point, complete all as specified and directed.
Returning filling in incl spreading leveling watering and well ramming in layers n. exc 25cm thick, complete all as specified and directed.
Material & labour cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation complete all as specified and directed by Engineer- in-charge.
Material & labour PCC 1: 3 : 6 type C-1 (using 20 mm graded mechanically crushed stone aggregate) as in stays and coping of poles including necessary form work complete all as specified and directed.
Supply, fixing and errecting in true vertical position of steel tubular swaged pole swan neck type single arm 11 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55, conforming to IS-1678 including painting with anti corrosive black bituminous paint internally complete and externally up to planting depth and exposed portion with Aluminium paint two coats over a coat of red oxide primer including taking down of old unserviceable / damaged pole complete all as specified and directed by Engr-in-charge. (Note : Excavation and earth work, PCC for foundation and coping shall be measured and paid seperately under respective item of BOQ)
Supply, fixing and errecting in true vertical position of steel tubular swaged pole swan neck type single arm 9 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, conforming to IS-1678 including painting with anti corrosive black bituminous paint internally complete and externally up to planting depth and exposed portion with Aluminium paint two coats over a coat of red oxide primer including taking down of old unserviceable / damaged pole complete all as specified and directed by Engr-in-charge. (Note : Excavation and earth work, PCC for foundation and coping shall be measured and paid seperately under respective item of BOQ)
Supplying and fixing in replacement galvanized stay stranded wire of size 7/4 mm and fixing to stay assembly complete all as shown in electrical plate No 1 of SSR-2009 (Part-I) complete all as specified and directed.
M & L for GI Stay assembly set comprising of 14 mm dia 400 mm iron stay bow, 2150 mm long stay rod 20 mm dia, stay plate 300 x 300 x 6 mm thick complete with all aceessories as shown in electric plate no 1 of MES schedule Part I, complete all as specified and directed. Note :- Earth work, PCC, loop type insulator, galvanized stay stranded wire will be measured separately.
Supply & fixing loop type insulator, vitreous porcelain, white brown or green with over all dimensions 90 mm x 140 mm, clearance of hole 25.5 mm suitable for 11000 volts complete all as specified and directed.
Material & labour for Cross Arms bracings supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps stay clamps, D clamps nuts, bolts , washers welding bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Supply and fixing of cradles, hexagonal / Rectangular, fabricated with galvanized steel wire 4 mm dia including stretching, sagging and jointing in position as a continuous earth wire on pole and for guarding complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Aluminium conductor steel reinforced (ACSR) of any size for LT OH lines on poles including stringing ,binding with aluminium wire 14 SWG or aluminium tape including jumpers complete connecting of disconnected cable, service cable and street light connection complete all as specified and directed by Engr In charge.
Supply and fixing insulatiors pin type LT 1100 Volts grade porcelain vitreous white or brown including one galvanized mild steel spindle, two galvanized iron washers, iron nut, 100 mm height, 65 mm dia complete all as specified and directed by Engineer–in-charge.
Supply and fixing shackle type insulator LT 1100 volt grade porcelain vitreous white or brown including insulator bolts, nuts 12 mm dia, 75 mm height and 90 mm dia of insulator complete all as specified and directed by Engineer-in-Charge.
Prunning / trimming the branches of trees if any along overhead line, 3 mtr on all side below/ above/ sides of overhead line and removing the same upto 150 mtr away, each span not exceeding 45 mtr complete all as specified and directed by Engineer-in-Charge (Note- The above work shall be caried out for the entire contract period by cutting / trimming of trees any number of times as required at site).
Stringing / stretching , including jointing in situ of each span not more than 45 Mtrs between two electric poles having 4 nos. of ACSR of any size with and including GI earth continuity wire, with / without guarding wires on electric poles of any size at different locations all as ordered manually or by telephonically means to the extent of permissible sag limit or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete as ordered, complete all as directed by Engr-in-charge. Note :- One span including 4 wire of LT over head line and two nos of earth wire.)
All as per serial item no 24 above but for two wires, complete all as directed by Engr-in-charge. Note :- One span includes 2 wire of LT over head line and two nos of earth wire.
M & L for replacement for PVC separator in position to keep ACSR conductor as equal spacing suitable for 2 Wire system, complete all as directed by Engr-in-charge.
M & L for replacement for PVC separator in position to keep ACSR conductor as equal spacing suitable for 4 Wire system, complete all as directed by Engr-in-charge.
Supply and fix in repairs GI Strip 32mmx6mm in any position , bending in shape and fixing in position with suitable size GI nuts, bolts & washers or by welding, complete all as specified and directed.
Supply and fix in repairs of aluminium strip 25 mm x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed by Engr-In-Charge.
S & F 1100 volts grade heavy duty flat cable of size 4 sqmm 2 core, PVC insulated aluminum solid conductor , served with inner sheathing of pvc tape and overall PVC sheathed in service connections suspended by insulating hangers not more then 1 mtr apart including replacing 4 mm suspension wire, complete all as specified and directed.
All as per item No.30 here in above but size 6 Sqmm 2 core, complete all as specified and directed.
All as per item No.30 here in above but size 10 Sqmm 2 core, complete all as specified and directed.
All as per item No.30 here in above but size 16 Sqmm 2 core, complete all as specified and directed.
Material & Labour painting of steel tubular LT poles including cross arms, clamps, back plates etc in situ on with one under coat and one finishing coat with aluminum paint after cleaning /preparation of surfaces including making white and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint and marking of pole No , Subsation No also, complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground level connected to with and including earth lead of 4mm dia GI wire up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth wire protected by galvanised iron 15 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing wire shall be encased in and including 15mm nominal bore GI 'light grade' tubing with all fittings from earth plate up to panel shall be provided & charcoal / salt funnel & other fittings etc. complete all as specified and as directed. Note :- (i) GI earth wire and GI pipe 15mm bore medium grade for encasing GI GI earth wire upto 7.50m length per earthing shall be deemed to be included in the unit quoted rate.
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground level connected to with and including earth lead of 32x6 mm size GI strip up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth strip protected by galvanised iron 50 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing strip shall be encased in and including 50mm nominal bore GI 'light grade' tubing with all fittings from earth plate up to panel shall be provided & charcoal / salt funnel & other fittings etc. complete all as specified and as directed. Note :- (i) GI strip and GI pipe 50mm bore medium grade for encasing GI strip upto 7.50m length per earthing shall be deemed to be included in the unit quoted rate.
Taking up underground cable of size 16 sqmm 2/4 core to 35sqmm 3.5core from trenches including bricks etc as required complete all specified and as directed.
Taking up underground cable of size 50 sqmm 3.5 core to 95 sqmm 3.5core from trenches including bricks etc. as required complete all specified and as directed.
Taking up underground cable of size 120 sqmm 3.5 core to 150 sqmm 3.5core from trenches including bricks etc. as required complete all specified and as directed.
Supply and laying XLPE insulated armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core, complete all as specified and directed.
All as per Sch 'A' item No. 40 here in above but size 16 sqmm 2 Core, complete all as specified and directed.
All as per Sch 'A' item No.40 here in above but size 16 sqmm 4 Core, complete all as specified and directed.
All as per Sch 'A' item No. 40 here in above but size 25 sqmm 4 Core, complete all as specified and directed.
All as per Sch 'A' item No. 40 here in above but size 35 sqmm 3.5 Core, complete all as specified and directed.
All as per Sch 'A' item No. 40 here in above but size 50 sqmm 3.5 Core, complete all as specified and directed.
All as per Sch 'A' item No. 40 here in above but size 70 sqmm 3.5 Core, complete all as specified and directed.
All as per Sch 'A' item No. 40 here in above but size 95 sqmm 3.5 Core, complete all as specified and directed.
All as per Sch 'A' item No. 40 here in above but size 120 sqmm 3.5 Core, complete all as specified and directed.
All as per Sch 'A' item No. 40 here in above but size 150 sqmm 3.5 Core, complete all as specified and directed.
All as per Sch 'A' item No. 40 here in above but size 185 sqmm 3.5 Core, complete all as specified and directed.
Material and labour for sand cushioning with dry river sand / crushed stone dust in trenches for cushioning of underground cable line including spreading, leveling, well ramming, complete all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks (designated 75) locally available best quality laid dry in trenches for protection of underground cable, complete all as specified and directed.
Supply and fixing in replacement of GI pipe , light grade, 40 mm bore , confirming to IS-1239, for cable protection on poles / walls / Road crossing / floor crossing, complete all as specified and directed.
All as per item No.53 here in above but 50mm bore, complete all as specified and directed.
All as per item No. 53 here in above but size 80mm bore, complete all as specified and directed.
All as per item No. 53 here in above but size 100mm bore, complete all as specified and directed.
Material and labour for Retro Reflective installation sign boards size made out of 3mm thick acrylic flexible sheet of 2.5m x 1m x 20cm fabricated out of 14 SWG MS sheet frame duly welded /riveted with square pipe of size 25mm x 25mm at height 2.25 meter on 50x50x6 mm size angle iron frame – 02 Nos. grouting with PCC 1:2:4 type B-1 Block of size 45x45x60cm. The board shall be painted in stove enameled paint and the front of the frame shall be overall sheathed with blue colour base and including providing LED 1x20 watt light fittings- 04 Nos. with internal wiring complete letters of white colour all as per specimen provided and complete all as directed by Engr-in-Charge
S&F Elect Shock Treatment Chart in Hindi , English and regional language laminated type of size 60 x 32 Cm (Approx) to be displayed in installations, completed all as directed by Engr-in charge.
M&L for MCCB TP, 50-63 Amps,16 KA, 415 volts Ics= 100% Icu, Adjustable over load setting 0.8-1.0 x In and Adjustable short circuit setting 6-10x In with spreader links and separators Confirming to IS/IEC 60947-2, complete all as specified and directed.
All as per sl item no-59 above but, rating MCCB TP, 63-80 Amps,16 KA, 415 volts, complete all as specified and directed.
All as per sl item no-59 above but, rating MCCB TP, 80-100Amps, 16 KA, 415 volts, complete all as specified and directed.
All as per sl item no-59 above but, rating MCCB TP, 100-125 Amps, 16 KA, 415 volts, complete all as specified and directed.
All as per sl item no-59 above but, rating MCCB TP,125-160Amps ,16 KA, 415 volts, complete all as specified and directed.
All as per sl item no-59 above but, rating MCCB FP, 160-200 Amps, 25 KA, 415 volts, complete all as specified and directed.
All as per sl item no-59 above but, rating MCCBFP, 200-250 Amps, 35 KA, 415 volts, complete all as specified and directed.
All as per sl item no-59 above but, rating MCCB FP, 320-400 Amps , 35 KA, 415 volts, complete all as specified and directed.
S&F in repairs straight through (Heat shrinkable jointing kit) suitable for LT underground cable, 1.1 KV including cable connection on pole, complete all as specified and directed of following sizes:- (a) 16 to 35 Sqmm 3 1/2 Core
(b) 50 to 95 Sqmm 3 1/2 Core
(c) 120 to 185 Sqmm 3 1/2 Core
M&L for laying of Reinforced concrete pipes, class NP2 with one collar per lengh of pipe of dia 100 mm, 2 nos half round ( for bottom and top ) shall be leveling, complete all as specified and directed Engr-in-charge.
Taking down LT panel / feeder pillar boxes from foundation complete all as specified and directed by engr-in-charge.
Supply, installing, testing and commissioning factory made & tested including CPRI type test certified) LT feeder pillar box (KIOSK) outdoor type mounted on angle iron frame of size 40mmx40mmx6mm, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated copper bus bars of rating 400 Amps rating installed on porcelain insulator. The panel shall be of dust and vermin proof with gable roof, IP-65 class protection with and including made of 3.15 mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front & back side opening type with apron for cable entry with double door shutter and locking arrangement (including provision of 65mm Godrej lock with two keys) complete with internal wiring with PVC insulated solid copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size of wire (but not less than 2.5 Sqmm) with and including the following provisions:-
(c) M&L for construction of platform for the panel with PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate, 15 cm thick as in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding in PCC 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be constructed in such manner that it will be 60 cm above from the nearest road level. Drawing and size of platform will be provided by Engr-in-charge.
Supply, installing, testing and commissioning factory made & tested including CPRI type test certified) LT feeder pillar box (KIOSK) outdoor type mounted on angle iron frame of size 40mmx40mmx6mm, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated copper bus bars of rating 400 Amps rating installed on porcelain insulator. The panel shall be of dust and vermin proof with gable roof, IP-65 class protection with and including made of 3.15 mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front & back side opening type with apron for cable entry with double door shutter and locking arrangement (including provision of 65mm Godrej lock with two keys) complete with internal wiring with PVC insulated solid copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size of wire (but not less than 2.5 Sqmm) with and including the following provisions:-
(c) M&L for construction of platform for the panel with PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate, 15 cm thick as in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding in PCC 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be constructed in such manner that it will be 60 cm above from the nearest road level. Drawing and size of platform will be provided by Engr-in-charge.
Supply, installing, testing and commissioning factory made & tested including CPRI type test certified) LT feeder pillar box (KIOSK) outdoor type mounted on angle iron frame of size 40mmx40mmx6mm, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated copper bus bars of rating 400 Amps rating installed on porcelain insulator. The panel shall be of dust and vermin proof with gable roof, IP-65 class protection with and including made of 3.15 mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front & back side opening type with apron for cable entry with double door shutter and locking arrangement (including provision of 65mm Godrej lock with two keys) complete with internal wiring with PVC insulated solid copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size of wire (but not less than 2.5 Sqmm) with and including the following provisions:-
(c) M&L for construction of platform for the panel with PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate, 15 cm thick as in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding in PCC 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be constructed in such manner that it will be 60 cm above from the nearest road level. Drawing and size of platform will be provided by Engr-in-charge.
Supply, installing, testing and commissioning factory made & tested including CPRI type test certified) LT feeder pillar box (KIOSK) outdoor type mounted on angle iron frame of size 40mmx40mmx6mm, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated copper bus bars of rating 400 Amps rating installed on porcelain insulator. The panel shall be of dust and vermin proof with gable roof, IP-65 class protection with and including made of 3.15 mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front & back side opening type with apron for cable entry with double door shutter and locking arrangement (including provision of 65mm Godrej lock with two keys) complete with internal wiring with PVC insulated solid copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size of wire (but not less than 2.5 Sqmm) with and including the following provisions:-
(c) M&L for construction of platform for the panel with PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate, 15 cm thick as in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding in PCC 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be constructed in such manner that it will be 60 cm above from the nearest road level. Drawing and size of platform will be provided by Engr-in-charge.
S&F in repairs DIN type HRC fuse link type HN of capacity 125 Amps, complete all as specified and directed.
S&F in repairs DIN type HRC fuse link type HN of capacity 160 Amps, complete all as specified and directed.
S&F in repairs DIN type HRC fuse link type HN of capacity 200 Amps, complete all as specified and directed.
S&F in repairs LED street light fitting 35W, 230V, AC, outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection, complete all as specified and directed.
S&F in repairs LED street light fitting 60 W, 230V, AC, outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection, complete all as specified and directed.
S&F in repairs LED street light fitting 70 W, 230V, AC, outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection, complete all as specified and directed.
S&F in replacement MPP Cylindrical Capacitor Fixed type 10KVAr make - Schneider / VAC /L&T / Epcos, complete all as specified and directed.
Supply and fix in replacement capacitor bank 5 KVAR capacity MPP, 440V 50Hz AC make L&T / Crompton Greaves / Meher / epcos, complete all as specified and directed.
S&F in replacement cooling fans sitable for capacitor panel heat dissipation of reputed standard make, complete all as specified and directed.
S&F in replacement Indicating Lamps (ON /OFF), Make - L&T / Schneider / Siemens, complete all as specified and directed.
M&L for replacement of outdoor type junction box made out of CRCA sheet 3mm powder coated comprising of epoxy coated aluminium bus bar 400 Amps - 04 Nos. drilled holes and GI nut bolts of suitable size for four nos. three phase four wire cables (3 Phase and 1 Neutral), Aluminium bus bars 1.20 m long mounted on insulator epoxy insulators with double covers and providing one MCCB 250 Amps, Four Pole, 415V, 25 KA housed in separate chamber, iron frame made out of angle iron of size 40mmx40mmx5mm at 60 cm clear height from ground level complete with grouting of angle legs of sufficient length in PCC 1:2:4 type B-1, complete all as specified and directed.
M&L for testing and find out the fault in LT underground cable with the help of by providing cable fault locating machine at site including removal of moisture content from cable complete all as directed by Engr-incharge. (Note:- (a). The fault locating machine will be arranged by the contractor at his own cost i.e the cost of bringing of fault locating machine at site shall be deemed to be included in unit quoted rates. (b). Necessary excavation and earthwork etc. shall be measured and paid separately under respective items of BOQ
M&L for 4mm dia galvanised or steel wire as in earth continuity wire or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing, complete all as specified and directed.
As per item no 96 above but 32mmx6mm galvanised iron strip, complete all as specified and directed.
All as per item no 96 above but 25mmx3mm aluminium strip, complete all as specified and directed.
Surface excavation n. exc. 30 cm depth and averaging 15 cm depth and getting out in soft / loose soil including clearing away all grass and vegetation saplings, shrubs, bushes, undergrowth roots and removing rubbish up to a distance n. exc. 50 mtrs outside the periphery of the transformer/ 2 pole /4 pole structure/ feeder pillar area, complete all as specified and directed. Note:-The contractor will ensure that no vegetation should grow during the contract period on the area so excavated.
Supply, installing, testing and commissioning factory made & tested including CPRI type test certified) LT feeder pillar box (KIOSK) out door type mounted on angle iron frame of size 40mmx40mmx6mm, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated copper bus bars of rating 300 Amps rating installed on porcelain insulator. The panel shall be of dust and vermin proof with gable roof, IP-65 class protection with and including made of 3.15 mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front & back side opening type with apron for cable entry with double door shutter and locking arrangement (including provision of 65mm Godrej lock with two keys) complete with internal wiring with PVC insulated solid copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size of wire (but not less than 2.5 Sqmm) with and including the following provisions:-
(c) M&L for construction of platform for the panel with PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate, 15 cm thick as in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding in PCC 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be constructed in such manner that it will be 60 cm above from the nearest road level. Drawing and size of platform will be provided by Engr-in-charge.
Supply, installing, testing and commissioning factory made & tested including CPRI type test certified) LT feeder pillar box (KIOSK) out door type mounted on angle iron frame of size 40mmx40mmx6mm, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated copper bus bars of rating 200 Amps rating installed on porcelain insulator. The panel shall be of dust and vermin proof with gable roof, IP-65 class protection with and including made of 3.15 mm CRCA MS sheet and 40x40x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front & back side opening type with apron for cable entry with double door shutter and locking arrangement (including provision of 65mm Godrej lock with two keys) complete with internal wiring with PVC insulated solid copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size of wire (but not less than 2.5 Sqmm) with and including the following provisions:-
(c) M&L for construction of platform for the panel with PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate, 15 cm thick as in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding in PCC 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be constructed in such manner that it will be 60 cm above from the nearest road level. Drawing and size of platform will be provided by Engr-in-charge.
Chaulya Enterprises
Rama Electricals
Mepcon Projects Pvt LTd
CHAITANYA WINDWELL
Sparkh Electricals & Works
Mahindra Electric Stores
Leo Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .