Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹2.5 L+₹2,067.37 (0.85%)Rejected-Finance | L2 | Rejected-Finance HIGHEST BIDDER | |
| 3 | L3₹2.5 L+₹2,675.42 (1.10%)Rejected-Finance BAPPA CONSTRUCTION BINPUR JHARGRAM | BINPUR | JHARGRAM | WEST BENGAL | 721514 | L3 | Rejected-Finance HIGHEST BIDDER |
Tender Value
₹2.4 L
EMD Value
₹4,864
Closing Date
19 Jan 2026, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
OFFICE OF THE ASSISTANT ENGINEER MIDNAPORE ELECTRI
GOVERNMENT OF WEST BENGAL OFFICE OF THE ASSISTANT ENGINEER MIDNAPORE ELECTRICAL SUB-DIVISION, P.W.Dte. P.O.Midnapore, Dist. Paschim Medinipur.
EI work of creation of special court to deal exclusively with offences under NDPS Act on existing building at 4th Court at District Judges Court, Paschim Medinipur
2025_WBPWD_980083_1
WBPWD/AE/MESD/NIT-07/e-T /2025-2026
Open Tender
ELECTRICAL WORKS ORG
Percentage
7 days
PASCHIM MIDNAPORE
Please refer Tender documents.
3 documents required · 3 mandatory
₹4,864
13 Feb 2026
26 Dec 2025
21 Jan 2026
26 Dec 2025
19 Jan 2026
26 Dec 2025
Dismantelling the existing wiring of 4th court building and material submitted to the authority/Section office as per direction of EIC.
Supplying and fixing 250 V, 6-10A per way, (2+8) SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 1 nos 40A DP MCB type Isolator, 8 nos. 6-16A SPMCB) (Make- Siemens/ Schneider/ Legrand)
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works....19 mm dia 3 mm thick polythene pipe without earth continuity wire.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make- Policab/ Havells/ Gloster/ KEI) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.
a) 2 x 2.5 sqmm. (P ) & 1 x 1.5sqmm.as ECC for computer board & PP
b) 2 x 4 sqmm. (P ) & 1x 2.5 sqmm.as ECC for AC
c) 2x 6 sqmm.+ 1x 4.0 sqmm.as ECC for SPNDB
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
a) 2.5sqmm
b) 4sqmm
c) 6sqmm
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed]Average Run 8 Mtr
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish.
a) On board
b) Average run 4.5 Mtr
Fixing of single/twin LED fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by Each Rs. 199.00 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. Make- Philips/ Bajaj/ CG)
Supply & Delivery of 4 feet double LED fitting including incl. all accessories. (Make :- Philips, Cat. No.- TMC 502 2xT-LED 22W / Wipro)
Supply & Delivery of 4 feet single LED fitting including incl. all accessories. (Make :- Philips, Cat. No.- TMC 502 1xT-LED 22W / Wipro)
Supply & Delivery of 230V, 18 watt Polycarbonate body, Aluminium heat sink, 2100 lm LED Mas tube light (Make :- Philips, Cat. No. - Mas LEDTube 1200 mm 18W 865 T8I - 2100lm / Wipro)
Extra for suspention exceeding 25 cm with S & fixing additional 2 no 20 mm dia EI conduit (14) SWG supports & necy. PVC insulated wire and painting etc.by 3 * 1.5 sq mm stranded cu wire.
S & D 1200mm sweep AC ceiling fan with out regulator, complete with P2 burst proof Capacitor, Down rod, blades, canopy, rigidly connected Safty Tie wire etc. Incl. other accessories as necessary. (Make - Cromton High Speed(HS) / Usha Striker plus / Orient Summer breeze)
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
S & Fixing 19 mm dia GI pipe for fan down rod drill hole both side witc painting incl. with S & f 3 * 1.5 sq mm PVC insulated stranded cu wire as per GS.
Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991)
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
S &F 9 Watt LED Lamp. Make-Philips/ Crompton/ Bajaj/ Wipro
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board.
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supplying & fixing 250 V 3 Pin 20 A flush type plug socket with 20 A Piano key type (Anchor make) switch on sheet metal box with bakelite top cover and earthing attachment incl. S&F sheet metal box of size 175mmx100mm [16 SWG] with 3mm thick bakelite top cover
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Earthing the installation by 2" ( 50 mm) dia ISI (M) GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed as per G.S. in morrum soil.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as per G S
Connecting the equipments to earth busbar including S & F No.4 SWG GI (Hot Dip) wire of size on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as per GS
Excavation of soil for installation of Earth Electrode and filling & ramming for morrum soil.
Add GST @ 18% on Item no 1 to 28
Add CESS @ 1% on Item no 1 to 29
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.97 MB
BOQ_2389213.xls
BOQ • 0.35 MB
2911.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .