Tender Value
₹36.0 L
EMD Value
₹72,100
Closing Date
27 Feb 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
ELECTG
60 conditions · 15 needing a document upload
Whether Document verification certificate as per standard format uploaded
Whether electrical contractor's license, supervisor's license along with PAN Card of both contractor and supervisor uploaded.
Whether documents related to all mandatory requirements as mentioned in Clause no 5 & 6 of GCC part -I, Clause no 10, 11, 14, 15 & 16 of tender form 2nd sheet have been full filled and uploaded.
Whether documents relating to exemption of payment of EMD enclosed
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer should upload copy of the following documents self-attested / digitally signed by the tenderer or authorized representative of the tendering firm along with the tender. Tenderer(s) can use Standard formats available in the tender documents.
The list of personnel / organization on hand and proposed to be engaged for the tendered work. (Please refer Para-11(iii) of tender form 2nd sheet). Standard format attached as form no.5 in tender documents.
The list of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work. (Please refer Para- 11(iii) of tender form 2nd sheet).
List of works physically completed in the last 03(three) financial years under Govt./Public Sector Units giving description of work, organization for whom executed, approximate value of contract 2.2.1 at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and final value of contract should also be given.
List of works on hand indicating description of work, contract value, approximate value of balance work yet to be done and date of award. (Please refer Para-10.1 of tender form 2nd sheet). Standard format attached as form no.3 in tender documents.
NOTE: Supportive documents/certificates from the organizations with whom they worked/are working should be uploaded. 2.3.1 Certificates from private individuals for whom such works are executed/being executed shall not be accepted. refer clause No.10.1 of IRGCC-2022.
The tenderer should upload the supportive documents against the i)'Type of Firm' as mentioned below: *Sole Proprietorship firm: Notarized affidavit claiming the firm to be a sole proprietor firm * Company: MOA, AOA, Power of Attorney, *Partnership Firm: Deed of Partnership, POA and ii) an undertaking for not being Blacklisted / debarred as per Annexure-A. NOTE: In case of partnership firm, they should submit individual declaration of all partners not being Blacklisted / Debarred as per Annexure-A, otherwise the offer of the tenderer will be summarily rejected.
Each partner of the partnership firm should duly submit the filled in Annexure-V separately as per IRGCC-2022; Otherwise, the offer of the tenderer will be summarily rejected. Firms other than the partnership firm have to submit it as before.
Please upload certificate (Annexure - V(A)) and is to be given by attorney/authorized signatory/ each member of Partnership firm/ Joint Venture (JV)/ Hindu Undivided Family (HUF)/ Limited Liability Partnership (LLP) etc).
The tenderer should upload Declaration regarding "Employment / partnership etc. of Retired Railway Employees" (please refer to Para 16(a) of tender form 2nd sheet). (Use standard "Form no. 2", available in tender booklet).
The tenderer has to upload Declaration regarding relation with any Railway Employees. (Please refer to Para 16 (c) of tender form 2nd sheet). (Use standard "Form no. 6", available in tender booklet).
Should a tenderer or contractor being an individual, have member(s) of his family or in the case of partnership firm / Company / Joint Venture(JV) / registered Society / registered trust etc. one or more of his partner(s) / share holder(s) or member (s) of the family of patterner(s) / share holder (s) having share of more than 1 % in the tendering entity employed in gazetted capacity in the engineering or any other department of the Railway, then the tenderer at the time of submission of tender, will inform the authority inviting tenders the details of such persons.
The tenderer should upload certificate of familiarization as per Chapter -4. (Use standard "Form no. 7", available in tender booklet).
The tenderer should upload GST registration certificate and PAN card.
For all tenders having advertised cost of Rs. 10 lakh or above, the contractor shall have to submit the option to take payment from Railways through a letter or credit (LC arrangement. The tenderer shall affirm having read over and agreed to the terms and condition of the LC option. The option of taking payment through LC arrangement, once exercised by tenderer at the time of bidding, shall be final and no change shall be permitted, therafter, during execution of contract (The tenderer have to submit the option take payment fro Railway through a Letter of Credit arrangement).
The tenderer should upload the bank details i.e. Name of Bank along with Bank Branch Code, Account Number as appearing in the cheque book, IFSC Code and PAN Number, dully certified by the Authorized official of of the bank to facilitate payment through ECS/NEFT/RTGS. In lieu of the bank certificate photocopy /scanned copy of a cancelled cheque and PAN card may be attached for verification of the above particular, otherwise the offer of the tenderer will be summarily rejected.
Construction of Chord line connecting JSG-TIG to TIG-Raipur with2 nos. of junction cabins between SFK-RNBT in Sambalpur division.
SBP-ELECT-2026-T-270
SBP-ELECT-2026-T-270
Open
Works - General
6 Months
Sambalpur, Odisha
₹0
₹72,100
5 Feb 2026
5 Feb 2026
150 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3603609.52 Below/P | ||
| — | 100.00 | — | — | ||
| Concealed wiring for Light/ Fan/ Exhaust Fan/Call Bell/inverter points by 1.5 sq.mm. FRLS Cu. wire with modular switches through PVC pipe with supply of materials. | — | — | — | 54,200 | |
| — | 100.00 | — | — | ||
| Surface wiring for Light/signage/ Fan points by 1.5 sq.mm. FRLS Cu. wire through PVC pipe to ceiling rose with supply of materials for cover shed/ FOB etc. | — | — | — | 37,097 | |
| — | 30.00 | — | — | ||
| Concealed wiring of socket point 6 Amp with copper wire and modular switch and socket with supply of materials. | — | — | — | 4,471.5 | |
| — | 15.00 | — | — | ||
| Concealed wiring of socket points 16 amp with copper wire and modular switch and socket with supply of materials. | — | — | — | 6,674.85 | |
| — | 400.00 | — | — | ||
| Supply of materials and concealed wiring of sub main with 2x (2.5 sq.mm.) +1x (1.5 sq.mm) PVC Cu. FRLS Wire | — | — | — | 43,572 | |
| — | 200.00 | — | — | ||
| supply of materials and concealed wiring of sub main with 2(1x4 sq.mm) + 1x (2.5 sq.mm.) PVC Cu. FRLS Wire from DB to indivisual switch board | — | — | — | 24,996 | |
| — | 200.00 | — | — | ||
| supply of materials and concealed wiring of sub main with 2(1x6 sq.mm) + 1x (2.5 sq.mm.) PVC Cu. FRLS Wire in PVC pipe. | — | — | — | 35,396 | |
| — | 80.00 | — | — | ||
| Supply of 20 W, LED type tube light fitting | — | — | — | 23,616.8 | |
| — | 3.00 | — | — | ||
| Supply of 9 W LED based bulkhead fitting | — | — | — | 2,845.83 | |
| — | 720.00 | — | — | ||
| Supply of 18-watt LED down light fitting complete with luminaire (Unit of Watt may be read as Per Unit). | — | — | — | 50,796 | |
| — | 123.00 | — | — | ||
| Erection, fitting/Down lighter. etc. | — | — | — | 5,822.82 | |
| — | — | — | Light/bulkhead | ||
| — | 35.00 | — | — | ||
| Supply of 1200mm sweep energy efficient BLDC ceiling fan | — | — | — | 80,072.3 | |
| — | 35.00 | — | — | ||
| Fixing and testing of ceiling fan | — | — | — | 1,493.1 | |
| — | 5.00 | — | — | ||
| Supply of 300 mm Exhaust fan | — | — | — | 8,648.35 | |
| — | 5.00 | — | — | ||
| Erection, testing and commissioning of Exhaust fan. | — | — | — | 8,213.35 | |
| — | 100.00 | — | — | ||
| Laying of single cable across the road/Track as per Railway appd. drawing. | — | — | — | 41,796 | |
| — | 5000.00 | — | — | ||
| Supply and laying of 63 mm dia (OD=63 mm &ID=51 mm nominal) DWC HDPE pipe ISI marked along with all accessories etc. | — | — | — | 7,96,200 | |
| — | 5350.00 | — | — | ||
| Laying of Railway supplied cable in air/on wall/pole / through GI Pipe/culvert/cable trench/cable tray/HDPE pipe etc. | — | — | — | 1,23,478 | |
| — | 50.00 | — | — | ||
| Laying of Rly supplied cable on hard surface on platform/any cement concrete. | — | — | — | 15,371.5 | |
| — | 30.00 | — | — | ||
| Supply of 6 mtr GI octagonal pole | — | — | — | 2,13,178.5 | |
| — | 30.00 | — | — | ||
| SITC of Coil Earthing | — | — | — | 4,554.9 | |
| — | 30.00 | — | — | ||
| Supply of 200X100 mm, 11 Mtr RS joist pole | — | — | — | 4,36,733.4 | |
| — | 60.00 | — | — | ||
| Transportation & Erection of Rly. Supplied GI/SST pole/RS joist | — | — | — | 15,774 | |
| — | 51.00 | — | — | ||
| Excavation of earth pit in any kind of soil and casting of foundation for erection of Pole. | — | — | — | 1,68,873.75 | |
| — | 35.00 | — | — | ||
| Supply of 45-watt LED outdoor fitting | — | — | — | 72,459.1 | |
| — | 35.00 | — | — | ||
| Erection, testing & commissioning of LED outdoor fitting on GI pole /SST pole/building front area etc. | — | — | — | 8,778.7 | |
| — | 4.00 | — | — | ||
| Installation, testing & commissioning of1.5-ton split air conditioner | — | — | — | 7,530 | |
| — | 4.00 | — | — | ||
| Metallic Mount Suitable for High Wall Split AC complete | — | — | — | 3,864.12 | |
| — | 4.00 | — | — | ||
| Supply, Erection and commissioning of 16-25A Modular AC starter switch, single phase fitted with PVC modular Box and cover plate | — | — | — | 1,847.48 | |
| — | 3.00 | — | — | ||
| Supply of 4way sheet metallic enclosure for MCB fitted within rail | — | — | — | 1,430.13 | |
| — | 3.00 | — | — | ||
| Erection, testing & commissioning of 4way MCB distribution board. | — | — | — | 138.69 | |
| — | 3.00 | — | — | ||
| Supply & erectionof 8-way MCB distribution Board Sheet steel power coated suitable for MCB's fitted with Bus bar, neutral link, earth bar and Din rail confirming to Is 13032-1991) | — | — | — | 2,521.83 | |
| — | 6.00 | — | — | ||
| SITC of metallic enclosure for 2 pole MCB | — | — | — | 1,883.16 | |
| — | 6.00 | — | — | ||
| SITC of ISI marked 6-32Amp MCB DP with 2PP, 10KA | — | — | — | 3,438.54 | |
| — | 36.00 | — | — | ||
| SITC of ISI marked 6-32Amp MCB SP with10KA | — | — | — | 8,953.2 | |
| — | 700.00 | — | — | ||
| Stringing of Railway supplied 11 KV AB cable | — | — | — | 35,000 | |
| — | 30.00 | — | — | ||
| Supply & erection of suitable hard wares for stringing of AB cable with insulator | — | — | — | 16,325.1 | |
| — | 2.00 | — | — | ||
| Supplydesign & fabrication of suitable LT panel Board consisting ofCopper bus bar 200 Amp.withincoming 1X 100 Amp MCCB 4P Ics 25kA with multi-function energy meter, outgoing :6X40 A MCB, DP, 10kA C-series 5X 32 A MCB, DP 10 k A C-series, 1X 63 Amp MCB, DP 10 k A C- series, 1X 63 Amp MCB, TPN 10 kA C-series, LED type indication lamp for RYB in incoming side in a CRS sheet with double door provision& locking arrangement | — | — | — | 76,530.96 | |
| — | 1.00 | — | — | ||
| Supply of outdoor feeder pillar/ Panel Board having 2x160A MCCB, 16KA as incomer, 200 A copper bus bar, in incoming, 4 X 40-63 A MCCB 16KA, 2x32Amp MCB DP 10KA as outgoing (For MCCB's Ics= 100% Icu) | — | — | — | 1,17,168.76 | |
| — | 3.00 | — | — | ||
| Erection of feeder pillar/wall mounting panel board. | — | — | — | 12,154.95 | |
| — | 16.00 | — | — | ||
| Supply, erection, testing & commissioning of G.I pipe earthing as per CEE approved drawing | — | — | — | 43,147.2 | |
| — | 1.00 | — | — | ||
| Supply of control and distribution panel for CLS supply of 60A, 10KVA, AT as per RDSO spec no. TI/SPC/PSI/CLS/2022 and as per CORE approved latest drawing No. JPE-041-1 sheet 1& 2 | — | — | — | 29,953.3 | |
| — | 1.00 | — | — | ||
| Erection, testing & commissioning of CLS panel | — | — | — | 814.41 | |
| — | 1.00 | — | — | ||
| Junction box comprising bus bar 60 Amp (02 nos.) and 63 Amp MCB DP | — | — | — | 2,210 | |
| — | 2.00 | — | — | ||
| Erection, Testing & commissioning of Railway supplied outdoor distribution transformer 11/0.4KV, 63 KVA (Due to non-availability of rate for 63 KVA transformer, rate of 250 KVA transformer is adopted for rate reference) | — | — | — | 58,626.54 | |
| — | 3.00 | — | — | ||
| Supply of 11KV, 200A gang operated AB switch complete. | — | — | — | 18,615.39 | |
| — | 3.00 | — | — | ||
| Erection, testing & commissioning of AB switch | — | — | — | 4,334.73 | |
| — | 3.00 | — | — | ||
| Supply of 11KV 50A/60A capacity expulsion type drop out fuses complete. | — | — | — | 7,304.55 | |
| — | 3.00 | — | — | ||
| Erection, testing & commissioning of drop out fuse | — | — | — | 1,425.81 | |
| — | 2.00 | — | — | ||
| Supply of 11KV 5/10KA Lightening Arrestor. (1 set=3 nos) | — | — | — | 5,912.94 | |
| — | 2.00 | — | — | ||
| Erection, testing and commissioning of11KV Lightening Arrestor. (1 set=3 nos) | — | — | — | 1,373.8 | |
| — | 36.00 | — | — | ||
| 11KV Disc insulator complete set (Supply& erection) | — | — | — | 14,898.96 | |
| — | 9.00 | — | — | ||
| 11KV Pin/ Post insulator complete set (supply& erection) | — | — | — | 1,369.17 | |
| — | 200.00 | — | — | ||
| Supply of ACSR conductor | — | — | — | 18,672 | |
| — | 200.00 | — | — | ||
| Transportation and stringing of Rly supplied ACSR conductor | — | — | — | 672 | |
| — | 6.00 | — | — | ||
| Stay set complete | — | — | — | 23,669.46 | |
| — | 880.00 | — | — | ||
| Supply, fabrication & erection of G.I. channel of 75x40x4.8mm (7.14Kg/Mtr)/ Supply, fabrication & erection of G.I. angle of 50x50x5mm/2(3.8Kg/mtr)/25x25x5, Supply, erection of G.I. Nuts, bolts, washers etc ofsuitablesize | — | — | — | 79,490.4 | |
| — | 1.00 | — | — | ||
| SITC of substation name board | — | — | — | 2,154.42 | |
| — | 1.00 | — | — | ||
| SITC of protected area Boards | — | — | — | 883.29 | |
| — | 50.00 | — | — | ||
| Construction of cable trench (0.45x0.45 mtr) with bricks, filling of sands and fixing of RCC slab (3") over the cable trench & laying of cable inside it. | — | — | — | 77,725.5 | |
| — | 30.00 | — | — | ||
| Supply & fixing of 65 mm inner dia(medium grade) GI pipe | — | — | — | 18,635.4 | |
| — | 12.00 | — | — | ||
| Supply & fixing of 150 mm inner dia(medium grade) GI pipe | — | — | — | 15,274.8 | |
| — | 4.00 | — | — | ||
| SITC of straight through jointing kit suitable for XLPE cable- 3.5/4 core cable- 50-95 sq.mm. | — | — | — | 16,838.2 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing & commissioning of outdoor cable end termination with heat shrinkable jointing kit (suitable for 3core 35 sq.mm. AB cable of 11 KV grade. | — | — | — | 69,342.4 | |
| — | 50.00 | — | — | ||
| Supplying and making cable route marker with cement concrete 1 :2: 4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. | — | — | — | 17,235.5 | |
| — | 100.00 | — | — | ||
| Supply & fixing of GI Flat | — | — | — | 8,309 | |
| — | 4.00 | — | — | ||
| Supply and spreading of sand | — | — | — | 2,981.68 | |
| — | 3.00 | — | — | ||
| Supply & spreading of 25-40 mm size ballast over substation area and dressing the ballast to a proper profile as instructed by rly site engineer. | — | — | — | 4,416.93 | |
| — | 3.00 | — | — | ||
| Construction/ Repairing/ modification of plinth with C.C(1: 2: 4) | — | — | — | 11,257.47 | |
| — | 50.00 | — | — | ||
| supply & erection of fencing panels at substation | — | — | — | 1,38,817 | |
| — | 1.00 | — | — | ||
| Supply & erection of fencing uprights (ISMC100x50x5 mm @ 9.56KG/mtr | — | — | — | 1,22,319.12 | |
| — | 180.00 | — | — | ||
| Fabrication & erection of iron gate including steel primer painting of size :1.7MX3.5M(In two parts of 1.75M) with locking arrangement. (gate area=5.95sq mtr. Weight of the gate @ 30Kgs/sqmtr=178.5 Kgs) | — | — | — | 26,730 | |
| — | 4.00 | — | — | ||
| Supply & erection of 11 KV danger board in Odia, Hindi & English | — | — | — | 801.88 | |
| — | 60.00 | — | — | ||
| SITC of LED Name board as per RB technical specification circulated vide Letter No.2023/SDII/22/07/02, Dtd.15.05.2023 | — | — | — | 1,83,495.6 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
IRGCCWORKS-2022_compressed.pdf
T-270-TenderBooklet.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .