Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC NO 5 NMK COLONY 1ST CROSS TRICHY 620020 | TRICHY | TRICHY | TAMIL NADU | 620020 | ₹1.6 Cr | L1 | Accepted-AOC L1 negotiated price |
| 2 | L2₹1.6 CrRejected-Finance 57 KAMARAJ STREET KOLAPPALUR GOBICHETTIPALAYAM ERODE 638 456 | GOBICHETTIPALAYAM | ERODE | TAMIL NADU | 638456 | ₹1.6 Cr | L2 | Rejected-Finance Higher rates |
| 3 | L3₹1.6 CrRejected-Finance 3 39 TEACHERS COLONY LALGUDI TRICHY 621 601 | LALGUDI | TIRUCHIRAPPALLI | TAMIL NADU | 621601 | ₹1.6 Cr | L3 | Rejected-Finance Higher rates |
| 4 | L4₹1.7 CrRejected-Finance P NO 94 AGS NAGAR ZAMIN PALLAVARAM CHENNAI 600 117 | CHENNAI | CHENGALPATTU | TAMIL NADU | 600117 | ₹1.7 Cr | L4 | Rejected-Finance Higher rates |
| 5 | Rejected-Technical | - | - | Rejected-Technical BQR condition not satisfied |
| Sl No | Description | Qty | Unit | creepers engineering contractors L3 | SAKTHIVEL L1 | sai pranesh infrastructures L2 | SP TECH ENGINEERING PVT LTD L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Schedule I (Thanjavur 230kV feeder bay) | 1 | No | 52,04,924 ₹52.0 L | 48,65,244.35 ₹48.7 L | 49,69,141 ₹49.7 L | 51,04,341 ₹51.0 L |
| 2.00 | Schedule II (Thiruvarur 230kV feeder bay) | 1 | No | 86,43,784 ₹86.4 L | 85,06,852.1 ₹85.1 L | 84,35,990 ₹84.4 L | 91,55,975 ₹91.6 L |
| 3.00 | Applicable GST Amount (Total GST Amount @18%) | 1 | No | 24,92,767.44 ₹24.9 L | 24,06,977.36 ₹24.1 L | 24,12,923.58 ₹24.1 L | 25,66,856.88 ₹25.7 L |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
14 Jul 2025, 2:00 pmClosed
CE/TP-II/Trichy
Chief Engineer, Transmission Projects-II, TANTRANSCO, Periyamilaguparai, Near Collectorate, Trichy-620001
Supply fabrication and erection of steel Structures, Earthing Steels, Painting, Equipments erection for 2 Nos. 230 kV bay extensions at Vellalaviduthi 400kV SS
2025_EB_573934_1
CE/TP-II/TRY/E-08/25-26
Open Tender
Electrical Works
120 days
Vellalaviduthi, Pudukottai, Trichy
As per tender specification
4 documents required · 4 mandatory
₹0
₹1.3 L
Yes
5 Jun 2026
25 Jun 2025
15 Jul 2025
25 Jun 2025
14 Jul 2025
25 Jun 2025
Amount
Schedule I (Thanjavur 230kV feeder bay)
Schedule II (Thiruvarur 230kV feeder bay)
Applicable GST Amount (Total GST Amount @18%)
Description of Work / Item(s)
Amount
STEELS: Supply of various types of steels including Cost of steel, Freight & Handling confirming to IS 2062 Gr A at site, Fabricating the steels in to specified structures as per the std.design/Drawing, Painting of Primer coat of Redoxide paint and first finishing coat of Aluminium Paint with supply of reputed make paints after proper surface preparation such as cleaning of rust scales using appropriate machinery including all Labour, machinery and Consumables and as directed by the field Engineer at the SS site. Non-specified structures, Extension, Alterations, and Deductions as per station requirement.
Light section (other than heavy section)
Supply of various types of steels including Cost of steel, Freight & Handling confirming to IS 2062 Gr A at site, Fabricating the steels in to specified structures as per the std.design/Drawing, Painting of Primer coat of Redoxide paint with supply of reputed make paints after proper surface preparation such as cleaning of rust scales using appropriate machinery including all Labour, machinery and Consumables and as directed by the field Engineer at the SS site. 230 KV Breaker Platform per phase limb
Labour for the Erection of the fabricated steel structures at the SS site with Supply of GI Bolts, Nuts & Washers (Spring/Flat as required) confirming to IS including Labour, machinery and Consumables as required & as directed by the field Engineer.
Non-specified structures, Extension, Alterations, and Deductions as per station requirement. Light section (other than heavy section)
Other Station Structures - 230 KV Breaker Platform per phase limb
EARTHINGS: Supply of Various types of Steel materials confirming to ISS 2062 –Gr A including, Freight, Handling, etc., at site for Earthing with Labour for Fabrication & erection for Earthing including Labour, Machinary and Consumables as Required and as directed by the Field Engineer.
Labour for excavating and refilling of earth /trench for earthmat, cable, etc., of any size/depth narrow excavation as directed by the field engineer. Normal clay / hard gravel soil
Providing Earth bore 140/150 mm dia using power rig or 100/125 mm dia using hand bore set including the labour, lead, lift etc., sedimentary strata of clay & sand stone shale pebbles boulders etc., for earth Pits with supply and providing of Bentonite powder (Sodium Bentonite) 5Kg /Mtr depth of the bore mixed with low resistivity earths as directed by the field Engineer (Earth to be supplied by the contractor)
Providing Earth bore 140/150 mm dia using power rig or 100/125 mm dia using hand bore set including the labour, lead, lift etc., sedimentary strata of clay & sand stone shale pebbles boulders etc., for earth Pits with supply and providing of Bentonite powder (Sodium Bentonite) 5Kg /Mtr depth of the bore mixed with low resistivity earths as directed by the field Engineer (Earth to be supplied by the contractor)(under LC)
Supply and providing of 450-600 mm dia, 300 mm height, 36 mm thick cement collar for identification of earth electrode location as directed by the field engineer.
HANDLING: Labour for the loading/unloading/shifting of Department materials at stores or site by the Contractor WITHOUT using Board's crane for one operation.
230 KV Isolators
Cables/Conductors including cutting and rewinding
Busbars
230 KV Breaker
230/110 KV CT/PT/LAS/CVT/CC/WT/ Others
230 KV Insulators
33/22/11 KV Insulators
AC/DC/C&R Panels of Non grid type, Single feeder Control/Relay Panels of Grid type
BUS RELATED: Labour for the Erection of Strung bus and all related hardwares, fittings, clamps including Meggering, hoisting of insulators and consumables and as directed by the field engineer.
230 KV Double Conductor Strung Bus/phase
230 KV Double Conductor Strung Bus/phase (under LC)
Labour for the erection of Insulator single pole stack for supports/Underhang including Meggering & other consumables and as directed by the field engineer. 230KV
Labour for the erection of Busbar including suitable Modifications of End Clamps, providing holes wherever necessary as directed by the field engineer.
75 mm (1 length)
75 mm with bend (1 length)
Labour for the Erection of Jumper/ Droppers using Moose/Zebra/panther Conductors including Modification of End clamps, providing holes etc wherever necessary as directed by the field engineer.
Labour for the Erection of Jumper/ Droppers using Moose/Zebra/panther Conductors including Modification of End clamps, providing holes etc wherever necessary as directed by the field engineer.(under LC)
STRINGING HARDWARES: Supply of Stringing Hardware for 245kV Double Tension Insulator String assembly with double anchoring for 2x15 discs with subconductor spacing 225mm suitable for twin ACSR Moose conductor with turn Buckle
Supply of Stringing Hardware for 245kV Double Tension Insulator String assembly with double anchoring for 2x15 discs with subconductor spacing 225mm suitable for twin ACSR Moose conductor without turn Buckle
Supply of Stringing Hardware for 245kV both side Bolted type Tension Clamp for Mid span Isolation suitable for Twin Moose conductor (sub -conductor spacing 225 mm)
Supply of Stringing Hardware for 245kV Single suspension insulator string assembly for 1x15 discs with sub conductor spacing 225mm suitable for twin ACSR Moose conductor with drop clamp
POWER CONNECTORS: Supply & Fixing of Aluminium Power Connectors/ Clamps/ Fittings with SS Bolts and Nuts, including, frieght etc., confirming to IS as per the drawing and specification.
245kV, 2000A Circuit Breaker Connector: Suitable for 3" IPS Al Tube expansion type
245kV, 2000A Current Transformer Connector: suitable for 3" IPS Al Tube rigid type
245kV, 2000A Current Transformer Connector: Suitable for twin Moose ACSR horizontal approach
245kV, PT Connector: suitable for Twin moose ACSR Universal Approach
216 kV Surge Arrestor Connector: suitable for Twin moose ACSR Horizontal Approach
245kV, 2000A HDB Isolator Connector: Suitable for 3" IPS Al Tube expansion type
245kV, 2000A HDB Isolator Connector: Suitable for twin Moose ACSR horizontal approach
245kV PI Connector: suitable for 3" IPS Al.Tube EXPANSION type with tube break
245kV TEE connector suitable for Single Zebra run and twin Moose ACSR tap
Switch End Clamp for 75mm Bus
Seating Block for 75mm Busbar
T Clamp for 75mm Bus to double Moose
T clamp for Moose to Moose
T clamp for twin moose to single moose
PG Clamp for Moose
75mm Corona Bell
Spacer Clamp for Twin Moose (225 mm spacing)
OUTDOOR BREAKERS: Labour for erection of Breaker using crane arranged by the Contractor including the cost of gada cloth taflan tape and other consumables including support structure providing holes, gas filling wherever necessary as directed by the field engineer. 230 KV Breaker
MEASURMENT TRANSFORMERS: Labour for erection of Measurement transformers, reactor units, using Crane arranged by the Contractor including providing holes wherever required as directed by the field engineer. 230 KV
ISOLATORS & HG FUSE SET: Labour for erection of Isolators with proper allingments including accessories, Meggering and cost of consumables and lubricants and as directed by the field engineer.
230 KV with Earth - Motor operated
230 KV without Earth - Motor operated
230 KV without Earth - Motor operated in Elevated stuctures
230 KV without Earth - Motor operated in Elevated stuctures(under LC)
LAS: Labour for erection of LAS station/ Distribution type single unit including monitors & accessories. 230 KV
CONTROL ROOM MATERIALS: Labour for the Erection of Control Panels includings consumables as directed by the field engineer. Simplex type/AC/DC/C&R Panel of Non-Grid type, Battery Chargers, Single feeder Control/ Relay Panels of Grid type (P&C)
Supply and Erection of AC Junction Box (FRP) with required no of 3PH MCB, Single Ph MCB, suitable fuse, Bus arrangement for supply distribution,Lighting arrangement for the kiosk & 1 No 15 A single Phase socket as required for the SS and as directed by the field Engineer.
Supply and Erection of DC Interlock Box (FRP) with required no of MCBs, suitable fuse, Bus arrangement for supply distribution, Lighting arrangement for the kiosk as required for the SS and as directed by the field Engineer.
Labour for erection of C.T/P.T junction box
PAINTING: Supply and Labour for the Second Finish Coat of Aluminium paint on standard Steel Structures including cost of Paints of reputed make, Consumables etc., as directed by the field Engineer. Non-specified structures, Extension, Alterations, and Deductions as per station requirement. Light section (other than heavy section)
Labour charges for two coats of enamel painting in substation structures, steels etc., including the cost of reputed make paints and other consumables as directed by the field engineer. 230 KV Breaker Platform per phase limb
Supply & Labour charges for two coats of enamel painting in any substation structures, steels, etc and wherever required including the cost of reputed make paints and other consumables as directed by the field engineer.
Labour charges for writing details in any finished surface/board including cost of enamel paints and other consumables as directed by the field engineer.
CABLES: Labour for erection of cable in duct/ trench/ clamping on structures - neat laying in the ducts with identification Aluminium tags in all duct corners for easy identification of cables including fabrication of clamps and fixing at uniform intervals as directed by the field engineer
Up to 8 Core
Above 8 Core
STATION ACCESSORIES: Providing PVC down fall pipe using 110mm dia 4Kg/sqcm, PVC pipe and PVC clamp line supreme ec, including fixing PVC washer type door bend & shoe, in correct position and connecting from the roof slab including cost of all materials, labour, transport lead, lift, etc., complete, including PVC accessories and washers as required and as directed by the field engineer.
Supply and glanding of ISI mark cable gland of suitable size of reputed make including removing of insulation of cables and providing suitable holes as required and as directed by the field engineer.
Labour for erection of cable end glands
Supply and termination of cable core end dressed neatly including the cost of cable socket (lug) ferrules, sleeves, tags, ties, stropes, etc., as directed by the field engineer. (No.of core ends in unit of 1000).
Supply and erection of Vinyl Sticker cutting/ Printing on Vinyl Sticker/Foam board to be used for main equipment, slogan, name board & any other purpose of required sizes as directed by the field engineer.
Supply and erection of "B" class G.I.pipe for extension of tandem/down pipe for A.B.Switches and for any other work required as directed by the field engineer.
32 mm Dia
40 mm Dia
50 mm Dia
Supply and provision of 12/25x3mm , 30X5 mm flexible braided tinned copper / tinned copper flats as required and as directed by the field engineer.
Supply &Crimping of Copper Lugs of Suitable sizes as required and as directed by the field engineer.
Supply and fixing Fuse unit of reputed make with ISI as directed by the field engineer including drilling &fixing. HRC Backlite Fuse units 16 AMPS
Supply and fixing of HRC fuse of reputed make as directed by the field engineer. 2/5/10/16 AMPS
Supply and fixing of Hylem board 8/10 mm thick wherever required as directed by the field engineer.
Supply and fixing of MCB of Havells/Schneider/ MDS/ Reputed make with ISI mark wherever required as directed by the field engineer.
32 AMPS - 3 phase, 4 pole
63 AMPS - 3 phase, 4 pole
16 AMPS - single phase, single pole
Supply and fixing of Terminal blocks as directed by the field engineer. Disconnecting type (Link type)
Supply and provision of M8,M10,M12 and M16 (full /Half thread) G.I.bolt and nuts of various sizes including plate/ spring washers as required and as directed by the field engineer.
Supply and fixing of godrej 6 lever long shackle navtol lock with triplicate keys for A.B.Switches and for any other purpose including the cost of ring and key token as directed by the field Engineer.
Transportation: Transportation of Department materials by the Contractor from any department stores to site or as directed by the field Engineer. Damages if any will be recovered from the contractor. Hire charges per day for 1No. Diesel driven vehicle upto 24hrs a day normally upto 100kms
Hire charges upto 100kms
kilometer charges in excess of 100 kms in a day additional charges per km
Retention charges beyond 24 Hours a day
From 1Hour to 6Hours - 25% of hire charges
From 6Hours to 8Hours - 50% of hire charges
From 8Hours and above - oneday hire charges
Insurance coverages for transporting of Equipments for both fragile and Non-fragile from Store to site
Description of Work / Item(s)
Amount
STEELS: Supply of various types of steels including Cost of steel, Freight & Handling confirming to IS 2062 Gr A at site, Fabricating the steels in to specified structures as per the std.design/Drawing, Painting of Primer coat of Redoxide paint and first finishing coat of Aluminium Paint with supply of reputed make paints after proper surface preparation such as cleaning of rust scales using appropriate machinery including all Labour, machinery and Consumables and as directed by the field Engineer at the SS site. Non-specified structures, Extension, Alterations, and Deductions as per station requirement.
Light section (other than heavy section)
Supply of various types of steels including Cost of steel, Freight & Handling confirming to IS 2062 Gr A at site, Fabricating the steels in to specified structures as per the std.design/Drawing, Painting of Primer coat of Redoxide paint with supply of reputed make paints after proper surface preparation such as cleaning of rust scales using appropriate machinery including all Labour, machinery and Consumables and as directed by the field Engineer at the SS site. 230 KV Breaker Platform per phase limb
Labour for the Erection of the fabricated steel structures at the SS site with Supply of GI Bolts, Nuts & Washers (Spring/Flat as required) confirming to IS including Labour, machinery and Consumables as required & as directed by the field Engineer.
Non-specified structures, Extension, Alterations, and Deductions as per station requirement. Light section (other than heavy section)
Other Station Structures: 230 KV Breaker Platform per phase limb
Supply and fabrication and erection of Galvanized Iron eye bolts/ grout bolt with 20/22 mm rod confirming to IS with proper threading and 2 nos MS Nuts as directed by the field Engineer Grout Bolt
EARTHINGS: Supply of Various types of Steel materials confirming to ISS 2062 –Gr A including, Freight, Handling, etc., at site for Earthing with Labour for Fabrication & erection for Earthing including Labour, Machinary and Consumables as Required and as directed by the Field Engineer.
Labour for excavating and refilling of earth /trench for earthmat, cable, etc., of any size/depth narrow excavation as directed by the field engineer. Normal clay / hard gravel soil
Providing Earth bore 140/150 mm dia using power rig or 100/125 mm dia using hand bore set including the labour, lead, lift etc., sedimentary strata of clay & sand stone shale pebbles boulders etc., for earth Pits with supply and providing of Bentonite powder (Sodium Bentonite) 5Kg /Mtr depth of the bore mixed with low resistivity earths as directed by the field Engineer (Earth to be supplied by the contractor)
Supply and providing of 450-600 mm dia, 300 mm height, 36 mm thick cement collar for identification of earth electrode location as directed by the field engineer.
HANDLING: Labour for the loading/unloading/shifting of Department materials at stores or site by the Contractor WITHOUT using Board's crane for one operation.
230 KV Isolators
Cables/Conductors including cutting and rewinding
Busbars
230 KV Breaker
230/110 KV CT/PT/LAS/CVT/CC/WT/ Others
230 KV Insulators
33/22/11 KV Insulators
AC/DC/C&R Panels of Non grid type, Single feeder Control/Relay Panels of Grid type
BUS RELATED: Labour for the Erection of Strung bus and all related hardwares, fittings, clamps including Meggering, hoisting of insulators and consumables and as directed by the field engineer.
230 KV Double Conductor Strung Bus/phase
230 KV Quad Conductor Strung Bus/phase (under LC)
Labour for the erection of Insulator single pole stack for supports/Underhang including Meggering & other consumables and as directed by the field engineer. 230KV
Labour for the erection of Busbar including suitable Modifications of End Clamps, providing holes wherever necessary as directed by the field engineer.
75 mm (1 length)
75 mm with bend (1 length)
Labour for the Erection of Jumper/ Droppers using Moose/Zebra/panther Conductors including Modification of End clamps, providing holes etc wherever necessary as directed by the field engineer.
STRINGING HARDWARES: Supply of Stringing Hardware for 245kV Double Tension Insulator String assembly for 2x15 discs with subconductor spacing 225mm suitable for quad ACSR Moose conductor with turn Buckle
Supply of 245kV Double tension insulator String assembly for 2x15 discs with subconductor spacing 225mm suitable for quad ACSR Moose conductor with out turn Buckle
Supply of 245kV Single suspension insulator string assembly for 1x15 discs with sub conductor spacing 225mm suitable for quad ACSR Moose conductor with through clamp
Supply of 245kV Double Tension Insulator String assembly with double anchoring for comprising of 2x15 discs with subconductor spacing 225mm suitable for twin ACSR Moose conductor with turn Buckle
Supply of Stringing Hardware for 245kV Double Tension Insulator String assembly with double anchoring for 2x15 discs with subconductor spacing 225mm suitable for twin ACSR Moose conductor without turn Buckle
Supply of Stringing Hardware for 245kV both side Bolted type Tension Clamp for Mid span Isolation suitable for Twin Moose conductor (sub -conductor spacing 225 mm)
Supply of Stringing Hardware for 245kV Single suspension insulator string assembly for 1x15 discs with sub conductor spacing 225mm suitable for twin ACSR Moose conductor with drop clamp
POWER CONNECTORS: Supply & Fixing of Aluminium Power Connectors/ Clamps/ Fittings with SS Bolts and Nuts, including, frieght etc., confirming to IS as per the drawing and specification.
245kV, 2000A Circuit Breaker Connector: Suitable for 3" IPS Al Tube expansion type
245kV, 2000A Current Transformer Connector: suitable for 3" IPS Al Tube rigid type
245kV, 2000A Current Transformer Connector: Suitable for twin Moose ACSR horizontal approach
245kV, PT Connector: suitable for Twin moose ACSR Universal Approach
216 kV Surge Arrestor Connector: suitable for Twin moose ACSR Horizontal Approach
245kV, 2000A HDB Isolator Connector: Suitable for 3" IPS Al Tube expansion type
245kV, 2000A HDB Isolator Connector: Suitable for twin Moose ACSR horizontal approach
245kV PI Connector: suitable for 3" IPS Al.Tube EXPANSION type with tube break
245kV TEE connector suitable for Single Zebra run and twin Moose ACSR tap
Switch End Clamp for 75mm Bus
Seating Block for 75mm Busbar
T Clamp for 75mm Bus to double Moose
T clamp for Moose to Moose
T clamp for twin moose to single moose
PG Clamp for Moose
75mm Corona Bell
Spacer Clamp for Twin Moose (225 mm spacing)
Spacer Clamp for Quad Moose (225 mm spacing)
OUTDOOR BREAKERS: Labour for erection of Breaker using crane arranged by the Contractor including the cost of gada cloth taflan tape and other consumables including support structure providing holes, gas filling wherever necessary as directed by the field engineer. 230 KV Breaker
MEASURMENT TRANSFORMERS: Labour for erection of Measurement transformers, reactor units, using Crane arranged by the Contractor including providing holes wherever required as directed by the field engineer. 230 KV
ISOLATORS & HG FUSE SET: Labour for erection of Isolators with proper allingments including accessories, Meggering and cost of consumables and lubricants and as directed by the field engineer.
230 KV with Earth - Motor operated
230 KV without Earth - Motor operated
230 KV without Earth - Motor operated in Elevated stuctures
LAS: Labour for erection of LAS station/ Distribution type single unit including monitors & accessories. 230 KV
CONTROL ROOM MATERIALS: Labour for the Erection of Control Panels includings consumables as directed by the field engineer. Simplex type/AC/DC/C&R Panel of Non-Grid type, Battery Chargers, Single feeder Control/ Relay Panels of Grid type (P&C)
Supply and Erection of GI pipe 5m Grouting type lamp post of B class MS pipe (3 inch dia for 3mtrs & 2.5inch dia for 2mtrs) including single/double fitting (Straight or 'V' type) fixing arrangements, 1 inch dia B class pipe arms, yard light box fixing flat
Supply and Erection of No.6 swg GI Solid wire for earthing or any other purpose as directed by the field Engineer
Supply and Erection of reputed make Flood LED light fitting with 275 W, 240V CGL/ PHILIPS/ Bajaj make.
Supply and Erection of reputed make street LED light fitting with 120 W, 240V CGL/ PHILIPS/Bajaj make.
Supply of Erection of yard light fuse unit mounting box of size 200x200x150mm (BxHxD) out of 18 SWG (1.22mm) M.S Sheet including primer paint as per Drawing including the Supply, Fabrication and Erection of Box fixing Flat using 50x8MSF, Two coat of enamel paints, provided with 16/20A rewirable Porcelain Fuse carrier unit, 16 A Bakelite connenectors including its cost materials, consumables, frieght, etc and as directed by the fiels engineer on site requirements. (The box shall be vermin proof, shall be provided with sturdy hinges, with provision for cable entry and locking arangements).
Fabrication, supply and fixing of C.T/P.T/YL junction box of size 400x300x150 mm of 16 SWG(1.6mm) M.S.sheet with primer coat paint, Supply, Fabrication and erection of Box fixing Flats using 50x8 MSF, Supply and Fixing of 25x3mm² Braided Flexible Copper loops to box earth., Two coat of Enamel Paint, provision for fixing terminal blocks/ MCBs including consumables, fright, etc., as directed by the field engineer on site requirements. (The box shall be vermin proof shall have sturdy hinges, & locking arrangements)
Supply and Erection of AC Junction Box (FRP) with required no of 3PH MCB, Single Ph MCB, suitable fuse, Bus arrangement for supply distribution,Lighting arrangement for the kiosk & 1 No 15 A single Phase socket as required for the SS and as directed by the field Engineer.
Supply and Erection of DC Interlock Box (FRP) with required no of MCBs, suitable fuse, Bus arrangement for supply distribution, Lighting arrangement for the kiosk as required for the SS and as directed by the field Engineer.
Labour for erection of C.T/P.T junction box
PAINTING: Supply and Labour for the Second Finish Coat of Aluminium paint on standard Steel Structures including cost of Paints of reputed make, Consumables etc., as directed by the field Engineer. Non-specified structures, Extension, Alterations, and Deductions as per station requirement. Light section (other than heavy section)
Labour charges for two coats of enamel painting in substation structures, steels etc., including the cost of reputed make paints and other consumables as directed by the field engineer.
230 KV Breaker Platform per phase limb
Yard Light Pole Bottom
Supply & Labour charges for two coats of enamel painting in any substation structures, steels, etc and wherever required including the cost of reputed make paints and other consumables as directed by the field engineer.
Labour charges for writing details in any finished surface/board including cost of enamel paints and other consumables as directed by the field engineer.
Cable Tray
Supply of GI Ladder type Cable tray 2.5 m L, 0.6 m W with coupling plate and bolt nuts
Supply of GI Ladder type Cable tray 2.5 m L, 0.45 m W with coupling plate and bolt nuts
Supply of GI Ladder type Cable tray 2.5 m L, 0.3 m W with coupling plate and bolt nuts
Erection of GI Ladder type Cable tray 2.5 m L, 0.6 m W with coupling plate and bolt nuts
Erection of GI Ladder type Cable tray 2.5 m L, 0.45 m W with coupling plate and bolt nuts
Erection of GI Ladder type Cable tray 2.5 m L, 0.3 m W with coupling plate and bolt nuts
CABLES: Labour for erection of cable in duct/ trench/ clamping on structures - neat laying in the ducts with identification Aluminium tags in all duct corners for easy identification of cables including fabrication of clamps and fixing at uniform intervals as directed by the field engineer
Up to 8 Core
Above 8 Core
STATION ACCESSORIES: Providing PVC down fall pipe using 110mm dia 4Kg/sqcm, PVC pipe and PVC clamp line supreme ec, including fixing PVC washer type door bend & shoe, in correct position and connecting from the roof slab including cost of all materials, labour, transport lead, lift, etc., complete, including PVC accessories and washers as required and as directed by the field engineer.
Supply and glanding of ISI mark cable gland of suitable size of reputed make including removing of insulation of cables and providing suitable holes as required and as directed by the field engineer.
Labour for erection of cable end glands
Supply and termination of cable core end dressed neatly including the cost of cable socket (lug) ferrules, sleeves, tags, ties, stropes, etc., as directed by the field engineer. (No.of core ends in unit of 1000).
Supply and erection of Vinyl Sticker cutting/ Printing on Vinyl Sticker/Foam board to be used for main equipment, slogan, name board & any other purpose of required sizes as directed by the field engineer.
Supply and erection of "B" class G.I.pipe for extension of tandem/down pipe for A.B.Switches and for any other work required as directed by the field engineer.
32 mm Dia
40 mm Dia
50 mm Dia
Supply and provision of 12/25x3mm , 30X5 mm flexible braided tinned copper / tinned copper flats as required and as directed by the field engineer.
Supply &Crimping of Copper Lugs of Suitable sizes as required and as directed by the field engineer.
Supply and fixing Fuse unit of reputed make with ISI as directed by the field engineer including drilling &fixing. HRC Backlite Fuse units 16 AMPS
Supply and fixing of HRC fuse of reputed make as directed by the field engineer. 2/5/10/16 AMPS
Supply and fixing of Hylem board 8/10 mm thick wherever required as directed by the field engineer.
Supply and fixing of MCB of Havells/Schneider/ MDS/ Reputed make with ISI mark wherever required as directed by the field engineer.
32 AMPS - 3 phase, 4 pole
63 AMPS - 3 phase, 4 pole
16 AMPS - single phase, single pole
Supply and fixing of Terminal blocks as directed by the field engineer. Disconnecting type (Link type)
Supply and provision of M8,M10,M12 and M16 (full /Half thread) G.I.bolt and nuts of various sizes including plate/ spring washers as required and as directed by the field engineer.
Supply and fixing of godrej 6 lever long shackle navtol lock with triplicate keys for A.B.Switches and for any other purpose including the cost of ring and key token as directed by the field Engineer.
Transportation: Transportation of Department materials by the Contractor from any department stores to site or as directed by the field Engineer. Damages if any will be recovered from the contractor. Hire charges per day for 1No. Diesel driven vehicle upto 24hrs a day normally upto 100kms
Hire charges upto 100kms
kilometer charges in excess of 100 kms in a day additional charges per km
Retention charges beyond 24 Hours a day
From 1Hour to 6Hours - 25% of hire charges
From 6Hours to 8Hours - 50% of hire charges
From 8Hours and above - oneday hire charges
Insurance coverages for transporting of Equipments for both fragile and Non-fragile from Store to site
sai pranesh infrastructures (BID ID -1400810)
creepers engineering contractors (BID ID -1399246)
SP TECH ENGINEERING PVT LTD (BID ID -1400829)
sai pranesh infrastructures (BID ID -1400810)
SP TECH ENGINEERING PVT LTD (BID ID -1400829)
creepers engineering contractors (BID ID -1399246)
SAKTHIVEL (BID ID -1399903)
creepers engineering contractors (BID ID -1399246)
SP TECH ENGINEERING PVT LTD (BID ID -1400829)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid