Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.6 L+₹2.3 L (9.16%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹30.6 L+₹5.3 L (20.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹32.5 L+₹7.2 L (28.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹38.1 L+₹12.9 L (50.8%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
25 Oct 2022, 6:00 pmClosed
GE 881 EWS C/O 56 APOGE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
PERIODICAL SERVICES TO CERTAIN BUILDINGS IN VARIOUS UNITS AT POONCH AND REPAIR/ MAINT OF LT OVER HEAD CONDUCTOR, UNDERGROUND CABLE, LT PANEL AND ALLIED ACCESSORIES IN THE AOR OF AGE B/R-II UNDER GE 881 EWS
2022_MES_554618_1
GE/PNH-57/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹70,000
Yes
22 Dec 2022
27 Sept 2022
1 Nov 2022
27 Sept 2022
25 Oct 2022
12 Oct 2022
Amount
B&R PORTION:- M&L for preparation of old plastered/ un-plastered wall surfaces including brooming down or steel wire brushing, scraping down, smoke soot, mould, moss, efflorescent salts, trading oil and greasy spots, and applying one coat of white wash on walls including cornices, pilasters etc, complete all as specified and directed.
All as per item No. 01 above, but on ceiling, complete all as specified and directed.
All as per item No- 01 above but applying one coat of oil bound distemper white or any tint, complete all as specified and directed
All as per item No- 01 above but applying one coat of oil bound distemper white or any tint on ceiling, complete all as specified and directed.
All as per item No- 01 above but applying two coats of oil bound distemper white or any tint on wall, complete all as specified and directed.
All as per item No- 01 above but applying two coats of Apex paint any tint, complete all as specified and directed.
M&L for complete removal of existing treatment, preparing surfaces plastered or unplastered old surfaces but applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS- 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed.
M&L for applying two layer of wall care putty of approved make of 1mm thick on walls as per manufacturar instructions with and including rubbing by means of sand / abrasive paper to have smooth finishing to receive primer / paint, complete all as specified and directed.
M&L for preparation of old painted wooden or wood based surfaces of any description not otherwise described, over 10cm width or girth including knotting and stopping as required and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint in camouflage pattern/single shade, complete all as specified and directed.
M&L for preparation of old surfaces of wall and applying interior texture wall painting on wall surface with stencil for smooth finish, complete all as specified and directed.
Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
M&L for 15mm thick cement plaster rendering in CM 1:4 on fair faces of bricks or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on other than fair faces of brick or stone masonry wall surfaces & finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of new plaster or unplastered surfaces of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS- 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new surfaces on walls complete all as specified and directed.
M&L for Preparation of new plastered / unplastered surface of wall including cornices pilaster etc, and applying two coats of oil bound distemper, complete as specified and directed.
M&L for preparation of old or new plastered surfaces of wall by brooming down or steel wire brushing, scrapping down smokw soot, moulds moss and efflorescent salts and trading oil and greasy spots and applying two coats of oil bound distemper in camouflage pattern on walls complete all as specified and directed.
E/M PORTION:- Excavation in trenches not exc. 1.5 m wide and not exc. 1.5m in depth for foundation of poles, stay assembly etc and getting out in hard/ dense soil complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and exc. 1.5m in depth for foundation of poles, stay assembly etc and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in surplus spoil including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cable providing with a layer of Sand 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : Punning thickness of 18 cm will be measured for payment purpose)
M&L for burnt bricks locally available, sub class 'B', laid flat for protection of under ground cable complete all as specified and directed at site.
Supply, laying , jointing and testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 185 sqmm 3.5 core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts including cable gland of suitable sizes and aluminium lugs for connection, including taking down old cable any type complete all as specified and directed. Note: Excavation, earthwork, sand cushioning, brick protection shall be measured & paid for separately.
All as per Item No 24 above but size 3.5 core 150 sqmm complete all as specified and directed.
All as per Item No 24 above but size 3.5 core 120 sqmm complete all as specified and directed.
All as per Item No 24 above but size 3.5 core 95 sqmm complete all as specified and directed.
All as per Item No 24 above but size 3.5 core 70 sqmm complete all as specified and directed.
All as per Item No 24 above but size 3.5 core 50 sqmm complete all as specified and directed.
All as per Item No 24 above but size 3.5 core 35 sqmm complete all as specified and directed.
All as per Item No 24 above but size 4 core 25 sqmm complete all as specified and directed.
All as per Item No 24 above but size 4 core 16 Sqmm complete all as specified and directed.
All as per Item No 24 above but size 2 core 10 Sqmm complete all as specified and directed.
Taking out old unsv pole and Supplying, installation and erection in true vertical position steel tubular swaged welded pole, 9.0 metre long, conforming to IS-2713 part-II, type 410 SP-31, complete with cast iron/MS base plate 6mm thick and of size 300x300mm, finial taper, pole cap, bolts, nuts, washers & screws etc., pole made out of ERW Mild steel tubing tubing including holes of required Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint on exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bands at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No with black paint by stenciled letters/figures of 8cm height, complete all as specified and directed. Note: Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately in respected items.
Dismantling of cross arms, bracings, supports, clamps etc of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed.
M&L for cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers, welding , bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated or directed and inclusive of one primer coat and two coats of alluminium paint complete all as specified and directed.
S&F in repair pin type insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100 volt grade, complete all as specified and directed.
S&F in repair for shackle type porcelain , vitreous white, brown or green insulator including galvanised mild steel straps, wahsers, insulator bolts, wahsers and nuts, as working pressure 1100 volts height in 100 mm maximum dia 115 mm section of straps in 31 x 5 mm dia of bolts 14 mm complete all as specified and directed.
S&F in repair stay assembly comprising of MS stay plate of size 30cmx30cmx6mm thick, stay rod with nuts 215cm long, 20mm dia, MS/GI stay bow 40 cm length with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm, loop insulation size 90mmx140mm clearance of hole 25.5 mm & other accessories all as per SSR Part-1, Plate No.1 including necessary MS clamps, excavation earth work & PCC work complete all as specified and directed.
Supply and fixing in repair galvanised stay strand, size 7/3.15 mm for connecting stay assembly with MS clamps on poles complete all as specified and directed.
Supply and fixing in repairs loop insulator porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, large size with overall dimensions 90mm x 140mm, clearance of hole 25.5 mm, Complete all as specified and directed.
S&F in repair cradle hexagonal , rectangular fabricated with GI wire 3.15 / 4 mm dia on existing OH line, complete all as specified and directed.
M&L for dismantling of ACSR conductors and removing from the site complete all as specified and directed.
Supply, stringing, stretching and binding with insulator, ACSR conductor of adequate size (Weasel /ferret/Mink) on LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc complete all as specified and directed.
Trimming of tree branches coming in proximity to LT over head lines and involved with over head lines where detected , over head lines to be cleared of tree branches atleast 2.5 Mtrs apart from ACSR conductor from all sides complete all as specified and directed. Note: Contactor is supposed to manage long wooden ladder atleast 32 feet height, rope and handsaw machine to clear the lines from tree branches having girth upto 6" dia at his own arrangement and cost.
M&L for Re-stretching of loose over head ACSR conductor of any type including GI wire and repair of the broken conductors and adding new length( if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire complete all as specified and directed. Note: Old conductor shall be reused where required for repairing broken length of conductor as directed by Engr-in-charge. Note: Five lines together will be measured as one span from pole to pole.
M&L for painting to steel poles including cross arms, 'V' brackets, 'D' clamps, nuts, bolts, complete including painting with five strips of 30cm each black and white paint in alternate strips from the base of pole upto 1.5mtr height complete, spray painting with two coat of synthetic enamel paint of first quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching, rubbing complete all as specified and directed.
S&F in repair Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed. NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
S&F in repair Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized iron pipe 15 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed. NOTE: The unit rate includes earth wire and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
S&F in repair Single pointed air termination Aluminium rod 12mm dia, 300 mm long complete all as specified and directed.
S&F in repair Test point terminal block made of gun metal or phosphorous bronze of size 75x75 x 25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to GI pipe/ wall for protection of test point complete all as specified and directed.
S&F in repair galvanised iron tubing 'medium grade' with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete of size 40 mm bore, complete all as specified and directed.
S&F in repair aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawl plugs etc for conductor for roof and fixed on wall upto test point, complete all as specified and directed.
S&F in repair Galvanized iron strip 32 x 6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe, complete all as specified and directed. NOTE : Excavation & earth work shall be measured and paid for seperately under relevant item of schedule.
S&F in repair galvanised iron tubing 'light grade' with all fittings and fixed to poles, walls etc. with flat iron clamps/ bolts/ nuts /washers or laid in floors/under roads complete of size 40 mm bore,complete all as specified and directed.
S&F in repair galvanised iron tubing 'light grade' with all fittings and fixed to poles, walls etc. with flat iron clamps /bolts /nuts /washers or laid in floors/under roads complete of size 80 mm bore, complete all as specified and directed.
M&L for painting of LT panel including preparation of old surfaces by scrapping old paint completely and applying two coats of super enameled paint over a coat of red oxide primer complete all as specified and directed.
S&F in repair MCCB, 3 pole, 63 Amps, 415 volts, fixed type with breaking capacity 16 KA Ics=75% Icu, complete all as specified and directed.
S&F in repair MCCB, 3 pole, 160 Amps, 415 volts, adjustable type, with breaking capacity 25 KA Ics=100% Icu, complete all as specified and directed.
S&F in repair MCCB, 3 pole, 200 Amps, 415 volts, adjustable type with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed.
S&F in repair MCCB, 3 pole, 250 Amps, 415 volts, adjustable type with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed.
S&F in repair MCCB, 3 pole, 400 Amps, 415 volts, adjustable type with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed.
S&F in repair aluminium thimble suitable for LT XLPE cable 185 sqmm size, complete all as specified and directed.
S&F in repair aluminium thimble suitable for LT XLPE cable 120 sqmm size, complete all as specified and directed.
S&F in repair aluminium thimble suitable for LT XLPE cable 95 sqmm size, complete all as specified and directed.
S&F in repair aluminium thimble suitable for LT XLPE cable 70 sqmm size, complete all as specified and directed.
S&F in repair aluminium thimble suitable for LT XLPE cable 50 sqmm size, complete all as specified and directed.
S&F in repair aluminium thimble suitable for LT XLPE cable 35 sqmm size, complete all as specified and directed.
S&F in repair aluminium thimble suitable for LT XLPE cable 25 sqmm size, complete all as specified and directed.
M&L for plain cement concrete 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete (1:4:8) Type D-2 (using 40mm graded crushed stone aggregates) as in foundation for steel tubular poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed.
M&L for plain cement concrete (1:2:4) Type B-1 using 20 mm graded crushed stone aggregates, as in coping of steel tubular poles foundation for steel tubular poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed.
S&F in repair rubber insulating mat of size 2mx1mx2.5mm thick, ISI marked, complete all as specified and directed.
S&F in repair PVC spiral line spacer for LT over head line on 9.0 mtrs pole suitable for 2/3/4 wire, complete all as specified and directed.
S&F in repair LT AB cable of size 3x35 sqmm twisted alround the bar messenger of 1x25 sqmm , made out of aluminium stranded circular compacted conductor, XLPE insulated all as per IS : 14255, IS 398 part-IV 7098 part-I including suspension clamp with eye hook at every 35 to 40 mtr span mounted on pole by means of MS clamp, complete all as specified & directed.
Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified and directed.
M/S Chib Engineers
M/S Farooq Ahmed Bhat
M/S KEWAL KRISHAN SANJEEV KUMAR VAID
Jiwan Singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .