Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹15.4 L+₹1.9 L (14.2%)Rejected-Finance 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L2 | Rejected-Finance High Rate | |
| 3 | L3₹19.5 L+₹6.0 L (44.8%)Rejected-Finance 54 10 SHANTI NAGAR NEAR SHINDE CHATRI WANAVADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L3 | Rejected-Finance High Rate | |
| 4 | Rejected-Technical N A | NA | NA | 121004 | - | Rejected-Technical Not recommended since firm has not deposited the aforesaid amount equal to earnest money after revocation of tender |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
26 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8305 REPAIRS/REPLACEMENT AND CLEANING OF SEWAGE LINE, SEPTIC TANKS, SOAKAGE PITS AND COVER SLAB/MAN HOLE COVERS OF OTHER THAN AFMC UNDER GE (CENTRAL) PUNE
2022_MES_520665_1
8305 REPAIRS/REPLACEMENT AND CLEANING OF SEWAGE LI
Open Tender
Civil Works
Item Rate
270 days
GE (Central) Pune
As per tender
9 documents required · 9 mandatory
₹500
GE (Central) Pune
₹42,000
Yes
23 Jul 2022
28 Apr 2022
28 May 2022
28 Apr 2022
26 May 2022
12 May 2022
60 days
Amount
Scooping & taking out sludge, sullage and foreign materials from septic tank, soak wells of any description and depth including removing and refixing of accessories and appliances required for safe disposal of sludge, sullage and foreign materials either by carrying the same in covered van/trolley outside defence land and it should be disposed off at such place which is not determinated to public health Note :- Depth shall be measured for payment after bailing out water and the rate quoted inclusive of cost required for bailing out water
Cleaning of underground sewage line of any type and size up to and including 200mm dia including manhole upto 3m depth all in working and running condition involving removal of blockages of any kind in man holes or sewage lines by means of mechanical rodding with vibration /drilling concept ie trolley mounted motorized sewer cleaning machine including desluding descaling & dechoking of line wherever required, flushing the entire stretch with combined high pressure water jetting com suction (vaccume )type machine suitably fabricated on HCV having facilities of hydraulic application through high pressure thermoplastic, making the stretch clean, functional and removal /deposition of sludge inclusive of solids of any type & sludge water to a distance exceeding 1.5KM but not exc 5KM and covering the entire sludge and solids with local earth complete.
All as per item No 02 above but above 200 mm dia and upto &including 600mm dia sewage pipes including manholes upto the depth of 6.5m complete.
Cleaning of manholes n.exc. 1.5m deep including desludging and dewatering either by mechanical pump or manually and taking out solids/semi solids, well flushing with water, removing to a distance exc. 100m but n.exc. 250m and depositing in ditches including necessary excavation and earth work in soft/lose soil for making ditches over after the sludge are deposited spreading and levelling of excavated soil in the ditches over the sludge and removing surplus soil to a distance exc. 50m and sprinkling bleaching powder (including supply of bleaching powder) in a periphery of one metre around manhole complete all as directed.
All as per item No. 04 here-in-before but depth exc. 1.5 mtr and n.exc. 3.00 mtr
Cleaning and rodding the blocked sewage line of 150mm bore to any depth till the smooth flow of sewage line is restored including plugging of manholes temporarily as and when required and washing down complete sewage line with water including removing sludge and foreign materials from manholes in line and removing and refixing manhole covers and rodding complete all as directed by Engineer-in-Charge for following dia of pipes
All as per item No 6 above but 200mm bore
All as per item No 6 above but 300mm bore
Day to day maintenance and petty repair of sewage line (complaints pretaining to safaiwala) by attending daily complaints lodged by the users through IVRS/mobile/ sms/ or email and manual registratering of complaints at B/R complaint cell of AGE B&R II on all working days (except sunday, National holidays and closed holidays) by deploying safaiwala daily, complete all as specified and directed by Engr-in-charge. Note :- (a) Each complaint shall be completed within 24 hours. (b) If safaiwala not attended complaint within time frame mentioned above 50 % shall be deducted job completed by him. (c) The contractor will be responsible to maintain daily job completed by the safaiwala deputed by him in the sub work and obtained signature of I/C complaint cell/Engr-in-Charge daily at 1700 hours on all working days.
Demolition and breaking up RCC, SWG drain pipes 150mm bore set in cement mortar and removing debris from the site complete all as directed by Engr-in-Charge.
All as per item No 10 above but 200mm dia
All as per item No 10 above but 300mm dia
Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundations, manholes etc and getting out in in soft/loose soil.
Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundations, manholes etc and getting out in hard / dense soil.
All as per item No. 14 here in before but depth exceeding 1.5 mtr and upto 3 mtr and getting out in hard/dense soil.
All as per item 14 here in before but in soft/disintegrated roack.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in soil.
Removing the excavated surplus soils exceeding 50mtr but n.exc 250 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point
M&L RCC pipes class NP-2 with socketed ends laid and jointed complete with rubber ring joints of 150mm dia. Note :- Laying of sewage line in running sewage water & temporary diversion /plugged of existing sewage line & bailing of sewage water is the responsibility of contractor and the rate for the same is seems to be included in the contract
All as per item 19 above but 200mm dia.
All as per item 19 above but 300mm dia.
M&L for PCC 1:3:6 type C2 using 40mm graded agg as in bed to drain pipes including packing under and aunching against the sides of pipes after are laid and tested in for 150mm dia of pipe.
All as per item 22 above but 200mm dia of pipe
All as per item 22 above but 300mm dia of pipe
S&F in repairs PVC floor trap with steel grating including jointing with solvent cement of 75 mm dia complete all as spd and directed
S&F in repairs PVC gully traps, square 125/110mm size with grating including jointing to waste pipe in cement joint, dia of outlet 100mm complete all as specified and directed.
Demolition floor hearth or wall tiling including cement mortar bedding. ( but not backing ), removing from site of work complete.
M & L for 25 mm thick PCC 1:2:4 type B1 using 20 mm graded aggregate as in leveling course complete all as specified and directed.
M&L for coloured non skid ceramic tiles flooring 7 to 8 mm thick area of each tile exceeding 0.06 sqm and not exc 0.11 sqm (300x300mm) with joint free tiles set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick cement screed bed in CM 1:6 complete.
Cutting into existing manholes for connecting new drains of dia 150 mm making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, for the following size of pipe :-
All as per item No 30 above but 200 mm bore
All as per item No 30 above but 300 mm bore
Demolition of cement concrete in ground floors and paving not exc 15cm thick (below or above ground level) un-reinforced. Complete all as specified and directed.
Demolition of cement concrete reinforced of any description and in any position not otherwise specifically provided.
M&L for providing precast RCC (1:2:4) type B1 using 20 mm graded stone aggregate in Manhole covers set in CM 1:4
M&L for mild steel TMT bars upto 10mm dia cut to length, bent to shape required, bending and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
M&L for precast cement concrete block masonry exceeding 10cm in width witth solid blocks of PCC (1:5:8) gde D-5 and setting in CM 1:6 Note : Demolition of old PCC block walls will be measured and paid for under item No 33 above
M&L PCC (1:2:4) type B-1 using 20 mm stone graded aggregate as in cills, steps, bands, plinth courses, string courses, lacing courses, coping kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles etc complete.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc
Rendering 15mm thick in cement mortar 1:4 on brick/concrete surfaces finished even and smooth using extra cement with neeru finish complete
Demolition and breaking of drain pipes AC /CI/PVC set in cement mortar or adhensive all as directed of 75mm to 110 mm dia
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors/in earth of 110 mm dia.
S&F PVC (SWR) bends plain 110 mm bore
S&F PVC(SWR) bends plain 75mm bore
S&F PVC (SWR) bends with oval access door of 110 mm bore
S&F PVC (SWR) bends with oval access door of 75 mm bore
S&F PVC SWR Branch piece single (Single Y) equal or unequal 110mm dia with door access.
S&F PVC SWR Branch piece single (Single Y) equal or unequal 75 mm dia with door access.
S&F PVC (SWR) of 110mm dia junction single (single 'T') equal or unequal with door access.
S&F PVC (SWR) of 75 mm dia junction single (single 'T') equal or unequal with door access.
S&F PVC SWR Branch piece double (double 'Y') equal or unequal 110mm dia with door access.
S&F PVC SWR Branch piece double (double 'Y') equal or unequal 75mm dia with door access.
S&F for 110 mm dia PVC SWR vent cowl
S&F for 75 mm dia PVC SWR vent cowl.
S&F in repair stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete
M&L for 100mm plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed
M&L for rubber moulded glossy chequered cement concrete tiles 30cm x 30cm x 20mm thick, set, jointed and pointed in neat cement slurry with grey cement and no pigments in floors over and including 15mm thick screed bed in cement mortar 1:6 complete
M&L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in precast kerb stone including chamfers weathering set in cement mortar 1:4 and joints to match with CM1:3 complete all as specified and directed by engineer in charge
M/S - KRUPA ELECTRICALS
M/s.BAJRANG CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .