Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 23B ANIL KUMAR BANSAL 23B SADAR BAZAR 941 JHANSI UTTAR PRADESH 284001 UDYAM UP 39 0001184 | JHANSI | UTTAR PRADESH | 284001 | Accepted-Technical Substantially Responsive |
| 2 | Accepted-Technical | Accepted-Technical Substantially Responsive |
| 3 | Accepted-Technical MOHALLA M N 21 MURARI NAGAR FAIZABAD ROAD INDIRA NAGAR THANA GHAZIPUR LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | Accepted-Technical Substantially Responsive |
Tender Value
Refer Docs
EMD Value
₹91,000
Closing Date
5 Dec 2025, 12:00 pmClosed
SE AK Singh
Superintending Engineer E/M Circle, P.W.D. Kanpur
Electrical maintenance of Government Residential Building at District Jhansi
2025_CEEMP_1094494_1
1579/03C-EMC/25-26, Dated-15-11-2025
Open Tender
Electrical Works
90 days
Jhansi
Please refer Tender documents.
4 documents required · 4 mandatory
₹766
Electrical/Mechanical Division PWD Jhansi
₹91,000
Jhansi
8 Dec 2025
28 Nov 2025
5 Dec 2025
28 Nov 2025
5 Dec 2025
28 Nov 2025
1 Dec 2025
S/F 5/6 Amp. Piano type switch in existing box Anchor/Havells/Equivalent Make.
S/F 3 pin 15/16 Amp. Piano type switch in existing box Anchor/Havells/Equivalent Make.
S/F 3 pin 5/6 Amp. Piano type socket in existing box Anchor/Havells/Equivalent Make.
S/F 6 pin 15/16 Amp. Piano type socket in existing box Anchor/Havells/Equivalent Make.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
S/F of 40 Amp. Double pole 240 V Isolator in existing DB Anchor/ Havells/Equivalent Make.
S/F of 63 Amp. Double pole 240 V Isolator in existing DB Anchor/ Havells/Equivalent Make.
Suppling and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required i- (1 X 1.5 sq. mm )
Suppling and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required ii- (2 X 1.5 sq. mm )
Suppling and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required iii- (3 X 1.5 sq. mm )
Suppling and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required i- (2 X 2.5 sq. mm )
Suppling and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required ii- (3 X 2.5 sq. mm )
Suppling and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required iii- (2 X 4.0 sq. mm )
Suppling and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required iv- (2 X 6.0 sq. mm )
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) i- 6 way SPNDB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) ii- 8 way SPNDB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) iii- 12 way SPNDB
Supply of 3 mm thick phenolic laminated sheet (per sq.cm) 210 mm x 260 mm = 546.00 sq. cm
Supply of 3 mm thick phenolic laminated sheet (per sq.cm) 260 mm x 310 mm = 806.00 sq. cm
Supply of 1.5 Sq. mm ISI marked FRLS PVC Insulated single core copper conductor cable. /per mtr.
Supply of 2.5 Sq. mm ISI marked FRLS PVC Insulated single core copper conductor cable. /per mtr.
Supply of 4.0 Sq. mm ISI marked FRLS PVC Insulated single core copper conductor cable. /per mtr.
Supply of 6.0 Sq. mm ISI marked FRLS PVC Insulated single core copper conductor cable. /per mtr.
Supply and fixing of switch size fan regulator & complete Havells or Eq.
Supply and fixing of socket size fan regulator & complete Havells or Eq.
Supply and fixing of 40 Amp. DP MCB (10 KA) C-Series Discount 20% Havells or Eq.
Supply and fixing of 63 Amp. DP MCB (10 KA) C-Series Discount 20% Havells or Eq.
Supply and fixing of 40 Amp. FP MCB (10 KA) C-Series Discount 20% Havells or Eq.
Supply and fixing of 63 Amp. FP MCB (10 KA) C-Series Discount 20% Havells or Eq.
Supply and fixing of 100 Amp. FP MCB (10 KA) C-Series Discount 20% Havells or Eq.
S/R of 16A/240V kit kat (Havells or Equivalent)
S/R of 32A/240V kit kat (Havells or Equivalent)
S/R of 63A/415V kit kat (Havells or Equivalent)
S/R of 100A/415V kit kat (Havells or Equivalent)
S/R of 2.5 mfd Condensor (Havells or Equivalent)
S/R of 3.15 mfd Condensor (Havells or Equivalent)
Rewinding of 48" old model A.C. Celling fan including cost of super enemal copper conductor, varnishing complete with less cost of old material.
Rewinding of 56" old model A.C. Celling fan including cost of super enemal copper conductor, varnishing complete with less cost of old material.
Rewinding of 48" New model A.C. Celling fan including cost of super enemal copper conductor, varnishing complete with less cost of old material.
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
Tendernotice_2.pdf
PDF • 8.21 MB
Tendernotice_3.pdf
PDF • 0.97 MB
Tendernotice_4.pdf
PDF • 2.77 MB
BOQ_2012663.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid