| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹20.7 LAccepted-AOC THE LORDS CAMPUS HOUSE NO 21 22 E 8 EXTENSION BAWADIYA KALAN BHOPAL M P 462039 | BHOPAL | MADHYA PRADESH | 462039 | L 1 | Accepted-AOC TENDERS ACCEPTED | |
| 2 | L 2₹22.3 L+₹1.6 L (7.88%)Rejected-Finance | L 2 | Rejected-Finance REJECT | |
| 3 | L 3₹23.1 L+₹2.5 L (11.9%)Rejected-Finance | L 3 | Rejected-Finance REJECT | |
| 4 | L 4₹25.4 L+₹4.7 L (22.8%)Rejected-Finance | L 4 | Rejected-Finance REJECT |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
16 Mar 2021, 5:00 pmClosed
Project Engineer Gwalior Division No 02
Project Engineer Gwalior Division No 02
EXTERNAL ELECTRIFICATION WORK FOR 8 24 48 QTRS. DRP LINE MORENA Phase II
2021_MPPHC_132339_1
20/2020-21
Open Tender
Electrical Works
Item Rate
90 days
Project Engineer Gwalior Division No 02
AS PER NIT
6 documents required · 6 mandatory
₹5,000
₹50,000
4 Aug 2023
3 Mar 2021
20 Mar 2021
3 Mar 2021
16 Mar 2021
3 Mar 2021
Amount
Supplying and erection of HT/LT overhead line single length supporting complete with aligning and keeping it in truly vertical position including digging pit of required size filling with 1:3:6 cement concrete of 0.60 meter. dia of required length around the pole including muffing of 0.50 meter. from ground level as perspecifications with 20 cm. thick base foundation providing and busying 15 mm dia G.I. pipe from bottom to 1.5 meters above ground level on pole refilling the pit including painting of pole with bitumen paint in bottom and one coat of red oxide and two coats of aluminum paint etc. complete as per specification. The depth offoundation shall be 1/6th of the length of pole"H"Beam 152x152 mm or 150x150 mm 37.1 kg/meter weight (A) 13.00meter long
Supplying and erection of HT/LT overhead line single length supporting complete with aligning and keeping it in truly vertical position including digging pit of required size filling with 1:3:6 cement concrete of 0.60 meter. dia of required length around the pole including muffing of 0.50 meter. from ground level as perspecifications with 20 cm. thick base foundation providing and busying 15 mm dia G.I. pipe from bottom to 1.5 meters above ground level on pole refilling the pit including painting of pole with bitumen paint in bottom and one coat of red oxide and two coats of aluminum paint etc. complete as per specification. The depth offoundation shall be 1/6th of the length of pole"H"Beam 152x152 mm or 150x150 mm 37.1 kg/meter weight (A) 11.00meter long
Supplying and erection of steel tubular pole swaged type as per IS:2713 1980 Complete with baseplate and top Canopy (with G.I. pipe bracket as required), supports complete with digging and keeping it in truly vertical position i/c digging pit of required size filling with 1:3:6 cement concrete of 0.60 meter dia. of required length around the pole i/c muffing of 0.45meter from ground level as per specification with 20cm.thick base foundation providing and busying 15mm.dia.G.I.pipe from bottom to 1.5meter above ground level on pole, refilling the pit i/c. painting of pole with bitumen paint in bottom and one coat of red oxide and two coat of aluminum paints etc. complete as per specification. The depth of foundation shall be1/6th of the length of pole.(A) 410 SP-29 - 9.00 meter long.
Supplying and erection of HT/LT overhead line single length supporting complete with aligning and keeping it in truly vertical position including digging pit of required size filling with 1:3:6 cement concrete of 0.60 meter. dia of required length around the pole including muffing of 0.50 meter. from ground level as perspecifications with 20 cm. thick base foundation providing and busying 15 mm dia G.I. pipe from bottom to 1.5 meters above ground level on pole refilling the pit including painting of pole with bitumen paint in bottom and one coat of red oxide and two coats of aluminum paint etc. complete as per specification. The depth offoundation shall be 1/6th of the length of pole"H"Beam 152x152 mm or 150x150 mm 37.1 kg/meter weight (A) 09.00meter long
Providing and fixing ear thing arrangement for H.T./L.T. poles with G.I. wire of 115 turn of 50mm dia. and 2.5Mtr. of Lead of 4.0 MM G.I Wire connection with bracket/ cross arm/ pole with 4mm dia. G.I. lead through 20 mm dia. G.!. Protection pipe of length from bottom of pole to 2mtr. above ground level, packing of charcoal powder&salt as per specification including excavation of pit in all typeofsoil /rock etc.complete.(including Bentonite Power)
Supplying and errection of stay set completed with stay rod, anchor plate, thimble, stay clamp, turn buckle etc. with stay wire strain insulator nut bolts as per specifications including concreting in required size and excavation in all type of soil! Rocks and also foundations in cement concrete 1:3:6 complete of required size and other necessary materials complete as per specification. (A) Stay rod 20mm with 7/3.15MM. stay wire
Supplying and errection of stay set completed with stay rod, anchor plate, thimble, stay clamp, turn buckle etc. with stay wire strain insulator nut bolts as per specifications including concreting in required size and excavation in all type of soil! Rocks and also foundations in cement concrete 1:3:6 complete of required size and other necessary materials complete as per specification.(A)Stay rod 16mm with 7/4.00MM. 7/8 swg mm stay wire 1.8 m long.
Supplying and fixing of Angle/ channel/flat iron, V cross Arms reinforcement of RSJ jolt/ flat iron fittings for overhead lines and poles such as cross arms/ bracket/ clamps/ stiffness for poles etc. all required steel work including' cutting to size making proper shapes drilling scan welding etc. including nuts & bolts plan & spring wisher and other necessary material including one coat of red oxide and two coat of aluminum paint etc. as required.
Supplying and fixing Polymer type 11 K.V. pin insulator with G.I. pin of approved make on existing pole or bracket with necessary materials and hardware complete as required.
Supplying and fixing polymer type 11 K.V. disc (strain) insulator of approved make on existing pole or bracket with necessary materials and hardware complete as required.
Supplying and drawing AAAC conductor of approved make with stringing making off complete with binding at existing insulator, jointing , jump ring, billing off connecting, making 'D' loops connections etc. complete and clearing of obstacles (if any) as specified &directed. (A)AAAC Conductor 0.75sq inch (80 sqmm) aluminumorEquivalent RACOON
Supplying and drawing AAAC conductor of approved make with stringing making off complete with binding at existing insulator, jointing , jump ring, billing off connecting, making 'D' loops connections etc. complete and clearing of obstacles (if any) as specified &directed. (A)AAAC Conductor 0.55sq inch (55 sqmm) aluminumorEquivalent
Supplying and fixing of danger/ caution Board as per specification with necessary materials complete for H.T.lines and other equipments as required.(Danger Board Enamelled11KV)
Supplying and fixing 12x16 gauge barbed wire antidumping device (900 mm and3.5kg wire on pole) around the existing H.T. pole and sub station poles for safety measures as per IE rulesincluding allstaples & all other necessary materials complete as per mpseb specification.
Supplying, installing, testing and commissioning of 11/0.4 KV 3 Phase 50 cycle oil immersed, naturally cooled, outdoor type transformer connected delta on H.T. side and star on L.T. side, dehydrating silica gel breather on eye level, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve with plug, temperature not exceeding 50ºC on load, oil filling hole with plug, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable box on LV side, first filling of oil upto desired level and transformer installing on existing structure with all required materials arrangement as required ISI marked & as per IS specification, hand operated off load tap changer switch above 100 KVA, oil conservator with drain valve, plug 63 KVA and above.Energy efficiency level -2 Aluminium wound 200 KVA
Supplying, installing, testing and commissioning of 11/0.4 KV 3 Phase 50 cycle oil immersed, naturally cooled, outdoor type transformer connected delta on H.T. side and star on L.T. side, dehydrating silica gel breather on eye level, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve with plug, temperature not exceeding 50ºC on load, oil filling hole with plug, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable box on LV side, first filling of oil upto desired level and transformer installing on existing structure with all required materials arrangement as required ISI marked & as per IS specification, hand operated off load tap changer switch above 100 KVA, oil conservator with drain valve, plug 63 KVA and above.Energy efficiency level -2 Aluminium wound 100 KVA
Providing and fixing outdoor type pole mounting weather, dust and vermin proof L.T. distribution box made of 14/16 gauge, M.S. sheet with clamping arrangements, lockable hinged door duly painted on all sides with red oxide antirust and corrosion treatment two coats of synthetic enamel paints of approved make and shade, consisting of following fittings. L.T. Distribution box suitable for 200.KVA.transformer (with TPN MCCB315 AMP Rating ) with required ratig BUS BAR incoming side and PF HRC units on outgoing side 09 NOo. As required As per specification complet .
Providing and fixing outdoor type pole mounting weather, dust and vermin proof L.T. distribution box made of 14/16 gauge, M.S. sheet with clamping arrangements, lockable hinged door duly painted on all sides with red oxide antirust and corrosion treatment two coats of synthetic enamel paints of approved make and shade, consisting of following fittings. L.T. Distribution box suitable for 100.KVA.transformer (with TPN MCCB160 AMP Rating ) with required ratig BUS BAR incoming side and PF HRC units on outgoing side 09 NOo. As required As per specification complet .
Commissioning of D P structure over existing support with panting in an approved manner consisting of following :-(A) D. C. cross arm with clamp, nuts & bolts (100 x 50 mm only ) - 1 set (B) 11 KV D. O. fuse unit, lightings arrangement and AB swich mounting channel with nuts and bolts (75 x 40 mm channel) of require - 1 set (C) 11 KV Polymer AB swich 400 amp as required ( set of 3 Nos.) - 1 set (D) Transformer mounting cross arm /channels with clamps nuts and bolts (100 x 50 mm channel ) - 1set (E) 11KV Polymer Do fuse unit ( set of 3 no.) - 1 set (F)Transformer clamping set(50x50x6mm angle)with nuts &bolts etc.complete - 1 set (G)Transformerbeltingset(50x50x6mm angle) with nuts and bolts etc. complete -1 set (H) 11 kv polymer lightning arrestor(9kvgapless type(5kA)forDTR)(setof3No.)- 1 set (I) supplying , fixing, testing and connecting of complete earting set of 7 No.as per MPMKVVC.Ltd.circular No DSCOM/EZ/WS/1516/DT 17-03-2008 and approved drawing for transformer sub - station including all materials GI Strips,or wires,Charcoal power salt excavation of pits in all types of soils/rocks etc. as required complete .(1set of 5 Nos.) & ( 1 set of 2 Nos.) Chem rod earthing including electrode,chemical, (consisting galvanised mildsteelpipeof size 2000 mm x 50 mm outer diameteror higher size as per site conditions , filledwith a highly conductive material &a GIstrip minimum 16mmx3mm covering totalof pipe,forming theelectrode)forobtainingearth resistance less than 1ohms (J) Distribution panel mounting channel and clamp with nuts & bolts etc. (75 x 40 mm channel ) -1 set (K) Supplying , fixing, testing and Commissioning of DTR Meter( LT trivector energy meter,DLMS compliant category-A(for substation/feeder metring ), 3 phase 4 wire , 440 volts , 5 amp, accuracy class 0.5 S with GSM ( GPRS competeble) modem with box LT. 3 phase 4 wire 3X240 volts I 3 A. LTCT operated 3 phase 4 wire 3x63, 5 volts , LB = 5 amps lmax 10 amp trivector meter class of accuracy 0.5s DLMS complaint category a meter along with GSM ( GPRS compactable ) modems with box i/c all accessories and formalities as per MPMKVVCL as required. or 3P 4w - 5A LTCT class 5s DLMS compliant type c. rs - 232. Port box MRI LTCT 100/5A i/c meter box with TTB etc as required.(as per MPMKVVCL ITEM CODE NO-M-0302055)(L) SF & T and HT tape for covering LT bushing i/c windings and blower hitting complete minimum 30 meter or as required. D.P. Structure Complete as above (A to L)
Supplying ,laying ,testing, and commissioning of P V C insulated PVC heavy duty power cable confirming to lS 15541964,1100 volt grade cable Of approved make in trench ,G I pipe Air (laying on pole) trench, i/c cost of excavation in any type of soil/rock etc. including connection through lugs by cramping method glands etc as required as per specification.(A) Supplying laying testing&commissioning.UnArmoured single coreXLPE insulated alu. conductorcable.UnArmoured singlecoreXLPE insulated alu.conductor cable. 150sq mm.
Supplying ,laying ,testing, and commissioning of P V C insulated PVC heavy duty power cable confirming to lS 15541964,1100 volt grade cable Of approved make in trench ,G I pipe Air (laying on pole) trench, i/c cost of excavation in any type of soil/rock etc. including connection through lugs by cramping method glands etc as required as per specification.(A) Supplying laying testing&commissioning.UnArmoured single core XLPE insulated aluminum conductorcable.UnArmoured singlecoreXLPE insulated aluminum conductorcable.300sq mm.
Supplying ,laying ,testing, and commissioning of P V C insulated PVC heavy duty power cable confirming to lS 15541964,1100 volt grade cable Of approved make in trench ,G I pipe Air (laying on pole) trench, i/c cost of excavation in any type of soil/rock etc. including connection through lugs by cramping method glands etc as required as per specification.(A)Supplying laying testing and commissioning.UnArmoured singlecoreXLPE insulated aluminumconductorcable.XLPEinsulatedaluminumconductorcable.70sqmm.
Supplying ,laying ,testing, and commissioning of P V C insulated PVC heavy duty power cable confirming to lS 15541964,1100 volt grade cable Of approved make in trench ,G I pipe Air (laying on pole) trench, i/c cost of excavation in any type of soil/rock etc. including connection through lugs by cramping method glands etc as required as per specification.(B)Armoured3½core XLPE insulated aluminum conductor cable. (b)70sq mm.
Supplying ,laying ,testing, and commissioning of P V C insulated PVC heavy duty power cable confirming to lS 15541964,1100 volt grade cable Of approved make in trench ,G I pipe Air (laying on pole) trench, i/c cost of excavation in any type of soil/rock etc. including connectionthrough lugsby cramping method glands etc as required as per specification.(B)Armoured4coreXLPEinsulatedalu.conductorcable.16sqmm.(Forstreet light)
Supplying ,laying ,testing, and commissioning of P V C insulated PVC heavy duty power cable confirming to lS 15541964,1100 volt grade cable Of approved make in trench ,G I pipe Air (laying on pole) trench, i/c cost of excavation in any type of soil/rock etc. including connection through lugs by cramping method glands etc as required as per specification.(B) Armoured 2 core XLPE insulated aluminum conductor cable.(c) 2.5 sqmm 2 core armourad cable For street light connection
Supplying fixing testing GI Wire 8 SWG for gardings.(4 mm .dia.)
Supplying and installing Double wall corrugated pipes (DWC) of HDPE ( IS 14930 Part II -marked ) for cable laid under ground with necessary material and at required depth upto 90cm. below road/ground surface, including excavation, back filling with excavated material, ramming and making the surface good. 110 mm out side dia.
Supplying and installing Double wall corrugated pipes (DWC) of HDPE ( IS 14930 Part II -marked ) for cable laid under ground with necessary material and at required depth upto 90cm. below road/ground surface, including excavation, back filling with excavated material, ramming and making the surface good. 50 mm out side dia.
Providing and fixing chain link fencing sourriding existing DTR S/S finical (Total 37 running meter maximum) of 6’ height with chain ling fencing on MS Angle (50X50X6) mm support 7 nos. 7’ height with following feature. (A) Upper & lower frame of fencing will be of MS angle (25X25X4) mm size.(B)MSstripof(25X5) mm flat shall be used fro cross bracing of fencing (C) Double Gate (2nos. 2.5’X5’) of MSangle(50X50X6)mm.bracingof 25X5mmflatwith mesh & locking arrangement.Complete as above( A to C) – one job. wire mesh fancing mesh type (1"X1")
SUPPLY FIXING,TESTING 11 kv ab switch polymer type 600 amp with complete fitting
Supplying Fixing And Testing MS or Fiber Kit kat Box with 10 Amp SP 25 KA MCB Complete.for street light poleComplete As Required As per As MPSEB per norms and specification Req.
Supplying and installation, of totally enclosed dust, vermin and weather proof outdoor type cubical feeder pillar of required size, fabricated with 14 SWG CRCA sheet, free standing type with MS angle iron frame of size 50x50x5mm, 4 Nos. legs each of 1.2 meter long of 50x50x5mm angle iron etc., suitable sheet steel sloping hut type canopy on top of feeder pillar with 50mm projection on all sides of feeder pillar for protection against rain/weather etc. The feeder pillar shall be painted with 100 micron powder coating on all sides, door etc. after anti rust and anti corrosive treatment, vertical/ horizontal bus bar of required size and length, fixed on SMC sheet with insulators, GI hardware, neoprene gasket, inter connection with copper wires/cables of bus bar, switch gear, MCCB 100 Amp. 14 No SPN MCB 32 AMP., Cutout or wherever required with suitable lugs of required capacity and size, providing earthing terminal bus bar of size 25x5mm with GI nut, bolts at outside of the panel with earth continuity GI strip 25x5 mm inside the panel with holes, providing engraved name plate with rating of incoming and outgoing feeder and house No., eye bolts, suitable cutouts with wire mesh jali for ventilation, detachable gland plates. The feeder pillar to have hinged type double door on front side with locking arrangement, including Godrej lock, separate chamber for incoming and outgoing MCCB/MCB etc. complete including supplying, fixing, connecting, testing and commissioning of the following materials and accessories:-LT FEEDER PILLER 6 WAY AND OUT DOOR TYPE CUBICAL FEEDER PILLER
Providing and fixing including Testing of LED fixture on street light pole, the fixture should be IP- 65, PF be 0.95 with 85% Power effecency at least of life span of (approxy)working 50,000 Hrs Housing be of Al. Dye cost including connection etc cable reqd. GI pipe braket nute & bolts etc. (Make Bajaj, Crompton, Havells, Surya, Philips, ) (A) 90 watt LED
JOINTING SLEEVES SUITABLE FOR DOG 100 SQ.MM AAAC CONDUCTOR
HIGH PRECESION THREAD THROUGH COMPOSITE METER UPTO 100 KVA
Sheet metel meter Box sutable for HT static Travector meter with TTB As per MPEB Norms
Copper Control Cable 8 Core 2.5 Sq mm Un ARMOUD As per MPEB Norms
Copper Control Cable 4 Core 2.5 Sq mm Un ARMOUD As per MPEB Norms
Marshelling Box with 10 No. Conector As per MPEB Norms
11 KV CT OUT DOOR DRY TYPE 200-100/5 AMP.As per MPEB Norms
11 KV ISOLATOR 800 AMP Turn and TWIST TYPE As per MPEB Norms
BI METALIC CLAMP DISTRIBUTION TRANSFORMER BUSHING As per MPEB Norms
SITC OF 11 KV VCB OUTDOOR PORCELIN CLAD TYPE WITH COMPLETE STRUCTURE AND ACCESSORIES As per MPEB Norms
11 KV CONTROL AND RELAY PANEL STETIC RELAY FOR FEEDER PROTECTION As per MPEB Norms
BHUPENDRA SINGH TOMAR
JITENDRA SHARMA
Om Shiv Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .