Loading…
Loading…
Tender Value
₹61.0 L
EMD Value
₹1.2 L
Closing Date
27 Aug 2026, 3:00 pm2d left
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
16 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Note: In case, date of tender inviting is on or after date of statutory deadline for audit of balance sheet of previous FY (i.e. 30th Sept or as further extended for this FY), audited balance sheet of 4th previous year shall not be considered unless concerned CA certifies that balance sheet is not audited yet as on date of invitation of this tender.
The contractor should have valid Electrical Contractor License issued by Govt. and submit along with tender document. If valid Electrical Contractor License is not submitted along with tender document, then offer will be summarily rejected.
16 conditions · 3 needing a document upload
The tenderer shall submit all relevant documents as detailed in para 14 & 18.10 of Tender Form (Second Sheet) of Part I of GCC work-2022.
The tenderer shall submit copy regarding status of firm i.e. sole proprietorship, partnership, Company, Society/Trust etc. and also submit a power of attorney and other relevant documents as detailed in Para no. 15 of Tender Form (Second Sheet) of Part- I of attached GCC-2022.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. Following documents shall be submitted by the tenderer:
a) Sole Proprietorship Firm: (i) All documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(b) HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC- 2022.
(c) Partnership Firm: (i) A notarized copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. (ii) A notarized or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract. (iv) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(e) Company registered under Companies Act 2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(f) LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm / LLP or JV in which they were / are partners / members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(g) Registered Society & Registered Trust: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he / they be partner(s) of the firm or any other person, specifically authorizing him / them to sign the tender, submit the tender and further to deal with the Tender / Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association / Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he / they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should quote only the above/below percentage on estimated value, in the space provided at web portal for the purpose & nowhere else. Financial & Technical conditions quoted at any place other than prescribed space shall not be entertained while evaluating the offer.
Tenderer are required to go through the documents attached along with the tender and submit their bids accordingly.
Electrical work in c/w Raising of Medium Level PF No. 1 at Gajner & Nal and PF No. 1 & 2 at Diyatra Road and PF No. 1 at Sahuwala Halt from Rail Level to High Level stations over Bikaner Division along with extension to 480 Mtrs.
05-EL-BKN-E-Tender-26-27R~NWR
05-EL-BKN-E-Tender-26-27R
Open
Works - General
8 Months
Bikaner, Rajasthan
₹0
₹1.2 L
5 Aug 2026
5 Aug 2026
13 Aug 2026
130 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 60,99,273 | ||
| — | 100.00 | — | — | ||
| Supply of material and wiring of LP/TP/FP/Ex.Fan point with 1.5sqmm PVC single core multi-stranded copper wire insulated concealed in stone/brick masonry wall in 19/20 mm PVC conduit with 1.5sqmm PVC wire insulated copper for earth wire 1-way/2-way switch 5/6A as required and good quality ceiling rose including connection. This item includes modular switch, ceiling rose, PVC conduit and required chase as per site. | — | — | — | 41,100 | |
| — | 30.00 | — | — | ||
| Supply and fixing 5/6A plug, modular 3/5-pin 230V including modular switch and with modular board and connection as per spec. | — | — | — | 7,980 | |
| — | 10.00 | — | — | ||
| Supply and fixing 15/16A plug, modular 5/6-pin 230V including modular switch and with modular board and connection as per spec. | — | — | — | 2,990 | |
| — | 10.00 | — | — | ||
| Supply and fixing 2 module modular switch board plate for fixing of modular switches -plug with sheet metal box of good quality concealed fixing of MS / PVC as per site requirement and specification. | — | — | — | 1,250 | |
| — | 5.00 | — | — | ||
| Supply and fixing 4 module modular switch board plate for fixing of modular switches -plug with sheet metal box of good quality concealed fixing of MS / PVC as per site requirement and specification. | — | — | — | 930 | |
| — | 2.00 | — | — | ||
| Supply and fixing 6 module modular switch board plate for fixing of modular switches -plug with sheet metal box of good quality concealed fixing of MS / PVC as per site requirement and specification. | — | — | — | 462 | |
| — | 2.00 | — | — | ||
| Supply and fixing 8 module modular switch board plate for fixing of modular switches -plug with sheet metal box of good quality concealed fixing of MS / PVC as per site requirement and specification. | — | — | — | 616 | |
| — | 10.00 | — | — | ||
| Supply and fixing 12 module modular switch board plate for fixing of modular switches -plug with sheet metal box of good quality concealed fixing of MS / PVC as per site requirement and specification. | — | — | — | 3,410 | |
| — | 200.00 | — | — | ||
| Wiring of sub-main with 2x2.5 sqmm PVC insulated, single core, multi-stranded copper wire in PVC conduit concealed and 2.5sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec. This item includes PVC conduit (25 mm) and chase as per requirement. | — | — | — | 15,000 | |
| — | 200.00 | — | — | ||
| Wiring of sub-main with 2x4 sqmm PVC insulated, single core, multi-stranded copper wire in PVC conduit concealed and 4.0 sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec. This item includes PVC conduit (25 mm) and chase as per requirement. | — | — | — | 25,600 | |
| — | 200.00 | — | — | ||
| Wiring of sub-main with 2x6 sqmm PVC insulated, single core, multi-stranded copper wire in PVC conduit concealed and 6.0 sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec. This item includes PVC conduit (25 mm) and chase as per requirement. | — | — | — | 27,800 | |
| — | 150.00 | — | — | ||
| Supply, laying, connection and commissioning of sub-main 2x10 Sqmm with PVC insulated single core copper conductor cable and same size PVC insulated copper conductor for earthing wire in ISI marked PVC conduit in recessed / on surface as per site requirement. This item includes PVC conduit (25 mm) and chase as per requirement. | — | — | — | 41,250 | |
| — | 400.00 | — | — | ||
| Supply & wiring of light / fan point in covered shed with 1.5sq.mm multistrand copper, PVC insulated, single core wire in PVC 19/20 mm ISI PVC conduit pipe mounted on structure / shed with ceiling rose 5 Amp. mounted on wooden block / PVC junction box as per site requirement. | — | — | — | 74,800 | |
| — | 2000.00 | — | — | ||
| Supplying and drawing 4.0 sq. mm PVC insulated multistrand copper conductor cable as submain and 1.5 sq. mm PVC insulated multistrand earth copper cable voltage grade 1.1 kV as earthing wire conforming to IS: 694-1990 in existing conduit / casing capping. Wire should be of reputed make and as per tech. spec. | — | — | — | 84,000 | |
| — | 350.00 | — | — | ||
| Fixing & commissioning of LED Tube Light four feet complete with all accessories. | — | — | — | 11,550 | |
| — | 30.00 | — | — | ||
| Fixing & commissioning of ceiling fan with nut bolt, rod, regulator, etc. ensuring all safety aspects. Contractor is responsible for falling of fan within a period of 12 month. (Regulator will be supplied by Railway) | — | — | — | 780 | |
| — | 50.00 | — | — | ||
| SITC of 4 meter length B Class 50 mm dia GI pipe earth station with digging pit & refilling with charcoal & salt. (As per specification) | — | — | — | 68,250 | |
| — | 50.00 | — | — | ||
| Construction & supply of earth pit CC furnished chamber 300 x 300 x 250 mm, 50 mm thick with CI/RCC earth pit cover 300 x 300 x 25 mm with lifting hooked in center. | — | — | — | 29,450 | |
| — | 250.00 | — | — | ||
| Supply, laying and fixing of 25 x 5 mm GI earth strip at 0.5 metre below ground level or on walls/poles / along pipes etc, including connection / termination with GI nut, bolt, washer etc as required (jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50 mm). Note:- Suitable GI saddles with screws shall be provided to secure earth strips run on walls / floors etc. | — | — | — | 37,250 | |
| — | 200.00 | — | — | ||
| Supply, installation, testing and commissioning of 50 mm height and 200 mm width GI hot dip perforated cable tray with cover and all required mounting accessories as per site requirement & technical specification. | — | — | — | 1,00,200 | |
| — | 15.00 | — | — | ||
| Supply and fixing of junction box size 390x305x170mm comprising of SMP/FRP material with rubber gasket, padlock arrangement, zinc passivated earth bolt, etc. similar to Sintex model no. GSJB 3525 or similar with 4 no. aluminium busbar cap 200 Amp., suitable for 415 volt supply requirement. The box shall be fixed robustly with clamps at pole / wall as per requirement. All the material should be of good quality. | — | — | — | 32,070 | |
| — | 5.00 | — | — | ||
| Supply and fixing of junction box size 500X450X100mm comprising of sheet steel 2mm thick, 60 micron powder coating / two coats of primer and finished by enamel paint - grey shade, with gland plates, neoprene EDPM/rubber gasket, padlock arrangement, zinc passivated earth bolt, canopy etc. with 4 no. aluminium busbar cap 200 Amp., suitable for 415 volt supply requirement. The box shall be robustly fixed with clamps at pole / wall as per requirement. | — | — | — | 17,140 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of single phase, 230 volt 50 Hz operating ventilation fan of 300 mm. sweep with louver shutters. Fan should be of reputed make and as per tech. spec. | — | — | — | 22,540 | |
| — | 6000.00 | — | — | ||
| Supply of 4 x 16 sq. mm, 1.1KV grade, LT XLPE insulated PVC outer sheathed aluminium conductor armoured cable confirming IS: 7098 (Part-1) and as per tech spec. Reputed make like KEI, Polycab, Finolex, Havells or similar. (RITES Inspection) | — | — | — | 8,52,000 | |
| — | 2000.00 | — | — | ||
| Supply of 4 x 70 sq. mm, 1.1KV grade, LT XLPE insulated PVC outer sheathed aluminium conductor armoured cable confirming IS: 7098 (Part-1) and as per tech spec. Reputed make like KEI, Polycab, Finolex, Havells or similar. (RITES Inspection) | — | — | — | 7,16,000 | |
| — | 8000.00 | — | — | ||
| — | — | — | 1,68,000 | ||
| — | : - Laying, air with or during times the lug. The shall be meters. restored | testing, commissioning tray etc. with complete fixture (02 nos. per mtrs).Cables installation. The minimum overall diameter of the cable along the wall should provided to supporting the Breaking of wall to make to original levels to the | LT of to a PVC/XLPE size of two cable | ||
| — | 7800.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 50mm dia, wall thickness 3mm, PN- 6, PE-80 as per requirement. (RITES Inspection) | — | — | — | 5,14,800 | |
| — | 7800.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 50mm dia, wall thickness 3 mm, under the road. The work involves laying of HDPE pipe along with transportation. | — | — | — | 62,400 | |
| — | 300.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 110 mm dia, wall thickness as per IS, PN-6, PE-80 as per requirement. | — | — | — | 1,02,600 | |
| — | 7800.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec. (trench work may be on kachha / pakka land and all type of soil as per site requirement and without protective layer of brick) Surface of trench shall be made good in all respect and satisfaction of site engineer. | — | — | — | 3,12,000 | |
| — | 300.00 | — | — | ||
| Cutting of cement concrete floors (PCC / RCC), any type / depth as required for laying of UG cables in trenches and disposing off the excavated material as directed including refilling the trenches in layers and consolidating complete all as specified and directed. Note:-Providing barricading and danger lighting around the excavated areas safety precaution is a mandatory requirement and cost of this provision, wherever required, is deemed to be included in the quoted rate of this item. | — | — | — | 3,34,800 | |
| — | 60.00 | — | — | ||
| Supply, laying and fixing of GI pipe medium "B" class (Blue) confirming to IS 1239 part-I for passing incoming and outgoing cable from ground through it size 50 mm dia. Pipe should be of reputed make. | — | — | — | 11,820 | |
| — | 10.00 | — | — | ||
| Supply of Phenolic top mobile charging wooden board size 6''x15'' fitted with 4 nos. switch & 4 nos. socket of 6 Amps with internal wiring of 1.5 sq. mm multistrand copper wire with base plate of both side particle board for mobile with hanging clip as per requirement. | — | — | — | 3,980 | |
| — | 150.00 | — | — | ||
| Supply & provision of cable marker. The cable marker shall be made of MS Sheet 1.5mm thick size 150X100mm welded with 12mm dia MS rod 85 cm long. The lower end of rod should be turned in hooks shape and attached with the cable at the time of laying. | — | — | — | 24,300 | |
| — | 300.00 | — | — | ||
| Drilling of horizontal bore below Track/Road by pushing method (trenchless technology) for laying of RCC/HDPE/DWC pipe of various sizes up to 200 mm dia. in presence of Railway representative taking all necessary safety precautions related track and movement of trains. Horizontal boring will be done at minimum 1.5 Mtr. Below from ground level at railway track portion. | — | — | — | 3,45,900 | |
| — | 140.00 | — | — | ||
| Supply & erection of 5 Mtr high with double arm (500mm to 1500mm) model no. BOP-5030 of Bajaj or similar, pole shaft material S355J0 or equivalent as per IS, hot dip galvanized steel octagonal pole with galvanized base plate of 200x200x12 mm, junction box with 6 Amp. MCB and stud terminals (for mounting inside the base compartment of pole), foundation bolt size 4x16mm dia. 600 mm in length including excavation and making foundation as per spec. and drawing. It shall be galvanized internally and externally by single dipping method. The pole and foundation shall be made as per attached drawing / specification. (RITES Inspection) | — | — | — | 12,64,200 | |
| — | 30.00 | — | — | ||
| Supplying, fixing and commissioning of street light fitting accessories e.g. GI pipe of suitable bore as per fitting, clamps, nuts, bolts, cable, etc. as per instruction of site engineer. | — | — | — | 4,410 | |
| — | 310.00 | — | — | ||
| Fixing of LED Street light / HM flood light outdoor type with all its accessories as per site requirement and Engineer in charge of railway. | — | — | — | 37,820 | |
| — | 2100.00 | — | — | ||
| Supplying and drawing FR PVC insulated & unsheathed flexible 3 Core X 1.5sqmm PVC Unarmoured copper cable ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. | — | — | — | 1,07,100 | |
| — | 60.00 | — | — | ||
| Removal of existing Rail/swage poles with overhead wire and all accessories from station area. Rail are to be cut 0.5m below the ground level & making the ground level good by suitable cement concrete and transportation of rail pole and all accessories with fitting etc. complete from site to place located at that station by concern SSE/Elect. | — | — | — | 33,540 | |
| — | 5.00 | — | — | ||
| Removal of existing octagonal pole from p/f surface area & making the surface good by suitable cement concrete and transportation of pole and all accessories with fitting etc. complete from the site to place located at the station as advised by concern SSE/Elect. | — | — | — | 780 | |
| — | 5.00 | — | — | ||
| Supply of material, foundation bolts etc. and casting of foundation suitable for 5 Mtrs pole with cement concrete ratio 1:2:4 as per technical specification and satisfaction to site engineer. (Supply of Octagonal Poles are not included in this NS) | — | — | — | 12,695 | |
| — | 5.00 | — | — | ||
| Erection of octagonal Pole with fixing and installation of street light fittings as instructed by site engineer including labour charges and other expenditures. | — | — | — | 2,655 | |
| — | 5.00 | — | — | ||
| Supply and fixing of hot dip galvanized second arm of suitable length on existing octagonal pole as per site. | — | — | — | 4,470 | |
| — | 4.00 | — | — | ||
| Fabrication, supply, fixing, testing and commissioning of OFF delay timer panel comprising of analogue multifunction timer with OFF delay/Signal OFF delay function with timing range adjustable upto 30 minutes minimum for OFF delay (L&T GIC model no. Micon 175 - 1CMDT0 or similar of reputed make), 3 Pole power contactor AC3-40A / AC1-55A, 240 VAC coil, 2 nos. LED based illuminated flush type push switch with 2 NC/NO contact for ON/OFF, SP MCB 6A, 10 kA 'C' series for control wiring, four terminal connecting strip 63 A min. for incoming and outgoing and other accessories including power (min. 10 sqmm copper wire) and control(min. 1.0 sqmm copper wire) wiring. Panel should have good finishing in all respect to the satisfaction of Railway authority. Panel should be as per tech spec. and its sample should be got approved by competent authority prior to supply and commissioning. | — | — | — | 20,240 | |
| — | 1.00 | — | — | ||
| Supply, fixing testing and commissioning of Astronomical timer multifunctional digital Legrand Make (Catalogue No.412657 or latest) or similar complete in all respect with suitable enclosure as per railway requirement. | — | — | — | 10,765 | |
| — | 3.00 | — | — | ||
| Design, manufacturing, supply, testing, erection and commissioning of 4 way MCCB incomer & MCCB outgoing DB panel, fabricated from 1.6mm thick CRCA sheet, powder coated with IP 42 degree of protection, complete with 250 Amp copper busbar, (Legrand cat part no. SD 2025 or similar), having provision for incomer 250 Amp, 4 pole 36kA MCCB - 1 no. and Outgoing - 100 Amp 4 pole 16kA MCCB - 2 nos., 63 Amp 4 pole 16kA MCCB - 2 nos Panel shall be manufactured from CPRI tested firm or should be of reputed switchgear manufacturer's make only. | — | — | — | 85,023 | |
| — | 3.00 | — | — | ||
| Supply, fixing and commissioning of 250 amps. 4 pole MCCB with adjustable thermal & fix magnetic trip unit, breaking cap 36 kA (min.) as incoming for DB at item no. 47 above. MCCB should be of reputed make like Legrand or similar. | — | — | — | 41,697 | |
| — | 6.00 | — | — | ||
| Supply, fixing and commissioning of 4 pole 100 Amps. MCCB with adjustable thermal & fix magnetic trip unit, breaking cap 16 kA (min.) as outgoing for DB at item no. 47 above. MCCB should be of reputed make like Legrand or similar. | — | — | — | 25,068 | |
| — | 6.00 | — | — | ||
| Supply, fixing and commissioning of 4 pole 63 Amp. MCCB with adjustable thermal & magnetic trip unit, breaking cap. 16 kA (min.) as outgoing for DB at item no. 47. MCCB should be of reputed make like Legrand or similar. | — | — | — | 22,866 | |
| — | 6.00 | — | — | ||
| Supply and fixing of Double Door MCB TPN DB SP (8+12 module), neutral and earth link, 4 way with one no. four pole MCB 63 Amp, one no. Four Pole RCCB 63 Amp 30 mA and twelve nos. SP MCB 32/25/16/10/6 Amp. 'C' series. Breaking capacity not less than 10 kA. MCB, RCCB and DB should be of same make. | — | — | — | 55,470 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing and commissioning of SPN DB 12 Way with suitable IP protection having 1 No. RCBO 40 Amp Cap., sensitivity 30 mA in the incoming and in outgoing 06 Nos. 10-32 Amp. SP MCB, 10 kA, 'C' curve, 10kA as required with bus bar, neutral bar and necessary wire sets. MCB, RCBO and DB should be of same make. | — | — | — | 22,227 | |
| — | 3.00 | — | — | ||
| Supply and fixing of MCB DP 32 Amp as per relevant IS / IEC with box. Breaking capacity not less than 10 kA. | — | — | — | 4,107 | |
| — | 5.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of MCCB 4P, 63A, 16kA Thermal & magnetic adjustable as per relevant IS / IEC. | — | — | — | 19,055 | |
| — | 5.00 | — | — | ||
| Supply and fixing of metal enclosure, powder coated, of reputed make for MCCBs upto 100A. | — | — | — | 2,675 | |
| — | 4.00 | — | — | ||
| Transportation installation testing and commissioning of water cooler including with water connection angle valve as per spec. | — | — | — | 10,328 | |
| — | 400.00 | — | — | ||
| Supply & fixing of M.S. Jaali I" x I" welded on MS angle frame 30 x 30 x 3mm which is fixed on base angle frame on 50 x 50 x 6mm and 40 x 6mm MS flat in centre to support the jaali. The whole structure including the framed jaali painted with one coat of red oxide and two coats of enamel paint. Providing roofing on rail/iron structure by MS/GI sheets with support of 50 x 50 x 6mm angle, nut-bolt and washer as per requirement. | — | — | — | 28,800 | |
| — | 4.00 | — | — | ||
| Provision of suitable foundation with concrete and cement (size 1M x 1M) for water cooler of required height as per site requirement and as per instructions of site supervisor of railway. | — | — | — | 8,708 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 25A, double pole, 30mA with Earth leakage, overload and short circuit protection as per spec and relevant IS/IEC. | — | — | — | 10,256 | |
| — | 4.00 | — | — | ||
| Supply and fixing of double hinge type FRP outdoor meter box with transparent lid to accommodate one single/three phase, electronic kWH meter and one no. DP/TP "C" series, 10 kA MCB upto 32 amp. similar to GSMB of Sintex or similar reputed make. | — | — | — | 4,324 | |
| — | 3.00 | — | — | ||
| Dismantling of overhead lines, wiring, fan, tube fittings, switch boards, pre-cooling charging points and all accessories as per site requirement and as per site engineer instructions. | — | — | — | 15,000 | |
| — | 60.00 | — | — | ||
| Design, manufacture, display of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. as per tender specs. | — | — | — | 1,30,740 | |
| — | 60.00 | — | — | ||
| Erection and installation of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. as per tender specs. | — | — | — | 13,080 | |
| — | 6.00 | — | — | ||
| SITC of Rubber Mat (ISI Mark) non-stick type suitable for 11kV AC Supply of size : 2000mm x 1000mm. The Insulation of rubber matting of 2000mm x 1000mm and thickness of not less than 25mm for HT / LT panel room shall be supplied and provided as per instructions of site engineer. | — | — | — | 6,156 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
UpdatedGCCwithACS.pdf
ATTACHMENT
RBSIGNAGESPOLICYPART-1.pdf RB Signage Policy Part 1
ATTACHMENT
RBSIGNAGESPOLICYPART-2.pdf RB Signage Policy Part 2
ATTACHMENT
JPOforprotectionofSTCables.pdf JPO for Protection of Cables
ATTACHMENT
Tender Specifications
ATTACHMENT
RBSIGNAGESPOLICYPART-1.pdf
ATTACHMENT
RBSIGNAGESPOLICYPART-2.pdf
ATTACHMENT
JPOforprotectionofSTCables.pdf
ATTACHMENT
TenderSpecsT-05-2026-27R.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].