Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.4 LAccepted-AOC RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC AOC | |
| 2 | L2₹61.5 L+₹6.7 L (12.1%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹61.7 L+₹6.9 L (12.5%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
9 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Tughlakabad
HQ CWE (AF) Tughlakabad
PROVN OF QRT REST ROOM ALONG WITH ATTACHED TOILET AND IMPROVEMENT OF DSC BILLETS AND DSC MESS (PH-I) AT 13 BRD AF STN PALAM UNDER GE(P) AF GURGAON
2020_MES_383160_2
CA NO. CWE/TKD/GUR/TOKEN-28/2020-21
Open Tender
Civil Works
Item Rate
270 days
GE (P) AF Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE (P) AF Gurgaon
₹1.3 L
Yes
30 Jan 2021
17 Nov 2020
12 Dec 2020
17 Nov 2020
9 Dec 2020
23 Nov 2020
60 days
Amount
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation and getting out in hard/dense soil complete all as specified and directed.
All as per srl item No-2 here-in-before but exc 1.50m but n exc 3.0m depth.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated material n exc. 50 m and depositing where directed at a level n, exc. 1.5 m above the starting point
M & L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
M & L for RCC M-25 using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams , mass concrete complete all as specified and directed.
M & L for RCC M-25 using 20 mm graded stone aggregates as in column ,pillars,piers,posts and struts complete all as specified and directed.
M & L for RCC M-25 using 20 mm graded stone aggregates as in lintel and roof beams all as specified and directed
M & L for RCC M-25 using 20 mm graded stone aggregates as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed
M & L for RCC M-25 using 20 mm graded stone aggregates as in chajja all as specified and directed
M & L for form work to footings, foundations, base of columns, raft beams, plinth beams, etc and similar rough finished surface of concrete complete all as specified and directed.
M & L for form work to sides of pillars,posts ,struts,columns,rough finished surface of concrete complete all as specified and directed.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports complete all as specified and directed.
M & L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M & L for form work to bottom of chajja and similar work complete all as specified and directed for rough finish flat surfaces.
M & L for form work to edges of chajja/slab and similar work n. exc 20cm wide complete all as specified and directed for rough finish flat surfaces.
M&L for MS bars TMT 10 mm dia and over ,cut to length,bent to shape requirred including cranking ,bending,spiraling for hooping for column, hooking ends and binding with and including MS wire annealed not less than 0.9 mm dia complete all as specified and directed.
M&L MS TMT bars 5mm dia and over upto and including 10mm dia , in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for brick work old size burnt clay bricks, sub class B, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for rendering 15mm thick in cement mortar 1:6 on fair surfaces for brick work or concrete surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified. Note:-Payment for providing grooves shall be made separately under respective item of this schedule..
M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
M & L for rendering 15mm thick in cement mortar 1:4 on fair surfaces for brick work or concrete surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for 5mm thick cement plaster in cement mortar 1:3 over cocrete surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for pre construction Anti termite treatment for foundation by using CHLROPYRIPHOS 20% EC emulsion @5.00Ltr/Sqm complete all as specified and directed.
M&L for pre construction Anti termite treatment for junction of wall and floor by using CHLROPYRIPHOS 20% EC emulsion @7.50Ltr/Sqm complete all as specified and directed.
M&L for pre construction Anti termite treatment for filling under floor/Plinth Protection by using CHLROPYRIPHOS 20% EC emulsion @5.00Ltr/Sqm complete all as specified and directed.
M&L for pre construction Anti termite treatment along the outer periphery of building by using CHLROPYRIPHOS 20% EC emulsion @2.25 0Ltr/Rm complete all as specified and directed.
M&L for filling under floor with approved earth in layers n exc 25cm thick including spreading watering and well ramming complete all as specified and as directed.
M&L for hardcore filling under floor and paving n exc 15cm thick by using 40 to 63mm gauge hand packed tightely all as specified and as directed.
M & L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base 75 mm thick finished even and fair complete all as specified and directed.
M & L for 75 mm thick PCC 1:3:6 type C-1 using 20 mm graded aggregates in plinth protection complete all as specified and directed by Engre-in-charge.
M &L for 30mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in floor complete all as specified and directed.
M & L for glazed ceramic tiles (600x600mm) x 7mm thick , including 15mm thick screed bed in cement mortar 1:6 laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L Non–skid ceramic coloured tiles, size 300x300x7mm in size, laid on floor,over and including 15mm thick screed bed in cement mortar 1:6 laid and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles, complete all as specified and as directed.
M&L glazed ceramic coloured tiles, 300x450x7mm to 10mm in size, set on vertical surfaces such as skirting, dado, etc,over and including 10mm thick rendering in cement mortar 1:3 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles, complete all as specified and as directed.
M&L for 15 mm thick cement plastering in cement mortar 1:4 on brick/concrete surfaces of roof and parapet, mixed with water proofing compound, finished even and smooth without using extra cement complete all as specified and as directed . Note :- Water proofing compound shall be measured & paid separately under respective item of this schedule.
Supply only liquid water proofing compound
M&L for roof treatment by applying PU & Acrylic based Elostomeric Coating in UV shafe having OVOC coating apply two coat of roof over clean plastered surface complete all per manufacturer instructions,as specified & directed by Engr-in-charge.
Material and labour for two coats of white wash after preparation of new surfaces complete all as specified and directed.
M&L for two coats of distemper over a coat of primer including putty after preparation of new surfaces complete all as specified and directed.
S&F for 25mm dia MS powder coated Curtain rod with decorative nobes on both the and MS bracket for fixing in the wall by drilling and fixing wooden gutties inclunding remove old rod complete as all specified and directed
S&F framed work such as grills, gratings, with ornamental & intricate design etc., with ends of bar shoulder and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders,framed balusters, walk ways; railings, & similar work conforming to Fe 290 GDE -E-165 complete all as specified and as directed.
S&F aluminium colour powder coated anodised door and shutter single or double leaf glazed/pre laminated board exterior quality partly glazed/pre laminated board exterior quality party glazed panels fabricated including aluminium powder coated beading rubber and packing materials and shall be drilling in existing wall and thrust bolt suitable size complete comprising the following:- (a) Aluminium colour powder coated door frame section 101.60x44.45x1.93 mm fixed as per specified.Make-Jindal /Hindalco (b) Aluminium colour powder coated vertical section in shutter 85x44.45x2 mm as per specified. (c) Aluminium colour powder coated Top Rail & style shutter section 95.25x44.45x2.00 mm as per spd. (d) Aluminium colour powder coated handle 02 Nos in each shutter 200 mm long as specified. (e) Aluminium colour powder coated Tower bolt 02 Nos in each shutter 150 mm long as per specified. (f) Aluminium colour powder coated middle lock rail/bottom rail section 150x44.45mmx2mm cat No.20002. Make-Jindal /Hindalco (g) Six lever mortice lock brass Make : Godrej/Classic on in each door. (h) 12 mm thick particular board (pre laminated both face) exterior grade ISI Marked (j) Tinted glass/Plain glass 5mm thick Make : Saint gobain/ midgaurd. (h) Floor spring , Make Sandu Note: If ground requirement for full glass or full Panel contractor shall provide as per direction of Engr-in-Charge without any extra cost to the department.
S&F aluminium colour powder coated (shade or tint as directed by GE) window frame of three track using Jindal or equivalent section No 20832 (92x31.75x1.50mm) fixed with thrust bolt in walls by drilling and sliding shutter of section No 20844 (40x18x1.29mm) or equivalent section for glass including 4.00mm thick tinted glass fixed with rubber beading and bushes complete in two track and 0.36 mm dia and 1.40mm aperture stainless steel wire mesh fixed with screw and aluminium beading in third track complete all as specified and as directed. Make-Jindal /Hindalco
S&F Aluminium colour powder coated (shade or tint as directed by GE) window frame of using Jindal or equivalent section No 20032 (61.85x31.75x1.50mm) fixed with thrust bolt in walls by drilling for half bottom and top half with top hung shutter using suitable section with 4mm thick tinted glass complete all as specified and as directed.Make-Jindal /Hindalco
S&F for PVC Solid moulded Architrave Door frame of Size 50X47mm & more made out of min 5.0mm Coloured with Plastic Trim decorated PVC Sheet Reinforced with Mild Steel Square Tube as specified Manufacture’s Instructions complete all as specified and as directed.
S&F for Factory Made PVC Solid moulded Architrave Door Shutter 30mm thick (Style) consisting of Frame made out of Mild Steel Tubes for Top and Bottom Rails, Mild Steel Frame shall be covered with heat moulded Plain Colour PVC 'C' Channel having a PVC Sheet Strip of 20mm width stuck inside with Solvent Cement for Stiles and Plain Colour PVC Sheet for Top Rail, Lock Rail and Bottom Rail on either Side and as Gap insert for Top Rails & Bottom Rail, Panelling of Plain Colour PVC Sheet to be fitted in the Mild Steel Frame welded/sealed to the Stiles and Rails with suitable PVC Sheet Beading and Joined together with Solvent Cement and fixing in the Frame at Site as per Specifications and Drawings, complete all as specified and as directed.
S&F stainless steel butt hinges 75mm, medium weight, cold rolled ISI marked and fixed complete all as specified and as directed. .
S/F 125mm long Aluminium handles, cast type anodised complete all as specified and as directed. .
S&F 150 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and as directed. .
S&F in repairs 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (Bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F 25mm thick block board gde 2, quality interior commercial type fixed with 0.9mm thick decorated laminate both side pasted with adhesive as in cupboard shutter etc. fixed with 50x20 2nd class hard wood frame alround fixed with screws, complete including necessary hinges, hesp and staple 75mm and 100mm SS handle fixed with CP screw and fixing items for wall/ floor and cup boards etc complete all as specified and as directed.
S&F 25mm thick block board Gde 2, quality interior commercial type fixed with 2nd class hard wood lipping on exposed edges as in cupboard shelves etc. fixed with screws, complete all as specified and as directed.
S&F of CPVC SDR-11 pipe 20mm dia fixed to concealed wall ceilling,laid in floor etc incl all fittings in walls and floor including all fitting and fixing with solvant and brass threaded fitting for fixing taps and valves complete all as specified and as directed.
S&F of CPVC SDR-11 pipe 25mm dia fixed to concealed wall ceilling,laid in floor etc incl all fittings in walls and floor including all fitting and fixing with solvant and brass threaded fitting for fixing taps and valves complete all as specified and as directed.
S&F vitreous china wash hand basin 630x450mm in size, white (flat back type) with 32mm dia brass chromium plated waste fitting,UPVC bottle trap, UPVC’ 32mm bore waste pipe, a pair of cast iron brackets duly painted/ erecting stand including cutting and pinning in ends, making good disturbed surfaces in cement mortar 1:3 and fixed complete all as specified and as directed.
S&F bib cock 15mm bore (dia), chromium plated long body bib cock, screwed down, screwed for iron pipe or for brass complete all as specified and as directed.
M&L for vitreous china squatting pan ‘orissa’ pattern, size 580x440 mm white, with ‘P’ or ‘S’ trap, integral foot rest, providing joints between flush pipe and socket of WC pan (excluding flushing cistern and flush pipe), fixing with and including provision of 150mm thick lime concrete bedding complete all as specified and as directed.
S&F PVC flushing cistern 10 litre capacity, low level valve less, syphonic action type, white, with inlet, ball valve, float and handle including a pair of brackets and pvc connection pipe 15mm size, pvc flush pipe of polythene 32mm dia including cutting and pinning in ends, making good disturbed surfaces in cement mortar 1:3 and fixed complete all as specified and as directed.
M&L Vitreous china wash down water closet pan (pedestal pattern) white including fixing bolts (excluding flushing cistern and flushing pipe) and fixed, including making good disturbed surfaces with cement mortar 1:3, complete all as specified and as directed..
S & F PVC water closet seat, black/white , closed pattern with flat bottom , and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repair 1000 ltrs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top three layered) hoisted and fixed in position tank Nipple for inlet, outlet, over flow and washout pipe complete all as specified and directed by Engr-in-charge .
M & L for coping in cement concret 1:2:4 type B-1 using 20mm graded stone aggregate including necessary form work complete for staging of water tank complete all as specified and directed.
S & F Gun metal globe or gate valve 20 mm dia with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S & F 15mm bore stop valve, cast copper alloy screwd down, high pressure with crutch or butterfly handle screwed down for iorn pipe or union complete all as specified and directed.
S & F PVC connection 15 mm bore size with PTMT nuts of length 450mm complete all as specified and directed.
S&F toilet paper holder of stainless steel with flap suitable for 15 CM wide toilet paper roll complete all as specified and directed.
M&L for towel ring of PTMT & including Chromium plated brass screws & wooden / plastic cleats (Minimum weight 90gm per roll complete all as specified and directed.
S&F for bras chromium plated towel rail 600mm ;long, as approved, fixed including taking down unservice-able towel rail of any description, complete as all specified and directed. (MAKE : PRIMAS/AGMECO/SONA/GEM & Eqilant)
S&F fancy type two way bath mixer with hand shower 15mm bore, chromium plated, screwed down high pressure with or without lettered ‘HOT’ or ‘COLD’ with long screwed Shanks and Fly-Nuts, screwed for Iron pipe complete all as specified and as directed.Make Cera/parrywere/jaugor.
S&F fancy type two way pillar taps mixer for 15mm bore, chromium plated, screwed down high pressure with or without lettered ‘hot’ or ‘cold’ with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed. Make Cera/parrywere/jaugor
S&F angle cock 15mm bore (dia), chromium plated, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make : Agmeco/Sona/Gem
M&L for waste coupling of PTMT (half or full thread) min wt 45 gms for 32 mm bore suitable for WHB complete all as specified and as directed.
M&L for waste pipe of PVC min 600 mm long for wash hand basin complete all as specified and as directed.
M&L machine pressed precast concrete inter locking paver block any shape and size with grey cement and no pigment conforming to is 15658-2006 of 60mm thickness , M-35 grade incl sand filling under floors or in foundations including watering and consolidation for 50mm thick complete all as specified and as directed.
S&F chromium plated health faucet, as approved, including brass CP, gun and 1.00 meter long flexible brass CP tube with stand and brass screws complete as all specified and directed.(MAKE : AGMECO/SONA/GEM)
M&L for reinforced cement concrete pipe 150mm bore class NP2 laid and jointed complete with collars as in sewer lines including jointing in cement and laid over and including PCC 1:3:6 type C-2 using 40 mm graded stone aggregate in haunchingand bedding in required slope complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making, good to pipe & rendering, cutting out existing benching channel (1/2 round or ¾ section) in ement concrete 1:2:4 type B-1 smooth finished, & reforming benching as required complete all as specified and as directed.
Removal of debris/malwa to a distance exc 10 Km but n exc 15 Km and depositing where out of defence land and directed by Engr-in-charge.
Taking down existing roof treatment, tiles/lime Koba of any description including plaster and removing all debris all as specified and directed by Engr-in charge.
Cleaning roof top surfaces by brooming, wire brushing, removing grass, raking out joints to receive plaster and removing debris, grass etc outside the defence land complete all as specified and directed by Engineer-in-Charge. Note :- (i) Providing plaster shall be measured and paid separately under appropriate item of Sch ‘A’. (ii) Rate of this item is inclusive of disconnect fitment at water tank or solar heater etc and refixing in the same position after completing of roof treatment.
M&L for PCC 1:2:4, type B-0, using 12.5mm graded stone aggregate coving, benching, roof padding as levelling course complete all as specified and directed.
M&L for applying 3.00mm thick APP based polymer membrane by torch application including sealing joint by using 85/25 industrial bitumen coat @ 1.20Kg/Sqm over bituminous primer @ 0.30 Ltr/Sqm on newly plastered clean and dry roof surface complete all as per manufacturer instructions, specified & directed by Engr-in-charge.
M&L for applying evenly two coat cemetious/liquid waterproofing coating over plastered surface in sunken slab as per manufacturer instructions including cleaned and dried surface complete all as specified and as directed. Make :- SIKA/FOSROC/STP/BOSTIK INDIA/STP
M&L for PCC 1:5:10 type E2 using 40mm graded stone aggregate as in filling under floor/sunken slab complete all as specified and as directed
M&L for mild steel angle iron work as in Jacketing of existing column by cutting welding making holes and fixing by using angle iron/flat iron of FE-410 W grade complete including necessary scaffolding upto four Storey building complete all as specified and as directed.
Taking down cement plaster, any description from brick walls or concrete surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and as directed. (4th floor and scafolding)
M&L for preparing new plastered wall surfaces and apply two coat of exterior emulsion paint 100% acrylic of approved colour and shade complete over a coat of primer all as specified and as directed by Engineer-in-charge. Make-Asian (Apex Ultima) paints/Berger (Whether Dust proof coat long life) including necessary scaffolding upto 4th floor.
Demolition of brick work masonry, built in cement mortar including all quoins, arches, pillars etc and removing rubbish from the premises complete all as specified and directed.
M&L brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
Taking down broken / unserviceable RCC jali from Building & boundary wall at any height and any position complete all as specified and as directed.
M&L for precast cement concrete type B-0 1:2:4, using 12.5 mm graded aggregate as in louvres and Jallies , 40 mm thick including all moulding at any height of bldg set in cement sand mortar 1:2 complete all as specified and as directed. (Note : - Rate inclusive of all arrangement for scaffolding and safety precautions) .
M&L for framed bracket, framed guard bars, grills for angles/Box section or tees cut to length, bent to shape, drilled & counter sunk for screw, including bending & welding angles, as necessary, gusset plates, riveting, etc., n exc 10kg each brackets, conforming to Fe 290 GDE -E-165.
Demoliation of cement concrete (Un-reinforced) of any description, not exc. 150mm thickness of floor etc and removing the same from site (s) .complete all as specified and as directed.
Dismantling of stone slab and tiles of any description or thickness in floor or wall, aprons and laid badded and pointed in any mortor etc.complete all as specified and as directed.
M&L for hold fast, pinel hinges, grills for windows, hand made sliding bolts etc fabricated out of MS flat, cleat for securing purlins and similar small articles complete conforming to Fe-410 etc.complete all as specified and as directed.
Dismantling of floor, hearth, or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over 15mm thick screed bed in cement mortar 1:4 over sub base including laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing etc complete all as specified and as directed.
M&L for Machine Cut Kota stone slab 20-25mm thick in steps of stair with nosing in single piece laid over 15mm screed bed in cement mortar 1:4 and jointed including set in neat cement slurry and pointed in white or coloured cement to match the shade of the stone including rubbing and polishing complete all as specified and as directed.
M&L for 300x300x25mm Chequered Cement Concrete Tiles pre printed colour, Set and Jointed in Neat Cement Slurry with Grey Cement and Pigment over and including Screed Bed 15mm thick in Cement Mortar (1:6) as in Path, complete all as specified and as directed. (Make: JOHNSON/coral/SP Tiles
Repairs to existing Dholpur stone by removing and refixing in cement mortar 1:4 including drilling holes one No in each stone and fixing of dash fastner to hold the existing stone all as specified and as directed.
M&L for 20mm thick Dholpur Stone Cladding gang saw cut with machine cut edges, uniform colour of stone size n exc 0.50Sqm each fixed with and including one number SS clamp Gde-202 of flat 30x2mm long made to shape/dash fastner in each slab, making v groove at top and bottom of stone and drilling holes for hold fastners and finishing complete over 15mm thick rendering in CM 1:4. all as specified and as directed.
Taking down steel tubing & connections, 20mm bore including cleaning for re-fixing or removal to store
Taking down steel tubing & connections, 15mm bore including cleaning for re-fixing or removal to store
S&F for 20mm dia CPVC SDR-11 pipe fixed to concealed wall, ceilling, laid in floor etc incl all fittings any other Situation including fittings fixed with adhesive and brass threaded fittings for fixing taps and valves etc., complete all as specified and as directed.
S&F for 25mm dia CPVC SDR-11 pipe fixed to concealed wall, ceilling, laid in floor etc incl all fittings any other Situation including fittings fixed with adhesive and brass threaded fittings for fixing taps and valves etc., complete all as specified and as directed.
S&F galvanised steel water tubing 15mm Bore (dia), ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situ-ation including Fittings and Connections, etc., complete all as specified and as directed.
S&F Galvanised Steel Water Tubing 20mm Bore (dia), ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situ-ation including Fittings and Connections, etc. complete all as specified and as directed.
S&F Angle Stop Cock 15mm Bore (dia), Brass Chromium Plated, screwed down, screwed for Iron Pipe or for Brass Ferrule and fixed-in-repairs complete all as specified and as directed.(MAKE : PRIMA/AGMECO/SONA/GEM & Eqilant)
S&F Vitreous China Soap Dish, Single, as Approved, fixing with Brass Chromium Plated Screws including Taking down unserviceable Soap Dish of any description, complete as all specified and directed.
S&F for stop valve 15mm bore, cast copper alloy CP, screwed down, high pressure with long shank with butterfly handle/Capston Head, screwed both ends for iron pipe or union and fixed in repairs complete all as specified and as directed
S&F for wash basin mixer Valve 15mm Bore, Cast Copper Alloy with Capstan Heads, Chromium Plated, screwed down high pressure with ‘HOT’ and ‘COLD’ with long screwed Shanks and Fly-Nuts, screwed for Iron Pipe and fixed-in-repairs, complete all as specified and as directed.
M&L for welding in repairs thickness of Metal to be welded n.exc 6mm
S&F in repair for Brass chromium plated shower rose 75mm size swiwel type fixed to 15 mm bore pipe all as directed by Engr-in-Charge
S&F for Two in one Bib Taps 15mm Bore, Cast Copper Alloy CP,with capston head screwed down, screwed for Iron Pipe or for Brass Ferrule and fixed-in-repairs, complete all as specified and as directed.
Taking down existing water tank of capacity 250 to 500 Ltr and refixing after necessary cleaning/water proofing treatment on roof surface including replacement of tank nipple etc complete,
S&F in repair for 500 ltrs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top three layered) hoisted and fixed in position including tank Nipple for inlet, outlet, over flow and washout pipe, complete all as specified and as directed by Engr-in-charge .
S&F in repairs for 20mm bore PTMT ball valve high pressure with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed GI Pipe complete all as specified and directed by Engineer in charge.
S&F in repair, for high pressure PVC connection pipes 450mm long with brass CP checknut with washer complete all as specified and directed by Engr in charge. Cat No-AE-06 of Make-nixo/Shakti or equivalent out of makes specified in list of makes.
Taking down AC/PVC/Salt glazed pipe upto 110 mm dia of any description and removing to store
S&F for PVC (SWR) Pipes 110mm in Bore (dia), Single Socketed, in any length with Rubber Ring Joints fixed to Walls or Laid in Floors, etc complete all as specified and as directed.
S&F for PVC (SWR) Bend suitable for PVC (SWR) Pipes 110mm in Bore (dia), jointing with Solvent Cement and fixed complete all as specified and as directed.
M&L for replacement of 100mm CI floor/nahani trap with steel grating including jointing and breaking/ dismantling any type of floor and making good cement concrete to the B-1 (1:2:4) and testing after repairs and taking down existing trap etc complete all as specified and directed by Engr-in-Charge
S&F for 75mm dia sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints fixed to wall complete all as specified and as directed.
S&F 100mm dia sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints fixed to wall complete all as specified and as directed.
S&F in repair 75mm dia CI bends, diminishing pieces or tapers with oval access door fixed with cement joint complete all as specified and as directed.
S&F in repair 100mm dia CI bends, diminishing pieces or tapers fixed with cement joint complete all as dspecified and as directed.
S&F in repair 75mm dia CI branch pieces, single (equal or unequal) ordinary or inverted (Spigot or socket type) or with paralled branches
S&F in repair 100mm dia CI branch pieces, single (equal or unequal) ordinary or inverted (Spigot or socket type) or with paralled branches
S&F stack clamp GI Channel with 10mm dia U clamp with nut bolt and washer suitable for 75 mm dia pipe and fixed to wall complete all as specified and as directed.
S&F Stack Clamp GI Channel with 10mm dia U clamp with nut bolt and washer suitable for 110/100 mm dia pipe and fixed to wall complete all as specified and as directed.
S & F in repair vitreous china half stall urinals white or colour as directed complete including fixing all accesary fittings such as waste couplin, spreader and screw etc. pointing around urinal and provision of waste pipe PVC suittable for urinal pot. Make :- Cera/Parrywere/ Hindwere/ Jaguar/ Johnson
S & F in repair vitreous china urinal partitions white complete size as fixed urinal min 310x700mm including fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plug with and including 60 mm long brass screws, pointing around urinal and all as specified and directed by Engr-in-charge. Make :- Cera/Parrywere/ Hindwere/ Jaguar/ Johnson
S&F for Stainless steel kitchen sink with draining board of overall size 915x460mm and bowl size 410x330x160mm with 1.0mm thick with steel plug,waste coupling with stoper,duly bedded and fixed in CM 1:4 to dwarf wall or with canti lever bracket and connection to drain pipe including 32mm dia PVC waste pipe all as specified and as directed.
S&F in repairs 4.0mm thick figured Glass, pin headed type, Glazing as in Window Frames fixed with exc. 0.50 Sqm in each Pane and fixed, complete all as specified and as directed.
S&F for stainless Steel Wire Cloth, 0.36mm nominal dia of Wire and average width of aperture 1.4 mm and fixed with Tinned Tacks of Mild Steel Wire Stapes, etc, complete all as specified and as directed.
S&F for Stainless steel Hat Pegs, Solid body, 75 mm to 100 mm and fixed in repairs
Taking down door/window frame with shutter of area n exc 1.50 Sqm each and removing to store.
Taking down door/window frame with shutter of area exc 1.50 but n exc 4.0 Sqm each and removing to store.
S&F for mild steel works Fe-410 or 310 as in framed works such as door frame/ grills/ guard bar with ends of bars shoulders and or riveted or forged into spiked complete all as specified and as directed.
M&L for 2nd class Factory made hard wood, 35mm thick Plain framed panelled shutters (any numbers of panels) with panels of timber flat on both sides feather edged or veneered particle board medium density with commercial face veneers and fixed to chowkats complete all as specified and directed by Engineer-in-Charge.
M&L for 2nd class Factory made hard wood, 35mm thick glazed/ skeleton shutter with glazed bar of timber flat and feather edged and fixed to chowkats complete all as specified and directed by Engineer-in-Charge.
S&F 150mm long Aluminium anodized handles, cast type fixed with flat head ss screw complete all as specified and as directed.
S&F 200 mm long aluminium anodized barrel tower bolt of extruded section fixed with flat head ss screw complete all as specified and as directed..
S&F Mild Steel Butt Hinges 100mm, Medium Weight, Cold Rolled ISI Marked and fixed, complete all as specified and as directed.
M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10cm width or grith and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
S&F aluminium colour powder coated door/Window frame including aluminium powder coated door/window frame section 101.60x44.45x1.93 mm fixed (b) Aluminium colour powder coated vertical section in shutter 85x44.45x2 mm as per spd & directed.
S&F Aluminium powder coated door shutter with aluminium section weighing n less than @0.55 Kg/Sqm fabricated including aluminium powder coated beading rubber and packing materials and shall be drilling in existing wall and thrust bolt suitable size complete comprising the following:- (a) Aluminium colour powder coated vertical section in shutter 85x44.45x2 mm as per spd & directed. (b) Aluminium colour powder coated Top & style shutter section 95.25x44.45x2.00 mm as per specified. (c) Aluminium colour anodised middle lock rail/bottom rail section 150x44x2.00mm cat No.20002. Make-Jindal (d) Aluminium colour powder coated handle 02 Nos in each shutter 150 mm long. (e) Six lever mortice lock brass Make : Godrej/Classic on in each door. (f) 12 mm thick particle board (pre laminated both face) exterior grade ISI Marked (g) Aluminium colour powder coated Tower Bolt 02 Nos in each shutter 150 mm long. (h) Tinted glass/Plain glass 5mm thick Make : Saint gobain/modi guard. (j) Hydraulic door closer-01 No, Make :- Amit or other ISI marked. Note: If ground requirement for full glass or full Panel contractor should provide as per direction of Engr-in-C.
S&F aluminium colour power coated (shade or tint as directed by GE) window/ventilator frame section 100x44x2mm fixed with thrust bolt in walls by drilling (any number of leaf) comprising the following:- (a) Aluminium colour powder coated (shade or tint as directed by GE) Single/double leaf 44x44x2mm top/bottom/sides style. (b) Stainless Steel butt/friction hinges 2 Nos in each window 75 mm sizes as per spd. (c) Aluminium colour powder coated tower bolt 2 Nos in each window 125 mm long as per spd. (d) Aluminium colour powder coated handle 1 Nos in each window 100 mm long as per spd. (e) Aluminium powder coated peg stay 300 mm long. (f) Tinted glass 4 mm thick Make-Saint gobain. modigaurd/0.36mm dia and 1.40mm aperture SS wire mesh. Note :- All fittings and fixtures provided as specified and as directed by Engr in Charge
M&L for preparation of new steel surfaces of steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc primer complete all as specified and as directed.
M&L for preparation and old decorated surfaces of steel and iron surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed.
M&L for complete removal of existing treatment from wall surface and sanding surface by sanding machine, preparing old plastered surface and applying two coats of distemper oil emulsion over a coat of primer including 2 mm thick birla putty punning complete all as specified and as directed.
M&L for preparation of old treated surfaces of wall and applying one coats of exterior emulsion paint (weather proof and Dust Proof ) complete including 3mm thick birla putty punning all as specified and as directed by Engr-in-Charge.
M&L for preparation of old surfaces of wood or wood based materials over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
M&L for gunniting RCC works in coloum, beams, slabs, ceiling,Chajjas,Facia, landing, balconies etc by remiving loose concrete including plaster, cleaning of surfaces with wire brushes and supply and fixing welded steel wire mesh 50 mm x 50 mm with 3 mm dia steel wire as facias/drops amd similar works etc and applying an epoxy resin concrete bonding agent treatment over the old concrete surface to bond with the new concrete with Nitobond EP of M/s Pidilite/M/s BASF (as per manufacurers instruction) to bond old and new concrete, gunniting with minimum pressure of 2.5 Kg per Sqcm in two layers of total avg thickness shall be 40 mm thich with cement mortor (1:2) using ordinay port land cement of 53 grade mixing with waterproofing admixture polycrete @ 2% by weight of cement complete all as specified and directed by Engr-in-Charge. Note :The following itemw shall be deemed to be included in quoted rate :- (i) Reinforcement bars and plastering to gunning surface (ii) After placing the reinforcement all concrete surface shall be throughly scrubbed with brush, washed with water and allowed to dry for plastering (iii) Work is to carried out in patches (v) Rate for scaffolding etc shall be deemed to be included in quoted rate (iv) Gunniting at Ground floor to 4 th story (vii) Anti-corrosive protective coating for reinforced bars (v) Two coat oil bound/Apex over a coat of primer over Gunniting including putty (vi) 15 mm plaster in CM 1:4 shall be done on Gunniting area (vii) Apply for Two coats of oil distermper/Apex on old surface / disturbed area
Supply and fixing of ceiling fan complete with nuts, screws, bolts of specified sizes and connecting to nearest ceiling rose 230 V, 1200 mm sweep, BEE 5 star rated complete all as specified and as directed. (Make:CG/ CAT No HS Plus - 5 star or equivalent of Bajaj/Philips/Usha)
Supply and fixing LED tubelight luminarie complete with 22 W LED 6500 K lamp complete, Ultra slim aluminium square profile LED lighting fixture with high lumen output, environmental friendly, energy efficient ready to use pack. along with fixtures (Make: Havells CAT No: LHEXBTP7IN1S022 HSN Code 9405 or equivalent of Bajaj/Philips/CG)
Supply & fixing exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver, 900 RPM (heavy duty exhaust fan) complete with nuts, screws, bolts of specified sizes and connecting to nearest ceiling rose complete all as specified and as directed. (Make :Make :CG/ CAT NO:EXHD 300-6-1or of equivalent make of Bajaj/Philips/Usha)
Material and labour for point wiring complete with 1.5 sqmm, PVC insulated,(FRLSH), unsheathed,1100 volts grade cable,with multi-stranded copper conductor single core in and including through heavy grade concealed PVC conduit of 20/25 mm dia, complete with 1.5 sqmm PVC insulated (FRLSH), copper conductor as earth wire and connected to common earth dolly for one light/fan point controlled by one, one way switch complete all as specified and directed.
All as per item No. 162 above but for 05 Amps socket outlet on same board.
All as per item No.162 above but for one 5 pin, 5 Amps socket out let on independent board with 1.5 Sqmm cable & alongwith 1.5 Sqmm continous earth wire of copper conductor(FRLSH) complete all as specified
All as per Item No. 162 above one 15/20 Amps socket out let or for sheet metal enclosure on independent board with 4 sqmm cable alongwith 2.5 Sqmm continuous earth wire of copper conductor (FRLSH) complete all as specified.
S&F switch modular type 10 Amps single pole one way 240 volts, Make:- Havells/Anchor/Crabtree/ABB
S&F socket out let modular type 5 pin 6 Amps Make:- Havells/Anchor/Crabtree/ABB
S&F twin socket modular type heavy duty out let 6 pin 6/16 Amps. Make:- Havells/Anchor/Crabtree/ABB
S&F switch modular type 16 Amps single pole one way 240 volts, Make:- Havells/Anchor/Crabtree/ABB
S&F Modular fan regulator step type 120 watt 2 modular. Make:- Havells/Anchor/Crabtree/ABB
M&L for GI box for fixing of switches 3 modular Make:-Havells/Anchor/Crabtree/ABB
M&L for GI box for fixing of switches 12 modular.Make:-Havells/Anchor/Crabtree/ABB
S&F modular white cover plate (inner & outer) 3 modular Make:-Havells/Anchor/Crabtree/ABB
S&F modular white cover plate (inner & outer) 12 modular Make:-Havells/Anchor/Crabtree/ABB
S&F DB TPN 415 Volts 4 ways double door with incomer MCCB 63 Amps TPN complete all as specified and as directed. Make: Indoasian/Havells/L&T
S&F of MCB SP-6-32 Amps,240 Volt B series type complete all as specified and as directed. Make: Indoasian/Havells/L&T
S&F sheet metal enclosure for 220 Volts 20 Amps with a three pin and earth plug top with socket and one single pole MCB 20 Amps complete as well as specified and as directed. Make: Indoasian/Havells/L&T
M&L for sub main wiring with 2 run of size 4 sqmm PVC insulated electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with, 2.5 sqmm PVC insulated copper conductor earth wire in and including concealed PVC conduit heavy duty (2 run of 4 sqmm cable and one run of 2.5 sqmm wire and one run of PVC conduit will be measured as one unit) complete all as specified and directed.
M&L for ceiling rose 63.5X23.5 mm 3 terminals, PVC/Polycarbonate, isolated body complete all as specified and directed.
M&L for Earthing complete with GI earthing plate electrode 60 cm x 60 cm x 3 mm thick,buried directly in ground (earth pit not less than 2.25m deep from ground level)with top edge of plate not less than 1.5m below normal ground level,connected to galvanized earth lead wire 4mm dia by means of bolts,nuts,check nuts and washers protected with and including 15mm dia medium grade GI pipe,complete with necessary excavation and Earth work,charcoal and salt to cover the earth plate electrode in alternate layer of 15 cm with bottom of plate resting on a layer of charcoal,watering arrangement with 20mm dia medium grade GI pipe,fixed from top layer of plate to ground layer,with PCC 1:4:8 and CI plate cover, hinged, GI funnel suitable for insertion in 20 mm dia watering pipe at GL complete with seieve etc to complete satisfaction of Engineer-in-charge,with test point and testing,commissioning all as specified as per EP no:3 of SSR part1. Size of earth pit from GL is 700mm X 700 mm X 2250 mm. Earth pit cover should be of CI cover hinged to CI frame complete with lifting handle. Size of funnel pit is 300 mm x 300 mm x 300 mm. Type of PCC is 1:4:8 cement concrete for pit as shown in EP no 3 Watering pipe is 20 mm dia GI of length 1200 mm complete all as shown in EP no 3 and all as specified and as directed.
Supply, laying and testing cable XLPE insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 4 core complete all as specified and directed
M&L for MCCB 4 Pole, 100 Amps, 415 Volts grade with 16A breaking capacity complete all as specified and directed
M&L for Sand filling, spreading and levelling in layers not exc. 25 cm after well ramming including watering as required for cable protection
M&L for bricks; common burnt clay building bricks; sub class 'B' designation 75 of old size
M&L for tubes, 'light grade', galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors for 50 mm bore complete all as specified and as directed.
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation and getting out in soft soil complete all as specified and directed.
M&L for tubes, 'light grade', galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors for 25 mm bore complete all as specified and as directed.
M&L for outdoor street light complete with die cast aluminium body, gear box complete , LED lamp and panel 100 Watt complete all as specified and as directed
M&L for tubes 'medium garde', galvanised, with all fittings; laid in trench of bore 40 mm bore complete all as specified and as directed.
M&L for tubes 'medium garde', galvanised, with all fittings and fixed complete to walls and ceilings or laid in floor of bore 25 mm bore complete all as specified and as directed.
M&L gun metal globe/gate valves, with iron wheel head, screwed both ends for iron pipes and fixed for 25 mm bore complete all as specified and as directed.
M&L gun metal globe/gate valves, with iron wheel head, screwed both ends for iron pipes and fixed for 40 mm bore complete all as specified and as directed.
Cutting existing steel tubing for alterations or additions (Each cut measured), necessarily done in position without taking down the tubing of bore 40 to 50 mm complete all as specified and as directed.
Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) without taking down of bore 40 to 50 mm complete all as specified and as directed.
M&L for construction of valve pit chamber with MS cover, 6 mm thick of valve pit size 0.60m X 0.60m X 0.45m (Internal dimensions), including necessary excavation and earth work, complete with brickwork of the walls with bottom of 100 mm thich PCC 1:4:8, type D2 as in foundation and plastering entire wall surface with 15mm thick in cement mortar 1:6 and two coat of white wash, angle iron frame fabricated out of 40mm X 40mm X 6mm angle iron and locking arrangement including painting with two coats of synthetic enameled paint over a coat of red oxide primer after preparation of surface complete all as specified and as directed.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 60/120 ltrs of approved make.
Supply and fixing desert cooler electric driven (single phase), having nominal air flow capacity of 4000 Cum per hour (or nearest size) Steel body of approved make.
Taking down of old unserviceable copper / aluminium point wiring (light, fan, socket or power) complete including fitting & fixture such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good disturbed surfaces of walls, floors etc complete.
Taking down of old unserviceable sub main wiring SPN/TPN of any capacity/Size complete all as specified and as directed.
M&L for GI box for fixing of switches 08 modular. ( Make:- Indo Asian)
S&F modular white cover plate (inner & outer) 8 modular(Make:- Havells)
Taking down any type light fitting and refixing the same complete after cleaning/washing and minor repairing work complete all as specified and as directed.
Supply & fixing bulb batten holder for fixing of LED bulb of 9W.complete with LED bulb 10W complete all as specified and as directed.
Supply & fixing PVC body exhaust fans AC single phase 230/ 240 V of size 200 mm sweep with louver for bathroom complete all as specified and as directed.Make:- Crompton/Havells/Bajaj/Philips
Supply & fixing metal body exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver for kitchen complete all as specified and as directed.Make:- Crompton/Havells/Bajaj/Philips
Supply & fix air circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting.Make:- Crompton/Havells/Bajaj/Philips
S&F DB SPN 415 Volts 8 ways double door complete all as specified and as directed.
S&F MCB 63 Amps TPN breaking capacity 10 KA, 240 Volts grade, C curve.(Make: Indo Asian/Havells/Legrand)
S&F of MCB SP-6-32 Amps, breaking capacity 10 KA, 240 Volt grade, C curve complete all as specified and as directed.(Make-Indo Asian/Havells/Legrand)
S&F of MCB SPN-40-63 Amps, breaking capacity 10 kA , 240 Volt grade, C curve single pole type complete all as specified and as directed.Make-Indo AsianIndo Asian/Havells/Legrand
M&L for sub main wiring 2 run of size 6.0 sqmm PVC insulated electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with, 6.0 sqmm PVC insulated copper conductor earth wire in concealed PVC conduit (2 run of 6.0 sqmm cable and one run of 6.0 sqmm wire and one run of PVC conduit will be measured as one unit) complete all as specified and directed.
M&L for MCCB 200A,TP,with breaking capacity of 25KA,confirming to IEC 60947-II, with electromechanical type overload protection and adjustaable overload setting of Ir=(0.8 to 1.0 )x In complete with fixed short circuit setting at Ics=100%Icu suitable for isolation complete all as specified and as directed.Make:Indoasian,CAT No:830291 HSN code;8536 or equivalent of Legrand/Havells/L&T.
M/S Parshant Associates
Shiv Shankar Nirman Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .