Loading…
Loading…
Tender Value
₹3.8 L
EMD Value
₹7,600
Closing Date
22 Jul 2026, 2:00 pm
AE
138, AJC BOSE ROAD, KOLKATA-14
NRS MEDICAL COLLEGE AND HOSPITAL LADY DOCTOR HOSTEL 10TH FLOOR MINOR REPAIRING OF DAMAGED WALL AND CEILING ALONGWITH PAINTING WITH NECESSARY SAND P FITTINGS IN TOILET BLOCK AND OTHER ALLIED WORKS DURING THE FY 2026 2027
2026_WBPWD_5016448_7
WBPWD/AE/NRSH/NIT-06/2026-27
Open Tender
CIVIL WORKS
30 days
NRSMC and H
Please refer Tender documents.
4 documents required · 4 mandatory
₹7,600
Yes
7 Jul 2026
7 Jul 2026
24 Jul 2026
7 Jul 2026
22 Jul 2026
10 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Stripping off worn out plaster and raking out joints of walls, celings etc. up to any height and in any floor including removing rubbish with in a lead of 75 m as directed. . | 170.16 | SQM | 22.64 | ₹3,852.42 |
| 2 | Cleaning the exposed reinforcement preferably upto full diameter by wirebrush, applying two coats of polymer based rust removing compound left for24 hours, removing the coating and then applying two (2) coats of polymermodified anti corrosive protective coating formulated to inhibit the corrosionof reinforcement as per manufacturer's specification] [Mode ofmeasurement:The affected surface area of reinforcement shall beconsidered for payment] | 5.03 | SQM | 931.99 | ₹4,687.91 |
| 3 | Applying epoxy based reactive joining agent for joining the old concrete withfresh concrete to be applied within manufacturer's specified time as permanufacturers specification. (0.4 Kg / m² of concrete surface). Note: Applicable only when the full diameter of reinforcement steel isexposed. | 50.26 | SQM | 368.27 | ₹18,509.25 |
| 4Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributing the same and with proper scarping and cleaning the reinforcement and disturbed concrete with wire brush etc. after applying a coat of cement including the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge. | |||||
| 4.01 | b) 25 mm thick | 50.26 | SQM | 615.16 | ₹30,917.94 |
| 5Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering conrners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (ground floor). [Excluding cost of chipping over concrete surface]. | |||||
| 5.01 | (ii) With 1:4 cement mortar . | - | - | - | - |
| 5.02 | (b) 15 mm. thick plaster. (Add. above ground floor - 10th. floor) | 119.9 | SQM | 231.87 | ₹27,801.21 |
| 5.03 | (ii) With 1:4 cement mortar . | - | - | - | - |
| 5.04 | (c)10 mm. thick plaster. (Add. above ground floor - 10th. floor) | 50.26 | SQM | 210.41 | ₹10,575.21 |