XeN Mechanical Central Kmr RnB Rajbagh
Office of XeN Mechanical Central Kmr RnB Rajbagh PMGSY Building
SITC of HVAC system for under construction residence of Honble Chief Justice JK UT at Zeethyar Gupkar Srinagar
2025_PWDJK_276249_1
RnB/MDCK/NIT/03
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
60 days
Gupkar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,600
Executive Engineer RnB Mechanical Central Kmr
₹1.7 L
10 May 2025
25 Apr 2025
5 May 2025
26 Apr 2025
3 May 2025
26 Apr 2025
Amount
VRF Outdoor Unit (HEAT PUMP TYPE) Supply Installation, Testing & Commissioning of imported modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. VRF unit and compressor shall be of same OEM make. Latest BEE guideline for AC system/ECBC/GRIHA/AHRI whichever guidelines is more stringent shall be followed based on GRIHA star rating requirement of building. The VRF units shall be able to deliver 100% capacities at AHRI conditions till ambient temperature of 39 deg C. For improvement in efficiency other than ISEER value, the VRF units will with minimum COP of 3.5 at 100% load at AHRI conditions in heating. The VRF outdoor unit shall have operating range from 0 deg C to 50 deg C in cooling mode & -20 Deg C to 15 Deg C in heating mode and the OEM shall submit catalogue for VRF unit, mentioning the same. In case of one IDU fails or stops working for any reason during the running of the system, the VRF System must have provision or capability to by pass so that the whole circuit should not get affected.The unit shall be complete individual controller and fittings with necessary wiring, connection & termination, painted MS frame for outdoor unit, cowl for ODU etc.Capacity of ODUs as following
Indoor VRV Units (Nominal Capacity) - Ceiling Mounted High Static Ductable Type Unit Supply, installation, testing and commissioning of following minimum capacity and high external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, hig lift drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System.
4.0 TR-Standard VRF Ductable TFA unit with all controls & accessories
6.4 TR-Standard VRF Ductable TFA unit with all controls & accessories
Indoor VRV Units (Nominal Capacity) - Ceiling Mounted Cassette Round Flow/4Way type unit. Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, high lift drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System.
Supply,Lifting, shifting, positioning, installation, testing & Commissioning of fittings Y-joints/refnets and headers for all Indoor & Outdoor units.
Supplying, fixing, testing and commissioning of Main centralized controller with advanced technology (Touch Screen type/Push Button type) uitable for groups of indoor units to be installed for control (BMS Compatible). All required accessories (hardware and software) to be provided for BMS connection. Controller shall have software for automation (ON/OFF, scheduling, lock/unlock, temperature setting, error detection) of entire system, all indoor units add monitoring of corresponding outdoor units from one central location. Controller should be BMS (like Bacnet, Lan works, Modbus) compatible. It must show the status of all indoor units along with outdoor unit. All required accessories (hardware and software) to be provided for BMS connection. Controller should capable to provide all detail like Fail safe logic. ON/OFF sequencing. Central controller complete with necessary hardware, accessories etc. shall be provided for controlling all the IDUs& ODUs with 15% spare.
REFRIGERANT PIPING Supply, Installation, testing and commissioning including vaccumiazation ,nitrogen flushing during brazing and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with EPDM Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required .Pressure testing to be done at 1.5 times the working pressure.Piping vaccumiazation ,nitrogen flushing during brazing and Nitrogen testing to be done by contractor and price for the same to be included.Thickness of pipes should be as per VRF manufacturer's recommendation.
34.9 mm dia (OD) (Hard drawn) with 19mm thick insulation
28.5/31.8 mm dia (OD) (Hard drawn) with 19mm thick insulation
22.2/25.4mm dia (OD) (Hard drawn) with 19mm thick insulation
19.1 mm dia (OD) (Hard drawn) with 19mm thick insulation
15.86 mm dia (OD) (Soft drawn) with 13mm thick insulation
12.7 mm dia (OD) (Soft drawn) with 13mm thick insulation
9.5 mm dia (OD) (Soft drawn) with 13mm thick insulation
6.4mm dia (OD) (Soft drawn) with 13mm thick insulation
Drain Piping Supply & fixing of heavy duty PVC Pipe complete with fittings, supports as per specifications and duly insulated with 9 mm thickness of closed cell nitrile rubber/ EPDM insulation as required & as per specifications.
40 mm dia with 9 mm thick insulation
32 mm dia with 9 mm thick insulation
25 mm dia with 9 mm thick insulation
CONTROL CABLES
Providing and fixing of suitable size of shielded armoured control cable required for IDU to ODU connection complete in all respect & as required. Size of cable as per Manufacturer recommedation.
Providing and fixing of control cable of 3 Core x 1.5 sqmm. shielded copper cable in Heavy duty PVC conduit (20mm dia.) complete in all respect & as required.
Providing and fixing of control cable of 2 Core x 1.5 sqmm. shielded copper cable in Heavy duty PVC conduit (20mm dia.) complete in all respect & as required.
Providing and fixing of control cable of suitable size required for corded remote (shielded cable in Heavy duty PVC conduit (20mm dia.)) complete in all respect & as required.
100 CFM, 8mm Static Pressure
150 CFM, 8mm Static Pressure
200 CFM, 8mm Static Pressure
300 CFM, 10mm Static Pressure
1000 CFM, 10mm Static Pressure
Propeller Fans ( For Residential Purpose) Supplying, installation, testing & commissioning of low noise Plastic body circular/rectangular Propeller exhaust fans suitable for following capacities complete with electric motor suitable for operation on 220 V+ 10%, 50 Hz, 1 phase AC supply, 6 Amp plug and wiring between the fan and the socket, fitted with mounting frames, NRD/ louvers/bird screen etc. as per specifications of the following capacities.
150mm dia
300mm dia
GSS DUCTING Supply, installation, balancing and commissioning of GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Thickness 1.25 mm sheet
SITE FABRICATED GSS DUCTING Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Thickness 1.25 mm sheet
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supply, installation, testing of extruded aluminium powder coated linear grill without volume control damper as per drawings.
Supply, Installation and Testing of collar damper of galvanised steel sheet, provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution as per approved shop floor drawings and specifications.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Supply, fixing and commissioning of Fresh/ exhaust air louvers with section comprising of powder coated Aluminium louvers & bird screen as required.
Supply, fixing and commissioning of powder coated extruded aluminium Door Transfer Grill complete with nuts, bolts, SS screws etc. complete as required.
Supply and Installation of 2Hr. Fire Resistant Fabric Flexible Connection to be installed between all the IDU and the ducting to provide flexibility of movement in case of a seismic event and to prevent transmission of vibration from the unit to the duct.
PREINSULATED FLEXIBLE DUCTING Supplying and fixing of the round flexible duct inner core should be made of double lamination of Aluminum Foil, Polyester & Metalized polyester film permanently bonded to a coated spring steel wire helix. Fiberglass insulation shall be of 25mm thick with minimum density of 16 kg/m³. The outer insulation jacket vapor barrier shall be made of fiber glass reinforced metalized polyester film laminated with aluminum foil. Both the end connections shall be through double 'O' rings. The preinsulated duct shall be UL listed.
100 mm Dia.
150 mm Dia.
METALLIC FLEXIBLE DUCTING Supply, installation, testing & commissioning of Al uninsulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications.
100 mm Dia.
150 mm Dia.
Supply, Installation and Testing of single piece GI round spigot made out of spinning process with 50mm height and having grooves on both sides and circular flanges. Spigots shall be installed on main ducts to facilitate connection of flexible ducts.
100 mm Dia.
150 mm Dia.
Supply, installation, testing and commissioning of GI butterfly volume control duct damper suitable to connect one side with GI duct and other side with flexible duct complete with air tight fastening arragement including neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications.
100 mm Dia.
150 mm Dia.
Supply,Installation ,Testing and commissioning of single slot trimeless slim line diffusers complete as required and as per approved shop drawings and colour .
Supply, Installation,Testing and commissioning of powder coated extruded aluminium 2-slot diffusers as per approved drawings and colour .
Supply, Installation,Testing and commissioning of powder coated extruded aluminium 3-slot diffusers as per approved drawings and colour .
Supply, Installation,Testing and commissioning of black painted aluminum hit & miss volume control damper which will be key operated as per approved shop drawings and colour .
Supply, Installation ,Testing and commissioning of plenum box made from galvanised sheet steel (min. 22G) and is supplied self-finish. Plenums are manufactured with a 15mm internally formed flange at each end, with factory fitted foam seal. Plenum box comprises a casing with horizontal circular spigot for duct connection, with spigot mounted perforated trimming damper adjustable through front face complete as required as approved shop drawing and specfication
Supply, installation & testing of GI back draught dampers similar construction of gravity louvers provided with suitable links to prevent the back pressure of air.Back draft damper to be provided at the discharge side of the fan.
DUCT ACOUSTIC LINING:- Supplying and fixing of 15mm thick of Acoustic Insulation Inside the Duct with Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 & shall be fibre free. The material shall have a thermal conductivity not exceeding 0.047 W/m.K @ 20 Deg. C & shall conform to Class 1 rating for surface spread of Flame in accordance to BS 476 Part 7. The insulation shall pass Air Erosion Resistance Test in accordance to ASTM Standard C 1071-05 (section 12.7), from an independent testing agency & should have built-in Ultra-Fresh Anti-Microbial Protection, and should pass Fungi Resistance as per ASTM G21 & Bacterial resistance as per ASTM 2180. To be applied using Adhesive.
DUCT THERMAL INSULATION Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.Duct shall be Al foiled mat finished closed cell Elastomeric Nitrile Rubber of Thermal conductivity of the insulation material shall not exceed 0.037 W/m°K at an average temperature of 20 degree C. Density of the nitrile rubber shall be 40-60 Kg/m3. The product shall have temperature range of -40 degree C to 105 degree C. The insulation material shall be fire rated for Class 0 as per BS 476 Part 6 : 1989 for fire propagation test and for Class 1 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability shall be not less than 0.024 per inch i.e. μ>7000: Water vapour diffusion resistance).
19mm Thick
MAIN ODU PANEL Supplying, of dust, damp and vermin proof free floor mounted, outdoor type(IP66) standing factory built sheet steel enclosed modular construction extendable ODU panel, suitable for operation on 415 ±10% volts, 50 Hz AC 2 phase 4 wire system fabricated out of suitable sized square tubular section and covered with CRCA sheet steel of 2mm thick for frame work and covers, 2mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, complete with Aluminium bus bars, inter-connection with copper conductor wires / aluminium strips, neutral links, earth bus etc. necessary metering protections & indications and mounted with the following as per drawing and technical specifications attached etc. complete as required. including control wiring with 1.5sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor S/C cable for voltage & current respectively, cable alleys, cable gland plates in two half, etc. necessary metering protections & indications and mounted with the following switch gears as per drawing and technical specifications etc. complete as required. Incoming: 160 Amp FP, 25 kA MCCB - 1No. 3 Nos. Phase indication LED lamps with 2 Amps back up MCB, breaker ' ON/OFF' indicating light with 2A MCB 1 No. Intelligent multi-function digital panel meters of class 0.5 accuracy with communication interface port R 485 for recording V (Between Phases and between each phase and neutral, A (In each phase and neutral), KWHr with suitable rating CTs, CT shorting links, R,Y, B LED indicating lamp and 2 A control SP MCB's. Bus Bar 200 Amp. 25 kA, FP Al. Bus Bar Outgoings: Following rated 415V, ELCB's (100mA) with earth leakage, all indication & door interlock complete in all respects for each ELCB 63Amp 4P, ELCB, 25kA - 4 Nos. 40Amp 4P, ELCB, 25kA -6 Nos. 32Amp 4P, ELCB, 10kA - 2Nos. MAIN ODU PANEL as above
Supply, laying testing and commissioning of following sizes of XLPE insulated PVC sheathed armoured Copper conductor cable of 1.1 KV grade on existing cable tray / surface including clamps, ties etc. as required.
4 Core 25 Sqmm.
4 Core 16 Sqmm.
4 Core 10 Sqmm.
4 Core 6 Sqmm.
Supplying and making end termination with brass compression glands and Al. lugs for following size of PVC insulated and PVC sheathed / XLPE Al. conductor cable of 1.1 KV grade as required.
4 Core 25 Sqmm.
4 Core 16 Sqmm.
4 Core 10 Sqmm.
4 Core 6 Sqmm.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required
100 mm. Width x 50mm. Depth x 1.6mm. Thickness.
150 mm. Width x 50mm. Depth x 1.6mm. Thickness.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 3 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
M/S STAR NEOTECH ENGINEERS (BID ID -2365549)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .