Loading…
Loading…
Tender Value
₹4.6 Cr
EMD Value
₹9.2 L
Closing Date
10 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
DRAWING
29 conditions · 9 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a) Attested Certificates(s) issued by Executive or Nominated Authority of the government Departments or Semi-Government/Public Sector Undertakings for the value of the work done for them during the qualifying period including current financial year certifying the bill amounts paid Agreement-wise and Date-wise or attested photo copy of such certificate. Such certificates will be accepted only from Govt. / Govt. bodies / PSUs authorities. Certificates issued by Private Bodies will not be considered.
(b) Audited Balance Sheets clearly indicating contractual receipts from the works done for Govt./ Govt. bodies / PSUs/Pvt. Organization in the P&L Account of the balance sheet duly certified by the Chartered Accountant for the completed & current Financial years.
NOTE: (i) Financial Year shall normally, be reckoned as 1st April to 31 st March of the Next Year. However, for Turnover Criteria, the Financial Year as applicable to the Company /Tenderer is to be considered, if it defers from the above. (ii) Current Financial year is reckoned as the incomplete Financial year in which the date of tender submission falls. (iii) Chartered Accountant statements duly indicating yearly receipts will not be considered until and unless backed by Audited Balance Sheets. (iv) If the tender is not accompanied by the certificate(s) in support of financial eligibility as above, the tender shall be rejected. No post-tender correspondence will be entertained.
If JV firms are allowed to participate; Financial eligibility of the JV Firm shall be adjudged based on satisfactory fulfilment of the Para No.17.15.2 of part-I of IRSGCC- 2019 for J.V guide lines (with upto date correction slip).
NOTE: If the tender is not accompanied by the certificate(s) in support of financial eligibility as above, the tender shall be rejected. No post-tender correspondence will be entertained.
valid Electrical Contractor license: "The tenderer shall possess a valid Electrical Contractor License, issued by any State Government or Union Territory Administration, authorizing execution of electrical works up to 650 V. The contractor shall have in his employment or shall engage a person holding a valid certificate of competency issued by any State Government or Union Territory Administration for supervision of electrical works up to 650 V. Offers not accompanied by a valid Electrical Contractor License and requisite Supervisor competency for works up to 650 V shall be summarily rejected". The License should have been issued on a date prior to the date of Tender opening. Clear scanned copy is to be submitted along with the tender. A copy of license should be uploaded through IREPS with their offer, failing which the tender will be rejected.
Similar Nature of work: "Works of installation, testing and commissioning (With or without supply) of any type of air conditioning or refrigeration systems or air cooling system (or) repairing/modification/AMC of any type of air conditioning or refrigeration systems or air cooling systems" a copy of similar nature of work should be uploaded through IREPS with their offer, failing which the tender will be rejected.
94 conditions · 9 needing a document upload
TENDER SHALL BE REJECTED if it is not accompanied by the following:
Cost of tender document & EMD deposited through IREPS e- payment
In case of Partnership firm : The tender form shall be submitted only in the name of partnership firm.
In case tenderer is JV Firm : The tender form shall be submitted 1.1.2 only in the name of the JV and not in the name of any constituent member.
Uploading of Certificate in support of Technical Eligibility (As detailed in Standard Technical Criteria).
Submission of Certificate(s) in support of Financial Eligibility (As detailed in Standard financial criteria).
IN CASE OF ADVERTISED TENDER VALUE IS MORE THAN RS. 20 CRORES: Bid capacity is applicable, the tenderers should submit proforma attached in DOCUMENTS. In case, the tenderer/s failed 1.3.1 to upload BID CAPACITY PROFORMA along with offer, their/his offer shall be considered as incomplete and will be rejected summarily.
In case tenderer is other than sole proprietorship firm, following documents shall be uploaded by the tenderer:
In case the Tenderer is a Partnership Firm: [i] Partnership deed . [ii]Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered). [iv]An undertaking by all partners of the partnership firm that they are not blacklisted or 1.4.1 debarred by Railways or any other Ministry / Department of the Govt. of India / any State Govt. from participation in tenders / contracts as on the date of opening of bids, either in their individual capacity or in any firm in which they were / are partners. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii) a copy of Power of Attorney/Authorisation 1.4.2 issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. (iv) copy of PAN number of the LLP Firm
In case the Tenderer is a Company registered under Companies Act-2013:(i) the copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company; and (ii) A copy of 1.4.3 Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.(iv) copy of PAN number of the Company.
In case the Tenderer is a Registered Society & Registered Trust: (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the 1.4.4 individual to sign the tender documents and create liability against the Society/Trust. (iv) copy of PAN number of the Society/Trust.
Incase JV Firms are allowed to participate: Uploading of MEMORANDUM OF UNDERSTANDING as per the format given in "Documents attached with tender" and also below documents.
In case one or more members is/are Proprietary Firm or HUF, the following documents shall be enclosed:: A copy of notarized affidavit on Stamp Paper declaring that his/her Concern is a 1.5.1 Proprietary Concern and he/she is sole proprietor of the Concern OR he/she is in position of "KARTA" of Hindu Undivided Family (HUF) and he/she has the authority, power and consent given by other partners to act on behalf of HUF.act on behalf of HUF.
In case one or more of the members of the JV is/are partnership firm(s), following documents shall be submitted:]:(a)A copy of the Partnership Deed, (b)A copy of consent of all the partners or individual authorized by partnership firm, to enter into the Joint 1.5.2 Venture Agreement on a stamp paper, (c)A copy of Power of Attorney (duly registered as per prevailing law) in favour of the individual to sign the MOU/JV Agreement on behalf of the partnership firm and create liability against the firm.
In case one or more members of the JV is/are companies, the following documents shall be submitted: (a)A copy of resolutions of the Directors of the Company, permitting the company to enter into a JV agreement, (b) A copy of Memorandum and 1.5.3 Articles of Association of the Company. (c) A copy of Authorization/copy of Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender, sign MOU/JV Agreement on behalf of the company and create liability against the company.
IN CASE THE TENDER VALUE MORE THAN RS. 50 LAKHS; Tenderers shall submit a notarized affidavit on a non-judicial stamp paper stating that all their statements / documents submitted along with bid are true and factual.
Uploading of Declaration regarding Employment of Retired Engineer/Retired Railway Officer as per clause no.17 of Part-I of IRSGCC. [in the format attached in - Documents]
Uploading of NEFT FORM - as per the format attached with the tender document.
The list of personnel / organization on hand and proposed to be engaged for the tendered work.
List of Plant & Machinery available on hand and proposed to be inducted and hired for the tendered work.
Uploading of Statement Showing the particulars of Works on Hand & Works Completed as per the format attached to the tender document.
Uploading of certificate by local suppliers in regard to meeting the Minimum Local Content requirement to avail benefits under Public Procurement Policy Order-2017 (A) for procurement order of value less than Rs. 10 crores: self certificate in accordance with Para-9(a) of Public Procurement(Preference to Make in India) Order 2017. (B) For Procurement Order of value more than Rs. 10 crores, the certificate from Statutory auditor/cost auditor/practicing CA as the case may be in accordance with Para-9(b) of Public Procurement (Preference to Make in India) Order 2017.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
IN CASE OF SINGLE PACKET TENDERS; CONSORTIUM AGREEMENTS, JOINT VENTURE FIRMS AND MOUS SHALL NOT BE CONSIDERED
IN CASE OF TWO PACKET TENDERS CONSORTIUM AGREEMENTS AND MOUS SHALL NOT BE CONSIDERED . BUT JOINT VENTURE FIRMS ARE CONSIDERED FOR ELIGIBILITY.
CONDITIONS FOR PARTICIPATION OF PROPRIETARY FIRM / PARTNERSHIP FIRM /PRIVATE LIMITED COMPANY / LIMITED COMPANY/ JV FIRMS:
In case the tenderer is an individual / proprietary concern, the experience and turnover shall be in the name and style of the Individual / Proprietary concern only.
In case the tenderer is a Partnership Firm, the experience and received contractual payments shall be in the name and style of the firm only. The other guidelines at Clause 18 of Part I of 4.1.1 IRSGCC shall be applicable . Note: The partner of a Partnership Firm cannot claim the credentials of Partnership firm to the extent of his share either during the subsistence of the Partnership firm or after its dissolution.
FOLLOWING DOCUMENTS SHALL BE ENCLOSED:
In case the Tenderer is a Partnership Firm: [i] Partnership deed . [ii]Power of Attorney (duly registered as per prevailing law) in favour of an individual to sign the tender documents and create 4.2.1 liability against the Firm. [iii] PAN / TAN number of Partnership firm (PAN / TAN number in the name of any of the constituent partners shall not be considered).
In case the Tenderer is a Company registered under Companies Act-2013:(i) the copies of MOA (Memorandum of Association) and AOA (Articles of Association) of the company; and (ii) A copy of Authorization/Power of Attorney issued by the Company 4.2.2 (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.(iii) copy of PAN number of the Company.
In case of JOINT VENTURE (JV) FIRMS: Clause No.17 of Part-I of IRSGCC with upto date correction slip shall be applicable in all aspects for Participation of Joint Venture[JV] firms in works tenders. JV firm should submit Memorandum of 4.2.3 Understanding[MOU] as per the format attached as annexure to the tender in DOCUMENTS. Submission of all other documents by JV firm / Members of JV should also be as per Cl.No.17.14 of Part-I of IRSGCC.
In case the Tenderer is a LLP Firm registered under LLP Act-2008 (i) a copy of LLP Agreement, (ii) a copy of Certificate of Incorporation; and (iii) a copy of Power of Attorney/Authorisation 4.2.4 issued by the LLP Firm in favour of the individual to sign the tender on behalf of the LLP Firm and create liability against the Firm. (iv) copy of PAN number of the LLP Firm
In case the Tenderer is a Registered Society & Registered Trust: (i) a copy of the Certificate of Registration, (ii) Deed of Formation; and (iii) a copy of Power of Attorney in favour of the 4.2.5 individual to sign the tender documents and create liability against the Society/Trust. (iv) copy of PAN number of the Society/Trust.
Uploading of other relevant documents connected to the tender; such as Declaration regarding employment of Retired Engineer/ Retired Railway officer, NEFT Form, List of Personnel/Organization, List of Plant/machinery, Particulars of works on hand and completed (As per the formats attached in the list of Documents)etc.
Hyderabad Division: Replacement of Codal Life Completed AC Plants in Dialysis Centre, Rail Kalarang, Rail Nilayam Auditorium
28-OEW-26-27-SrDEE-M-HYB~SCR
28-OEW-26-27-SrDEE-M-HYB
Open
Works - General
12 Months
Hyderabad, Telangana
₹0
₹9.2 L
17 Aug 2026
17 Aug 2026
27 Aug 2026
209 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 4,58,21,205 | ||
| — | 8.00 | — | — | ||
| Supply of 23 TR Air Cooled packaged AC unit with air condenser, condenser fan and motor packaged air conditioning units with all connected accessories | — | — | — | 73,95,792 | |
| — | 8.00 | — | — | ||
| Installation, testing and commissioning of 23 TR Air Cooled packaged AC unit as per the direction of engineer at site. | — | — | — | 3,60,000 | |
| — | 8.00 | — | — | ||
| Pressure testing with Nitrogen, Vacuumizing and initial charge of refrigerant gas into air conditioning system of 23 TR Air Cooled packaged AC unit as per the direction of engineer at site | — | — | — | 6,80,000 | |
| — | 8.00 | — | — | ||
| Supply & fixing of suitable size of M S "C" channel angle for the base height of 23 TR Indoor Packaged unit as per the direction of engineer at site with all connected accessories | — | — | — | 3,60,000 | |
| — | 8.00 | — | — | ||
| Supply & fixing of suitable size of M S "C" channel angle for the base height of 23TR ACs Outdoor unit (1set = 2nos) as per the direction of engineer at site with all connected accessories | — | — | — | 2,00,000 | |
| — | 13.00 | — | — | ||
| Supply of 11 TR Air Cooled packaged AC unit with air condenser, condenser fan and motor packaged air conditioning units | — | — | — | 58,03,187 | |
| — | 13.00 | — | — | ||
| Installation, testing and commissioning of 11 TR Air Cooled packaged AC unit as per the direction of engineer at site | — | — | — | 1,91,750 | |
| — | 13.00 | — | — | ||
| Pressure testing with Nitrogen, Vacuumizing and initial charge of refrigerant gas into air conditioning system of 11 TR Air Cooled packaged AC unit as per the direction of engineer at site | — | — | — | 5,85,000 | |
| — | 13.00 | — | — | ||
| Supply & fixing of suitable size of M S "C" channel angle for the base height of 11 TR Indoor Packaged unit as per the direction of engineer at site with all connected accessories | — | — | — | 2,60,000 | |
| — | 13.00 | — | — | ||
| Supply & fixing of suitable size of M S "C" channel angle for the base height of 11TR ACs Outdoor unit (1set = 2nos) as per the direction of engineer at site with all connected accessories | — | — | — | 2,40,500 | |
| — | 1260.00 | — | — | ||
| Supply & erection of Packaged AC Hard Drawn Copper refrigerant piping interconnecting the indoor unit and air cooled condenser of 22 TR & 11TR Packages AC Plant units as per the direction of engineer at site | — | — | — | 31,96,620 | |
| — | 3.00 | — | — | ||
| Supply of ductable type air conditioner of 8.5 TR Inverter ductable unit (copper wounded) with gas and all connected accessories | — | — | — | 7,48,800 | |
| — | 3.00 | — | — | ||
| Installation, testing & commissioning of 8.5 TR Inverter ductable unit with gas top up for outdoor units including lifting and shifting of the machines. | — | — | — | 37,170 | |
| — | 3.00 | — | — | ||
| Pressure testing with Nitrogen, Vacuumizing and initial charge of refrigerant gas into air conditioning system of 8.5 TR Air Cooled Ductable Split AC as per the direction of engineer at site | — | — | — | 1,05,000 | |
| — | 3.00 | — | — | ||
| Supply & fixing of suitable size of M S "C" channel angle for the base height of 8.5 TR Air Cooled Ductable Split AC as per the direction of engineer at site | — | — | — | 15,000 | |
| — | 3.00 | — | — | ||
| Supply & fixing of suitable size of M S "C" channel angle for the base height of 8.5TR ACs Outdoor unit as per the direction of engineer at site | — | — | — | 27,750 | |
| — | 250.00 | — | — | ||
| Supply & erection of Packaged AC Hard Drawn Copper refrigerant piping interconnecting the indoor unit and air cooled condenser of 8.5TR ductable AC unit as per the direction of engineer at site | — | — | — | 4,62,500 | |
| — | 1800.00 | — | — | ||
| Supply and fixing of fabricated 20 gauge G.I. Ducting with complete accessories like TDF Flanges, anchor fasteners, MS angles, support rods and extended gas kit | — | — | — | 3,78,000 | |
| — | 9250.00 | — | — | ||
| Supply and fixing of fabricated 22 gauge G.I. Ducting with complete accessories like TDF Flanges, anchor fasteners, MS angles, support rods and extended gas kit | — | — | — | 16,65,000 | |
| — | 18500.00 | — | — | ||
| Supply and fixing of fabricated 24 gauge G.I. Ducting with complete accessories like TDF Flanges, anchor fasteners, MS angles, support rods and extended gas kit | — | — | — | 26,82,500 | |
| — | 27750.00 | — | — | ||
| Supply and erection of acoustic insulation of initial part of supply air ducting with 13/12 mm thick fiber glass covered with aluminium perforated sheet as per the direction of engineer at site | — | — | — | 54,11,250 | |
| — | 1470.00 | — | — | ||
| Supply, fabrication, erecting of MS Chanel of size angle, size: 50x50 mm, thickness: 6 mm with 10mm threaded rods for duct supporting as per the direction of engineer at site | — | — | — | 4,96,860 | |
| — | 1740.00 | — | — | ||
| Supply, fabrication, erecting of MS Chanel of size angle, size: 25x25 mm, thickness: 3 mm with 8mm threaded rods for duct supporting as per the direction of engineer at site | — | — | — | 4,87,200 | |
| — | 7800.00 | — | — | ||
| Supply and erection of Insulation of duct with 9mm nitrile rubber faced with aluminum foil all around the duct as per the direction of engineer at site | — | — | — | 8,19,000 | |
| — | 1850.00 | — | — | ||
| Supply and erection of Aluminum powder coated Grills with damper as per the direction of engineer at site | — | — | — | 23,12,500 | |
| — | 24.00 | — | — | ||
| Supply and erection of G.I. Duct Dampers suitable for the indoor unit | — | — | — | 4,68,000 | |
| — | 1.00 | — | — | ||
| Supply and laying of piping for markup water and drain connections 1' Pipe line for all the AC plants as per the direction of engineer at site | — | — | — | 50,000 | |
| — | 18.00 | — | — | ||
| Lifting of Indoor Unit to floors Air Cooled packaged AC unit as per the direction of engineer at site | — | — | — | 3,24,000 | |
| — | 2800.00 | — | — | ||
| Supply, laying, connecting and commissioning of 4 core 2.5 mm sq.mm multi stranded FRLS cu. Conductor for AC as per the directions of Engineer at site | — | — | — | 5,82,400 | |
| — | 1200.00 | — | — | ||
| Supply, laying, connecting and commissioning of 4 core 4 mm sq.mm multi stranded FRLS cu. Conductor for AC as per the directions of Engineer at site | — | — | — | 4,38,000 | |
| — | 735.00 | — | — | ||
| Removing of existing AC ducts same to be handed over to SSE's stores as per the direction of engineer at site | — | — | — | 58,800 | |
| — | 3.00 | — | — | ||
| Supply of scaffolding for erection of ducting wall, Opening, Duct Insulation, hanging of GI Angles etc. as per the direction of engineer at site | — | — | — | 84,000 | |
| — | 1.00 | — | — | ||
| Shifting and re-installation of 8 Tr VRF Ductable Indoor unit to Cath Lab to integrate with 16 Tr existing VRF Plant including connected accessories etc., as per the direction of engineer at site | — | — | — | 18,500 | |
| — | 1.00 | — | — | ||
| Provision of dummy to existing copper line of 16 Tr VRF AC unit as per the direction of engineer at site | — | — | — | 16,900 | |
| — | 1.00 | — | — | ||
| Pressure testing with Nitrogen, Vacuumizing and initial charge of refrigerant gas into air conditioning system of 16 Tr VRF Unit AC unit as per the direction of engineer at site | — | — | — | 83,158 | |
| — | 1.00 | — | — | ||
| Repair to the outdoor and indoor fan Motors including fixing as per the direction of engineer at site | — | — | — | 22,000 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of Sensor for Indoor and Outdoor Units of 16 Tr Capacity VRF Plants as per instruction of engineer at site. | — | — | — | 29,000 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of PCB for Indoor and Outdoor Units of 16 Tr Capacity VRF Plants as per instruction of engineer at site. | — | — | — | 64,000 | |
| — | 6.00 | — | — | ||
| Supply, fixing, connecting, testing & commissioning of Power Analyzer for monitoring frequency, voltage parameters of 3 phase 433V A/C local supply with output devise and that of DG set with other connected accessories etc., as per the instructions of Engineer in charge. Note: Approval of competent authority is to be obtained before the supply of material. | — | — | — | 3,60,000 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of Wireless, Print, Copy, Scan, Colour, Wi-Fi, Auto-Duplex, Refillable Ink Tank, Compact, borderless Printing of A4 size Papers with all connected accessories | — | — | — | 51,598 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of Wireless, Print, Copy, Scan, Colour, Wi-Fi, Auto-Duplex, Refillable Ink Tank, Compact, Borderless Printing of A3 size Papers with all connected accessories | — | — | — | 1,51,600 | |
| — | 3.00 | — | — | ||
| Design, supply, installation, testing and commissioning of cubicle type 14SWG LT panel (Outdoor type) with 400 amps sectionalized electrolytic copper bus bar (Copper bus bar should be uniform size RYBN). LT panel board should confirm to IS-8623 or latest. Advanced Multi function meters with CTs of suitable capacity with R.S.485 port for incoming supply with CTs of suitable and RYB LED indication lamps with all other connected accessories etc., as directed by Engineer at site. (1) 2 x 200/250 A 4pole 35/36KA Microprocessor based MCCB including suitable spreader links (I/C) Out goings: 6x125/160 Amps 4 pole, 35/36 KA Microprocessor based MCCB including suitable spreader links, 8x63A TPN 'C' curve 10KA MCB, 4x32A DP 'C' curve 10KA MCB. (2) Incoming for Generator supply 2x 200/250A 35/36KA Microprocessor based MCCB including suitable spreader links Note: 1) MCCBs: ICs=100% ICu, 2) MCCBs should be Microprocessor based only | — | — | — | 11,94,114 | |
| — | 3.00 | — | — | ||
| Design, supply, installation, testing and commissioning of cubicle type 14SWG LT panel (Outdoor type) with 200 amps sectionalized electrolytic copper bus bar (Copper bus bar should be uniform size RYBN). LT switchgear confirming to IS-8623 or latest. Advanced Multi function meters with CTs of suitable capacity with R.S.485 port for incoming supply with CTs of suitable and RYB LED indication lamps with all other connected accessories etc., as directed by Engineer at site. (1) 2 x 100/125 A 4pole 35/36KA microprocessor based MCCB including suitable spreader links (I/C), 1x100A change over switch Out goings: 6x40 Amps TPN MCB, 2x32A DP 'C' curve 10KA MCB, 6x16A SP MCB. Note: 1) MCCBs: ICs=100% ICu, 2) MCCBs should be Microprocessor based only | — | — | — | 3,63,135 | |
| — | 14.00 | — | — | ||
| Supply, fixing, connecting and commissioning of SDB double door 8 way TPN comprising of 1x63A MCB TPN, 6X32A MCB DP 10kA, with lock & key and neutral link arrangements as per direction of engineer at site. | — | — | — | 1,43,136 | |
| — | 8.00 | — | — | ||
| Supply, fixing, connecting and commissioning of SDB double door made up of 14 SWG sheet steel and comprising of 1x63A MCB DP change over switch, 3X32A MCB DP 10kA, with lock & key and neutral link arrangements as per direction of engineer at site. | — | — | — | 25,600 | |
| — | 24.00 | — | — | ||
| Supply of earth pit materials and construction of earth pit as per IS 3043:1987 specification. This item also includes of supply and erection of CI pipe of size of 100mm inner diameter, 13mm thickness and 3000mm length. This work also includes of fabrication and fixing of GI strips for earthing connection. Excavated earth pit should be filled by mixture of coke/charcoal, salt and sand up to top. Provision of brick masonry chamber of size 650mmx650mm and depth upto 1000mm including light type CI cover frame and applying 12mm thick cement plaster in 1:3 inside and to all the exposed faces up to 300mm below. Foundation level, curing etc., All required materials for this job such as CI pipe cover with frame, salt, cement sand, charcoal gravel, bricks etc. required bolts, nuts and double washers, number plates or painted plates. Tentative quantity of salt and charcoal shall be of 2.5CMt. The CI pipe should be painted with 2 coats of bitumen paint as per the directions of Rly engineer at site. Note: The work should be strictly done as per IS 3043:1987 specification or latest. | — | — | — | 2,08,800 | |
| — | 25.00 | — | — | ||
| Supply & erection of a maintenance free earthing with single rod as per RDSO specification No. RDSO/ PE/ SPEC/PS/0109-2008 Rev 0 or latest | — | — | — | 2,16,250 | |
| — | 250.00 | — | — | ||
| Supply, laying, connecting & commissioning of 50x6mm/ 40x5mm/ 25x 6mm thick GI Strip for earth pit as per the directions of engineer at site | — | — | — | 17,500 | |
| — | 250.00 | — | — | ||
| Supply & fixing of 9W down lighter with 9W LED as per the HQ specification the directions of engineer at site | — | — | — | 1,41,500 | |
| — | 81.00 | — | — | ||
| Supply of LED Downlighter (square & round) recess/surface mounting 18W | — | — | — | 93,879 | |
| — | 400.00 | — | — | ||
| Supply & fixing of 15W LED recess mounting down lighting round, greater than 180mm dia suitable to operate on 230v, 50Hz AC supply as per HQ specification and as per the directions of engineer at site. | — | — | — | 2,52,000 | |
| — | 90.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 35W LED Panel light fitting 2'x2' square type white with other connected accessories etc. | — | — | — | 2,45,700 | |
| — | 550.00 | — | — | ||
| Supply, fixing, connecting and commissioning of Profile LED light including all accessories size 32mm width, make similar to Philips | — | — | — | 4,57,600 | |
| — | 500.00 | — | — | ||
| Supply, fixing, connecting and commissioning of Profile LED light including all accessories size 17/18mm width, make similar to Philips. | — | — | — | 1,29,500 | |
| — | 51.00 | — | — | ||
| Supply, fixing, connecting and commissioning of 10A driver for profile LED light make similar to Philips | — | — | — | 61,200 | |
| — | 1000.00 | — | — | ||
| Supply, installation and commissioning of LED colour Rope light multi colour (warm white, white, green, saffron, pink, blue) as per the direction of site Engineer suitable to operate on 220V to 250V single phase AC supply as per directions of engineer at site | — | — | — | 1,49,000 | |
| — | 99.00 | — | — | ||
| Supply, installation and commissioning of Connectors for Rope light as per directions of engineer at site | — | — | — | 26,730 | |
| — | 5500.00 | — | — | ||
| Supply & laying of PVC conduit pipe of 25 mm dia 2 mm thick in concealed/surface as per the directions of Engineer at site | — | — | — | 1,70,500 | |
| — | 2300.00 | — | — | ||
| Supply & laying of PVC conduit pipe of 32 mm dia 2 mm thick in concealed/surface as per the directions of Engineer at site | — | — | — | 1,26,500 | |
| — | 200.00 | — | — | ||
| Supply & fixing of PVC conduit moulded bend pipe 32/25 mm dia 2 mm thick in concealed | — | — | — | 5,600 | |
| — | 150.00 | — | — | ||
| Supply & fixing of PVC Junction box of suitable way for 32/25 mm dia 2mm thick PVC conduit pipe in concealed | — | — | — | 3,750 | |
| — | 100.00 | — | — | ||
| Supply and laying of flexible 25mm PVC pipe | — | — | — | 1,800 | |
| — | 400.00 | — | — | ||
| Cutting and chipping the wall for laying the PVC conduit pipe and plastering after laying the PVC conduit pipe with cement and sand mortar mixed with 1:8 ratio, but without laying PVC conduit pipe. | — | — | — | 13,600 | |
| — | 26000.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core FRLS multi strand 1.5sq. mm Cu. Conductor | — | — | — | 4,42,000 | |
| — | 15500.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core FRLS multi strand 2.5sq. mm Cu. Conductor | — | — | — | 4,34,000 | |
| — | 10000.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core FRLS multi strand 4.0sq. mm Cu. Conductor | — | — | — | 4,40,000 | |
| — | 2500.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core FRLS multi strand 6.0sq. mm Cu. Conductor | — | — | — | 2,35,000 | |
| — | 1500.00 | — | — | ||
| Supply, laying, connecting & commissioning of single core FRLS multi strand 10.0sq. mm Cu. Conductor | — | — | — | 1,77,000 | |
| — | 800.00 | — | — | ||
| Supply, laying, connecting and commissioning of 4 core 6 mm sq.mm multi stranded FRLS cu. Conductor for AC as per the directions of Engineer at site | — | — | — | 3,16,800 | |
| — | 396.00 | — | — | ||
| Supply and erection of ceiling rose. | — | — | — | 15,840 | |
| — | 1486.00 | — | — | ||
| Supply & erection of 6/10A 1-way switch | — | — | — | 96,590 | |
| — | 240.00 | — | — | ||
| Supply & erection of 16/20A one way switch | — | — | — | 21,120 | |
| — | 400.00 | — | — | ||
| Supply & erection of 6/10A socket with safety shutter | — | — | — | 34,000 | |
| — | 240.00 | — | — | ||
| Supply & fixing of 16/20A socket heavy duty with safety shutter | — | — | — | 33,840 | |
| — | 12.00 | — | — | ||
| Supply & erection of 18 way module size GI sheet metal/PVC box concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 2,328 | |
| — | 12.00 | — | — | ||
| Supply & erection of 18 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 2,904 | |
| — | 120.00 | — | — | ||
| Supply & erection of 12 way module size GI sheet metal/PVC box concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 18,960 | |
| — | 120.00 | — | — | ||
| Supply & erection of 12 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 22,680 | |
| — | 120.00 | — | — | ||
| Supply & erection of 8 way module size GI sheet metal/PVC box in concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 14,640 | |
| — | 120.00 | — | — | ||
| Supply & erection of 8 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 18,360 | |
| — | 80.00 | — | — | ||
| Supply & erection of 6 way module size GI sheet metal/PVC box in concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 7,680 | |
| — | 80.00 | — | — | ||
| Supply & erection of 6 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 9,760 | |
| — | 40.00 | — | — | ||
| Supply & erection of 3 way module size GI sheet metal/PVC box in concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 2,440 | |
| — | 40.00 | — | — | ||
| Supply & erection of 3 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 3,080 | |
| — | 30.00 | — | — | ||
| Supply & erection of 2 way module size GI sheet metal/PVC box in concealed/surface similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 1,200 | |
| — | 30.00 | — | — | ||
| Supply & erection of 2 module size modular plates with unbreakable frame similar to GM make or equivalent as per the directions of Engineer at site | — | — | — | 1,380 | |
| — | 40.00 | — | — | ||
| Supply, laying and fixing of water proof PVC casing & caping of size 100x50 mm of 2 mtrs length each including all connected accessories etc. | — | — | — | 10,240 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing & commissioning of online UPS of 5.0 kVA capacity with indicative back up time of 90 minutes suitable for single phase AC input and single phase AC output including suitable battery stand as per the direction of engineer at site. | — | — | — | 3,93,426 | |
| — | 6.00 | — | — | ||
| Supply & fixing of chandelier light including all accessories as per the directions of engineer at site | — | — | — | 2,07,936 | |
| — | 15.00 | — | — | ||
| Provision of concrete foundation and constructing the plinth as per the directions of engineer at site. | — | — | — | 60,045 | |
| — | 10.00 | — | — | ||
| Supply of Temperature & Humidity Meter with accessories- model no, HTC HD304, HD 304 or equivalent. Specification document attached. Makes: HTC, RISHABH, FLUKE or equivalent.Note: Test, guarantee & warranty certificates to accompany at the time of supply. Note: one sample to be got approved by consignee before bulk supply. Accepted make: Beetech- MODEL:B-301 and as per the direction of Engineer at site | — | — | — | 18,040 | |
| — | 2.00 | — | — | ||
| Supply of EEPT Hand Pallet Truck with Load Capacity 3000 kilogram as per specification as per the direction of Engineer at site. | — | — | — | 16,580 | |
| — | 2.00 | — | — | ||
| Supply of Gas welding cutting kit Oxy Acetylene Oxygen torch brazing kits, Victor type with hose as per the direction of Engineer at site. | — | — | — | 72,782 | |
| — | 3.00 | — | — | ||
| Supply of Digital Flexible Clamp Meter with Bluetooth feature of Cat-IV 600 V and Cat- III 1000 V Safety rated for measuring 1000 V AC/DC Voltage, AC/DC Current Measurement upto 1000 A, PF Measurement, Watt Measurement, Phase Rotation Indication, Resistance, Continuity, Hormonic Distortion and frequency measurement capable of operating at 0 C to + 50 C; Updates at 3/Sec, with LCD Display with Backlight; Accuracy: AC Volts: + or - (1.5%+5 Digit), AC Current: + or - (1.5%+5 Digit); minimum of 3 year warranty, including Test Leads, Carrying Holster, Battery and calibration certificate and should be equivalent to model Meggar FCC3450 | — | — | — | 2,83,200 | |
| — | 5.00 | — | — | ||
| Supply of Power Drill Machine with core bit and long bit as per the direction of Engineer at site. | — | — | — | 47,200 | |
| — | 3.00 | — | — | ||
| Supply of Power Cutting Machine as per the direction of Engineer at site. | — | — | — | 12,390 | |
| — | 5.00 | — | — | ||
| Supply of Jet washers for cleaning & servicing of ACs as per the direction of Engineer at site. | — | — | — | 17,785 | |
| — | 15.00 | — | — | ||
| Supply of tool kit which includes 22 items (list of items is enclosed in the tender document) | — | — | — | 3,87,990 | |
| — | 2.00 | — | — | ||
| Supply of Portable R22 refrigerant gas cylinders of 2kgs capacity as per the direction of Engineer at site. | — | — | — | 5,476 | |
| — | 2.00 | — | — | ||
| Supply of Portable R32 refrigerant gas cylinders of 2kgs capacity as per the direction of Engineer at site. | — | — | — | 6,420 | |
| — | 2.00 | — | — | ||
| Supply of Portable R410 refrigerant gas cylinders of 2kgs capacity as per the direction of Engineer at site. | — | — | — | 6,608 | |
| — | 2.00 | — | — | ||
| Supply of Freon Leak detector refrigerant gas leakage tester of HVAC Air Condition as per the instruction of engineer at site | — | — | — | 6,000 | |
| — | 2.00 | — | — | ||
| Supply of MAPP Gas Propane Welding Torch Kit, Brass and Stainless Steel Cutting Torch Kit with Dual Pressure Gauge and Metal Case | — | — | — | 46,756 | |
| — | 20.00 | — | — | ||
| Existing Packaged plant removing and to be handed over to SSE/AC/HYB stores as per direction of engineer at site | — | — | — | 1,00,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender document
ATTACHMENT
ExperianceCertificate.pdf
ATTACHMENT
New GCC April 2022
ATTACHMENT
3toGCCApril.2022RBCE_CE-I-
ATTACHMENT
GCC-2022-
ATTACHMENT
GCCACS11dt.13.03.2026.pdf
ATTACHMENT
NEFTForm.pdf
ATTACHMENT
I_CT_GCC-
ATTACHMENT
GCC_April-2022_2022_New.pdf
ATTACHMENT
CorrectionSlip2022_CE-I_CT_GCC-2022Policy14.07.2022_1.pdf
ATTACHMENT
ACS-3toGCCApril.2022RBCE_CE-I-CT2023_04_26.pdf
ATTACHMENT
ACS-2toGCC-2022-CE-1-CT-GCC-2022-POLICY_13.12.2022.pdf
ATTACHMENT
ApprovedTB28-26-27KalaRN.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].