Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.4 LAccepted-AOC | ₹2.4 L | L-1 | Accepted-AOC AOC done |
| 2 | L-2₹2.4 LRejected-Finance | ₹2.4 L | L-2 | Rejected-Finance Not-responsive |
Tender Value
₹2.5 L
EMD Value
₹5,100
Closing Date
3 Feb 2026, 11:00 amClosed
Executive Engineer Electrical Division HPPWD. Una
Executive Engineer Electrical Division HPPWD. Una
.
2026_PWD_126556_1
NIT No. 8588-8613 dated 21/01/2026
Open Tender
Electrical Works
545 days
Una
Please refer Tender documents.
7 documents required · 7 mandatory
₹350
₹5,100
29 Apr 2026
23 Jan 2026
3 Feb 2026
23 Jan 2026
3 Feb 2026
23 Jan 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed Heavy class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Make :-Anchor (Urban ) /L&T(Englaze)/ Legrand(Lyncus) Make of wires :-KEI/ Finolex/ polycab make of conduit:- Diplast/ BEC/ AKG as approved by Engineer-In-Charge.
Group c
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Heavy class PVC conduit as required.Make:-KEI/ Finolex/ polycab as approved by Engineer-In-Charge.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.Make:-KEI/ Finolex / polycab as approved by Engineer-In-Charge.
3 x 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required Make :-Anchor (Urban )/ L&T(Englaze)/ Legrand(Lyncus) as approved by Engineer-In-Charge.
5/6 amp Modular switch
5 pin 5/6 amp socket outlet
Telephone socket outlet
computer jack (RJ-45) with shutter
USB Charger - 1500mA Type A
Voltage Surge Protector - 230V - 1 Module
Fan Regulator - 100 Watts - 360° - ISI - 2 Module
Supplying and fixing 2 module ,G.I box alongwith modular base & cover for modular switches in recess etc.as required. Make :-Anchor (Urban )/ L&T(Englaze)/ Legrand(Lyncus) as approved by Engineer-In-Charge.
Supplying and fixing Ding Dong bell suitable for single phase, 230 volts, complete as required.Make :-Anchor (Urban )/ L&T(Englaze)/ Legrand(Lyncus) as approved by Engineer-In-Charge.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. Make :-Anchor (Urban )/ L&T(Englaze)/ Legrand(Lyncus) as approved by Engineer-In-Charge.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. Make :-Anchor (Urban )/ L&T(Englaze)/ Legrand(Lyncus) as approved by Engineer-In-Charge.
Supplying & fixing suitable size GI box wih modular plate and cover in front onsurface or in recess i/c providing and fixing 25 amp modular socket outlet and 32 Amps modular SP MCB, “C” curve including connection, painting etc. as required. Make :-Anchor (Urban )/ L&T(Englaze)/ Legrand(Lyncus) as approved by Engineer-In-Charge.
Supplying and fixing computer point includes 9 module G.I box & modular plate and cover recess , including providng and fixing 3 nos. 3 pin 5/6 amps modular socket outlets and 3 nos 5/6 amps modular switches, connection etc. as required. Make :-Anchor (Urban )/ L&T(Englaze)/ Legrand(Lyncus) as approved by Engineer-In-Charge.
Supplying and fixing of following sizes of Heavy PVC class FRLS PVC Conduit having wall thickness minimum 2.0 mm along with accessories in surface/recess/including cutting the wall and making good as required make:- Diplast/ BEC/ AKG as approved by Engineer-In-Charge.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/ PVC conduit as required.Make:-Polycab/ D-link/ Finolex as approved by Engineer-In-Charge..
4 pair UTP CAT 6.
Supplying and fixing Loaded Wall- Wall Mount 4u ,Unloaded Mounting Rail with U-Marking welded Side walls !U Cable Manager (1) Hardware Packet (1Pkt)3 socket 5amp .power distribution Unit(1NO) . Make:- D-Link/ Cisco/ HP/ Netgear as approved by Engineer-In-Charge..
Providing and fixing of following type surface mounted Luminaire LED batten 25 watts ,having high Quality design aluminium extruded decorative end caps and it should be compatible with specification i.e. P.F >.9,THD<10% and luminius flux 3250 Lumens per watt 130,CRI> 80 suitable for input voltage: AC 220-240 V, 50/60Hz, Burning hours >50000@L70 complete with all accessories, connections, testing and commissioning etc as: Make:- Philips/ Panasonic / jaquar as approved by Engineer-in -charge.( Five year warranty)
Supplying and fixing surface round recess type LED 24 watt, 6500k,with clear glass cover with die cast aluminium housing and it should be compatible with specification i.e. Power Factor > .9, Harmonic Distortion<10% and efficacy 100 Lumens per watt,& luminous flux 2400 lm suitable for input voltage: AC 220-240 V, 50/60Hz, life span >50000 hrs @L70,SPD 4KV complete with all accessories, connections, testing and commissioning etc. Make:- Jaquar/ panasonic/ Philips/ wipro as approved by Engineer-In-Charge.
Providing and Fixing of LED fixture 600mmX600mm 36 Watt +/- 1W Surface mounted fixture with HET Plastic diffuser with minimum system lumen efficacy of 100 lm/W with CRCA housing having P.F.>0.95 with THD<10% ,CRI 80.The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 5700 K with CRI of minimum 80. The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. Make:- Philips /Wipro/ Jaquar as approved by Engineer-In-Charge..(five year warranty)
Supplying and fixing of DLP 105x50 mm PVC adaptable trunking on the exiting wall at required height from lower level for power connection, light connection and net working connection including partition chip complete in all respect as required . Make:-Legrand / MK as approved by Engineer-In-Charge..
Supplying and fixing of Flexible cover with width 85 mm for DLP 105x50 mm PVC adaptable trunking on the exiting wall complete in all respect as required . Make:-Legrand / MK as approved by Engineer-In-Charge..
Supplying and fixing of Int Angle Adj Frm 80 Deg for DLP 105x50 mm PVC adaptable trunking complete in all respect as required . Make:-Legrand /MK as approved by Engineer-In-Charge..
Supplying and fixing of Joint For 85 Width Cover for DLP 105x50 mm PVC adaptable trunking complete in all respect as required . Make:- Legrand / MK as approved by Engineer-In-Charge..
Supplying and fixing of base joint for DLP 105x50 mm PVC adaptable trunking complete in all respect as required .Make:-Legrand / MK as approved by Engineer-In-Charge.
Supplying and fixing of End cap for PVC adaptable trunking complete in all respect as required . Make:-Legrand / MK as approved by Engineer-In-Charge..
Supplying and fixing of 6 module Base & frame for PVC adaptable trunking complete in all respect as required .Make:-Legrand / MK as approved by Engineer-In-Charge.
Providing and fixing Water purifier includes 8 litre tank capacity, 10 stage purification RO+UV with two year site on warranty includes , filter, electrical part, & sapre parts etc complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. Make:-KENT RO/ URBAN/ AQUA/ V-GAURD as approved by Engineer-In-Charge..
Supplying and fixing 63 amp rating, double pole, 240 volts,10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete complete with connections, testing and commissioning etc. as required. Make:- L&T / legrand/ Hager /Schneider as approved by Engineer-in -charge.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, 10 ka residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:-L&T / legrand/ Hager / Schneider as approved by Engineer-in -charge.
63 Amp, double pole, (single phase and neutral)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:-L&T / legrand/ Hager / Schneider as approved by Engineer-in -charge.
Single pole.
Supplying and fixing MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator Make:-L&T / legrand/ Hager / Schneider as approved by Engineer-in -charge.
16 way Double Door
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.64 MB
SBD.pdf
Tender Documents • 4.25 MB
BOQ_186649.xls
BOQ • 0.30 MB
undertaking.pdf
Additional Documents • 0.38 MB
Download all tender documents and submit your bid