| 1 | 1₹3.3 CrAccepted-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹3.3 Cr Quoted ₹3.4 Cr | 1 | Accepted-AOC Being L1 and reasonable. |
| 2 | 2₹3.5 Cr+₹17.7 L (5.28%)Rejected-Finance 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | ₹3.5 Cr+₹17.7 L (5.28%) | 2 | Rejected-Finance Being other than L1 |
| 3 | 3₹3.8 Cr+₹46.0 L (13.7%)Rejected-Finance 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹3.8 Cr+₹46.0 L (13.7%) | 3 | Rejected-Finance Being other than L1 |
| 4 | 4₹3.9 Cr+₹52.3 L (15.6%)Rejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹3.9 Cr+₹52.3 L (15.6%) | 4 | Rejected-Finance Being other than L1 |
| 5 | 5₹4.0 Cr+₹62.4 L (18.6%)Rejected-Finance POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹4.0 Cr+₹62.4 L (18.6%) | 5 | Rejected-Finance Being other than L1 |
Tender Value
₹3.8 Cr
EMD Value
₹4.5 L
Closing Date
27 Jul 2023, 6:00 pmClosed
Chief Engineer
Headquarters Chief Engineer AN Zone Military Engineer Services Birchgunj Junglighat Post Port Blair 744 103
AUGUMENTATION OF POWER SUPPLY INFRASTRUCTURE WITH FITMENT OF AVRS FOR A, B, C, D and E JETTY AT NSRY (PBR).
2023_MES_601135_2
801225/E8
Open Tender
Electrical and Maintenance Works
Item Rate
450 days
Port Blair
As per NIT documents
8 documents required · 8 mandatory
₹2,000
GE HADDO
₹4.5 L
6 Sept 2023
3 Jul 2023
3 Aug 2023
3 Jul 2023
27 Jul 2023
10 Jul 2023
Amount
M&L for for lifting the RCC cover slab, approximate length (2m to 4.5m) x width (1m to 2m) and upto 300mm thick and about 3.0ton to 5.0ton in weight on IN Jetty as per site conditions by cutting/chipping the clearance groove all around, keeping aside using a crane for laying of LT/HT cables including cleaning of cable duct without disturbing the existing system including re-fixing the same slab at same location after carrying out repairs/laying of cables including making good the surfaces to match with existing including PCC, RCC etc. complete all as specified and as directed. Note: 02 Nos of cover slab shall be taken out/ removed as per site condition for laying of cables/earth strip in the cable duct of Jetty after for a span of 15 to 20 metres or as per site requirement.
M&L for lifting the RCC cover slab, 1.5m x 1m size (approx) and upto 100 mm thick and about 0.5ton to 1.0ton in weight on jetty cable duct as per site conditions by cutting/chipping the clearance groove all around, keeping aside using man power/crane for laying/removing of new LT cable and replacing at the same location after carrying out repairs including making good the surfaces to match with existing including PCC, RCC etc. complete all as specified and directed.
M&L for providing precast cement concrete M-20 type A1 1:1.5:3 , nominal size of graded course aggregate in 20mm, set in cement mortar 1:4 as in cover slab complete all as specified and as directed. Note: Design of the RCC cover slab shall be approved from the Accepting Officer before execution of work.
M&L of Mild steel TMT bar 10mm dia and cover, cut to length, bend to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Supply, installation, testing and commissioning of sandwich type copper bus bar trunking system LT Bus duct, 440 volt, 3 Phase, 4 wire non segregated sandwich type confiming to IEC 61439 of capacity 4000 Amps duly enclosed with 3mm thick CRCA sheet Steel, epoxy coated, CPRI approved, class F insulation (155 deg C) IP 54 protection including earthing copper bus bar of size 50% of the phase bus bar continuously run over the entire length complete all as specified and directed to connect between Transformer/ Auto Servo Voltage stabilizer and LT panel or LT Panel to LT Panel with structural steel supports complete all as specified and as directed. Note: Order of copper bus duct has to be made after complete finalization of erection plan of Automatic voltage stabilizer and LT panel at INS Jetty for seamless execution of work.
S&F Horizontal Elbow / Vertical Elbow for copper bus trunking system of 4000 Amps capacity (TPN). complete all as specified and as directed.
S&F Flanged end for copper bus trunking system of 4000 Amps capacity(TPN). complete all as specified and as directed.
S&F Adopter Box with Terminal Flanges for copper bus trunking system of 4000 Amps capacity(TPN). complete all as specified and as directed.
S&F Copper Flexibles for connecting of copper bus trunking system of 4000 Amps capacity to Transformers/AVRs to LT Panel (TPN). complete all as specified and directed.
S&F Copper short links for connecting of copper bus trunking system of 4000 Amps capacity to Transformers/AVRs to LT Panel (TPN). complete all as specified and as directed. Note for item No 5 to 10: (i) The No of runs of bus bars required to achive current carrying capacity of 4000 amps shall be designed confirming to relevant IS by the OEM and design details/ parameters/ drawings shall be got vetted by accepting Accepting officer before execution. (ii) Rate quoted (per running meter) shall be deemed to include the bus trunking system and all accessories for 4000 amps as per design. No additional cost will be paid for the variations in design.
Supply, installation, testing and commissioning of sandwich type copper bus bar trunking system LT Bus duct, 440 volt, 3 Phase, 4 wire non segregated sandwich type confiming to IEC 61439 of capacity 2000 Amps duly enclosed with 3mm thick CRCA sheet Steel, epoxy coated, CPRI approved, class F insulation (155 deg C) IP 54 protection including earthing copper bus bar of size 50% of the phase bus bar continuously run over the entire length complete all as specified and directed to connect between Transformer/ Auto Servo Voltage stabilizer and LT panel or LT Panel to LT Panel with structural steel supports complete all as specified and as directed. Note: Order of copper bus duct has to be made after complete finalization of erection plan of Automatic voltage stabilizer and LT panel for seamless execution of work.
S&F Horizontal Elbow / Vertical Elbow for copper bus trunking system of 2000 Amps capacity (TPN). complete all as specified and as directed.
S&F Flanged end for copper bus trunking system of 2000 Amps capacity(TPN). complete all as specified and as directed.
S&F Adopter Box with Terminal Flanges for copper bus trunking system of 2000 Amps capacity(TPN). complete all as specified and as directed.
S&F Copper Flexibles for connecting of copper bus trunking system of 2000 Amps capacity to AVRs/LT Panel (TPN). complete all as specified and as directed.
S&F Copper short links for connecting of copper bus trunking system of 2000 Amps capacity to AVRs/LT Panel (TPN). complete all as specified and as directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, for laying of pipes/cables/poles etc., and not exceeding 10Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each layer as in soil complete all as specified and as directed.
Removing excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 500.00 sqmm 3.5core laid in trenches / floors / ducts or fixed on wall with suitable clamps/ saddles or drawn through pipes etc. complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400.00 sqmm 3.5core laid in trenches / floors / ducts or fixed on wall with suitable clamps/ saddles or drawn through pipes etc. complete all as specified and as directed. Note for item no.20&21: Earth work will be measured and paid separately.
Supply and laying HDPE DWC pipe of size 120mm (OD) x 103mm (ID) along with connected accessories like couplers, bends, end caps etc. for LT/ HT cable protection complete all as specified and as directed.
Supply and fix cable jointing kit for 1100V grade LT UG cable for Straight through joint, cold shrink type complete with jointing material and accessories suitable for 3.5core XLPE, armoured, Al conductor cable of size 400 to 500sqmm. complete all as specified and as directed.
M&L for Earthing complete with GI plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal Ground Level connected to GI strip 32mmX6 mm as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 5 of SSR Part-I connected to main board/distribution board complete all as specified and as directed. Note No.1: The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC M-25 (design mix) cover 50mm thick reinforced with 8mm dia CTD bars @ 150mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. page No.347 of SSR Part-II. Note No.2: Earthing lead beyond 7.5 m will be measured and paid separately.
Supplying and laying 32mm x 6mm G.I strip for connecting machinery from earthing including connection / terminating with G.I. nut, bolt, spring, washers etc and necessary clamps to fix on Jetty/duct ccomplete all as specified and as directed.
Supply & lay GI Pipe 100mm medium grade in trench for road crossings/obstructions for cable protection complete all as specified and as directed.
Cutting the existing road surface/PCC/ foot path in width of 50cm for laying of HT/LT cables including excavation of trenches up to 60 cm depth , returning filling, removal of soil in any type of soil, including making good for disturbed surfaces with PCC 1:2:4 type B1 using 20mm graded stone aggregate, including necessary form work , watering etc. complete all as specified and as directed.
S&F for structural steel section support/staging/chamber cover along with breaking support clamps and back plate fabricated including nuts, bolts, welding and bending cold or hot drilling holes for bolts, in any shape or size as indicated complete all as specified and as directed.
Supplying and laying synthetic Rubber insulated mats 2.5mm thick for voltage 11kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. complete all as specified and as directed.
Supply install, testing and commissioning of factory made indoor type floor mounted / self standing cubical LT panel of required size with the general construction shall conform to IS – 8623 – 1977 (Part – I) CPRI approved/ type tested, vermin proof type made out of 3mm thick CRCA sheet 3 phase 4 wire system 415 V AC 50 cycle with 4000 Amps copper bus bars, to be fabricated vertically as units including breaking of existing PCC and making cable duct of 1m x 1m and required length including 6mm thick MS duct cover as per site requirement to facilitate all cables without disturbing existing system, provision for taking incoming main LT supply from top side and incoming DG supply from bottom side from bus trunks and outgoing to loads connection from bottom side by using angular iron frame for each unit panel fixing with nuts & bolts on ICMS channel (unit wise fabrication for dismantling unit wise and refixing unit wise with accessories for easy transportation and fixing and commission of LT panel) using 2mm thick MS sheet all over body front and back cover with hinges and locking arrangements, 2mm thick MS sheet for bus bar cover, panel, partitions and bottom cable entry covers duly painted with powder coated type enamel paint with control wiring to complete LT panel with 1.5 sqmm FRLS copper cable and 5 A Bakelite cut outs for meters, breaker control supply and indication lamps and with the following necessary bus bars/ ACBS and accessories complete all as specified and as directed.
(g) BUS COUPLER:- Air circuit breaker 4000 Amps with breaking capacity not less than 65kA, inbuilt temperature protection, 4 pole 440 Volt AC, 50Hz, Electrically drawn out type, Electrically charged microprocessor release, internal battery for trip units, individual fault diagonis, with overload and over temperature protection with microprocessor based tripping system against Short circuit, instantaneous and earth fault protection, Electrically operated draw out type, closing coil, shunt release and pre trip alarm and individual fault LED indications -01 No. (h) OUTGOING:- (i) Air circuit breaker 1600 Amps with breaking capacity not less than 50kA ,inbuilt temperature protection, 4 pole 440 Volt AC, 50Hz, Electrically drawn out type, Electrically charged microprocessor release, internal battery for trip units, individual fault diagonis, with overload and over temperature protection with microprocessor based tripping system against Short circuit, instantaneous and earth fault protection, Electrically operated draw out type, closing coil, shunt release and pre trip alarm and individual fault LED indications -04 Nos.
(ii) Air circuit breaker 1250 Amps with breaking capacity not less than 50kA ,inbuilt temperature protection, 4 pole 440 Volt AC, 50Hz, Electrically drawn out type, Electrically charged microprocessor release, internal battery for trip units, individual fault diagonis, with overload and over temperature protection with microprocessor based tripping system against Short circuit, instantaneous and earth fault protection, Electrically operated draw out type, closing coil, shunt release and pre trip alarm and individual fault LED indications -02 Nos. Note: (i) Rate quoted includes necessary grouting / chipping of concrete makes of Anchor fastners and making PCC foundation to fix the LT Panel and connecting of necessary LT cables with new end terminations as directed by the Engineer -in-charge. (ii) Civil work required for the foundation of LT panel as per the manfacturer recomendation shall be deemed to be included in the quoted rate.
Disconnecting and taking out old unserviceable/under rated LT UG cables of size 300 to 500Sqmm from cable duct/trench without disturbing existing services and the same will be the property of contractor and the amount will be reimbursed as per rate given in schedule of credit complete all as specified and as directed.
Disconnecting and taking out old serviceable LT UG cables from LT Panel/FPB of size 240 to 500Sqmm from cable duct / trench without disturbing existing services and re-connecting the same LT UG cable to another LT Panel/FPB complete all as specified and as directed.
Disconnecting and taking out old serviceable LT bus duct (Aluminium/ Copper) from Transformer/LT Panel/FPB of size 4000Amps from cable duct / trench without disturbing existing services and re-connecting the same LT bus duct to another Transformer/LT Panel/FPB with necessary modifications required at site complete all as specified and as directed.
Vardhman Airport Solutions Pvt Ltd
GEPS PROJECTS
Sant Construction Co.
BHARAT MULTITECH INDUSTRIES PVT LTD
Tropical Refrigeration
Bharat Udyog
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .