Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹20.4 L+₹3.0 L (17.0%)Rejected-Finance 2 MANORATH MAIMOLEM VASCO DA GAMA GOA 403802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹20.8 L+₹3.3 L (19.1%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹22.9 L+₹5.4 L (31.0%)Rejected-Finance | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹29.8 L+₹12.3 L (70.7%)Rejected-Finance | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
11 Dec 2019, 6:00 pmClosed
SH M V SANKAR CWE NAVY VASCO
CWE NAVY VASCO GOA 403802
MAINTENANCE OF AC PLANT MAG NO 7 MIG 29 MAG NO 3 MAG NO 6 MAG NO 1 AND 2 APRE 2 AT NAD UNDER GE GOMANTAK VASCO
2019_MES_293802_1
85196/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE GOMANTAK VASCO
₹56,000
Yes
22 Jan 2020
30 Oct 2019
13 Dec 2019
30 Oct 2019
11 Dec 2019
27 Nov 2019
Amount
M&L for cleaning of shell and tube water cooled condensers of the A/C plants of following capacities after dismantling the water lines and headers and cleaning with suitable wire brush and washing soda to remove the dirt and water scaling and refixing the water lines and headers including provision of new gaskets, in every 04 months etc complete all as specified and as directed.
(a) 15 TR to 30 TR capacity
(b) 50 TR capacity
(c) 94 TR capacity
Supply and fix in repairs ball / roller bearing for pumps and motors of following capacity including taking down old bearing and re installation at site including testing on completion all as specified and as directed.
(a) Upto 15 HP capacity
(b) 20 HP to 30 HP capacity
(c) 40 HP to 60 HP capacity
Supply and charging compressor oil Servo manufactured by Indian Oil Corporation or Equivalent approved make including flushing/cleaning of oil chamber etc complete all as specified and as directed.
Nitrogen testing for the any capacity of compressors including condensing unit and gas piping complete as per the manufacturer instructions all as specified and as directed. Note :- Nitrogen pressure should be held without any drop in pressure inside the unit continue for 24 hours.
Supply and filling Nitrogen Gas Cylinder of 61 Kg Each Cylinder complete all as specified and as directed.
Supply and filling Refrigerant gas R-407 of 61 Kg Each Cylinder for AC plant compressor all as specified and as directed.
Supply and filling Refrigerant gas R-22 of 61 Kg Each Cylinder for AC plant compressor all as specified and as directed.
M&L for servicing Monoblock pumps including dismantling and opening the pump, repair/replacement of defective impeller, replace the worn out bearing impeller, stuffing box, back plates, gland packing mechanical seal and rusted nut, bolts etc assembling property, greasing all movable parts, fixing in position, testing and commissioning all as specified and as directed for the following HP pumps.
(a) 3 HP to 5 HP Pump
(b) 7.5 HP to 10 HP Pump
(c) 15 HP to 20 HP pump
Supply and fixing in repair power assembly expansion valve for up 80TR AC plant at EHU / ERS Model SVE 42 all as specified and as directed. Make – SPORLAN or equivalent as per the existing.
Supply and fixing in repair MVPD for up to 80 TR capacity at old AC plant Model equivalent as per the existing.
Supply and fix of V-belt size C 2650/C-102 including taking down old belt all as specified and as directed.
All as per item No-11 here in before, but of size B-112 .
All as per item No-11 here in before, but of size B-82.
All as per item No-11 here in before, but of size B-78.
All as per item No-11 here in before, but of size B-88.
All as per item No-11 here in before, but of size B-108.
All as per item No-11 here in before, but of size B-110.
Realignment of compressor and motor of any capacity on existing foundation all as specified and as directed.
Supply and fixing of CI butterfly valves with matching flanges, gaskets, hardware duly insulated with preformed pipe section fabricated to shape and bonded with adhesive. removable cover is required valves in 26 swg aluminium sheet, cover should be divided in to portions quick release toggles shall be used for assembly of covers all as specified and as directed for the following size:
(a) 50 mm bore.
(b) 65 mm bore.
Supply and fix High pressure control switch as per existing make and type including taking down old switch all as specified and as directed.
Supply and fix oil pressure control switch as per existing make and type including taking down old switch all as specified and as directed.
Supply and fix low pressure control switch as per existing make and type including taking down old switch all as specified and as directed.
Supply and fix LP/HP cut out as per existing make and type ML-5 including taking down old cutout all as specified and as directed.
All as per item No – 23 here in before, but type ML-4.
All as per item No - 23 here in before, but type ML-3.
All as per item No - 23 here in before, but type ML-2.
All as per item No - 23 here in before, but type ML-1.5.
Supply and fixing power contact assembly complete as per existing type and make including taking down old contactor all as specified and as directed.
Supply and fixing overload relay range 9-15 amps as per existing make suitable for ML-1/ML-1.5 contactor all as specified and as directed.
Supply and fixing overload relay range 20-33 amps as per existing make suitable for ML-2/ML-3 contactor all as specified and as directed.
Supply and fixing overload relay range upto 7.5 amps as per existing make suitable for MNX contactor all as specified and as directed.
Supply and fixing electronic timer ST 100 (3 to 10 Sec) 240V or as per existing make including taking down of old one all as specified and as directed.
Supply and fixing electronic timer ST 100 ST 100 (3 to 30 Sec) 415 Volts AC 50 HZ as per existing make as GIC suitable to the existing panel board including taking down of old one all as specified and as directed.
Supply and fixing indicator lamp assembly complete LED type suitable for the existing system supply voltage for the existing system supply voltage 230V / 440 V AC including taking down old lamp assembly all as specified and as directed.
Supply and fixing in repair of MCCB 3 pole 415 volts AC, 100 Amps complete all as specified and as directed.
Supply and fixing in repair of MCCB 3 pole 415 volts AC, 125 Amps complete all as specified and as directed.
Dismantling the unserviceable electric motor any type or of any capacity and transporting to reputed workshop, taking out old and burnt winding wire and rewinding with super enamelled copper winding wire of existing gauge and size with insulating materials, varnishing and baking etc, re-fixing the same at site and re-alignment, testing and commissioning complete all as specified and as directed.
Taking out old and fix new PVC fins of cooling tower of any capacity AC plant and replacing with new one including setting complete all as specified and as directed. Make : Mihir or equivalent as approved by GE.
Supply and fixing in repair fabricated Hyphen filter upto 90 micron made out of GI channel frame overall size 55 cm x 55 cm x 5 cm including nylon micro filter and wire mesh covered front and back all as per sample given including taking down old micro filter all as specified and as directed.
Supply and fix in repair in repair DOL starter suitable for 5HP motor capacity 9 to 14 Amp complete with over load relay , single phasing preventer under volt release etc all as specified and as directed. Make : L&T or equivalent in Schneider/Havells.
Supply and fix in repair in repair DOL starter suitable for 10 HP motor capacity 14 to 23 Amp complete with over load relay, single phasing preventer under volt release etc all as specified and as directed. Make: L&T or equivalent in Schneider/Havells.
M&L for preparation of old painted surfaces by removing dust, rust etc and, applying two coats of synthetic enamel paint with spray gun of approved make and colour for cooling tower, condensing pipe line condenser water pumps including all pipe line valves etc. of 5 TR to 60 TR Capacity Plant all as specified and as directed.
Supply and fix CT fan (with hub and fan blade) of capacity 5 to10 HP for cooling tower all as specified and as directed.
S & F in repair chilled water sensor for AC Plants of any capacity all as specified and as directed.
S & F solenoid valve assembly complete for compressor of capacity upto 30 TR all as specified and as directed.
S & F solenoid valve assembly complete for compressor of capacity from 45 TR upto 94 TR all as specified and as directed.
S & F loading/unloading switch assembly for compressor of capacity upto 30 TR all as specified and as directed.
S & F loading/unloading switch assembly for compressor of capacity from 45 TR upto 60 TR all as specified and as directed.
S & F microprocessor for compressor of capacity upto 30 TR as per existing make/model all as specified and as directed.
S & F microprocessor for compressor of capacity from 45 TR to 60 TR as per existing make/model all as specified and as directed.
S & F cooling tower nozzles 1/4'' size of existing model all as specified and as directed.
S & F block bearing for air handling unit size 207 of existing model all as specified and as directed.
Dismantling the compressor and taking out the shaft from the compressing unit and taking to the reputed workshop for necessary lathe/ machining work to match the bearing size, cleaning inside the compressing unit and necessary overhauling complete all as specified and as directed.Installation of compressor and connect with motor, alignment and carrying out of testing to the entire satisfaction of Engineer-in-charge for 30 TR AC plant compressor. Note : Defective spares required to be replaced shall be measured and paid separately as "Supply only" under appropriate items of this schedule.
Supply only spare for 3x15 TR capacity compressor
(a) Main bearing for both ends
(b) Connecting rod bearing
(c) C R bush
(d) Pistons
(e) Pistons pin
(f) Piston ring set
(g) Piston circlips
(h) C R Nuts & bolts
(j) S V Reeds
(k) D V Reeds
(l) S V Springs
(m) D V Spring
(n) Suction filter dryer.
(o) Oil pump
(p) Linear o ring
(q) Gasket set
(r) Thrust washer
(s) Aluminium Gasket set
(t) Rocker arm with cup & washer
(u) Oil pressure regulating valve
(v) Rocker arm spring
(w) Suction and discharge valve O ring set
Supply and fix pressure relief valve as per existing make all as specified and as directed.
Supply and fix Cold room humidity sensor as per existing make all as specified and as directed.
Supply and fix Cold room strainer as per existing make all as specified and as directed.
Supply and fix solder tube union (with valve core & copper tube) as per existing make all as specified and as directed.
M&L for assembly and erection of GI sheet with TDF flange rectangular/square duct made out of L shaped hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete of size 22 gauge complete all as specified and as directed.
All as per item No 59 here in before, but 24 gauge complete all as specified and as directed.
M&L for providing acoustic lining to the ducting by using FG crown 200x25mm thick rigid board density 32kg/m3 covered with RP tissue & 28G aluminium perforated sheet & using GI nuts, bolts & washer for the entire duct complete all as specified and as directed.
M&L for thermal insulation of duct using adhesive & FG crown-150 factory laminated covered with aluminium foil of 50mm thickness complete all as specified and as directed.
Repair and maintenance of AC plant heater including internal wiring and replace of any part of internal body all as specified and as directed.
Supply and fix of Humidistat of AC plant up to 80 TR including all accessories complete all as specified and as directed.
Supply and fix hermatically sealed compressor for AC plant up to 50 TR capacity including all accessories complete all as specified and as directed.
Heat Control
Shine Enterprises
BRITE INDUSTRIES
M/S SUVIDHA ENGINEERS (PROJECT)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .