Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹20.8 L+₹56,716.50 (2.81%)Rejected-Finance G 124 FLAT NO 4 DILSHAD COLONY DELHI 110095 | SHAHDARA | DELHI | 110095 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹21.5 L+₹1.3 L (6.24%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹37,000
Closing Date
29 Sept 2020, 6:00 pmClosed
GE (AF) ADM AREA GWALIOR
AIR FORCE STN. MAHARAJPUR
SPECIAL REPAIR TO ROOF AND TRUSSES OF T 70 BUILDING AND WORK SERVICES FOR MISC B R AND TILING WORK IN OTM AREA AT AIR FORCE STATION MAHARAJPUR GWALIOR
2020_MES_360194_2
8945/E8
Open Tender
Civil Works
Item Rate
120 days
AIR FORCE STN. MAHARAJPUR
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE AF ADM AREA GWALIOR
₹37,000
Yes
9 Nov 2020
1 Sept 2020
1 Oct 2020
1 Sept 2020
29 Sept 2020
15 Sept 2020
1 Sept 2020 - 8 Sept 2020
Amount
Demolition of PCC in ground floor and pavings (including floor tiles) not exc 15 cm thickness below or above ground level including removal of debris etc to a distance n. exc 2.5KM complete all as specified and directed. complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Demolition of PCC of any description and in any position not otherwise described, including removing demolished material to a distance n exc 500M distance and depositing where as directed, complete all as directed.
M&L for PCC 1:2:4 mix, type B1 (using 20mm graded stone aggregate) as in lintels, roof, kerbs, mud stops rounded or chemfered on edges etc complete all as specified and directed.
M&L for non skid, joint free, coloured ceramic tiles 7-8mm thick (Square/Rectunglar), as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles laid with and including over 15mm thick screed bed in CM (1:6), area of each tile exc 0.11 Sqm but not exc 0.18 Sqm complete all as specified and directed.
M&L for premium quality, coloured, glazed ceramic tiles size 450x300x 6-7mm thick as on vertical surfaces as dado/ skirting etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, laid with and including over 10mm thick rendering in CM (1:3) all as specified and directed.
M&L for premium quality, coloured, glazed ceramic tiles size 300x600x 6-7mm thick as on vertical surfaces as dado/ skirting etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, laid with and including over 10mm thick rendering in CM (1:3) all as specified and directed.
M&L for 10mm thick Glazed Vitrified ceramic tiles, light shade (square/rectangular), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of 15mm thick in CM (1:4) for laying floor finishes, area of each tile not exceeding 0.36 Sqm complete all as specified and directed.
M&L for 10mm thick Glazed Vitrified ceramic tiles, light shade (square/rectangular), on vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering in CM (1:3) , area of each tile not exceeding 0.36 Sqm complete all as specified and directed.
M&L for coloured, glazed ceramic stone kraft/ digital tiles of size 450x300x 6-7mm thick as on vertical surfaces as dado/ skirting etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, laid with and including over 10mm thick rendering in CM (1:3) all as specified and directed.
M&L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like bedded over and including 15mm thick screed bed in CM (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
S&F drapery rod fancy type, coloured, powder coated, made out of 25mm dia aluminium pipe of colour and pattern as approved by GE including decorative brackets on both ends complete all as specified and directed. Make: Aerolux/ MEC/ Vista.
M&L for 50 mm PCC 1:2:4 mix, type B1 (using 20 mm graded stone agg) as in flooring, finished even and fair complete all as specified and directed.
M&L for 25 mm PCC 1:2:4 mix, type B0 (using 12.50 mm graded stone agg) as in flooring, finished even and fair complete all as specified and directed.
Taking down old damaged cement plaster in any description on brick or stone wall etc., incl hacking out joints for key scrubbing down with water etc. complete all as specified and directed.
Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in Cement Mortar 1:6, complete all as specified and directed.
All as per item No. 17 here in before but except bricks complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or on concrete surfaces in Cement Mortar 1:6 surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or on concrete surfaces in Cement Mortar 1:4 surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces on walls and apply two coats of oil emulsion distemper over and including a thin layer of wall care putty complete all as specified and directed.
M&L for preparation of newly plastered surfaces on walls and apply two coats of exterior emulsion paint over and including a thin layer of wall care putty complete all as specified and directed.
Dismantling of asbestos cement ( corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling of timber scantling 40 sqcm and over in section, in any position as in unframed work complete all as specified and as directed.
Dismantling framed trusses not exceeding 10 M span complete all as specified and directed.
M&L for mild steel work as in roof trusses (Framed), trussed purlins, crane gantries, rail and fastening and heavy bracket framing (Beam, Tee, Angle, Channel or flat sections) including distance pieces, cleats etc confirming to Fe-290 (Gde E-165) Quality A complete all as specified and directed.
M&L for Pre-painted galvalume alu. Zinc coating GI based semi corrugated steel sheet 0.50 mm thick (total coated thickness) of any colour having tensile strength 550 M pa minimum yield strength as in roof covering fixed using hot dip galvanized self drilling and self tapping screws neoprene and EPDM washers. (Note : minimum, yield strength 550 Mpa with hot dip alloy of 55% Aluminium, 43.5 %zinc, 1.5% Silicon and finished with resin coat on both surfaces)
M&L for Pre-painted galvalume alu. Zinc coating GI based plain steel sheet 0.50 mm thick (total coated thickness) of any colour having tensile strength 550 M pa minimum yield strength as in ridge fixed using hot dip galvanized self drilling and self tapping screws neoprene and EPDM washers. (Note : minimum, yield strength 550 Mpa with hot dip alloy of 55% Aluminium, 43.5 %zinc, 1.5% Silicon and finished with resin coat on both surfaces)
S&F rubber beading 40 mm strip fixed to bottom of door complete all as specified and directed.
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of area not exc 1.50 Sqm each complete all as specified and directed.
Taking down chowkhats or frames with shutters ( without taking off shutters from the frames) of area exc 1.50 Sqm but not exc 4.0 Sqm each complete all as specified and directed.
S&F second class hard wood (Sal) plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S&F 35mm thick factory made plain framed, panelled shutters (two panel) of IInd class hard wood rail and styles with lock rail and panel of 9 mm BWP commercial ply. The size of rail and style as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified.
S&F 35mm thick factory made second class hard wood glazed and skeltron door shutter open rebated and prepared to receive glass or gauge etc divided into square with plain chamfered or rounded, mitred and rebated sash bars any number complete all as specified and as directed. Note :- Size of member of shutters as specified in SSR Part-I (2009) section 8 clause 8.20 (a).
S&F butt hinge, medium weight, cold rolled and fixed of size 100 mm complete all as specified and directed.
S&F anodised aluminium barrel tower bolts of extruded section of size 150mm complete all as specified and directed.
S&F anodised aluminium handles cast type of size 150mm complete all as specified and directed.
S&F 150mm mild steel helical door springs for flyproof doors complete complete all as specified and directed.
S&F 140 mm door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed complete all as specified and directed.
S&F anodised aluminium sliding door bolt with hasp, staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of size 250mm complete all as specified and directed.
S&F galvanized mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanized wire staples etc. in wooden door / window, completed all as specified and directed.
M&L for PCC (1:3:6) type C1 (20 mm graded stone aggregate) as in cill, bed block, block for insertion of hold fast of door and window with and including formwork complete all as specified and directed.
M&L for preparations of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paints over and including a coat of red oxide primer all as specified and directed.
M&L for mild steel work as in small article such as hold fast etc complete all as specified and directed.
M&L for two coats of synthetic enamel paint over and including a coat of pink primer including preparation of new wood or wooden base surface over 10cm width or grith complete all as specified and directed.
S&F in repair HPSC pre-prime 4mm thick non asbestos fiber cement building board (E-classic) decorative finish fixed to aluminum or MS galvanised snap grid frame work with hold down clips in ceiling complete all as specified.
S&F in repair suspended false ceiling grid system of size 600 x 600 mm with main runner of size 32 x 24 x 0.8 mm, cross tee of size 26 x 24x 0.80 mm and wall angle of size 22.2 x 22.2 x 0.65 mm in ceiling suspended @ 1.2m c/c both way with 1.60 mm dia GI wire fixed with steel dash fasterers or from purlin of roof with butterfly clips hold down etc, complete (main runner/ cross tee / wall angle of MS powder coated) as per manufacturere instruction complete all as specified.
S&F including fabricating of aluminium powder coated having minimum thickness of powder coating 50 micron for window/ ventilator frame, shutters including necessary joining cleats, glazing clips, aluminium snap beading having minimum wt 100gm/RM, rubber neoprene gasket, screws, dash fasteners, rawel plug for fixing of screw in wall or floor etc., aluminium sections as approved by GE including aluminium powder coated fittings such as per requirement complete all as specified and directed. Notes : - (i) Only weight of aluminium section shall be measured and paid. No claim what so ever shall be entertained by the Govt on this account. (ii) Thickness of section shall not be more than 2mm.
S&F for aluminium grills of size exc 5mm x 7.5mm and aperture n. exc 80mm incl fixing with aluminium hannel 1mm thick with steel screw and tint match with existing complete all as specified.
M&L for complete removal of existing treatment from old surfaces of wall including cornices and applying one thin layer of wall care putty to obtain desired/ true surfaces of wall complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper on prepared surfaces complete all as specified and directed.
M&L for applying two coats of exterior emulsion paint on prepared surfaces complete all as specified and directed.
S&F 4.00 mm thick sheet glass ordinary quality fixed to aluminium frame work complete all as specified and directed.
M&L for cutting chases in brick wall, pinning in and making good in cement mortar (1:3) to match with existing surface of girth not exc 10 CM complete all as specified and as directed :-
Taking down carefully existing unserviceable aluminum point wiring of any description & in any position with and including pvc/steel conduit all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings call bell, lamp holders etc and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as directed. NOTE: Old fittings/fixtures/accessories like switch, sockets, lamp holders, regulators etc found in serviceable condition shall be removed carefully for reuse in the work and shall be paid for separately under appropriate item of Schedule `A’.
Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor cable FR, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size not less then 20mm dia all as directed with using new sunken type pressed steel box/terminal boxes of suitable size, 2mm thick duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor cable FR single core. PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
NOTE: (i) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing colour of surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs and provision of 8covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick laminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of BOQ (Make of Cable/wire:- : Havells /Finolex/Polycab Make of PVC Conduit:-Finolex/Ess Ess Kay Engineering, Make of Laminated Sheet:-/Hylam/National)
All as per item No 56 hereinbefore but point wiring for 5 pin switch socket outlet combination, 5/6 Amps on independent board.
All as per item No 56 hereinbefore but point wiring for one 5 pin socket outlet, on same board .
All as per item No 56 hereinbefore but point wiring for one six pin socket outlet, 16/6 Amps (independent board) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor.
M & L for switch flush type single pole one way 5/6 Amps, 240 volts, white ivory finish complete all as specified. (Make :- Anchor(Panta)/ Cona/ Leader)
M&L for socket outlet 2 in 1, 5 pin, 6 Amps 240 Volts flush type white ivory finish complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
S&F for switch socket combination multi purpose, 5 Pin 6 amps 240 Volts, flush type with Indicator complete all as specified and directed.Make:-Cat part No 2216 of cona or equivalent of Leader/ Anchor(Panta).
S&F for switch socket combination multi purpose, 6 Pin 6/16 amps, 240 Volts flush type with Indicator complete all as specified and directed. Make:-Cat part No 2711 of cona or equivalent of Leader/ Anchor(Panta).
M&L for ceiling rose surface Bakelite three terminal, 18 x 50 mm complete all as specified. (Make :- Anchor(Panta) , Cona , Leader)
S&F for step type electronic fan regulator single phase ,230 volt, 100/120 watt . Complete all as specified. (Size of PT switch ) Make:-Cat part No 3211 of cona or equivalent of Leader/ Anchor(Panta).
Supply & Fix for decorative slim linear LED tube light fitting 01x20 watt light with co extruded polycarbonate body, environmental frendly, energy efficient ready to use pack with all accessories including 01 No 20 watt tube rod and connecting the same to ceiling rose with using copper conductor 24/0.20 flexible PVC sheathsd and fixing arrangement for fixing the light fitting to wall/ roof surface complete all as specified. (Make-Havell's Cat Part No LUMILINEBS20WLED865SPCWH/Surya Cat No -SLEBT -20 /CG cat No -LCTL 18 CDL)
S&F for LED bulk head fitting 10 watt energy saving new generation IP 65 luminatre with opel diffuser complete with lamp all as specified. (Make-Havell's Cat Part No-HEXAFT10WLED857SSYMBOPC/Surya cat Part No -SLE BH-10/ CG Cart Part No -LBHP-10 CDL)
S& F for Street light fittings 1x15watt new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light source with acrylic cover suitable for pole dia O 40mm(Max) with complete (40 mm GI pipe light grade ),clamp,nut-bolt and washer. Complete all as specified. ( Make : Havells Cat part No - ENDURAPEARLSL15WLED757SASYTOPC /Surya Cat Part No -SLRUL 15W IP 66LXN/CG cart part No -LSTS-15CDL.)
Dismaintling & Taking out MCB DBs any size , any type and capacity and remove materials from site of works. Complete all as directed.
S&F for sheet metal enclosure Double door for DB’s 8 way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires. Complete all as specified. (Make;ABB,Schneider,Legrand)
S&F for sheet metal enclosureDouble door for DB’s 4 way 415 volts, triple pole and neutral supply complete, fixed properly on MS strips and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires complete all as specified. (Make;.ABB/Schneider/Legrand)
S&F for MCB single pole 6 to 32 Amps, "C" Curve ,240 Volts complete all as specified (Make:Legrand/ABB/Schneider )
S&F for MCB Single pole and neutral 40 Amps 10 KA, 'C' series, 240 Volts complete all as specified. (Make:Legrand/ABB/Schneider )
S&F for MCB TPN 63 Amps, 10 KA, 240 Volts complete all as specified. (Make:Legrand/ABB/Schneider)
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 10.0 Sqmm of voltage rating upto and including 1100 Volts grade in and including conceled PVC conduit, med grade of size not less then 25 mm bore along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor cable FR all as specified and directed including taking down old submain wiring with any type of conduit. Complete all as specified. (NOTE : Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.) incl taking out old sub main wiring with any type of conduit.
Taking down carefully ceiling fan/exhaust fan including electric connection complete from site and re-fixing the same in existing position after civil work with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Taking down carefully Water heater (Geyser,s) any capicity any size and disconnecting all electric conection including hot & cold PVC water connection and refixing the same and connecting electric & water connection after the civil work. Complete all as directed.
M&L for earthing complete with MS Galvanised earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level including necessary excavation, earth work ,charcoal, salt etc and connected to GI earthing lead wire 4 mm dia by means of GI bolt nuts check nuts washers etc and 20 mm dia GI light grade watering pipe with funnel, wire mesh etc including PCC (1:3:6) type C-1 using 20 mm graded stone aggregate earth pit with 40x40x6 mm mild steel angle iron frame, RCC cover (1:2:4) type B-0, 50 mm thick reinforced with 8 mm dia round bar @100 mm centre to centre both ways with mild steel handle 12 mm dia, plastering 12 mm thick in cement mortar (1:6) internally and upto 150 mm below ground level externally, and GI earth lead wire 4 mm dia and 15 mm dia GI protection pipe medium grade from earth plate to test point upto 7.5m length all as shown in electrical plate No 3 of SSR Part -I 2009 and connected to earth test point including testing complete all as specified & directed.
Sunil Traders
SHRI RAM CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .