Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC NO 7 VANIDASAN STREET KOSAPALAYAM PUDUCHERRY 605013 | PONDICHERRY | PUDUCHERRY | 605013 | ₹10.4 L | L1 | Accepted-AOC Lowest rate |
| 2 | L2₹12.4 L+₹2.1 L (19.8%)Rejected-Finance NO 1055 MAIN ROAD ODIAMPET VILLIANUR PUDUCHERRY 605110 | CUDDALORE | TAMIL NADU | 605110 | ₹12.4 L+₹2.1 L (19.8%) | L2 | Rejected-Finance L2 |
Tender Value
₹14.6 L
EMD Value
₹29,192
Closing Date
28 Nov 2022, 4:00 pmClosed
The Executive Engineer, BRC, PWD., Puducherry
Assistant Engineer (Planning) Office of the Executive Engineer, BRC, PWD., Puducherry
Supply installation and commissioning of hot dip galvanized octagonal street light poles with LED street light fixtures in Abdul Kalam Nagar quarters Puducherry
2022_PWDC1_11409_1
27/BRC/2022
Open Tender
Electrical Works
Item Rate
60 days
Puducherry
Please refer tender documents
3 documents required · 3 mandatory
₹525
₹29,192
29 Dec 2022
21 Nov 2022
29 Nov 2022
21 Nov 2022
28 Nov 2022
21 Nov 2022
Amount
Supply of 7M high Hot Dip Galvanished Octagonal Pole with bottom 130mm A/F,top 70mm A/F made up of 3mm thick.HT sheet steel plate along width 200 x 200 x12mm base plate and having 1000mm long single arm bracket made up of 48mm dia,Bakellite sheet with single pole MCB & stud terminals (for mounting inside the base compartment of pole),Supple of 4 nos.M20 X 700mm long 'J' type foundation bolts(EN8 grade).(Make:Bajaj/Orient)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size) - Using Cement SRPC
Supply and fixing of Led out door flood light fitting in Highmast/Minimast having 140watts to 60watts (System Wattage). IP65/66 white colour with necessary over voltage, under voltage and surge protection with three years onsite warranty for replacement/Rectification. Make:Philips/Havells/Crompton/Bajaj/LED GEO.(The rate is inclusive of all taxes)
Fixing testing and commissioning of Sodiumvapour/Mercury vapour/Metal halide street light fittings on existing poles as required.
Supply of 2.5 sqmm x 3 core PVC sheathed multicore fexible copper cable. Make:Finolex/polycab/powerflex/havells(inclusive of GST).
Supply of ISI marked 4 x 16 sqmm armoured aluminium PVC U.G.cable-1.1KV grade. Make:Finolex/Polycab/havells (Inclusive of GST)
Supply of ISI marked 4 x 25 sqmm armoured aluminium PVC U.G.cable-1.1KV grade Make:Finolex/Polycab/Havells(Inclusive of GST)
Laying of one number PVC insulated and PVCsheahed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation, sand cushioning,protective covering and refilling the trench etc as required upto 35sqmm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade asrequired:4 X 16 Sq.mm(28mm).
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade asrequired:4 X 25 Sq.mm(28mm
Making earth pit of G.I. pipe for earthing in earth pit with 40mm dia. G.I. pipe medium class of length 3.05m perforated with 46 Nos of 12mm dia. holes, pipe lowered in bore holes of 150mm dia. and filled in with charcoal and salt in alternative layer of 300mm, the top of G.I. pipe shall be clamped. Earth pit shall be provided with 60cm dia precast ring with 60cm depth alround,covered with R.C.C. precast slab etc. as per I.E.standards.
Supplying and fixing of copper wire 8 SWG (4 mm dia) for earthing arrangements including bolt and nuts etc., complete.
Supply of 40mm dia - G.I. pipe (medium) - IS-1239 (TATA,TNT,NEZONE, APOLLO, ZENITH)
Supply, erection, testing and commissioning of one no of SMC Box(Make:Sintex) with metering and timer panel board for the power supply of over all size 850mm X 350mm X 250mm made out of glass wool with resig material.The front side top portion have energy meter with viewing glass with 10mm hylem sheet. The bottom side cpmpartments with 40-63A rating, TPN MCB,"C series, 10KA breaking capacity(Make:Simens/ABB),1no. of Timer switch(daily) along with battery backup to 200hrs.(Make:-L&T-Hagger/Legrand-Lexic),1no.60A power contactor(Make-C&S/L&T), 1no. of toggle switch(Make- C&S) The switch units are to be fixed with in the allotted size in the 10mm hylem sheet.The bottom sheet of the shell should be of PVC thick roll sheet for cable entry. The panel has to be mounted 75mm x75mm x6mm MS'L angle on the floor with in the height of 600mm. Interior connection between the switch fuse units are to be done with 2.5/6.0/10.0sqmm ISI marked,FR PVC insulated, single core copper conductor cable.(make:Finolex/Polycab). The door should be flush type interlocking in one position. The panel provided with removable type gland plated to the bottom and with sufficient holes of required diameter. Earth work excavation of foundation trench of size 1.00mx0.60mx0.60m and filling river sand for a depth of 00.10m and P.C.C. of 1:2:4(1 cement: two course sand: 4 graded stone aggregate of 20mm normal size) of size 1.00mx0.60mx1.00m. The cost should be inclusive ofminor modification suitable for site condition as approved by the engineer-in-charge.
Supply and fixing of 32/63/100/200A HRC fuse base.(The rate includes all taxes)
Supply and fixing of 32-100A HRC fuselink.(The rate includes all taxes)
Rajavel Electro Mechanical Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .