| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹10.1 L+₹46,631.60 (4.86%)Rejected-Finance OPP AIR FORCE STATION VPO SORANA DISTT SAHARANPUR UP PIN 247 232 | SAHARANPUR | UTTAR PRADESH | 247232 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹10.5 L+₹90,746.60 (9.46%)Rejected-Finance FLAT NO A 402 SHANKAR HEIGHTS NEAR CHETANA SCHOOL HAJI MALANG ROAD KALYAN EAST THANE MUMBAI 421 306 | THANE | MAHARASHTRA | 421306 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹10.6 L+₹1.1 L (11.0%)Rejected-Finance | L4 | Rejected-Finance Being 4rth Lowest | |
| 5 | L5₹11.0 L+₹1.4 L (14.7%)Rejected-Finance | L5 | Rejected-Finance being 5th lowest |
Tender Value
₹16.5 L
EMD Value
₹33,000
Closing Date
5 Sept 2020, 6:00 pmClosed
SHRI B K SREEKUMAR EE GE (AF) SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
PROVISION OF STREET LIGHTS IN VARIOUS LOCATION AT AF STN SARSAWA
2020_MES_367254_1
8120/SAR-23/E8 PROVISION OF STREET LIGHTS IN VARIO
Open Tender
Civil Works
Item Rate
273 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) SARSAWA
₹33,000
Yes
16 Sept 2020
7 Aug 2020
7 Sept 2020
7 Aug 2020
5 Sept 2020
22 Aug 2020
7 Aug 2020 - 22 Aug 2020
Amount
Supply and fixing 45 watt LED security light fitting with not less than 100 lumen/watt delivered lumen efficacy supported with LM-79/80, cast alluminium alloy housing IP 66 protection, input voltage range 120-270 volts auto cut off at voltage exceeding 300 volts, autopower on after cutt off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 5 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85% at constant current delivery, with secondary optic lense for every LED, with name of manufacturer / logo clearly embossed on housing of every fitting, LED CCT 5700+300 ANSI BIN, including taking down existing light fittings complete all as directed and specified.
Supply and fixing 60 watt LED security light fitting with not less than 100 lumen/watt delivered lumen efficacy supported with LM-79/80, cast alluminium alloy housing IP 66 protection, input voltage range 120-270 volts auto cut off at voltage exceeding 300 volts, autopower on after cutt off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 5 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85% at constant current delivery, with secondary optic lense for every LED, with name of manufacturer / logo clearly embossed on housing of every fitting, LED CCT 5700+300 ANSI BIN, including taking down existing light fittings complete all as directed and specified.
Supply and fixing 120 watt LED Flood Light fitting with not less than 100 lumen / watt delivered lumen efficacy supported with LM-79/80, cast aluminium alloy housing IP 66 protection, input voltage range 120-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, surge protection 5 KV internal and 10 KV external, driver current not exceeding 700 mA, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, LED CCT 5700 + 300 ANSI BIN, having PVC FRSR insulated copper cable of 3x2.5 Sqmm including taking down existing light fittings all as specified and directed. Notes for Ser No 1 to 03(i) Minimum one light fitting from each & every lot of supply be tested on above parameters from NABL accredited and Govt. approved independent lab. (ii) GE may also order for carrying out testing for certain more light fitting if he requires essential.
S & F in replacement of timer switch in suitable sheet metal metal encloure for security light made out of 1.6 mm thick MS sheet duly powder coated with locking arrangement. Fixed to wall/pole by means of clamp, nut, bolt and washers etc incl for comprising the following items :- (a) MCCB 63 A 25 KA 4 pole - 01 No Make :L&T/Schinder (b) MCB SPN 5 - 30 Amp - 01 No . Make : L&T/Strandard (c) Space for Power contactor ML-3 3 pole- 01 No . Make : L&T (d) Space for Timer switch -01 No. Make : L&T/Legrand (e) By pass arrangement for testing/repairing the lights
S&F in replacement Non metallic Junction box made out of PVC size not less than 28 cm x17cmx10cm hinged with lockable arrangement including aluminium bus bar TPN capacity 200 Amp with one No MCB 6 Amp SP with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole/grouting in PCC muff complete all as specified and directed.
S & F in replacement GI pipe 40 mm bore light grade for protection of cable /on wall/underground/road/on pole/flour all as specified & directed.
S&F Wiring for circuit/submain wiring 2x4Sqmm + 1x2.5 Sqmm FRLS PVC insulated copper conductor single core cable in concealed steel conduit of size not less than 20mm dia complete all as specified and directed.
Supply, transporting to site, errecting and fixing in position 9 metre long, Steel tubular swaged poles complete with cast iron/mild steel base plate, finial taper plug, bolts, nuts washers & screws as specified, type 410, SP-31 IS 2713 marked, drilling of necessary hole including painting to steel tubular poles, with two coats of aluminium paint over a coat of red oxide primer on exposed surface of poles and with black bituminous paint on portion of pole embedded in concrete and painting 3 Nos bands/strips with fluorescent PO red synthetic enamel paint 30 cms wide strip at 30 cms spacing from plinth block and numbering of poles complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in any type of soil, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cable complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 centimeter thick after laying and testing of cable complete all as specified and directed.
Removing excavated material not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning with layer of dry, clean & fine sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and as directed by Engr-in-Charge.
Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as on top all as specified and directed by Engineer-in-charge.
M&L, PCC 1:3:6 type C-1 using 20mm graded stone aggregate as coping to poles, filling and mass concrete complete all as specified and directed.
M&L, PCC 1:4:8 type D-2 using 40mm graded stone aggregate as coping to poles, filling and mass concrete complete all as specified and directed.
S&F in replacement cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending (cold or hot) drilling holes for bolts bent to any shape or size as indicated or directed inclusive of one primer coat of red oxide zinc chromate one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
M&L for point wiring with 1.5sqmm, FRLS PVC insulated, unsheathed, multistranded single core copper conductor cable with ISI marked for working voltage 1100 volt grade, drawn in and including PVC conduit medium grade not less than 20 mm dia ISI marked with necessary fixing acessories on surface of wall/roof etc. including 2.5 sqmm , FRLS PVC insulated multistranded copper conductor of ISI standard as earth continuity conductor and connecting to earth dolly and to be terminated in and inclusive of 1.6mm thick sutable size MS box and laminated hylum sheet of 3mm thickness ISI marked for mounting switches, socket out lets, regulatore etc. (a) One light/fan point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
Supply & fixing switch piano, flush type single pole, one way 15 Amp complete all as directed.
Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as directed.
S&F floor mounted moveble LED beam light (Serch Light) 150 Watt along with stand of length 5 feet with necessary connection comlete all as specifed and directed.
S&F MCB SP 6 Amps with breaking capacity 10KA complete all as specified and directed by Engineer-in-Charge.
S&F aheet metal enclosure distribution board one way single pole without bus bar complete all as directed.
S&F PVC flat twin core aluminium canductor of size 2.5 Sqmm complete all as directed.
SUBHASH CHAND CONTRACTOR
Gupta Enterprises
NAQLI LAL SHARMA AND ARUN SHARMA
Baliyan Electrical Works
Balraj and Co
ACESOLARR RENEWABLE ENERGY LLP
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .