| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-Finance 24A RABINDRA SARANI KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-Finance L1 | |
| 2 | L2₹10.3 L+₹1,120 (0.11%)Rejected-Finance BELTALA ALIPURDUAR | ALIPURDUAR | COOCH BEHAR | WEST BENGAL | L2 | Rejected-Finance L2 | |
| 3 | L3₹12.6 L+₹2.3 L (21.8%)Rejected-Finance 1087 LASKARHAT H 8A NASKARHAT TAGORE PARK KOLKATA KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L3 | Rejected-Finance L3 | |
| 4 | L4₹13.0 L+₹2.7 L (25.8%)Rejected-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹25,500
Closing Date
22 Feb 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, CED, COB, SUNITY ROAD
Executive Engineer PWD Cooch Behar Electrical Division
WBPWD/EE/CED/e-NIQ16/20-21
2021_WBPWD_324508_1
WBPWD/ee/CED/e-NIQ-16/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
120 days
ALIPURDUAR
Please refer tender documents
5 documents required · 5 mandatory
₹25,500
Yes
26 Feb 2021
8 Feb 2021
24 Feb 2021
8 Feb 2021
22 Feb 2021
8 Feb 2021
30 days
Amount
Dismantling the existing Fl. Fittings, wirings etc.by Co's own tools and Tackles.
Supplying and fixing 415V, 100A TPN SFU (Make-Siemens / L&T) with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
Supplying and fixing 100A sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc incl. powder coated painting
S & Laying 4x35 sq. mm. PVC/A, Al. Cable (Brand -Havells / Polycab / Gloster / KEI) on wall/surface as per G.S.
S & Laying 4x35 sq. mm. PVC/A, Al. Cable ( Brand -Havells / Polycab / Gloster / KEI) in U.G. Trench as per G.S.
S & F Compression type Cable gland and finishing the end of 4X35 sq. mm. PVC/A cable.
Supplying & fixing 40mm dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Supplying & fixing 415 V,4-way 16-32A per way, TPN MCB-DB with SS enclosure double-door with IP-42/43 protection with 63A, 4 pole isolators as incomer and 12 Nos. 16-32A SPMCBs ('C' curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand / Schneider / Crabtree)
Supplying & fixing 250 V , 2+10 way, 6-10A per way, SPN MCBDB with SS enclosure double-door with IP-42/43 protection with 40A DP isolator as incomer and 10 Nos. 10-16A SPMCBS ('C' curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make- Legrand / Crabtree / Seimens)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand -LEGRAND-ARTEOR / SCHNEIDER-ZENCELO / CRABTREE- MURANO), with 2 Module GI Modular type switch board with top cover plate incl. Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand -LEGRAND-ARTEOR / SCHNEIDER-ZENCELO / CRABTREE- MURANO) flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, Modular type starter (Brand-LEGRAND-ARTEOR/SCHNEIDER-ZENCELO / CRABTREE- MURANO) with 25A Modular switch type DP MCB (C- Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand -ANCHOR, PENTA) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
S & Laying 2X6 sq. mm. PVC/A, Al. Cable ( Brand -Havells / Polycab / Gloster / KEI) on wall/surface as per G.S. ( From PBDB at BMOH Office to SPNDB at PHN Office)
S & Laying 2X6 sq. mm. PVC/A, Al. Cable ( Brand -Havells / Polycab / Gloster / KEI) in U.G. Trench as per G.S. ( From PBDB at BMOH Office to SPNDB at PHN Office)
S & F Compression type Cable gland and finishing the end of 2X6 Sq. mm. PVC/A cable.
Supplying and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire (Brand -Havells / Polycab / Finolex / KEI) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
(i) 2X2.5 + 1X1.5 sq. mm. PVC copper wire. ( From SPNBDB to Computer Plug & Power Plug)
(ii) 2X6 + 1X4 sq. mm. PVC copper wire. ( From MCBPBDB to SPNBDB)
(iii)2X4 + 1X2.5 sq. mm. PVC Copper Wire. ( From PBDB to AC M/C Starter)
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish ware and mending good damages to original finish by using own tools and tackles
Finishing the end of following size PVC Copper Wire.
S & F 230V, 50Hz, 56" Sweep A.C. Ceiling Fan Complete with all accessories. ( Make- ORIENT-Summercool /ORIENT-NEWBREEZE / Crompton - Aura - Metallic)
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting.
Supply & Fixing Socket type fan regulator (Step type) (Brand ANCHOR) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
S&F 250V, 12" , 1420RPM , 80Watt sweep A.C. heavy duty Exhaust Fan ( Make -EPC Electrical Private Ltd) after cutting hole in wall incl. S&F louver shutter as per G.S.
S & F 240V,AC/DC superior type call bell ( ANCHOR) as per G.S.
Supply & Fixing Single LED light fitting (Make- PHILIPS, Cat No.-TMC501 P 1xT-LED 22W P3241 / OSRAM / WIPRO) with 1X18W LED tube ( Make- Philips, Cat. No- Mas LEDtube 1200mm 18W865 T8 I – 2100lm / OSRAM / WIPRO) complete with all accessories suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “U” type MS clamp and connecting the length of PVC insulated copper wire as per GS.
Supply & Fixing Twin LED light fitting (Make- PHILIPS, Cat No.-TMC501 P 2xT-LED 22W P3242 / OSRAM / WIPRO) with 2X18W LED tube ( Make- Philips, Cat. No- Mas LEDtube 1200mm 18W865 T8 I – 2100lm / OSRAM / WIPRO) complete with all accessories suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “U” type MS clamp and connecting the length of PVC insulated copper wire as per GS.
Earthing with 50 mm dia GI pipe (ISI-M) 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level.
Excavation of soft soil for installation of Earth Electrode and filling & ramming.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Brand -Havells / Polycab / Finolex / KEI) partly in 20mm size PVC rigid conduit 'FR' HMS / MMS type with same make of fittings e.g. Tee / bend / L joints / saddle etc [Make Precision / Polycab ] [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch (ANCHOR) fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] ( Av. Run- 10 Mtr.)
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed single core stranded copper wire (Brand-Havells / Polycab / Finolex / KEI) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish. (On Board)
Supply and fixing angular batten holder (Anchor) on 75mm dia PVC round block/round bakelite on wall/ceiling as per GS
S & Fixing of 230V,12 wt LED Retrofit Lamp on the existing Holder (Make-Philips- STELLAR BRIGHT HIGH WATTAGE /OSRAM / WIPRO)
S&F 250V Timer DB 2+14 Way, LEGRAND make) with sheet steel enclosure , double door with 1No. 32A DP MCB ( ‘C’ Curve, 10 KA , LEGRAND),1No. 2A SP MCB ( ‘C’ Curve, 10 KA , LEGRAND-) & 1 No. 40A 4-pole contractor ( Make- L & T,Cat No. MCX 04 - CS97012 ), 1 No. 2M Astro time switch ( Make- L & T, Cat No. AUTS02AST00) incl. 1 No. Two Pole (ON-OFF-ON) 3 POSITION type Auto Manual Bypass Toggle Switch with internal wiring by suitable size PVC Copper wire and fixed on wall as per direction of E.I.C.
Supply and delivery of 3 Star 1.8W ton Tr capacity Split A.C machine of BEE rated cooling capacity of 25248 BTU/Hr.with rotary compressor with R-410 refrigerant room discharge air flow (CMH) 1400 cu. m/hr ( without standard kit) [ Make: OGENERAL- ASGA22FTTC (R410A) / Equvelant make of Zamil ]
Installation charges of above Split R.A.C. Machine incl. making arrangement for out door unit by suitable size angle iron frame as per direction of E.I.C.
Supply and drawing 5/8" & 1/4" copper refrigerant pipes with 9 mm thick rubber nitrile rubber insulation along with other accessories on the surface of wall
Supply and drawing copper communication & controlling cable of following size-- 4Core x 2.5 sq.mm copper cable (Make: Finolex / KEI / Polycab / Havells)
Supply and Laying 25 mm dia heavy type PVC hard pipe by shadding on wall incl. PVC "T", elbow , bend etc. for drain out the condense water incl. solvent solution & fixing materials.(Make - Supreme / Finolex / Precision )DLP 1 years from the date of completion & commissioning of whole project.
DAS ELECTRICAL ENGINEERING CO
MITRA ENTERPRISE
M/S DAS ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .