Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.9 L+₹7,850 (0.26%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹31.5 L+₹69,570 (2.26%)Rejected-Finance 1286 TOTA RAM KI DHANI JAISALMER RAJ 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹31.9 L+₹1.1 L (3.61%)Rejected-Finance JAISALMER | JAISALMER | RAJASTHAN | 342310 | L4 | Rejected-Finance Not being lowest |
Tender Value
₹33.2 L
EMD Value
₹66,400
Closing Date
27 Mar 2024, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
SPECIAL REPAIR TO BLDG NO. P-06 (OR LINE INCLUDING BATHROOM) IN CERTAIN UNIT AT MIL STN JAISALMER
2024_MES_644452_1
8355/23-24/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹66,400
Yes
27 Nov 2024
28 Feb 2024
29 Mar 2024
28 Feb 2024
27 Mar 2024
13 Mar 2024
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with hard/dense soil complete all as specified & directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
Taking down chowkhats or frame with shutters (w/o taking off shutters from the frame) n exc. 1.5 Sqm each complete all as specified & directed by Engineer-in-charge.
Taking down chowkhat or frames exe 1.5 sqm but not exc 4 sqm each with shutter (without taking off shutter from the frames) complete all as specified and directed by Engineer-in-charge.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded all as specified & directed by Engineer-in-charge.
S&F pressed steel door framed of (size 165 x 60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified & directed by Engineer-in-charge. Note :- Rate quoted by the Contractor shall deemed to inclusive of filling of pressed steel door frame with PCC (1:3:6) type C1 (using 20mm graded stone aggregate).
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified & directed by Engineer-in-charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with single piece extruded PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement of single piece extruded PVC profile for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F 35 mm thick second class hard wood factory made plain, framed, panelled shutters, with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and Style as per IS:1003 (Part-1), kiln seasoned and chemically pressure treated all as specified & directed by Engineer-in-charge.
S&F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) complete all as specified & directed by Engineer-in-charge.
S&F, 100mm size, butt hinges, medium weight, cold rolled mild steel including necessary welding if required complete all as specified & directed by Engineer-in-charge.
S&F 150 mm size aluminium anodised barrel tower bolts of extruded section complete all as specified & directed by Engineer-in-charge.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & directed by Engineer-in-charge.
S & F 4.8mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.50 Sqm in each pane complete all as specified & directed by Engineer-in-charge.
S&F, glavanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aparture 1.00mm and fixed with tinned tack or galvanised wire stapples complete all as specified & directed by Engineer-in-charge.
Taking down all loose plaster and concrete if any in RCC columns, Chajjas, beams, parapet walls, slabs or any other type of RCC members,removing all loose ruts/scale from reinforcement etc by using wire brushes ,sand paper or any other chemicals, applying a coat appoxy coating on old reinforcement, tying IRC fabric of size 75x75mm of 3mm dia and binding with mild steel wire annealed with exsting reinforcement and applying cement slurry uniformaly to exposed surfaces and gunniting using CM 1:3 avg thickness of gunniting not less then 30mm and finishing the surfaces with 10mm thick rendering in CM 1:4 finished even and smooth with out using extra cement and removing the debris from the site, complete all as specified and directed by Engineer-in-charge. Note :- Rate quoted by the contractor shall deemed to enclusive of neccessary scafolding as per site requirement.
Demolition of loose particals of reinforced cement concrete of roofs, floors , beams, staircases, landing , chajjas, facia and similar suspended work and making good the surface with 10mm thick rendering in CM 1:4 finished even and smooth with out using extra cement and removing the debris from the site, complete all as specified and directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premise complete all as specified and directed by Engineer-in-charge.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregates) as in sub base of floors & finished the surface even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic colour tiles 350x250mmx7mm/ 450X350X7mm thick, in vertical surfaces etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick backing coat in CM (1:4) complete all as specified and directed by the Engineer in charge.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
S&F 12mm thick gypsum board in ceiling with 3mm thick wall care putty on ceiling with two coats of oil bound distemper alongwith Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including dismantling of wall and ceiling boards (fibre, pulp, insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete (un reinforced) in ground floors and pavings n.exc 15 cm thick (below or above ground level) & removing rubbish out side MD land all as directed by Engineer-in-charge.
M&L for 75 mm thick plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base of flooring/ hard standing & finished the surface even & fair without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed by Engineer-in-charge. Note :- Rate quoted by the contractor shall deemed to enclusive of packing of plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) for sides of payment.
Taking down cement plaster of any description on stone or brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
M&L for rendering 10 mm thick on stone masonry surfaces or surfaces other than fair faces of brick work or on one side of lathing in cement mortar 1:4 & finished the surface even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick on stone masonry surfaces or surfaces other than fair faces of brick work or on one side of lathing in cement mortar 1:6 & finished the surface even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for rendering 5 mm thick in CM (1:3) on fair faces of concrete surfaces as in ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for preparing new plastered or unplastered surfaces and applying three coats of white wash on ceiling all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of distempering oil emulsion over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L for prepration of new plastered wall surfaces of any description over 10cm girth or width, not otherwise described and applying two coat of weather proof paint over a coat of weather proof primer complete all as specified & directed by Engineer-in-charge.
M&L for 100 mm thick plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in flooring/ hard standing & finished the surface even & fair without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) laid in alternative bays as in plinth protection including finished the surface even & fair without using extra cement & filling the joints with mastic filling i.e one part of bitumen 85/25, 3 parts of sand by weight complete all as specified and directed by Engineer-in-charge.
S&F in repair, tubular towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges fixed with chromium plated brass screws complete all as specified & directed by Engineer-in-charge.
S&F in repair harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified & directed by Engineer-in-charge.
M&L for preparing new or previously untreated wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified & directed by Engineer-in-charge.
Supplying and laying of 16mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/wall in repair complete all as specified & directed by Engineer-in-charge.
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches/wall in repairs complete all as specified & directed by Engineer-in-charge.
S&F in repair 15mm dia Bib taps cast copper alloy chromium plated with crown or capstan head, screwed down, high pressure screwed for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F in repair, Vitreous china wash basin pedestal type, white, flat back, size 550 X 400 mm excluding taps, chain and plug and porcelain stopper but including CP waste coupling & brackets and fixed complete all as specified & directed by Engineer-in-charge.
S&F in repair brass CP wall mixer of 15mm dia bore for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified & directed by Engineer-in-charge.
S&F in repair 15mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified & directed by Engineer-in-charge.
S&F in repair brass chromium plated shower rose with swivel joints 125mm dia with 18mm dia chromium plated pipe complete all as specified & directed by Engineer-in-charge.
S&F in repair 20 mm bore gun metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F in repair, 1000 ltrs capacity white colour three layer rotational moulded polythene water storage tank (Cylinderical vertical with closed top) hoisted and fixed in position with 20mm bore dia ball brass valves high pressure, with polythene float and flynut screwed for iron pipe or brass ferrule including dismantling of existing tank with float valve complete all as specified & directed by Engineer-in-charge.
S&F in repair vitreous china wash down water closet pedestal pattern including connecting to flush tank complete all as specified & directed by Engineer-in-charge.
S&F in repair, health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified & directed by Engineer-in-charge.
S&F in repair orissa pattern vitreous china squatting pan white of size 580x440mm with integral footrest (Excluding flushing cistern and flush pipes) but including concrete bedding and P or S trap as required including PVC pipe up to finished floor level to connect flush pipe, making good all the disturbed surfaces to match the adjoining complete all as specified & directed by Engineer-in-charge.
S&F in repair 10 ltrs capacity PVC low level flushing cistern with inlet, ball valve, float, handle including fitting and fixtures and taking down the old damaged cisterns and providing connections to WC and flush pipe without damage to the existing fittings complete all as specified & directed by Engineer-in-charge.
M & L for 150mm dia Reinforced concrete pipes, class NP2, laid and jointed complete with collars including demolition and breaking up drain pipes NP2 including demolition of packing under and hauching against sides of pipes complete all as specified & directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 150mm bore pipe complete all as specified & directed by Engineer-in-charge.
S&F 5cm thick sand stone slabs Jaisalmer pattern/colour in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc not exceeding 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar (1:4) complete all as specified & directed by Engineer-in-charge.
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified & directed by Engineer-in-charge.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified & directed by Engineer-in-charge.
S & F 75 mm bore PVC (SWR) bends of any radius with access door complete all as specified & directed by Engineer-in-charge.
S & F 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified & directed by Engineer-in-charge.
S&F in repair, PVC connection pipe 15mm dia, 450mm long with PTMT check nuts and washer on both ends complete all as specified & directed by Engineer-in-charge.
S&F rolled mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe 410 -W (Gde- E- 250) quality- A with dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified & directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zine coating GI based corrugated steel sheeting 0.50mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws including dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, all as specified & directed by Engr-in-charge. Note : The fixing of Galvalume roof sheet used as sun-shades & in walls at certain places in repair to be fixed by done of 100mm grooves cutting with making good surface are inlcuding in the cost of item itself. No extra cost shall be paid for the same.
S&F in repair soap dish, vitreous China white, approximate size 160x 160x90mm fixed to plugs with chromium plated brass screws complete all as specified & directed by Engineer-in-charge.
S&F in repair shelf of PTMT shelf fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified & directed by Engineer-in-charge.
Demolition of brickwork or stone/ boulder/block masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer-in-charge.
M&L for Precast cement concrete 1:3:6 type C1 (Using 20 mm graded granite stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
M&L squared rubble walling Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
S&F in repairs cast iron nahani trap with CP grating including jointing to waste pipe in cement mortar, diameter of out let 75mm bore fixed in cement concrete type B1 (1:2:4) complete all as specified & directed by Engineer-in-charge.
M&L for 25mm thk PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate) as in subbase of floors, on roof top as padding & finishing the surface even & smooth without using extra cement including complete removal of existing roof treatment complete all as specified & directed by Engineer-in-charge.
M&L for water proofing treatment on roofs of slabs including removal/taking down of existing treatement of any description and applying acrylic based polymer modified cementitious elastomeric flexible composite coating system consisting of applying: First coat applying with CICO TAPECRETE-P151 or equivalent in FOSROC/STP/SIKA/BASF, mixed with neat cement in the ratio of 1:1 by weight after making the surface dust free and moist the surface. Laying second layer of Fiber glass cloth of 45 GSM when the first layer is still green. Overlaps of joints of fiber cloth should not be less than 10 cm. Applying final layer of cementitious elastomeric flexible composite coating system. The whole terrace so finished shall be flooded with water for a minimum period of 24 hours for curing and for final test. Note :- The work shall carried out through on authorised applicator.
HIGH BUILD ELASTOMERIC LIQUID MAMBRANE (PU BASED): M & L For applying of polyurethane based tar extended seamless elastomeric protective coating system, conforming to ASTM C-836-03 and ASTM C 898-09 ideally suited for waterproofing of roof, walls and foundation complete all as specified & directed by Engineer-in-charge. MAKE: CICO CORCHEM 206I or equivalent in FOSROC/STP/SIKA/ BASF, following the single component solvent based polyurethane compound CORCHEM 2P or equivalent in FOSROC/STP/ SIKA/ BASF recommended to be used as a primer. Note :- The work shall carried out through on authorised applicator.
M & L for providing and applying seamless thermal insulating elastomeric high build liquid membrane for concrete roofs, exterior wall and exposed surface. Make : CICO THERMOSEAL XL or equivalent in / FOSROC/ SIKA/STP Limited as approved with dual effects by reflecting more than 80% of sun rays thereby heating of roof surface reduces remarkably due to high amount of Titanium di oxide & transfer of heat from roof surface is blocked due presence of ceramic micro sphere with the application of roof and exterior side walls, it reduces energy cost approx 20% complete all as specified & directed by Engineer-in-charge. Note :- The work shall carried out through on authorised applicator.
Note : For item Ser No 72 to 74 (i) The structural rehabilitation treatment shall by the authorised applicator of main manufacturer. (ii) Contractor have to get prior approval for an authorisedf applicator from GE before carryout the work. (iii) The contractor has to submit a written guarantee for effectiveness of the treatment as specified here-in-after in particular specifications in addition to manufacturers guarantee/warantee. (iv) Rate quoted by the contractor shall deemed to enclusive of necessary scafolding.
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc ,removal to store for safe custody for issue under schedule of credit and making good disturbed surfaces complete all as specified & directed by Engineer-in-charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-charge.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-charge.
Taking down of old unsv tubelight fitting /surface panel light / flood light of any description light fitting any type any watt complete all as specified & directed by Engineer-in-charge.
M& L Point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm with 3 mm thick phenolic laminated white sheet cover for mounting of Piano Type switches, sockets, fan regulators complete for the following :-
(a) One light point controlled by one switch.
(b) One ceiling/ exhaust fan point controlled by one switch.
(d) One socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No 80.00 here on before but with copper conductor cable of nominal class area 2.50 sq mm for phase, neutral & earth for One 2/3 pin socket outlet 5 Amps on independent board complete all as specified & directed by Engineer-in-charge.
All as per item No 80.00 here on before but with copper conductor cable of nominal class area 4.0 sq mm for phase, neutral & earth for power socket point 15 Amps complete all as specified & directed by Engineer-in-charge.
S&F switch piano flush button single pole one way 5/6 amp complete all as specified & directed by Engineer-in-charge.
S&F switch piano flush button single pole one way 16 amp complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 5 pin 16 amp flush type complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete all as specified & directed by Engineer-in-charge.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete all as specified & directed by Engineer-in-charge.
S&F ceiling rose 6 amp, 3 plates polycarbonate body complete all as specified & directed by Engineer-in-charge.
S&F building security light fitting LED 35 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as lighting souce and PC cover having TOP opening sepreate drive compartment with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable of size 1.5 Sqmm complete all as specified & directed by Engineer-in-charge.
S&F bracket of GI pipe medium grade of 40mm dia, 1.2 meter in length clamps made of FI 40 mm x 6mm incl nuts, bolts & washers, painting and including taking down existing bracket complete all as specified & directed by Engineer-in-charge.
Supply and fixing of LED box type integrated batten 40 watt having aluminum extruded housing in white powder coated Finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Dimensions of the Fitting Shall be Not less then 1200 mm (Length) X 40 mm (Width) X 63 mm (Height ). Lumens output of the fitting shall be not less then 4000 lm, CCT 5700 – 6500 K, buring hours 50,000 Surge Protector 4 KV, PF>= 0.95, Separate detachable type Electronic constant current drivers for easy replacement and aintenance, THD < 10% , Necessary mounting arrangements .The fixture shall be suitable for wall mounting /suspension mounting as per site requirement . The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM80 / Test Report as per PHILIPS Cat Part No. BN100C LED40S-6500 PSU L120 GR S4 or equivalent in Appx 'C' list of makes.
S&F LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten,extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver,optic diffused type ENDURA LINER NEO including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified & directed by Engineer-in-charge.
S&F MCB distribution board TPN, 415 V, 4 way double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified & directed by Engineer-in-charge.
S & F for MCB DB SPN 8 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole and neutral 63 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole 10 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge. Note :- Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable as earth wire and one run of PVC conduit shall be measured and paid as one unit length.
Taking down ceiling fan/ exhaust fan of any sweep, dismanting blade and including preparation, filling cavity applying one coat of synthetic enamel paint by spraying with machine, re-assembling the fan body to fan and re-fixing in its original position or any other position complete all as specified & directed by Engineer-in-charge. Note :- Rate quoted by the contractor shall deemed to inclusive of replacing of quarter pin, nut bolt with check nut, rubber real etc.
S&F fans ceiling fans complete with three blade, down rod, accessories 230 V, 1200 mm sweep colour with squirrel cage induction motor necessary connecting cable recommended / provided by manufacturer complete all as specified & directed by Engineer-in-charge. Note :- Length of down rod of fan shall provide as per site requirement.
S&F Steel body heavy duty exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified & directed by Engineer-in-charge.
Cutting of wall built in cement mortar of brick/stone masonry and making good for opening of window suitable for fixing of 300mm sweep exhaust fan and making good as per existing surface of wall complete all as specified & directed by Engineer-in-charge.
S&F water heater storage type (Geyser) vertical type, with steel inner container of capacity 25 ltrs, power Consumption 2.0 KW, BEE 5 star rated pressure rating >8 Bar electrically operated, AC 230 Volts, including as per site required Nos of fashner nuts required suitable size fixed in brick wall BEE 5 star rated complete all as specified & directed by Engineer-in-charge. Make: Havells Cat Part No : Monza DX GHWAMGSIN025 or equivalent in Appx 'C' list of makes.
M&L for PVC connection pipe chromium plated 15 mm dia both end threaded incl brass coupling bolt cone washer complete, length of pipe is not less than 450 mm suitable for Hot/ cold water system complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 15 mm bore dia medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls and ceilings or laid in floors etc complete all as specified & directed by Engineer-in-charge.
S&F 15 mm bore bib tap, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge.
S&F 15 mm bore stop valve, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for union complete all as specified & directed by Engineer-in-charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp as incomer complete all as specified & directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to galvanized iron wire 4 mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and GI cover and testing on completion and including taking down existing earthing complete all as specified & directed by Engineer-in-charge.
NOTE FOR ITEM No. 108.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing wire from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Supply, laying, testing and commissioning of LT UG, XLPE insulated, heavy duty, 1100 V grade of size 35 Sqmm 3½ core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old existing unserviceable cable complete all as specified and as directed by Engineer-in-Charge of following sizes:- Note : - Earthwork excavation sand cushioning, Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment.
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and n. exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 25 mm bore, 'light grade' galvanised, fixed to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
Bhawani Constructions
GEMRARAMCONTRACTOR
M/S MAYA CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .