Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC 11 SANJIV BAUG SOCIETY NEW SHARDA MANDIR ROAD PALDI AHMEDABAD GUJARAT 380007 | AHMADABAD | GUJARAT | 380007 | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹23.9 L+₹3.8 L (18.8%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹27.9 L+₹7.8 L (38.7%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L3 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹55,400
Closing Date
9 Nov 2020, 6:00 pmClosed
CHIEF ENGINEER R AND D DELHI
CHIEF ENGINEER R AND D DELHI,PROBYN ROAD-54
REPLACEMENT OF BER 08 PASSENGER (544 KG) LIFT OF PROGRAMME CENTRE (TECHNICAL EVALUATION CENTRE BUILDING) AT ADRDE AGRA UNDER PROVN OF SPECIAL REPAIR BY GE (I) R AND D DELHI
2020_MES_376259_2
CE R AND D/DLI-10/2020-21
Open Tender
Civil Works
Item Rate
180 days
ADRDE AGRA
AS PER NIT
7 documents required · 7 mandatory
₹500
GE R AND D DELHI
₹55,400
Yes
8 Jan 2021
9 Oct 2020
12 Nov 2020
10 Oct 2020
9 Nov 2020
26 Oct 2020
Amount
Dismanting and taking down existing old unserviceable electrically operated 08 passanger (544 Kg) lift carefully and depositing in AGE E/M R&D Agra store yard complete.
Supply, install, testing & commissioning machine room less, Electrically operated with microprocessor based controls 8 Passenger, 544 Kgs suitable to serve G+2 upper floors with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex automatic and manual dual Closed loop controlled operation with/without attendant, telescopic opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set & human interface device(HID). all as specified below :- Note: (i) Contractor to submit detailed construction drawings of lifts being provided with complete technical specifications as per IS: 14665 before dispatch of material from OEM for approval of GE. (ii) The existing lift well dimension are 1875 mm x 1650 m, centre opening door size 800 x 2020 mm (LHS & RHS wall-545 mm) Head room height- 4200 mm approximate, floor traveling height 3620 m. However contractor is advised to visit the site before quoting the rate and for dimension of lift well a certificate from GE may please be obtain for its correctness of the dimension. (iii) Any civil / mechenical work required for proposed installation of new lift with respect to safety required by OEM will be carried out by the contractor, cost of same shall be deemed included in the quoted rate. (iv) The contractor shall be responsible for 2 years defect laibility period from certified date of completion of GE. During the said defect liability period the lift,shall be kept functional/serviceable all the time & all consumable items shall be provided by contractor or operation & maintenance of lift. All periodical maintenance regular check up/inspection shall be carried out by OEM during 02 years defect liability period.In addition to regular checkups and periodical services special visit/inspection will also be carried out to rectify defects by representative of OEM if any emergency / trouble developed.An agreement will be made between contractor & OEM ,And this shall be submitted to GE on the date of handing over of lift (date of completion phase-I) for the maintenance of defect liability period. The cost of above shall be deemed to be included in the quoted rates.
BASIC DATA (a) Type of Lifts : Passenger. (b) Load & capacity : 544 Kgs/ 08 Persons (c) Speed : 1.00/ mtr/sec with single speed motor (d) Power Supply : 415 volts, 3 phase AC, 50 Hz (e) Stpos and openings : 3 Stops and 3 openings, Single entrance Car. (f) Travel hight : 3 Floor. (g) Grouping : Simplex, Full collective. (h) MAP Floor position : Top most floor. (j) Car size : 1100 mm wide x 1300 mm deep x 2200 mm height or as per IS. (k) Door size : 800 mm wide x 2000 mm height. (l) Door type : Two- panel Centre opening , telescopic stainless steel with Air vent, automatic operated door. (m) Indicators : Hall position indicator car & landing direction and position, indicator with stainless steel fixtures at all floor.
FINISHES (a) Car design : Stainless steel hair line finish/mirror polished (b) Car panel finish : Mirror polished stst. (c) Hand rail : Round bend hand rail stainless steel at rear wall. (d) Ceiling and lighting : Intigrated roof RL20 ST3, Rose golden brushed StSt ring lighting LED. (e) Flooring : 20 mm Reecess and granite stone. (f) Car door finish : Stainless steel hairline finish. (g) Landing door finish : Floor Number - 0-2, Floor mark 0,1,2, Inter floor distance - 3800 mm, Landing door material- Stainless steel hairline finish. (h) Car opening panel : 1 Full height ST16, dark grey brushed StSt, Tempered glass segmented LCD display round flush mounted KDS96. (j) Landing signalization : TG, Tempered glass segmented LCD display flush mounted TG, tempered glass round flush mounted KDS96
STANDARD FEATURES (a) Car emergency light, Fireman drive, Curtain of light 169 beams, Accurate relevelling, Automatic closed door. (b) Emergency rescue device with audio announcer, nudging attendent service, ring lighting LED. (c) Digital direction and position indicator in car and at all landings. (d) Emergency alarm at the main landing. (e) 2 Phase fire man drive, fire man switch at the main landing.( In case fire man drive is activated the lift will come to the main landing and open the door) (f) Advanced door operation ( To ensure smooth opening and closing of the doors at adjustable door speed) (g) Additional pressure sensing device. (h) Load weighing device ( Audio visual over load indicator in the car for better safety) (j) Full height infra-red curtain ( Highly sensitive safty device for safe entrance and exit of the passangers in to the car).
(k) Pit ladder ( To ensure safety of the maintenance personnel). (l) Emergency light, Intercom and alarm with maintenance free rechargable battery operation ( To ensure passenger comfort and safety in case of emergency) (m) Over speed governor ( Electro mechenical device that prevents free fall in case the elevator is travelling at speed more than 10 % of the rated speed in down ward direction) (n) Automatic rescue device ( To rescue the passengers in case of emergency, the device will bring the car to the nearest floor automatically and will open the doors). (o) Special car door lock, Automatic daily brake testing, Latest technology motor-PMS, Touch panel with LCD display, Stainless steel doors. (p) Mechanical rescue device with no dependence with battery. (q) Cross flow fan, 2 way built in communication system, anti nuisance car call protection. (r) Any other accessories / safety device required as per IS for safety of passengers.
Supply , laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm Sqmm 3.5 Core
M&L for earthing with copper earth plate electrode of size 60x60x3.15 mm thick buried directly in ground to a depth not less than 2.25 Mtr deep below normal ground level with top edge of the earth plate not less than 1.5 Mtr deep below normal ground level connected to copper strip of size 20x3 mm as earthing lead by means of nuts, bolts and washers of copper / brass after welding/brazing of copper strip to earth electrode to the full length of earth plate, 25 mm dia GI tubing light grade protection pipe up to test point, 20 mm dia GI watering pipe medium grade with funnel and wire mesh , PCC pit 1:3:6 with pit cover of size 30x30 cm made of RCC 1:3:6 with suitable handle, angle iron frame made of angle iron of size 40x40x4 mm, adequate qty of charcoal dust and salt layers all around the earth plate ,removal of surplus soil and returning and filling in all as required at site including test point made out of steel plate of size 75x75x6 mm fixed to wall as specified in plate No. 3 of SSR Part-I and directed by Engineer-In-charge.
Excavation in trenches in soft/loose soil not exceeding 1.5m depth not exceeding 1.5m in width over energised LT cables for carrying out brick work for preparation of cable duct including for taking out and relaying of LT Cables complete all as specified and as directed by Engr in Charge.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick as in soft/loose soil complete all as specified and as directed by Engr in Charge.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level and not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engr in Charge.
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and as directed by Engr in Charge.
Supplying and laying reinforced precast concrete cable cover, class Class LV, Type I, flat, size 250mm x 150mm x 40mm, for protection of cable laid in trenches complete all as specified and as directed by Engr in Charge.
Supply and laying GI pipe light grade of 50mm dia laid in trenches for protection of UG cable complete all as specified and as directed by Engr in Charge.
Material & labour for point wiring complete with FRLS, PVC insulated unsheathed cable, 1100 volts grade confirming to IS-694, ISI marked, 1.5 Sq mm (nominal area) single core with copper conductor, multistranded drawn through and including non metalic rigid PVC conduit and conduit accessories concealed in walls, floors, roofs etc, complete including provisioning of FRLS, PVC insulated un-sheathed 1100 volts grade, ISI Marked, 1.5 sq mm multistranded copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and as directed for One light / fan / bell point controlled by one switch,complete all as specified and as directed by Engr in Charge..
Supply and fix, Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head light fitting, 10 w, IP66, 230V, 50 Hz, complete with all ccessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size,complete all as specified and as directed by Engr in Charge.
Supply and fix, Switch piano, flush type single pole, one way 5 Amp complete all as specified and as directed by Engr in Charge.
Material & labour for ceiling rose, 3 terminal, PVC / polycarbonate, isolated body complete all as specified and as directed by Engr in Charge.
M&L for Sheet metal enclosures for MCB DB Triple pole and neutral, double door, 4 way, 415 volts, powder coated with IP 43 protection, including provision and housing MCB,s and fixed flush on wall and grouting complete all as specified and as directed by Engr in Charge. Notes:- (a) The cost of fixing the DB flush to brick / stone wall surface, including cutting holes / chases, packing around the DB, making good and finishing to match surrounding surfaces shall be deemed to be included in the quoted rates. (b) MCBs shall be measured and paid separately.
Supply and fix, MCB, TPN, 415 volts, 63 Amps, 10 kA complete all as specified and as directed by Engr in Charge.
Supply and fix, MCB, SP, 6-32 Amp complete all as specified and as directed by Engr in Charge.
M & L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6 mm thick as earth electrode with top edge of the earth plate not less than 2.25 mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade 15mm dia from earth plate to main switch board/panel , watering pipe 20 mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil remaining surplus excavated material all as directed at site and specified in EP No 3 of SSR part I, complete all as specified and as directed by Engr-in-Charge.
Choice india
M/s Dhapola Elevator and Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .