| 1 | L1₹29.0 LAccepted-AOC | ₹29.0 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹30.7 L+₹1.7 L (5.88%)Rejected-Finance AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | ₹30.7 L+₹1.7 L (5.88%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹32.5 L+₹3.5 L (12.0%)Rejected-Finance | ₹32.5 L+₹3.5 L (12.0%) | L3 | Rejected-Finance Other than L1 |
| 4 | Rejected-Technical HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | - | - | Rejected-Technical Not Recommended since No reflected in WLR issued by HQ CENC for QE Dec 2025 at Appx A Srl No 114. |
| Sl No | Description | Qty | Unit | darshan kumar gandhi L1 | M/S NANCY ENTERPRISES L2 | Intrernational Engineers L3 |
|---|---|---|---|---|---|---|
| 1.00 | Disconnection of Transformer connection 250 KVA from HT and LT side carefully after taking proper safety measures and shifting the same in MES store yard with proper T&P and vehicle, complete all as specified and/or as directed by Engr-in-Charge. | 1 | Job | 5,000 ₹5,000 Lowest | 30,000 ₹30,000 | 10,000 ₹10,000 |
| 2.00 | Supply, installation, testing and commissioning of step down Transformer 11/0.415 KV capacity 400 KVA level III, IS-1180 Part-I outdoor type copper wound 3 phase 4 wire, 50 cycle per second, oil immersed naturally cooled external cooling tube core type Delta connection on primary side (HV side) and star connection on secondary side (LV side) having typing 0, + 2.5%, + 5%, + 7.5% to charged by means of hand operated, off load/ tap charging gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fitting with such as two earthing terminals for body and one additional for neutral brought out in bushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and terminal plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling value 20 mm bore steel with plug, dial type thermo meter, oil filling hole 32 mm threaded with plug. The transformer shall be powder coated for water/ dust and vermin proof.
Note- (1) Transformer oil shall be confirming to requirement of IS 335-1983 specification for new insulating oil for transformer. (2) Equipment shall be suitable to operate at 3500 Mtr above MSL at temperature variation between (-) 25 degree centigrade to (+) 35 degree centigrade, complete all as specified and/or as directed by Engr-in-Charge. | 1 | Each Job | 18,99,900 ₹18,99,900 Lowest | 20,50,000 ₹20,50,000 | 21,25,000 ₹21,25,000 |
| 3.00 | S&F HT 11 KV outdoor type gang operated air break switch suitable for horizontal or verticle mounting type complete with 9 insulators upto 200 Amps complete including taking down existing old unserviceable air break switch, complete all as specified and/or as directed by Engr-in-Charge. | 1 | Each | 15,500 ₹15,500 Lowest | 35,000 ₹35,000 | 15,900 ₹15,900 |
| 4.00 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, complete all as specified and/or as directed by the Engr-in-Charge. | 2 | Each | 4,200 ₹8,400 | 2,500 ₹5,000 Lowest | 5,500 ₹11,000 |
| 5.00 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for laying of cable in trenches/foundation of pole and stay etc and getting out in soft/loose soil complete all as specified. | 20.25 | Cum | 120 ₹2,430 | 90 ₹1,822.5 Lowest | 140 ₹2,835 |
| 6.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in soil complete all as specified and/or as directed by the Engr-in-Charge. | 12 | Cum | 30 ₹360 | 10 ₹120 Lowest | 30 ₹360 |
| 7.00 | Removing excavated material to a distance not exc. 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point all as specified and/or as directed by the Engr-in-Charge. | 8.25 | Cum | 10 ₹82.5 Lowest | 10 ₹82.5 Lowest | 30 ₹247.5 |
| 8.00 | Material and labour for Sand cushioning to under ground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, 2009.
Note : Punned thickness only will be measured and paid. | 6 | Cum | 300 ₹1,800 | 250 ₹1,500 Lowest | 1,000 ₹6,000 |
| 9.00 | Supply and laying of factory made, machine pressed, unreinforced, precast concrete cable cover class LV type-1 flat size 250 mm x 150 mm x 40mm, complete all as specified and/or as directed by Engr-in-Charge. | 500 | Each | 23 ₹11,500 | 17 ₹8,500 Lowest | 25 ₹12,500 |
| 10.00 | Supply, laying and testing of XLPE insulated, armoured electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade, cross sectional area 240 sqmm 3.5 core laid in trences or passing through pipes, ducts or fixed to walls/poles, complete all as specified and/or as directed by Engr-in-Charge. | 250 | RM | 2,220 ₹5,55,000 | 1,650 ₹4,12,500 Lowest | 2,100 ₹5,25,000 |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
14 Jul 2026, 6:00 pmClosed
CWE, HQ 138 WE
CWE, HQ 138 WE
UPGRADATION OF EXISTING TRANSFORMER FROM 250 KVA TO 400 KVA FOR CORPS ENGR SIGNAL REGT UNDER AGE E/M-II OF GE 865 EWS, LEH
2026_MES_772546_1
138WE/L-27/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
As per Tender Documents
6 documents required · 6 mandatory
₹500
GE 865 EWS
₹59,000
Yes
29 Aug 2026
16 Jun 2026
21 Jul 2026
16 Jun 2026
14 Jul 2026
30 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Disconnection of Transformer connection 250 KVA from HT and LT side carefully after taking proper safety measures and shifting the same in MES store yard with proper T&P and vehicle, complete all as specified and/or as directed by Engr-in-Charge. | 1 | Job | - | - |
| 2 | Supply, installation, testing and commissioning of step down Transformer 11/0.415 KV capacity 400 KVA level III, IS-1180 Part-I outdoor type copper wound 3 phase 4 wire, 50 cycle per second, oil immersed naturally cooled external cooling tube core type Delta connection on primary side (HV side) and star connection on secondary side (LV side) having typing 0, + 2.5%, + 5%, + 7.5% to charged by means of hand operated, off load/ tap charging gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fitting with such as two earthing terminals for body and one additional for neutral brought out in bushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and terminal plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling value 20 mm bore steel with plug, dial type thermo meter, oil filling hole 32 mm threaded with plug. The transformer shall be powder coated for water/ dust and vermin proof.
Note- (1) Transformer oil shall be confirming to requirement of IS 335-1983 specification for new insulating oil for transformer. (2) Equipment shall be suitable to operate at 3500 Mtr above MSL at temperature variation between (-) 25 degree centigrade to (+) 35 degree centigrade, complete all as specified and/or as directed by Engr-in-Charge. | 1 | Each Job | - | - |
| 3 | S&F HT 11 KV outdoor type gang operated air break switch suitable for horizontal or verticle mounting type complete with 9 insulators upto 200 Amps complete including taking down existing old unserviceable air break switch, complete all as specified and/or as directed by Engr-in-Charge. | 1 | Each | - | - |
| 4 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, complete all as specified and/or as directed by the Engr-in-Charge. | 2 | Each | - | - |
| 5 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for laying of cable in trenches/foundation of pole and stay etc and getting out in soft/loose soil complete all as specified. | 20.25 | Cum | - | - |
| 6 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in soil complete all as specified and/or as directed by the Engr-in-Charge. | 12 | Cum | - | - |
| 7 | Removing excavated material to a distance not exc. 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point all as specified and/or as directed by the Engr-in-Charge. | 8.25 | Cum | - | - |
| 8 | Material and labour for Sand cushioning to under ground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, 2009.
Note : Punned thickness only will be measured and paid. | 6 | Cum | - | - |
| 9 | Supply and laying of factory made, machine pressed, unreinforced, precast concrete cable cover class LV type-1 flat size 250 mm x 150 mm x 40mm, complete all as specified and/or as directed by Engr-in-Charge. | 500 | Each | - | - |
| 10 | Supply, laying and testing of XLPE insulated, armoured electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade, cross sectional area 240 sqmm 3.5 core laid in trences or passing through pipes, ducts or fixed to walls/poles, complete all as specified and/or as directed by Engr-in-Charge. | 250 | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TenderL27202627.pdf
Tender Documents • 1.23 MB
BOQ_865059.xls
BOQ • 2.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .