Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.3 LAccepted-AOC 275 2 AJIT NAGAR UPPER GADIGARH AIR PORT ROAD JAMMU INDEX NO D 04 ADGNJ | JAMMU | JAMMU AND KASHMIR | 180001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹51.0 L+₹1.0 L (2.09%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder. | |
| 3 | L3₹52.0 L+₹2.0 L (4.00%)Rejected-Finance 5 A LANE 1 GREATER KAILASH JAMMU J K 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L3 | Rejected-Finance Other than lowest bidder. | |
| 4 | L4₹58.3 L+₹8.3 L (16.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder. | |
| 5 | L5₹62.3 L+₹12.3 L (24.7%)Rejected-Finance H NO 39 3 CHANNI HIMMAT JAMMU 180015 J K | JAMMU | JAMMU AND KASHMIR | 180015 | L5 | Rejected-Finance Other than lowest bidder. |
| Sl No | Description | Qty | Unit | M/S ARUN ANAND L6 | GENESIS INDIA L1 | NARESH KUMAR AND COMPANY L3 | M/S ANIL MAHAJAN L5 | M/S RAJINDRA ENGINEERS & CONTRACTORS L2 | JK BUILDERS AND DEVELOPERS L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of Reinforcement cement concrete((reinforcement cut as required to facilitate demolition) in ground floors and paving not exceeding 15 cm thickness, below or above ground level all as specified and as directed. | 12 | Cum | 150 ₹1,800 | 65 ₹780 Lowest | 100 ₹1,200 | 1,200 ₹14,400 | 90 ₹1,080 | 150 ₹1,800 |
| 2.00 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. | 42.6 | Cum | 100 ₹4,260 | 65 ₹2,769 Lowest | 100 ₹4,260 | 600 ₹25,560 | 90 ₹3,834 | 150 ₹6,390 |
| 3.00 | Taking down cement plaster on bricks or stone wall/ decayed surfaces of concrete from roof projectiokn or RCC Chajjas etc. including racking out joints, hacking for key, scrubbing down with water, etc. all as specified and as directed. | 2,275.5 | Sqm | 10 ₹22,755 | 5 ₹11,377.5 Lowest | 15 ₹34,132.5 | 30 ₹68,265 | 10 ₹22,755 | 20 ₹45,510 |
| 4.00 | Dismantling floor, hearth or wall tiling , terrazzo topping on walls including cement mortar ,bedding (but no backing) removing serviceable tiles and rubbish off the premises complete all as specified and directed. | 885 | Sqm | 30 ₹26,550 | 5 ₹4,425 Lowest | 12 ₹10,620 | 100 ₹88,500 | 15 ₹13,275 | 20 ₹17,700 |
| 5.00 | Dismantling cast iron or reinforced concrete or PVC drain pipes of 75/100mm bore, fixed with walls and taking out of trenches, if required all as specified and directed. | 24 | Rm | 30 ₹720 | 5 ₹120 Lowest | 10 ₹240 | 10 ₹240 | 10 ₹240 | 20 ₹480 |
| 6.00 | Taking down chowkats or frames with shutters (without taking off shutter from the frames) not exceeding 1.5 sqm each complete all as specified and directed | 30 | Each | 300 ₹9,000 | 65 ₹1,950 | 80 ₹2,400 | 200 ₹6,000 | 10 ₹300 Lowest | 100 ₹3,000 |
| 7.00 | Taking down chowkats or frames with shutters (without taking off shutter from the frames) exceeding 1.5 sqm & not exceeding 4 sqm each complete all as specified and directed | 54 | Each | 350 ₹18,900 | 65 ₹3,510 | 100 ₹5,400 | 250 ₹13,500 | 10 ₹540 Lowest | 100 ₹5,400 |
| 8.00 | Demolition of brick work masonry built in cement mortar including all quoins, pillars etc but excluding ashlars facing, dressed stone work and precast concrete articles complete all as specified and as directed. | 18 | Cum | 390 ₹7,020 | 65 ₹1,170 Lowest | 150 ₹2,700 | 500 ₹9,000 | 90 ₹1,620 | 120 ₹2,160 |
| 9.00 | Material & labour for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, complete, all as specified and as directed. | 15 | Cum | 6,000 ₹90,000 | 3,499 ₹52,485 | 3,400 ₹51,000 Lowest | 5,500 ₹82,500 | 4,000 ₹60,000 | 5,000 ₹75,000 |
| 10.00 | Material & labour for Brick work with sub class ‘B’ bricks ,straight or curved on plan exc 6 m mean radius and built in cement mortar 1:6 complete , but except bricks , i.e using serviceable bricks obtained from demolition complete all as specified and directed | 3 | Cum | 4,800 ₹14,400 | 2,099 ₹6,297 | 3,300 ₹9,900 | 4,000 ₹12,000 | 1,800 ₹5,400 Lowest | 2,500 ₹7,500 |
Tender Value
₹72.8 L
EMD Value
₹2.2 L
Closing Date
6 Apr 2026, 6:00 pmClosed
Col Amit Bhardwaj
HQ CWE Jammu PIN 180003
SPECIAL REPAIR TO COOK HOUSE BUILDING NO T-165,P-409 AND P-410 OF 215 TRANSIT CAMP OF BD BARI MIL STN UNDER GE KALUCHAK
2026_MES_756509_1
CWE/JP-95/2025-26
Open Tender
Civil Works - Others
Item Rate
210 days
GE Kaluchak
As per Tender Documents
9 documents required · 9 mandatory
₹1,000
Yes
GE Kaluchak
₹2.2 L
Yes
4 May 2026
16 Mar 2026
8 Apr 2026
16 Mar 2026
6 Apr 2026
30 Mar 2026
16 Mar 2026 - 19 Mar 2026
Demolition of Reinforcement cement concrete((reinforcement cut as required to facilitate demolition) in ground floors and paving not exceeding 15 cm thickness, below or above ground level all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Taking down cement plaster on bricks or stone wall/ decayed surfaces of concrete from roof projectiokn or RCC Chajjas etc. including racking out joints, hacking for key, scrubbing down with water, etc. all as specified and as directed.
Dismantling floor, hearth or wall tiling , terrazzo topping on walls including cement mortar ,bedding (but no backing) removing serviceable tiles and rubbish off the premises complete all as specified and directed.
Dismantling cast iron or reinforced concrete or PVC drain pipes of 75/100mm bore, fixed with walls and taking out of trenches, if required all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames) not exceeding 1.5 sqm each complete all as specified and directed
Taking down chowkats or frames with shutters (without taking off shutter from the frames) exceeding 1.5 sqm & not exceeding 4 sqm each complete all as specified and directed
Demolition of brick work masonry built in cement mortar including all quoins, pillars etc but excluding ashlars facing, dressed stone work and precast concrete articles complete all as specified and as directed.
Material & labour for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, complete, all as specified and as directed.
Material & labour for Brick work with sub class ‘B’ bricks ,straight or curved on plan exc 6 m mean radius and built in cement mortar 1:6 complete , but except bricks , i.e using serviceable bricks obtained from demolition complete all as specified and directed
Material & labour for 75 mm thick PCC 1:3:6 type C-2, (using 40mm graded crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
Material & labour for Non - skid ceramic coloured jointless tile 400mm x 400mm x 7mm thick as in floors laid over and including 15 mm thick screed bed or bedding layer of cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles complete, all as specified and directed.
Material & labour for Non - skid ceramic coloured jointless tiles 400mm x 400mm x 7 mm thick on vertical surfaces such as skirting /dado etc bedded & jointed in neat cement slurry over and including 10 mm thick backing coat of cement mortar 1:4 and pointed in white or coloured cement to match the colour of tiles complete, all as specified and directed.
Material & labour Glazed ceramic coloured joint free tiles 300x450mmx7mm thick for work vertical surfaces such as shirking/dado and risers to step etc set and jointed in neat slurry and pointed in white /coloured cement and pigment to match the tiles over and including 10 mm thick cement plaster in CM 1:4 ,including dismantling floor,hearth or wall tilling,cement mortar bedding(but not backing) , terrazzo toping complete, all as specified and directed.
Material & labour for machine cut kota stone slab flooring 20-25 mm thick over cement screed bed laid and jointed cement screed bed laidand jointed with grey cemant slurry mixed with pigment to match the shade of slab including rubbing and polishing complete for floor/ tread of staircase over and including15mm thick screed bed in CM 1:6 after roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.0 kg og cement per sq. metre complete, all as specified and directed.
Material & labour for 18 to 20mm thick black Granite stone (table rubbed and polished) in cooking plateform bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over 15mm thick screed bed in CM 1:4 after roughing surfaces of old concrete floor by picking sweeping down with water to remove dust etc including cutting holes into or through reinforced cement concrete slabs , for gas pipe (Superficial area wxc 100 sq cm but n. exc. 250 sq cm. complete, all as specified and directed.
Material & labour for Pressed steel frame for door with one or more rebates including necessary lugs, fixing lugs hinges, lock strike plate etc. of size 125mm x 60 mm and made of 1.25mm thick MS sheet, complete all as specified and directed including necessary welding complete and including medium weight 03 Nos of MS butt hinges of size 75mm / 100mm / 125mm and 01 No 50mm Size of medium weight MS butt hinge complete all as specified and directed.
Material & labour for Pressed steel frame for door with one or more rebates including necessary lugs, fixing lugs hinges, lock strike plate etc. of size 105mm x 60 mm and made of 1.25mm thick MS sheet, complete all as specified and directed including necessary welding complete and including medium weight 03 Nos of MS butt hinges of size 75mm / 100mm / 125mm and 01 No 50mm Size of medium weight MS butt hinge complete all as specified and directed.
Material & labour for PCC 1:3:6 type C - 2 (using 40 mm graded crushed stone aggregate) as in back filling of chowkats and bed blocks for hold fasts etc complete all as specified and directed.
Material & labour for 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides with both face is covered with deco rative face veneer with lipping/frame to match complete all as specified.(as directed by Engr-in-Charge)
Supply and fixing 35mm thick 2nd class hard wood Glazed and skeleton shutters open rebated & prepare to receive glass, gauge etc (without sash bars /edges of framing plain chamfered or rounded, fitted with cut and mitred beds for securing glass etc) size of members of shutters as spd in SSR Part-I section-8 clause 8.2 (A). .(as directed by Engr-in-Charge)
Supply and fixing Factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed.
Supply and fixing in frame with suitable size and 3 Nos of butt hinges Factory made solid panel PVC door shutter, 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet 5mm thick to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supplying & fixing in the frame at site. all as per specification and drawing. (Stiles and panel to be used of different colours) complete all as specified and as directed.
Material & labour for Factory made box type steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS sheet tube with double side shutters (Wire Gauged shutter and Glazed Shutter), side hung shutters with MS handles and MS stays dovetailed or welded including 02 nos MS Tower Bolt 150mm long for each leaf, 8 mm square guard bars at spacing as shown in drawings, MS flat iron frame work, MS hinges, tarred hold fast, PCC 1:2:4 type B1 as in bed of hold fast, 01 No. per leaf of stopper of 100mm size, one coat of red oxide zinc chrome primer etc, complete all as specified and shown as drawing No. CEPZ/TD-354/09 sheet 1/3 to 3/3. Note : a). Wire cloth and Sheet glass shall be measured and paid seprately under respective items. b). Rate of both type of shutters is inclusive in the quoted rate.
Material & labour for Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements, complete all as specified.
Supply and fixing Galvanized mild steel wire cloth 0.56 nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tank or galvanized wire staple complete all as specified and as directed.
Supply and fixing 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 Sqm in each pane complete all as specified and as directed.
Supply and fixing 3mm thick figured glass, pin head and glazing with oil putty in square not exc 0.5 Sqm in each pane complete all as specified and as directed.
Supply and fixing Butt hinges, medium weight, cold rolled mild steel, welded to steel frame work of 100mm size complete all as specified and as directed.
Supply and fixing 125mm size aluminium handle fabricated type anodized all as specified and as directed.
Supply and fixing 150mm long Aluminium, anodized, barrel tower bolts of extruded section complete all as specified and as directed.
Supply and fixing 300mm, MS ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
Supply and fixing 300 mm length of aluminium alloy anodised sliding door bolt.with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and directed.
Supply only liquid water proofing compound, all as specified and as directed.
Material & labour Rendering 10 mm thick in cement plaster 1:6 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Material & labour for rendering 5 mm thick in cm 1:3 on ceiling surfaces, finished even and smooth withot using extra cement complete all as specified and directed.
Material & Labour for RCC chajja/fascia/parapet repair by using following steps :- (a) Removal of existing concrete along with loose damaged and cracked concrete/cover concrete from chajjas etc, exposing corroded steel reinforcements upto a depth of 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting to chipped concrete and reinforcement all as directed by Engineer-in-charge. Hard concrete shall not be removed. However if the rebar is corroded, concrete around it shall be removed. (b) Cleaning the surface of reinforcement bars from dust by using wire brushes and dry cloth and applying FOSROC Rebakleens RR- Rust Remover or equivalent using small brush and allow to react it for 16-24 hrs. (c) Providing and applying two coats of Fosroc Nitozinc Primer - two component, zinc rich epoxy, anti-corrosive protective coating or equivalent by brushes to the exposed and cleaned rebars with an interval of 45minutes to 1 hour @ 40microns DFT / coat and allowed to completely dry for 24 hours all as directed by Engr-in-Charge.
Material & labour for Polymer modified repair mortar applied after removal of loose concrete & apply anti rust primer on exposed reinforcement bars thereafter applying epoxy bonding on entire concrete surface and finally apply polymer modified mortar (strength: 40 MPa after 28 days) upto 50 mm thick all as per manufacturer's instruction.
Capillary rise treatment of walls, Consumption base coat: 0.3 Kg/Sqm, Second and Third coat : Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalent, Consumption top coat: 3 Kg/Sqm, System requirements : density : 2.00 Kg/Ltr, Compressive strength: 0.5 N/Sqmm. complete all as specified and as directed.
Dismantling water tanks exceeding 250 ltr capacity but not exc 500 ltrs all as spd.
Dismantling water tanks exceeding 500 ltr capacity but not exc 1000 ltrs all as spd.
Supply and fixing Rotational moulded polythelene water storage tank double Layered (cyclinderical vertical with closed top) hoisted and fixed in position of 500 Ltrs capacity all as specified and as directed.
Supply and fixing Rotational moulded polythelene water storage tank double Layered (cyclinderical vertical with closed top) hoisted and fixed in position of 1000 Ltrs capacity all as specified and as directed.
Supply and fixing Ball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed complete of 20 mm bore dia all as specified and as directed.
Taking up or down 15 mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and as directed.
Supply and fixing Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia15 mm, all as specified.
Supply and fixing Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20 mm, all as specified.
Supply and fixingStop valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 20mm bore, complete, fixed in repairs, all as specified and as directed.
Supply and fixing repair 15mm stop cock cast cooper alloy chromium plated of screwed down high pressure with long shank and cup concealed type , screwed with ends for iron pipe or unions. Make ISI marked
Supply and fixing Bib taps, chromium plated cast copper alloy, with capstan head, screwed down for iron pipe or for brass ferrule and fixed for bore of pipe 15 mm, fixed in repairs, all as specified and as directed.
Supply and fixing PVC connection 15mm size with PTMT nuts of length 600mm long complete, fixed in repairs, all as specified and as directed.
Material & labour 100mm bore CI 'P' or 'S' traps, fixed in repairs all as specified and as directed.
Supply and fixing repair Vitreous china water closet Orissa pattern long pan size 580x440mm with trap front or back inlet and integral foot rest complete fixed in repair including lime concrete bedding and connection to drain or outgoing pipe and to flushing pipe and anti siphon pipe complete all as specified and as directed.
Supply and fixing repair Vitreous china wash hand basin, white , flat back, size 580 x 450 mm with brackets, including 32 mm waste coupling, cutting for and pinning in ends of brackets or erecting stand complete fixed in repairs all as specified and directed.
Supply and fixing sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs washers including 40mm waste coupling bedding in cement mortar to dwarf wall or including fixing cantilever brickets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm.
Supply and fixing repair Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘HOT or COLD’ with long screwed shanks and fly proof of 15 mm bore of pipe complete all as specified and as directed.
Supply and fixing repair PVC flushing cistern white shade low level 10 ltrs capacity, white with inlet ball valve, float and handle including bracket and flush pipe including connection to pipes, fixed in repairs complete all as specified and as directed.
Supply and fixing 32 mm bore PVC waste pipe 900 to 1000mm for WHB or Sink complete all as specified and directed.
Material & labour for Grating doom 100mm with or without waste hole of PTMT (Minimum weight 40 gm) all as specified and as directed.
Supply and fixing in repair 20mm dia ss steel coated drapery rods in one length per door/window, fancy type (engraved rods), designed & coloured as approved by GE providing with two nos of Bracket powder coated for holding curtain rod and Fiber fancy dome type or wall to wall fixed in repair complete all as specified.
PVC (SWR) pipes single socketed in any length with rubbering joints fixed to walls 110mm bore.
PVC (SWR) bends any radius 110mm bore with access door.
PVC(SWR) junction single (single 'T') equal or unequal 110mm bore with access to door ccomplete all as specified and directed.
Dismantling boarding any description fixed with screws complete all as specified and directed.
Supply and fixing Second class soft wood plain fillets square, rectangular or triangular in section, wrought secured with screws, cross sectional area exceeding 13 and not exceeding 25 Sq. cm
Material & labour for 18/19mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to timber frame work as in cupboards , kitchen cabinat etc fixed in repairs all as specified.
Supply and fixing Continuous (piano) hinges,width of flap when open is 30 mm mild steel, bright finish or electrogalvanised
Supply and fixing 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised.
Supply and fixing Magnetic catches of 25/30 mm size for cup Board shutter etc
Supply and fixing hasp and stapple, safety typeof Aluminium, anodised, including bolt to hinge type, fixed with screws of 100 mm complete all as specified.
Form work to soffit of suspended slab such as roof slab not exc 20 0 mm thick horizontal or slopinf flate including fair finished to concrete surfaces.
Form work to Edges of concrete flate floor and roof n.exc 20 cm wide and similar work exc 5 cm but not exc 10 cm wide rough finished to concrete surfaces.
TMT steel bars 10mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping to columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia, all as specified and directed.
Material & labour M-25 Type B-1 (using 20 mm graded aggregate) in Roof slab, shelves supported on wall/column and the like etc complete as required.
Preparation of new wooden surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed.
Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over red oxide primer, complete, all as specified and as directed.
Complete removal of existing treatment from internal wall surfaes including preparation of old surfaces and applying 2 coat of oil emulsion paint over a coat of alkali resistant primer complete all as specified and as directed.
Material & labour preparation of new surfaces of wall and applying 2 coats of oil bound distamper emulsion over a 2 mm thick wall care putty complete all as specified and directed.
Material & labour for Preparing newly plasterd surfaces of ceiling and applying 2 coat of white wash comlete all as specified.
Material and labour for preparation of newly plastered wall surface and applying two coat of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9ltr(undiluted)/10 sq mtrs diluted with water in 1:1ratio as per manufacture's instruction and all coats incl primer to be applied with fully automatic airlessspray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed Make: Berger Paints Weathercoat Long Life Flexo / Nerolac Paints excel Total / Asian Paint Apex Ultima /JK Maxima Ultra Notes for smart periodicals item no 1 to 4: (a) Work shall be done as per MoU between tenderer and manufacturer of paints and their authorized applicator complete all as specified and directed (b) The contractor shall upload MoU between tenderer and manufacturer of paints and their authorized applicator before quoting the bids and submit the same alongwith tender & other Documents as mentioned in NIT. (c) Cost of scaffolding at any height shall be included in thequoted rate. (d) Preparation of plastered or unplastered surface or removal of existing treatment by scrapping of walls, chajjas, ceilings, fins, fascias, parapets etc shall be done by using mechanial sander with internal dust extraction system for clean environment certified by the manufacturer. After the prepartion of surface written approval shall be obtained from GE before applying primer and further treatment/coats. Bldg wise stage passing register shall be maintained. e) Finishes ie cement based paint, acrylic water based exterior grade primer, premium acrylic smooth exterior emulsion etc to walls, ceiling, chajjas, fins, fascias, parapets etc shall be applied using airless spray technology and capable of operating single spray gun with a suitable hose length. the spray machine should be of are putted manufacturer with pro-guard technology and capability of tracking pressure as well as paint and primer usage. (f) This equipment shall be certified by approved manufacturer. (g) The accessories for applying the finishes shall be spray in hard to reach areas and penetration of finishes on the surface so as to achieve uniform application and quality surface finish.
Material and labour for complete removal of existing treatment including fascias, cornices etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint and loose plaster to be completely removed by skilled labour and repair of external wall/Chajjas to be done with repair mortar to get even surface including preparation of old surface of wall/ceiling by filling cracks by Berger Bison Putty / crack fill paste of Berger Paints or equivalent make and make good smoothen surface by sand paper and applying two coats of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9ltr(undiluted)/10 sq mtrs diluted with water in 1:1ratio as per manufacture's instruction and all coats incl primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI all as specified and directed. Allow 6-8 hrs to dry the surface in subsequent coats of paint and including necessary scaffolding at any height complete all as specified and directed Make: Berger Paints Weathercoat Long Life Flexo / Nerolac Paints excel Total / Asian Paint Apex Ultima/JK Maxima Ultra
Complete removal of existing roof treatment or roof tile and removing from site to a place outside defence land as specified by civil authorities and clean the surface of roof with water and remove dust complete all as specified.
Material & labour for Providing cement concrete type B-0 1:2:4 (using 12.5 mm graded stone aggregate ) in roof padding, roof kerbs or mud stops, rounded or chamfered on edges complete all as specified.
Material & labour for one component liquid ,solvent free ,cold applied , water-proofing membrane that is highly elastic and UV resistant with 10 years Warranty .ASTM D 6083-97a Waterproofing and heat reflecting systemhaving following key performance properties: 1.UV resistant ,prevent yellowing and weathering 2.Highly elastic upto 350% and crack bridging 3.Excellent adhesion on porous and non-porous substrates 4. Tensile Strength >10 N/mm2 with GeoTextile fleece 5. Soler Reflective Index (SRI) more then 109-111 ASTM E1980-11 System: First coat:Providing and applying primer over the prepared surface with HS PU roofkoat Primer(or equivalent) Coverage: 0.2kg/m2(with 50% dilution of water) Reinforcement: Geotextile 40 gsm Second coat:Home sheildroofkoat(or equivalent) Consumption: 0.5 kg/m2. Third coat: HS PU roofkoat(or equivalent) Consumption : 0.8 kg/m2. System buildup-1.5kg/sqm with geotextile of 40gsm For accessible roof, tiles with screed/ adhesive may be fixed thereafter.
Material & labour for 75 mm thick PCC 1:4:8 type D-2 using (40mm graded crushed stone aggregate ) as in sub base of floor complete all as specified and directed.
Material & labour for Precast designer coloured heavy duty full body paving tiles (factory made) of size 300mmx300mm x 10mm, top layer glazed made in any type of cement and pigment, in required patterns as approved by GE in floor etc set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, complete all as specified & directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan in any type of soil and getting out, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Material & labour for Concrete bed to 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 type D-2 using 40mm graded stone aggregate, and tested,for 100mm dia bore pipes all as per SSR Part-I specifications, complete all as specified and directed.
Supply and fixing 150mm diameter DWCPE (SN8) HDPE Pipes laid in trenches on PCC bed including jointing as per manufacturer's instructions and as directed. (Bedding/Haunching and earthwork paid separately under respective items of schedule)
Material & labour for Cutting salt-glazed stoneware drain pipe in position new drains (internal dia of pipe 100mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required
Material & labour for PCC 1:3:6 nominal mix, type C-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
Material & labour for Precast cement concrete 1:2:4 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), and similar articals with plain faces complete all as specified & directed.
Material & labour for TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness, below or above ground level all as specified and as directed.
Demolition of brick work masonry built in cement mortar including all quoins, pillars etc but excluding ashlars facing, dressed stone work and precast concrete articles complete all as specified and as directed.
Material & labour for Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:4, complete all as specified & directed.
Material & labour for PCC 1:4:8 nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
Material & labour for PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in benching, water troughs and the like including necessary form work, complete all as specified & directed.
Material & labour for PCC 1:3:6 nominal mix, type C-2 using 40mm graded crushed stone aggregate as in wall of surface channel and drain, complete all as specified & directed.
Material & labour for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl forms, moulds etc. complete all as specified & directed.
Material & labour for 15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
Taking down distribution boards/wooden board ,switch fuse units,steel enclosures for MCB of any type and removing from site all as specified and as directed by the Engineer in charge.
Taking out carefully copper/aluminium point wiring,Light,fan,socket or power complete with all fitting, fixtures such as switch socket out let, ceiling rose ,holder ,regulator,DBs etc including making good the disturbed surface of wall/floors complete
Taking down existing unserviceable submain wiring any size and making good the disturbed surface all as specified and as directed.
M&L for point wiring for one light point/fan point/bell point controlled by one way switch with 1.5 Sqmm FRLS PVC insulated, unsheathed, single core, multi-stranded copper conductor cable, 1100 Volts grade, drawn through and including concealed rigid PVC conduit (medium grade) of suitable dia, with 1.5 Sqmm FRLS copper conductor cable as earth continuity wire connected to common earth dolly, terminated in and including Piano type pressed GI sunken box (wall thickness not less than 1.22 mm up to 200×300 mm and 1.63 mm for larger sizes) with 3 mm thick hylum sheet including cutting chases, making good disturbed surfaces with cement mortar (1:3), finishing to match existing surface and testing on completion, all as specified and directed.
All as per item no-109 above but for one Exhaust fan point controled by one piano switch all as directed.
All as per ser item No 109 hereinbefore but for one 3 pin socket outlet 5 Amp Same Board
All as per ser item No 109 hereinbefore but for one 3 pin socket outlet 5 Amp independent Board
All as per Item no 109 here-in-before but for one15 Amp 3pin switch socket outlet, independent with 2.5 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
S&F in replacement of piano type switch one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz complete all as specified.
S&F in replacement of piano type socket outlet flush type, 5 pin, 5/6 Amps, 230 volts AC, 50 Hz, multipurpose type complete all as specified.
S&F in replacement of piano type switch socket combination flush type, 3 pin 5/6 Amps, 230 volts AC, 50 Hz, multipurpose type complete all as specified.
S&F in replacement of piano type switch socket combination 5 pin, 5/15 Amps, 230 volts AC, 50 Hz, multipurpose type complete all as specified.
Supply and fix of Ceiling rose surface bakelite three terminals 240 volts complete, all as specified.
Supply and fix of Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings , all as specified.
S&F in replacement of electronic type ceiling fan dimmer, 230 volts, single phase, flush type complete all as specified.
Supply and fixing of industrial plug and socket set of capacity 20A, 230V, 1P+N+E, IP-44/IP-55 protection, complete with heavy-duty industrial grade enclosure, interlocked switch mechanism, suitable for wall mounting, including all necessary fixing hardware and making good disturbed surfaces. The unit shall be factory-made, IS/IEC compliant complete all as specified and as directed .
Supply and fix in repair LED lamp,6500K,900lm in white colour of 9 Watt base cap B-22 with poly carbonate difusser and aluminium heat sink ,complete all as specified & directed. Make: Halonix/Philips or equivalent.
S&F in replacement LED tube light fitting 20 watts, 220 volts AC ,6500K Colour temp, length 4 ft appx, with aluminium housing & integrated electronic driver complete with driver with polycarbonate diffuser & thd< 10% including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose complete all as specified.
S&F bulk head light fitting LED 10 Watt, 230 Volts, IP65 weather proof, energy efficient, die-cast aluminium body with polycarbonate diffuser, complete with necessary terminal block, gasket, hardware and connection with flexible copper conductor cable including fixing on wall/ceiling with suitable screws and rawl plugs all as specified and directed.
Supply and fix IP 66 Integral LED security light luminaire 35 W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & heat resistant toughned glass ,efficacy 110 lumens/watt, external 10KV,440 volt SPD and inbuilt 4KV , IP 67 potted isolated driver with operating range 902V to 340V AC .CCT 5700K,LED life -1 lakh burning hours,fixture should withstand 320 volt upto 48 hrs , Auto cut off >320 volts & restart,440 Volt sustain upto 8 hrs,NABL Acreddited LM79 report including GI pipe 40mm ,medium grade ,1.7mtr long mounting bracket and providing fixing clamps ,bolts,nuts of suitable size complete all as specified and as directed.
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4 sqmm and one single core PVC insulated (unsheathed) solid copper conductor FRLS cable of size 4 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement moter 1:3 and making good disturbed surface complete all as specified and as directed. (For Metal Clad)
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 6 sqmm and one single core PVC insulated (unsheathed) solid copper conductor FRLS cable of size 6 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement moter 1:3 and making good disturbed surface complete all as specified and as directed. (from TPN to SPN)
S&F exhaust fan made of sturdy Engineering plastic 300 mm sweep, 230 V, complete with blades, frame, louver/shutter and all standard accessories, including cutting of wall to required size, fixing the fan in position with proper mounting arrangement, making connections, and making good the disturbed wall surface with cement mortar/finishing to match the existing surface, testing and commissioning, all as specified and directed. (For Washroom)
S&F exhaust fan steal body of 450 mm sweep, 230 V, complete with blades, frame, louver/shutter and all standard accessories, including cutting of wall to required size, fixing the fan in position with proper mounting arrangement, making connections, and making good the disturbed wall surface with cement mortar/finishing to match the existing surface, testing and commissioning, all as specified and directed. (For Kitchen)
S&F TPN vertical type distribution board, 4-way, double door, 415 Volts, IP43 protection, powder-coated sheet-steel enclosure, factory-wired for three phase and neutral, complete with 200 Amps rated busbar, designed for flush mounting (fixed into wall), including cutting of wall, embedding the DB in position, reinstating the surface with cement mortar, and making necessary connections with copper conductor cable, all as specified and directed.
Supply, installation, connection, testing of TPN MCB of capacity 63 Amps, 10kA, 415V, 4-pole, B-curve (or as specified), fixed in suitable sheet-metal enclosure, including necessary interconnections, fixing hardware, thimbles/lugs and making good the disturbed surfaces, all as specified and as directed by Engineer-in-Charge
S&F SPN distribution board, 8-way, double door, 240 Volts, IP43 protection, powder-coated sheet-steel enclosure, factory wired for single phase and neutral, complete with 200 Amps rated busbar, suitable for incoming MCB/Isolator up to 63 Amps and outgoing MCBs as required, designed for flush mounting (fixed into wall), including cutting of wall, embedding the DB, reinstating the wall surface with cement mortar, and making necessary connections with copper conductor cable, all as specified and directed
S&F MCB SP of rating 6 to 32 Amps, 240 Volts, 10 kA breaking capacity, B-curve, ISI marked, conforming to IS/IEC 60898, fixed in DB with necessary connections, testing on completion, all as specified and directed
S&F SPN MCB 40-63 Amps, 240 Volts, 10 kA breaking capacity, B-curve, ISI marked, conforming to IS/IEC 60898, fixed in DB with necessary connections and testing on completion, all as specified and directed
Earthing complete with galvanized mild steel earth plate electrode size 600x600x6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 part-I, connected to test point complete, all as specified and testing on completion. (For TPN DB)
Supply, laying or passing through pipe LT underground cable, PVC sheathed, XLPE insulated, armoured, 1100 volts grade, aluminium conductor of size 35 Sqmm, 3.5 core, including laying in excavated trench, fixing on wall using suitable MS clamps where required, passing through GI/PVC pipe at road crossings or building entries, making electrical connections with thimbles, testing and commissioning, complete all as specified. (For Bldg P-409 & P 410 Incomer to LT Panel)
Supply, laying or passing through pipe LT underground cable, PVC sheathed, XLPE insulated, armoured, 1100 volts grade, aluminium conductor of size 25 Sqmm, 4 core, including laying in excavated trench, fixing on wall using suitable MS clamps where required, passing through GI/PVC pipe at road crossings or building entries, making electrical connections with thimbles, testing and commissioning, complete all as specified. (For P-409, P-410 & T-165)
M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable all as specified. Note: Punned thickness of sand shall be measured & paid.
M&L for well burnt sub class 'B' bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified.
Supplying and laying GI tubing light grade of size 40 mm bore for cable protection, fixed on wall/structure with suitable MS clamps and spacers at required intervals, including all fittings and accessories, complete all as specified. For cable Protection
M&L for Earthing complete with GI earth plate 600 x 600 x 6 mm thick buried directly in ground (earth pit not less that 2.25mtr deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 25x4 mm GI strip as earthing lead by means of brazing after tighten by bolts, nuts, check nuts and washers from earth pit to test point with protection GI pipe of size 50mm dia light grade and providing masonry enclosure including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil, complete all as specified and as directed. Note:- GI strip 7.5 mtr included in the quoted rate from earth pit to test point
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
tender95_merged.pdf
Tender Documents • 1.90 MB
BOQ_847395.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .