Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.3 LAccepted-AOC ASHOK VIHAR PHASE II BHIM GARH KHERI GALI NO 16A 355 85 GURGAON 122001 | GURGAON | GURUGRAM | HARYANA | 122001 | ₹49.3 L | L1 | Accepted-AOC Awarding process closing on portal |
| 2 | L2₹64.3 LRejected-Finance | ₹64.3 L | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | FREEZEOTECH AIRCONDITIONING & REFRIGERATION CORPORATION L2 | Mark Engineering Inc. L1 |
|---|---|---|---|---|---|
| 1.00 | Providing and Fixing 1Ton, 5 Star Rating of Inverter Split Type Air Conditioners (as per approved make) complete with indoor unit (IDU), Outdoor unit (ODU) both in copper coil/ Condenser, surface / concealed copper Refrigerant piping with insulation (EP Foam pipe section) up to 3 Mtr. (IDU to ODU) copper power cable up to 3 Mtr. (at least 3CX 2.5 Sqmm, PVC Insulation, FRLS copper wire) (IDU to ODU), R-32/R-410A Refrigerant , PVC drain pipe (dia 15mm-20 mm) Remote with batteries, suitable for 230V +10% of 50 Hz, Single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll/ reciprocating/ rotary compressor including wall mount stand for ODU | 17 | Each | 47,808 ₹8,12,736 | 40,200 ₹6,83,400 |
| 2.00 | Providing and Fixing 1.5 Ton, 5 Star Rating of Inverter Split Type Air Conditioners (as per approved make) complete with indoor unit (IDU), Outdoor unit (ODU) both in copper coil/ Condenser, surface / concealed copper Refrigerant piping with insulation (EP Foam pipe section) up to 3 Mtr. (IDU to ODU) copper power cable up to 3 Mtr. (at least 3CX 2.5 Sqmm, PVC Insulation, FRLS copper wire) (IDU to ODU), R-32/R-410A Refrigerant , PVC drain pipe (dia 15mm-20 mm) Remote with batteries, suitable for 230V +10% of 50 Hz, Single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll/ reciprocating/ rotary compressor including wall mount stand for ODU | 74 | Each | 54,834 ₹40,57,716 | 45,600 ₹33,74,400 |
| 3.00 | Providing and fixing extra copper piping along with insulation for 1.5 and 1.0 ton AC (size of pipe same as per manufacturer) of approved make. | 500 | RMT | 1,531 ₹7,65,500 | 800 ₹4,00,000 |
| 4.00 | Providing and fixing Stabilizer (240V, 50 HZ, 2.5 KVA), including 16 Amp 3 pin top, 25 Amp. DP MCB with MS Enclosure as per approved make. | 17 | Nos | 4,300 ₹73,100 | 3,000 ₹51,000 |
| 5.00 | Providing and fixing Stabilizer (240V, 50 HZ, 4 KVA), including 16 Amp 3 pin top, 32 Amp. DP MCB with MS Enclosure as per approved make. | 74 | Nos | 4,476 ₹3,31,224 | 3,000 ₹2,22,000 |
| 6.00 | Providing & fixing extra copper cable (3x2.5 sq mm) of approved make. | 300 | rmt | 616 ₹1,84,800 | 180 ₹54,000 |
| 7.00 | Design, Supply and laying of additional ¾ inch. (20mm) dia of HDPE PVC drain pipe with necessary fixing material. | 950 | RMT | 213 ₹2,02,350 | 150 ₹1,42,500 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
10 Feb 2023, 5:00 pmClosed
Registrar
CRSU, Jind
SITC SUPPLY and INSTALLATION OF SPLIT AIR CONDITIONER ALONGWITH STABILIZER AT CHAUDHARY RANBIR SINGH UNIVERSITY, JIND
2023_HRY_253842_1
1-split
Open Tender
Miscellaneous Goods
30 days
Jind
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
Yes
₹1 L
Yes
26 May 2026
16 Jan 2023
13 Feb 2023
16 Jan 2023
10 Feb 2023
16 Jan 2023
Amount
Providing and Fixing 1Ton, 5 Star Rating of Inverter Split Type Air Conditioners (as per approved make) complete with indoor unit (IDU), Outdoor unit (ODU) both in copper coil/ Condenser, surface / concealed copper Refrigerant piping with insulation (EP Foam pipe section) up to 3 Mtr. (IDU to ODU) copper power cable up to 3 Mtr. (at least 3CX 2.5 Sqmm, PVC Insulation, FRLS copper wire) (IDU to ODU), R-32/R-410A Refrigerant , PVC drain pipe (dia 15mm-20 mm) Remote with batteries, suitable for 230V +10% of 50 Hz, Single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll/ reciprocating/ rotary compressor including wall mount stand for ODU
Providing and Fixing 1.5 Ton, 5 Star Rating of Inverter Split Type Air Conditioners (as per approved make) complete with indoor unit (IDU), Outdoor unit (ODU) both in copper coil/ Condenser, surface / concealed copper Refrigerant piping with insulation (EP Foam pipe section) up to 3 Mtr. (IDU to ODU) copper power cable up to 3 Mtr. (at least 3CX 2.5 Sqmm, PVC Insulation, FRLS copper wire) (IDU to ODU), R-32/R-410A Refrigerant , PVC drain pipe (dia 15mm-20 mm) Remote with batteries, suitable for 230V +10% of 50 Hz, Single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll/ reciprocating/ rotary compressor including wall mount stand for ODU
Providing and fixing extra copper piping along with insulation for 1.5 and 1.0 ton AC (size of pipe same as per manufacturer) of approved make.
Providing and fixing Stabilizer (240V, 50 HZ, 2.5 KVA), including 16 Amp 3 pin top, 25 Amp. DP MCB with MS Enclosure as per approved make.
Providing and fixing Stabilizer (240V, 50 HZ, 4 KVA), including 16 Amp 3 pin top, 32 Amp. DP MCB with MS Enclosure as per approved make.
Providing & fixing extra copper cable (3x2.5 sq mm) of approved make.
Design, Supply and laying of additional ¾ inch. (20mm) dia of HDPE PVC drain pipe with necessary fixing material.
FREEZEOTECH AIRCONDITIONING & REFRIGERATION CORPORATION
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid