| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹9.5 L+₹2.5 L (35.0%)Rejected-AOC D 35 1ST FLOOR CLOCK TOWER HARI NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L2 | Rejected-AOC Other than lowest | |
| 3 | L3₹9.6 L+₹2.6 L (36.8%)Rejected-AOC NA | NA | NA | 121004 | L3 | Rejected-AOC Other than lowest bidder |
Tender Value
₹9.8 L
EMD Value
₹19,696
Closing Date
30 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I CG
Noida
PROVISION OF TOILETS BLOCK AT RDG GROUND AT SECTOR 24 NOIDA
2021_MES_456651_1
AGE I CGN 05 2021-22
Open Tender
Civil Works
Item Rate
240 days
Noida
E a i
7 documents required · 7 mandatory
₹500
AGE I CG
₹19,696
25 Mar 2022
3 Jul 2021
2 Aug 2021
3 Jul 2021
30 Jul 2021
16 Jul 2021
60 days
Amount
Surface dressing n.exc 15cm deep in soft/loose soil complete
Excavation in trenches, exc 1.5m wide and nexc 1.5m in depth for foundation etc n.exc 10 sqm on plan and nexc 1.5mtr in depth and getting out in soft/loose soil complete.
Removing excavated soil n.exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete
Retruning, filling in, including spreading, levelling watering and well ramming in layers not exc 25cm in soft/loose soil.
M&L for Broken bricks hardcore of gauge n exc 63 mm, deposited, spread and level in layers n exc 15 cm thick, watered and rammed to a true surface complete
M&L for Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling as mass concrete complete all as specified.
M&L for Cement Concrete B0 1:2:4 (12.5 mm graded aggreage) in copings or brick step, cills and roof kerbs etc complete.
M&L 75mm thick Plain cement concrete D2 1:4:8 (using 40mm graded stone aggregate as sub base of floors or foundations complete all as specified.
Filling, spreading and levelling under floor excavated earth in layers not exc 15cm watered and rammed to a true surface complete.
M&L 75mm thick Plain cment concrete B-1 1:2:4 (using 20mm graded stone aggregate as plinth protection finish surface fair and even without using extra cement complete all as specified.
M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement motar 1:6. complete all as specified and directed.
M&L for brick work with sub class ‘B’ old size straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
Formwork to sides of concrete foundations, footings, beses of columns, of foundation and plinth beam and similar work vertical or to batter for rough finished.complete
Formwork to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exceeding 200mm thick for fair finished.
Formwork to soffits and sides of lintel beams or roof beams etc for fair finished.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc for fair finished.
Formwork to chajjas, troughs and similar items inclding edges for fair finished.
Formwork to edges of concrete flats, treads breaks in floors, window cills, concrete railing, and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n.ec 20cm wide for fair finished
M&L treating the backfill in contact with foundation at the rate of 7.5 lites of emulsion per sqm of vertical surface (Area of the sub strature in contact with backfill to be measured).
M&L treating the top surface of filled earth at the rate of 5 ltrs of emuslion per sqm of surface.
M&L treating the soil under plinth protection at rate of 5 ltrs of emulsion per sqm of surface.
M&L for providing and injecting chemical emulsion antitermite treatment along the external perimeter of building @ 2.25ltrs emulsion per meter of the perimeter wall complete.
M&L for Reinforced cement concreteM-25 Design mix (20mm graded aggregates) in foundations, including rafts, plinth beams footings foundation, basement slabs.
M&L for Reinforced cement concreteM-25 Design mix (20mm graded aggregates) in Beams, cantilevers.
M&L for Reinforced cement concreteM-25 (20mm graded aggregates) in columns, pillars
M&L for Reinforced cement concreteM-25 Design mix (20mm graded aggregates) in Slabs supported on walls, beams and columns in floor, roofs, landings, balconies, canopies,deck slabs and in shelves and the like.
M&L for Reinforced cement concreteM-25 Design mix (20mm graded aggregates) in chajjas.
M&L for providing precast cement cocrete Type B1, 1:2:4 (20mm graded aggregate) in window or door cills, lintels, bressumers steps, quoin blocks etc and setting in cement 1:4 mortar complete with joints to match.
S&F for TMT bar 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ands and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia or securing with clips.
All as per above but 6 mm to 8mm dia complete.
All as per above but 5mm dia and over upto and incl 10mm dia in stirrups, apacers and binders
M&L for light shade vitrified ceramic digital tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors complete.
M&L for 300x 600mm x 10mm thick Glazed coloured ceramic digital tiles in pattern or concept set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over complete all as specified & directed.
M&L for 15mm thick Screed bed or beeding layer of mortar in CM 1:6 for laying floor finishes complete.
M&L for 10mm thick rendering for backing of tiles in CM 1:3 on fair faces of brick work or concrete surfaces.
M&L for 20mm thick Screed bed or beeding layer of mortar in CM 1:6 for laying floor finishes complete.
M&L for 20mm thick Granite (red rubby or as approved ) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with sahde of granite complete
Rounding to edges of stone slab one edge, such as steps, cooking platform and other similar situations and rubbing and polishing complete
M&L for powder coated (min 50 micron powder coating ) anodised aluminium frame, shutters for doors, windows, ventilators with one or more rebates incl joining cleat for fixing etc complete all as specified
S&F 5.5mm thick sheet glass ordinary quality and glazing in square n exc 0.5 sqm in each pane
S&F 1000 ltr capacity HDPE water storage tank, cylinderical vertical with closed top, having three layers, with over all thickness as per IS with locking arrangements hoisted and fixed in position complete all as specified and directed in SSR Part-II.
Cutting chases in brick walls, pining in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting exc 10 cm but not exc 20 cm girth complete
S&F CPVC pipe SDR-11, 20 mm bore with plain SDR-11 fittings complete to walls and ceilings or laid floors or concealed,( cost for cutting chases in wall/ceiling for concealing tube shall be measured seperately) complete all as specified and directed.
S&F CPVC pipe SDR-11, 25 mm bore with plain SDR-11 fittings complete to walls and ceilings or laid floors or concealed,( cost for cutting chases in wall/ceiling for concealing tube shall be measured seperately) complete all as specified and directed.
S&F 20mm/25mm CPVC Male or female Brass Threaded Adapter (Make Supreme/Prince/Astral)
S&F 15mm/20mm CPVC Male or female Brass Threaded Adapter (Make Supreme/Prince/Astral)
S&F 25mm CPVC tank nipple/adaptor (Make Supreme/Prince/Astral)
S&F in repairs Brass metal globe or gate valves, with wheel/handle head, screwed both ends for iron pipe 25 mm bore complete all as specified and directed. (Make Zoloto/
S&F ball brass valves, high pressure, with polythene float and fly nut, screwed for iron pipe or brass ferrule 25 mm bore complete all as specified and directed. (prayag Cat No I-152 Complete set)
S&F PVC (SWR) 110mm dia pipes single socketed, in any length with rubber joints, fixed to walls with clamps complete.
S&F PVC (SWR) 110mm dia pipes single socketed, in any length with rubber joints, laid in trenches or in floors
S&F PVC (SWR) 110mm bends fixed to be complete.
S&F PVC (SWR) 110mm Tee fixed to be complete.
S&F PVC (SWR) 75mm dia pipes single socketed, in any length with rubber joints, laid in trenches or in floorss complete.
S&F PVC (SWR) 75mm dia pipes single socketed, in any length with rubber joints, fixed to walls with clamps complete.
S&F PVC (SWR) 75mm bends fixed to be complete.
S&F PVC (SWR) 75mm Tee fixed to be complete.
M&L for rendering 10mm thick in CM 1:4 over RCC roof mixed with WPC finished even and smooth without using extra cement complete.
Supply only liquid WPC. Make : Fosroc Conplast/Sika
M&L for 40mm thick brick tiles laid, and joints grouted flush in cement mortar (1:3) mixed with 5% of curde oil by weight of cement and pointing of joints with CM 1:2 complete
M&L for water proofing treatment to RCC roof slab incl parapet as under (a) Applying bituminious primer conforming IS 3384 1965 @ 0.50 Kg/Sqm over cleaned and dry roof surface incl parapet. (b) Applying hot blown grade 85/25 bitumen as per IS 702-1988 A 1.2 Kg/Sqm applied over primer. (c) Laying one layer of APP based polymeric membrane, 3mm thick, weight not less than 3.6 Kg/Sqm reinforced with non woven polyster fiber reinforced (wight not less than 150gm/Sqm) sealed by torch application with a minimum overlap of 100mm and 75mm at end and side of polymeric membrane (d) Alayer of hot blown bitumen grade 85/25 @ 1.20 Kg/Sqm over APP. all as specified and as directed by Engrineer-in-charge.
S&F Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms)
S&F 75mm dia PVC (SWR) vent cowl
S & F Stack clamps for 110mm dia pipe made out of 50 mm by 5 mm flat iron and 16 mm dia around iron stays including bolt and nuts for securing ends of stays to walls or roofs, bore pipe 100 mm dia pipe complete all as directed.
S & F Stack clamps for 75mm dia pipe made out of 50 mm by 5 mm flat iron and 16 mm dia around iron stays including bolt and nuts for securing ends of stays to walls or roofs, bore pipe 100 mm dia pipe complete all as directed.
M&L rendering 15mm thick in cement motor 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
M&L for 5mm thick rendering in CM 1:3 on ceiling surfaces and finished even and smooth without using extra cement complete
Rendering 15 mm thick cement plaster on external surfaces of brick work in CM 1:4 to be mixed with WPC including finishing even and smooth (WPC will be measured and paid separately).
M&L for Preparing of new plastered surface and applying three coat of white wash on newly plastered surface of ceiling
M & L for Preparing new plastered or unplastered surfaces of wall and M & L applying two coats of exterior emulsion paint of Make : weather coat of Berger/ apex ultima of Asian paints/Xtrapremium of Shalimar, over and incl of a coat of exterior wall primer as approved by manufacturer.
M & L for Preparing new plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including one coat of Birla Putty complete all as specified and directed.
Supply and fixing vitreous china wash down water closet pan wall mounted complete single unit including double syphonic flusing cistern white, seat cover including connection to drain trap complete. all as specified and directed. Make : (Parryware Model : Verve, white, C0269 closet including soft close seat covers, C0762 cistern set including fittings) or (Jaquar KUS WHT 35851SN)
S&F vitreous china white wash basins, incl waste pipe, brackets, and connecting pipe (Make Jaquar KUS WHT 35901 Table top basinKerovit Mazer KB1086 or equivalent
S&F in repairs vitreous china urnials half stall type incl connecting pipe, spreader, flushing valve and flush/waste pipe fixed to wall complete. Make : Parryware C0580 with C8123 or Jaguar URS WHT 132530
S&F health faucet cast copper alloy chromium plated with flexible chrome hose and wall hooks complete (Make Jaguar ALD 573 or parryware T9941A1
S&F cast copper alloy chromium plated bottle trap fixed to WHB and wall complete. Make Parryware T3201A1 or equivalent
S&F stop cock chormium plated fixed to 15 mm dia MS pipe complete (Make parryware G0253A1)
S&F 2 way cast copper alloy chromium plated 15mm bib tap with wall flange fixed to pipe complete (Make Jaquar ARI 39041 or Parryware G3334A1)
S&F Bib cock with wall flange 15mm fixed to pipe. Make : Jaquar KUP-35037PM or Kerovit KB411004
S&F toilet paper holder with cover fixed to walls with chormium plated bracs screws complete. Make parryware T6514A1 or jaquar ACN1153N
S&F Towel Rail fixed to wall with chromium plated braces screws complete (Make Parryware T6501A1 or jaquar CAN 1101N)
S&F concealed stop/flush cock fixed to pipe complete. Make : Parryware T3040A1 Pebble
S&F in repairs 600mm long PVC connection pipe fixed to 15mm dia pipe complete
S&F 12 mm thick thoughned frosted Glass doors with necessary stainless steel fixing patches and lock latches fixed complete .
S&F 600mm long Stainless steel AISI 316 Door handles fixed to toughned glass door complete (Make Kich PHN 32 x 10mm)
S&F double action floor spring hydraulically regulated made up of min 1.25mm thick aluminium alloy sheet foundation box main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed with door complete
S&F CU(corner unit) Toilet block cubical made of HPL 12.00mm thick boards of colour or textured surface as approved by Engr-in-charge of size 1000x1500x1995mm, door size of 600x1785mm with 150mm ground clearance incl necessary hardware (aluminium U/F channel, Aluminium top rail, stainless steel gravity hinges, alloy privacy tumb-turn with indictor, SS coat hook cum door stopper, SS door knob, SS adjutable foot, polyamide top rail end cap and aluminium door stopper channel etc) complete all as specified and directed by Engr in charge (Make Greenlam Model Classique Versatile
S&F EU(Enclosed unit) Toilet block cubical made of HPL 12.00mm thick boards of colour or textured surface as approved by Engr-in-charge of size 1000x1500x1995mm, door size of 600x1785mm with 150mm ground clearance incl necessary hardware (aluminium U/F channel, Aluminium top rail, stainless steel gravity hinges, alloy privacy tumb-turn with indictor, SS coat hook cum door stopper, SS door knob, SS adjutable foot, polyamide top rail end cap and aluminium door stopper channel etc) complete all as specified and directed by Engr in charge (Make Greenlam Model Classique Versatile
S&F curved shaped 8mm thick frosted glass urinal partition of size 900x 450mm (Make Jaguar JSE-CHR-810UC 450X) incl necessary SS clamp and bottom support to fixed on wall and floor complete as specified.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete
M&L 100mm thick Plain cment concrete C2, 1:3:6 (using 40mm graded stone aggregate as sub base of floors or foundations complete all as specified.
M&L for sand filling under floor in foundations inclding watering and consolidation complete.
M&L for pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658-2006 of 60 mm thickness,M-35 grade laying in floors complete.
Cutting holes (N exc 150 sq. cm) into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required
M&L for Plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation filling as mass concrete or in sub base of floors complete all as specified.
M&L for brick work in cement mortar 1:6 using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6 metre mean radius complete all as specified.
S&F for TMT bar 8mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ands and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia or securing with clips.
S & F Reinforced concrete pipes, class NP3, laid and jointed complete with collars as per engg-in-charge
M & L for Concrete bed, cement concrete 1:3:6 type C-2 to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in
M&L for 15 mm thick rendering in CM 1:4 on fair faces of brick work or concrete surface and finished even and smooth without using extra cement complete.
Supply only liquid water proofing compound (Make : Fosroc Conplast/Nitoband SBR / Dr Fixit LW+)
M & L for cement concrete (Type B0, 1:2:4, 12.5 mm graded aggregate) in copings, kneelers, apex stones, bed plates, water troughts and the like including weathering, slightly rounded or chamfered angles and throating, as directed
M & L for precast cement concrete (Type B-1, 1:2:4, 20 mm graded aggregate)in landings, cover slabs (for manholes etc.) or as per engg-in-charge
Sand cusioning for PVC cable with screened & washed sand & punning to provide a required cover.
M & L for providing old size sub class 'B' bricks laid perpendicular to the cable abutting each other all as specified and directed.
Supply,laying, connecting and testing cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section of 10 sqmm 2 core laid in trenches/ walls/ ducts/ passing through pipe etc complete all as specified and directed. Make Polycab/ Havells/ Gloster
S & F GI pipe in trenches,fixed on wall/pole light grade of size 40 mm dia including necessary fittings all as directed.
Earthing complete with galvanized steel earth plate electrode 60cm x60cm x6.00 mm thick, buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate not less 1.5 mtr below normal ground level , filled around with layer of charcoal dust and salt and connected to earth lead wire 4mm dia (8 SWG) by means of bolt, nut and check nuts and washers of galvanized iron or steel and thimble and other ends of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm bore and watering pipe 20mm dia light grade with funnel and wire mesh, PCC 1:3:6 in chambers, RCC 1:2:4 in pit cover reinforced with 8mm dia deformed bars @ 15cm centre to centre both ways including necessary excavation & earth work as directed by engineer –in-charge, complete all as shown in electric plate No-5 of MES Sch part 1 of 1991.PCC chamber shall be constructed at least 1.5 mtr away form the earth electrode and pipe for watering.
S & F Steel water Tubing Med Grade with all fixing accessories complete fixed to wall or ceiling or laid on ground complete all as directed for size of 25 mm dia.
M&L for cutting existing steel tubing for alterations or additions (Each cut measured) for 25 mm to 32 mm bore tubing, complete all as specified and directed.
S & F gate valves (Gun metal globe valve) with iron wheel head, screwed both ends for iron pipe and fixed for 20mm dia, complete all as specified and directed. Make : SCUD/SHAKTI/LEADER/ ZOLOTO
M & L Point wiring with single core PVC insulated unsheated 1100 Volts grade FRLS cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area) drawn through and incl non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia,fixed on wall (concealed conduit wiring) and on ceiling with GI saddles,GI screws,rawl plugs etc (surface conduit wiring) with all fittings incl tee,junction boxes and provn of pressed steel terminal box 2mm thick of suitable size with 3mm thick plastic laminated sheet cover for mounting switch sockets and regulators/ modular type pressed steel terminal boxes of suitable sizes for modular wiring with PVC white fram where modular switch socket to be fixed/coloured top sheet cover/ frame and drawing continious earth wire and incl PVC insulated unsheated 1100 Volts grade FR IS 694 cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area) connected to earth for Light and fan/Exhaust Fan Point dolly complete all as specified and directed by Engr-in-charge.
All as per item No-2 above for Point wiring with single core PVC insulated unsheated 1100 Volts grade FRLS cable with multi stranded copper conductor of size 2.5 sqmm (Nominal area) incl earth wire PVC insulated unsheated 1100 Volts grade FR IS 694 cable with multi stranded copper conductor of size 2.5 sqmm (Nominal area) connected to earth dolly all as specified for 3 pin 15 amp socket outlet point controlled by one switch on independent board complete all as specified and as directed by Engr-in-charge.
S & F switch piano, flush type, single pole, one way 6 amp complete all as specified and directed by Engineer-in-charge.
S & F switch piano, flush type, single pole, one way 16 amp complete all as specified and directed by Engineer-in-charge.
S & F socket outlet 2 in 1, 5 pin, 16 amp flush type complete all as specified and directed by Engineer-in-charge.
Supply and fix ceiling rose surface bekalite 3 terminals 65mm x 50mm complete all as specified.
S&F Tube light ceiling/ wall mounted LED batten 20W with Aluminium/PVC housing, intigrated Electronic driver including connecting up with suitable length & size twin core twisted flexbile copper conductor cable complete all as specified and directed by Engineer-in-charge. Make : Havells Lumiline Plus or other equivalent in Philips/Wipra
M & L in replacement surface mounted round LED downlighter 15 Watt with powder coated aluminium housing with integrated electronic driver. Make Havells cat No ENDURANEOSURFACEDLS15WLED857S or Equvallant in philips /Wipra
M & L in replacemet Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of high brightness LEDs IP66, 10 Watt. Make : Havells Hexa 10W Cat Pt No HEXAFT10WLED857SSYMBOPC OR equvailent makes of Philips / Wipro etc
S&F MCB 6-32 Amp SPN 240 volt AC supply rupturing capacity not less than C series 10 KA complete all as specified and directed by Engineer-in-charge. Make : Havells Cat part No - DHMCGCSNF006-032 or of equivalent in L & T /Legrand
S&F MCB 10 to 32 Amp SP 240 volt AC supply rupturing capacity not less than C series 10 KA complete all as specified and directed by Engineer-in-charge. Make : Havells Cat part No -DHMCGCSPF006-032 or of equivalent in Havells/ L&T /Legrand
S & F sheet metal enclosure for MCB, DBs single pole and neutral 4 way with 200 Amp rated bus bar, 240 volt complete all as specified and directed by Engineer-in-charge. Make : Havells/ L&T /Legrand
S&F exhaust fan, single phase, heavey duty PVC frame 300 mm sweep, 1400 RPM including fixing of mounting frame in the round hole cutting in the wall by means of rugged bolts, nuts and washers etc including three core copper conducttor flexible cord of 0.5 sqmm cross sectional area of requred length form ceilling rose to the porcelain connnector block of exhasut fan completed all as specified and directed Make : Heavells /Bajaj CG"
M/s Navansh Engineers & Consultants
M/s Sagar Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .