Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.7 LAccepted-AOC 42 11 DIPKA PALI ROAD DIPKA DIPKA KORBA CHHATTISGARH 495452 UDYAM CG 10 0007210 | KORBA | CHHATTISGARH | 495452 | ₹1.7 L Quoted ₹1.5 L | L-1 | Accepted-AOC Accepted as the bidder attains L-1 status |
| 2 | L-2₹1.7 LRejected-Finance 0 GOPAL GANJ CHABUTRA KE SAMNE PRATAPGARH PRATAPGARH PRATAPGARH RAJASTHAN 312605 UDYAM RJ 27 0002563 | PRATAPGARH | RAJASTHAN | 312605 | ₹1.7 L | L-2 | Rejected-Finance Rejected as the bidder attains L-2 status |
| Sl No | Description | Qty | Unit | V R ENTERPRISES L2 | SHASHI BHUSHAN SINGH L1 |
|---|---|---|---|---|---|
| 1.00 | Trimming of tree branches under the over head line conductor and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared, etc. as required (Trimming of tree branches required for about 7 KM out of approx 12 KM OH line) | 7 | Km | 900 ₹6,300 | 3,200 ₹22,400 |
| 2.00 | Erection/ replacement of damaged 10/ 11/13 mtr. long steel tubular poles including excavation of pole pit as per site conditions and grouting by cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) etc (0.38 cum each pole) | 12 | No. | 2,100 ₹25,200 | 1,200 ₹14,400 |
| 3.00 | Erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm X 600 mm), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (Stay wire shall be provided by the contractor) | 15 | No. | 1,550 ₹23,250 | 1,100 ₹16,500 |
| 4.00 | Stringing of Dog conductor (all 3 Nos. conductor), including un-coiling from drum at stockyard, loading onto departmental vehicle, transporting to site and unloading, laying of conductor along route, stringing and binding on insulators and jumpering etc. as required. | 0.5 | Km | 8,900 ₹4,450 | 4,000 ₹2,000 |
| 5.00 | Stringing of conductor Rabbit conductor (all 3 Nos. conductor), including un-coiling from drum at stockyard, loading onto departmental vehicle, transporting to site and unloading, laying of conductor along route, stringing and binding on insulators and jumpering etc. as required. | 1 | Km | 6,000 ₹6,000 | 2,000 ₹2,000 |
| 6.00 | Laying & stringing of 8 SWG GI wire earth | 200 | Kg | 60 ₹12,000 | 35 ₹7,000 |
| 7.00 | Fabrication of MS Channel/Angle/Flat for bracket or clamp as per requirement. | 250 | Kg | 8 ₹2,000 | 6 ₹1,500 |
| 8.00 | Supplying and fixing of MS nut, bolt of different size as required | 35 | Kg | 90 ₹3,150 | 90 ₹3,150 |
| 9.00 | Erection of cradle guarding wire between the span including binding of guard wire. | 8 | Span | 1,400 ₹11,200 | 650 ₹5,200 |
| 10.00 | Providing & erection of Pin insulator (100 mm X 80 mm) with G.I. spindle and nuts, 1.1 KV grade | 24 | No. | 200 ₹4,800 | 80 ₹1,920 |
Updated dates
Tender Value
₹4.1 L
EMD Value
₹5,100
Closing Date
6 Mar 2026, 5:00 pmClosed
Staff Officer (EnM)
Office of the General Manager, Dipka Area, Ph. No. 9424141353
Pre-monsoon/preventive maintenance of HT / LT / lighting overhead line of Surface power supply section of Dipka Expansion Project (Route length - about 12 KM).
2026_SECL_353462_1
SECL/GM/DA/SO(EnM)/ e-tender/25-26/129 dtd-17/02/26
Open Tender
Electrical and Maintenance Works
40 days
Dipka Expansion Project, Dipka Area
Please refer to tender documents
5 documents required · 5 mandatory
₹5,100
10 Apr 2026
18 Feb 2026
9 Mar 2026
18 Feb 2026
6 Mar 2026
19 Feb 2026
18 Feb 2026 - 25 Feb 2026
Trimming of tree branches under the over head line conductor and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared, etc. as required (Trimming of tree branches required for about 7 KM out of approx 12 KM OH line)
Erection/ replacement of damaged 10/ 11/13 mtr. long steel tubular poles including excavation of pole pit as per site conditions and grouting by cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) etc (0.38 cum each pole)
Erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm X 600 mm), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (Stay wire shall be provided by the contractor)
Stringing of Dog conductor (all 3 Nos. conductor), including un-coiling from drum at stockyard, loading onto departmental vehicle, transporting to site and unloading, laying of conductor along route, stringing and binding on insulators and jumpering etc. as required.
Stringing of conductor Rabbit conductor (all 3 Nos. conductor), including un-coiling from drum at stockyard, loading onto departmental vehicle, transporting to site and unloading, laying of conductor along route, stringing and binding on insulators and jumpering etc. as required.
Laying & stringing of 8 SWG GI wire earth
Fabrication of MS Channel/Angle/Flat for bracket or clamp as per requirement.
Supplying and fixing of MS nut, bolt of different size as required
Erection of cradle guarding wire between the span including binding of guard wire.
Providing & erection of Pin insulator (100 mm X 80 mm) with G.I. spindle and nuts, 1.1 KV grade
Providing & erection of shackle insulator for 1.1 KV grade for overhead lines as required
Erection of 11 KV Disc & Pin insulator with G.I. bolts and nuts and spindle etc. as required.
Supplying and fixing of 32 mm dia x 0.75 mtr long GI pipe (medium class) bracket for mounting of LED light fitting on pole / wall including bending the pipe to required shape, 2 nos 40mm x 3mm flat iron clamps with nuts, bolts and washer, painting etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Dismantling of 9/10/11 mtr damaged poles with bracket etc.
Dismantling of damaged part of overhead lines comprising of copper/aluminium overhead conductor, GI wire, cross arms, insulators etc as required
Note: The estimated cost put to tender is excluding the PF and Pension Component. These statutory payment as applicable shall be reimbursed to the contractor on production of proof of payment limited to the maximum likely number of workmen to be deployed per day is 06 nos.
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_366272.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.79 MB
Tendernotice_2.pdf
PDF • 1.38 MB
Tendernotice_3.pdf
PDF • 0.16 MB
BOQ_366272.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid