Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | ₹16.7 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹18.5 L+₹1.8 L (10.9%)Rejected-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | ₹18.5 L+₹1.8 L (10.9%) | L2 | Rejected-AOC Not Lowest |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
20 May 2020, 6:00 pmClosed
GE (I) (AF) SHILLONG
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
CA NO. GE (I) (AF)/SHL/ OF 2020-2021 PROVISION OF STORE FOR CERTAIN BUILDING AND SPECIAL REPAIRS TO BUILDING No. P-1 (POWER HOUSE) AT LAITKOR PEAK, UNDER GE(I) (AF) SHILLONG
2020_MES_331675_2
8033/19/SHL/2019/20
Open Tender
Civil Works
Item Rate
180 days
SHILLONG LAITKOR PEAK
For Enlisted Contractors Class E Category a i and for unenlisted contractors meeting enlistment criteria for required Class and Category
7 documents required · 7 mandatory
₹500
GE (I) (AF) SHILLONG
₹47,000
Yes
1 Jun 2020
21 Apr 2020
21 May 2020
21 Apr 2020
20 May 2020
29 Apr 2020
21 Apr 2020 - 25 Apr 2020
Amount
Note : All unserviceable materials obtained out of demolition/dismantling/taking down (other than those for which credit catered under Schedule of credit) shall be disposed of outside MoD Land. Quoted rates against respective item shall deemed to include for same.
B/R ITEMS Demolition of brick work/ block masonry or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material complete all as specified directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in roofs, floors (other than ground floors), beams, staircase, landings, chajjas and similar suspended work complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removal all rubbish material complete all as directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness above ground floor and removal all rubbish material complete all as directed.
Demolition of unreinforced cement concrete in any position not otherwise specifically provided for and removal all rubbish material complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutters from the frames) & removing from site area n.exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutters from the frames) & removing from site area exc 1.5 Sqm & n. exc 4.00 sqm each complete all as specified and directed.
Dismantling structural steel work as in grills, guard bars, bands, straps, brackets etc complete all as specified and directed.
Taking down existing roof treatment including PCC padding over roof, removing complete layer of bitumen under PCC padding, cement mortar & felt cleaning the surface by hacking to receive plaster and removing demolished material outside MD land complete all as specified and directed.
Dismantling plain or corrugated steel sheeting/galvalume sheet any guage, thickness including Nainital or similar pattern roof covering,complete all as specified and directed
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down cement or cement lime plaster any description, on brick or stone walls, etc. including raking out joints, hacking for key & scrubbing down with water, etc. & removing rubbish off the premises, complete all as directed.
Hacking out old broken glass (any thickness size quality or description) from wooden frames or stone concrete or brick surrounds, glazed with putty or fixed with beeds complete all as specified and directed.
Taking up or down steel tubing and connections alongwith bib tap, stop cocks and other fittings including cleaning for refixing or removal complete all as specified and directed :-
15mm bore.
20mm bore.
Dismantling cast iron drain pipe alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or from trenches as required complete all as specified and directed of following sizes :-
75mm bore.
100mm bore. (Note :- The length shall be measured along the centre line including fittings and accessoires).
M & L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M & L for Reinforced cement concrete 1:1 ½ : 3 type A-1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs, and in shelves and the like complete all as specified and directed.
M&L for pre-cast cement concrete block masonry 1:3:6 Type C-1 using 20mm graded stone aggregate with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4, complete all as specified and directed.
Supply only integral water proofing compound ISI marked as approved complete all as specified and directed.
Supply only integral water proofing liquid complete all as directed.
S & F 20mm thick second class hardwood boarding planed one side with butt joints as in eaves board fixed with nails in any situation (except flooring and skirting) complete all as specified and directed.
M & L for use & waste of Form work to soffits of suspended slabs such as roof slabs, floor slabs, landing horizontal or slopping similar work not. exc 200mm thick for flat fair finished surfaces complete all as specified and directed.
M & L for second class hard wood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S & F 35mm thick glazed and skeleton door shutters open rebated of second class hard wood rail and styles, prepared to receive glass/gauge etc without sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I). Wood used shall be kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed. (Note :- S & F Glass/gauge shall be measured and paid for separately)
S & F 25mm thick glazed and skeleton door shutters open rebated of second class hard wood rail and styles, prepared to receive glass/gauge etc (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8, clause 8.24 (b) and as per IS-1003(Part-I). Wood used shall be kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed. (Note :- S & F Glass/gauge shall be measured and paid for separately)
S & F 30mm thick flush door shutter, solid core construction with block board core and plywood face panels, commercial type on both side complete and size of member of shutters as specified in SSR Part-I (2009) section 8 all complete all as directed.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with mild steel square tube, In opening complete all as per specifications and drawings as applicable to item 08095 given in SSR Part – II (2010).
S & F Factory made solid PVC moulded door shutter, 28 to 30 mm thick (style), with 2, 4 or 6 raised panel design with 2mm thick moulded prelaminated PVC sheet on the front face & 2mm thick plain colour PVC sheet on back face, supplying and fixing in frame at site as all as per specifications and drawings as applicable to item 08101 given in SSR Part – II.
S & F butt hinges, 100mm long, heavy weight, colled rolled mild steel & ISI marked complete all as specified and directed.
S & F butt hinges, medium weight, colled rolled mild steel & ISI marked complete all as specified and directed for following sizes:-
75 mm long.
100mm long.
S & F 125mm long aluminium anodized barrel tower bolt of extruded section ISI marked complete all as specified and directed.
S & F 150mm long aluminium anodized barrel tower bolt of extruded section ISI marked complete all as specified and directed.
S & F 200mm long aluminium anodized barrel tower bolt of extruded section ISI marked complete all as specified and directed.
S & F 100mm size extruded aluminium alloy handles, fabricated type, anodised, ISI marked complete all as specified and directed.
S & F 125mm size extruded aluminium alloy handles, fabricated type, anodised, ISI marked complete all as specified and directed.
S & F 150mm size extruded aluminium alloy handles, fabricated type, anodised, ISI marked complete all as specified and directed.
S & F 300 mm long aluminium alloy, anodised sliding door bolts, plate type with bolt not less than 16mm dia with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy and fixed complete all as directed
S & F aluminium (Die cast) body, door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed complete all as directed.
S & F in repairs chromium plated brass tubular towel rail 20 mm dia, D type 60 cm long between flanges complete all as directed.
Dismantling existing steel windows and S & F steel windows with side hung shutters including box type hinges with steel handles & steel pag stay complete (with glazing bars), dovetailed or welded including fixing of lugs in PCC 1:2:4, type B-1, using 20mm graded stone aggregate & making good walls & cills to match the existing and including one coat of red oxide/ zinc chrome primer complete all as specified and directed.
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M & L for TMT bars 6 to 8 mm dia, cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S & F mild steel framed work conforming to Fe-290 Gde E-165 as in as in window guard bars, grills or forged into spikes, framed balusters, walkway railing and similar work including welding complete all as specified and directed.
M & L for mild steel work conforming to Fe-290 Gde E-165 as in hold fast of flat iron bands, straps, supports or stays for rain water, ventilating pipes cut to length, bend to shap including bolts if required and wall tie, clamps etc., and including preparing surfaces and treated with tar and sanded with clean sharp sand complete all as specified and directed.
S&F mild steel work in tubular trusses, purlins including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161 grade St-240 including notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts including rivets or nuts and bolts, providing and fixing cleats, fish plates, gusset plates etc and also for wedging, plumbing, turning up & fixing complete all as specified and directed.
S & F for mild steel screw bolts (purpose made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 30cm long and dia of neck not exceeding 12mm complete all as specified and directed
Dismantling existing aluminium frame work and Supply fabrication and fixing powder coated (Thickness of powder coating not less than 50 micron) anodized aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleats for fixing etc complete all as specified and directed.
Dismantling existing aluminium door shutters and Supply fabrication and fixing powder coated (Thickness of powder coating not less than 50 micron) aluminium door shutters, side hung type without sash bars, aluminium section weighing 0.55 Kg/RM including necessary jointing cleats, glazing clips, rubber neoprene packing, powder coated anodised aluminium snap beading, screws, powder coated aluminium fittings, such as handle (01 No for each leaf) etc complete all as specified and directed. (Note :- Glazing/wire mesh shall be measured and paid separately under respective items of Schedule.
Dismantling existing aluminium windows/ventilator shutters and Supply fabrication and fixing powder coated (Thickness of powder coating not less than 50 micron) aluminium windows and ventilator shutters, side hung type without sash bars, aluminium section weighing 0.55 Kg/RM including necessary jointing cleats, glazing clips, rubber neoprene packing, powder coated anodised aluminium snap beading, screws, powder coated anodised aluminium fittings such as peg stays 150mm long (01 No. for each leaf), Butt hinges type B-21 100mm size (02 Nos for each leaf) & handle (01 No for each leaf) etc complete all as specified and directed. (Note :- Glazing/wire mesh shall be measured and paid separately under respective items of Schedule.
Supply and fixing star lock powder coated for sliding aluminium windows and ventilator shuttersand fixed all as per manufacturer instructions complete all as specified and directed.
M & L for applying cement slurry over existing roof surface @ 3 Kg/Sqm complete all as specified and directed.
M & L for PCC (1:2:4) type B-0 using 10/12.5 mm graded stone aggregates laid over roof slab after applying cement slurry for filling undulations finished even and smooth without using extra cement complete all specified and directed.
M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:4, over RCC roof slabs for laying water proofing treatment mixed with using water proofing liquid @ 150 ml per bag of cement complete all as directed. (Note : Water proofing liquid shall be measured and paid separately)
Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.5 Kg/Sqm , black finish reinforced with non-woven polyester reinforcement matt, with a thermo fusable finish laid over compatible cold emulsion bituminous primer applied at the rate of 0.40 Kg/Sqm by torching with a propane or a butane gas torch, with a overlap of 75mm on longitudinal direction and 100mm on transverse direction including sealing all as per manufacturer’s instructions complete all as directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 100 Gms/Sqm. (vi) Above aspects are deemed to be included in quoted rate.
S & F for pre-painted galvalume aluminum zinc coating GI based trapizoidal profile steel sheet 0.50mm thick (overall) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturers instructions complete all as specified and directed.
S & F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick (overall) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturers instructions completed all as specified and directed.
M & L for 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with L type or J type or cranked hook bolt and washer, in roof , walls etc of class VIII (Zinc coating 120 gm/sqm) complete all as specified and directed.
S & F in repairs 12 mm thick Prelaminated particle, board, exterior grade, prelaminated one side with decorative choice laminations & other side balancing white lamination and alround covered with 6mm thick teak wood beading/lipping fixed with screwed to timber frame complete all as directed.
S & F anodised aluminium snap grid frame work for false ceiling complete all as per manufacturer's instruction & directed. Note :- (a) Size of main tee - 38x25x1.5mm. (b) Size of wall angle 25x25x1mm. (c) Size of grid 605x605mm.
S & F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
S & F 10mm PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium / G.I. / M.S. as per specification and drawing complete all as specified and directed.
M & L for 20 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
M & L for 50mm thick PCC 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in paths, pavings and hardstanding top exposed surface finished even and smooth without using extra cement complete all as specified and directed.
M & L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed.
M & L for chequered cement concrete tiles 20cm x 20cm x 25mm thick with grey cement and no pigment, set, jointed and pointed in neat cement slurry in floor complete all as specified and directed.
M & L for 50mm thick PCC 1:3:6 , type C-1 using 20 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 2 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed.
M & L for rendering 10mm thick in cement mortar 1:3 on fair faces of brick or concrete surfaces finished even and rough for receiving wall tiles/dado complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick masonry/ concrete surface, finished even and smooth without using extra cement complete all as specified and directed.
M & L for glazed ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as on vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as specified and directed.
M & L for glazed ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as on vertical surfaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles complete all as specified and directed.
S & F 4mm thick sheet glass ordinary quality and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all specified and as directed.
S & F 5.5mm thick sheet glass ordinary quality and glazing with oil putty in squares exc 0.5 sq. m in each pane complete all specified and as directed.
M & L for preparing newly plastered surfaces and applying three coats of white wash on walls complete all as specified and directed.
M&L for preparing newly plastered walls surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M & L for preparation of new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint of 1st grade quality over and including one coat of pink primer complete all as specified and directed.
M & L for preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of 1st grade quality over and including one coat of red oxide zinc chrome primer complete all as specified and directed.
M & L for preparing surface of wood or wood based materials, new or old of any description and girth, not otherwise described and treated with creosote complete all as specified and directed.
S&F steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed for following sizes:-
15mm bore.
20mm bore.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not exc 10 cm girth complete all as directed.
S & F 15mm bore bib tap cast copper alloy fancy type chromium plated long body with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F 15mm bore stop valve cast copper alloy chromium plated, fancy type screwed down high pressure long shank and cup concealed type with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.
S & F in repairs PVC connection pipe 15mm dia with PTMT nuts of length 600mm complete all as specified and directed.
S & F cast iron(sand cast), soil, waste and vent pipe in any length with or without ears with cement joints fixed on walls, laid in floors/trenches complete all as specified and directed for following sizes:-
75mm bore.
100mm bore.
Supply & fixing cast iron bends (any radius), diminishing pieces or tapers ( larger bore measured) fixed with cement joints all as specified and directed for following sizes:-
75mm bore.
100mm bore.
S & F in repairs cast iron floor trap 100mm dia outlet plain with stainless steel grating including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 complete all as directed.
S&F stack clamps for 75mm bore pipe out of 50mm X 5mm flat iron and 16mm dia round iron stays, including bolts & nuts and securing ends of stays to wall or roof complete all as specified and directed by Engineer-in-Charge.
S & F in repairs vitreous china wash basin, white, flat back, size 550 x 400 mm including one no 15mm bore fancy type pillar taps, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered HOT or COLD with long screwed shanks and fly nuts, screwed for iron pipe, one No PVC waste pipe 25 mm dia and 75 cm long with 32 mm dia connector, 32mm size waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange end, bedded in red lead cement and other fixed complete including cutting for and pinning in ends of bracket or erecting stand complete all as directed.
S & F in repairs 32mm dia waste coupling of PTMT (half or full threaded) minimum weight 32mm-45 gms complete all as specified and directed.
S & F in repairs Vitreous china bowl urinal flat back, size of 465 X 355 X 265 mm white with grating and union for discharge pipe including, waste pipe and PVC connection, bedding urinal against wall in cement mortar 1:2 securing urinal to, plugs with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and directed.
S & F in repairs vitreous China squatting pan (Orissa pattern) water closet (white) of size 580 mm x 440 mm with integral foot rests, 'P' or 'S' trap, including connection to trap, flushing pipe and antisyphonage pipe etc and including provision of PCC (1:5:10) type E-2 lean concrete in filling, making good to floor (excluding flushing cistern and flush pipe etc) complete all as specified and directed.
S&F in repairs, PVC low level cistern 10 litres capacity, valve less, symphonic action type with float, handle including 32mm dia PVC flush pipe of polyethylene of low or high density & bracket etc complete all as specified and directed.
S & F in repair grating doom 100 mm dia of PTMT (minimum weight 25 gms), complete all as specified and directed.
E/M ITEMS Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete from existing conduits, from PVC Casing/capping with all fittings, such as switches, ceiling rose, pendants, sockets, lamp holder, fan regulators, sketch/brackets light fittings (except tube light fitting) etc and removal of old material from site (except switches, sockets and fittings to be reused) and making good disturbed surfaces of walls, floors ceiling etc complete all as specified and directed to match with existing surfaces.
Taking down old unserviceable light fittings any type and removal from site and making good disturbed surfaces of walls, ceiling etc complete all as specified and directed to match with existing surfaces.
Taking down main switch/DB’s including MCB’s with board and fixture of any description and making good disturbed surface of walls etc complete all as directed.
Taking down the existing unserviceable submain/service connection wiring any size and any description including conduits all as directed.
Taking out old unserviceable LT UG cable of size 4 core 25 Sqmm laid in trenches, ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe including removal of brick cable protection cover, GI tubing etc complete all as specified and directed. (Note :- Excavation & earth work, shall be measured and paid for seprately under respective items of the BOQ )
M & L for taking down existing exhaust fan heavy duty from ceiling of roof approx height 15 mtr and depositing in MES store yard including necessary T&P for lowering the exhaust fan on ground complete all as specified and directed.
Cutting circular opening through wall (old masonry built in cement mortar) for exhaust fan openings (with or without reveals) or enlarging existing openings or cutting out defective masonry for under pinning including providing, fixing and removing, shoring, cleaning and removing rubbish off the premises etc and M & L for forming jambs, etc, to openings including cutting, toothings and properly bonding into old work, including facing and rendering 10mm thick plastering in cement mortar 1:3 to match existing work and finishing the opening with white/colour wash/OBD to match existing finish, complete all as specified and directed
M & L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS-H cable PVC rigid non metallic conduit (minimum 20mm bore size) and conduit accessories concealed in walls/ceiling/floors all as per IS including sunk type pressed steel terminal boxes (Heavy duty) with 3mm thick plastic laminated bakelite sheet top cover for mounting switches, sockets, regulators, bell push etc, including 1.5 Sq.mm solid copper conductor with green PVC FRLS-H insulated unsheathed earth continuity conductor to common earth & connecting to earth dolly for the following :- (Note : The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces. )
One light point/fan point/bell point controlled by one, one way switch.
One 5 Amps socket outlet/switch socket outlet on independent board.
One 5 Amps socket outlet/switch socket outlet on same board with other switches.
M & L for point wiring complete for 15 Amps socket outlet on independent board with 2.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS-H cable drawn through and including PVC rigid non metallic conduit (minimum 20mm bore size) and conduit accessories concealed in walls/ceiling/floors all as per IS including sunk type pressed steel terminal boxes (Heavy duty) with 3mm thick plastic laminated bakelite sheet top cover for mounting switches, sockets, including 2.5 Sq.mm multistranded copper conductor with green PVC FRLS-H insulated unsheathed earth continuity conductor to common earth & connecting to earth dolly. Notes : The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces.
S & F switch piano flush type 5/6 Amps, single pole, one way, 230 Volts complete all as specified and directed.
Supply and Fix Socket outlet 2/3 pin 5 Amps, flush type, complete all as specified and directed.
S & F switch socket combination two-in-one (multipurpose), 5 pin , 5/6 Amp, flush type, 240 Volts complete all as specified & directed.
S & F switch socket combination two-in-one (multipurpose), 6 pin, 5 Amp and 15 Amp, flush type, universal 240 Volts complete all as specified & directed.
S & F lamp holder, PVC / polycarbonate type with back plate suitable for Angle fittings complete all as specified and directed.
S & F ceiling rose, three terminal, PVC / poly carbonate isolated body, complete all as specified and directed.
Supply and fix LED tube light batten fitting, 18 Watt 230 V, 50 Hz with with all standard fittings etc pre-wired including LED tube and connecting the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed. {Model/Make : Cat Part No BLRB-DB 118 for tube light fitting and Cat Part No. BLRB 18W CW for LED tube light of make Bajaj or equivalent model of makes listed in List of makes}.
Supply and fix recess mounted LED luminaire 600mm x 600mm size, 36 watt, 230 V, 50 Hz, colour temperature white with all standard fittings pre-wired and connecting the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed. {Model/Make : Model 'SKYLUX' Cat Part No BZRSQL 36W GZi CW of make Bajaj or equivalent model of makes listed in List makes}.
Supply and fix LED mirror light with a high output, PMMA diffuser for glare free light of dimension 600 mm and connecting the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed. {Model/Make : Cat Part No. LCL-14-CDL of make Crompton or equivalent model of makes listed in List makes}.
S & F sheet metal enclosure double door DB SPN 2 way, 240 volts protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 all as specified and directed.
S & F sheet metal enclosure double door DB SPN 4 way, 240 volts protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity all as specified and directed.
S & F sheet metal enclosure double door DB SPN 8 way, 240 volts protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity all as specified and directed.
S & F sheet metal enclosure double door DB SPN 12 way, 240 volts protection class IP-43 made out of CRCA mild steel sheet surface with epoxy powder coated surface confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity all as specified and directed.
S & F sheet metal enclosure double door DB TPN 4 way, 440/415volts protection class IP-43 made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted confirming to IS-13032, IS 8623, BS-5484 with tinned copper bus bar of 200 Amps capacity all as specified and directed.
S & F MCB SP 6 to 32 Amps, 240 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed.
S & F MCB SPN 40 Amps, 240 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed.
S & F MCB DP 40 Amps, 240 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed.
S & F MCB TPN 63 Amps, 415 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed.
S & F for submain wiring with 2 single core PVC insulated & PVC unsheathed FRLS-H cable 1100 Volt grade with 06 Sqmm copper multistranded conductor drawn through and including PVC conduit 25mm bore concealed in walls/ceiling/floors including 6 Sqmm single core multistranded copper conductor 1100 volts grade PVC insulated and unsheathed FRLS-H cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: - Two runs of main cable, one run of earth continuity conductor and one run of conduit will be measured and paid as one length only. (ii) The rate quoted shall deemed to include for cutting chases for concealing PVC conduit and making good disturbed surfaces.
M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 15mm bore for protection of earth wire and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 5 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing and including dismantling and taking out old earthing complete all as specified and directed. Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work is included in the quoted rate.
S & F exhaust fan of 450mm sweep,metal body, heavy duty, double ball bearing, 1400 RPM, 4 blades, suitable for SP 230/250 Volts, 50 Hz AC supply complete with louver shutter including fixing/ grouting of frame & louvers in wall & connecting with and including 3 Nos 1.5 Sqmm single core, PVC insulated but unsheathed FRLS 1100 Volts grade cable with multistranded copper conductor from ceiling rose to fan complete all as directed. Model & Make : Model Ventil Air DB of make Havells or equivalent model of Make Bajaj/ Crompton/Usha/Orient
Supply/Laying / fixing, jointing, testing and commissioning, LT under ground cable 1100 volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts/ pipes/fixed on walls/poles complete all as specified and directed of following sizes:-.
2 core 10 Sqmm
4 core 25 Sqmm NOTE :- (a) Excavation & earth work, shall be measured and paid for seprately under respective items of the BOQ. (b) GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the BOQ (c) Road cutting involved during excavation for laying of cables etc shall be made good as per existing road. Nothing extra shall be admissible on this account. Quoted rates of the item shall be inclusive of the above provisions.
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 meter in depth for foundation, laying of cable, pole etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sqm on plan and getting out in soft/loose soil complete all as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick,complete, all as specified and directed.
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point,complete, all as specified and directed .
M & L for dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
M & L for brick protection for UG XLPE cable with sub class 'B' bricks, old size laid dry and flat abutting each other with gaps between adjacent brick 10mm with width equal to length of brick in trenches across the cable complete all as directed.
Taking out existing street light fitting of any type/pattern and Supply, Installation, commissioning and testing of High Intensity type LED based street light of 45 watts (or 45 + 3 watts as per manufaturer) rating enclosed in high grade aluminum pressure die-cast housing with heat resistant toughened flat glass/ High efficiency polycarbonate UV stabilized cover with integrated lens suitably gasketed all including high power LEDs with secondary lens optics, surge protection device (SPD) : internal SPD-3 to 5 KV and external SPD-10KV for both LED and driver, inbuilt micro controller power supply, Ingress protection IP-65/66, operating voltage range 140 V - 270 V, 50 HZ, AC heat management compliance & system efficacy of fitting should not less than 100 lumen/Watt. Lumens Flux 4500 Lumen, easily adjustable for different mounting pipes, top opening seprate electronic driver compartment cabin, safety compliance of driver to IS 15885 Part 2/Section 13 and luminaire safety compliance to IS-10322/IEC 60958, dust and water proof cabinet, Effeciency of driver electronic not less than 90%, power factor of complete fitting not less than 0.95, Lamp life should not be less than 50000 operating hours with L70 criterion. Total Harmonic Distortion (THD) less than 10%, Minimum view angle of the LED not less than 120 degree, colour Rendering Index (CRI) not less than 70, CCT 5700K-6500K, Operating temperature -10º C to + 50º C, Working Humidity 10% to 90% RH and connecting upto street light feeder/junction box with & including three runs of 2.5 Sqmm PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volts grade & testing complete all as specified & directed. {Model/Make:- Cat Part No. ENDURAPEARLNEOSL45WLED75PASYTOPC of make Havells or equivalent model of makes listed in List of makes in Particular specification). Note :- (i) The contractor should give warranty for the complete fitting including its LEDs, Lens, Driver, SPD, Protection devices and all Electric/Electronics connected parts for minimum 3 (Three) years and Contractor should submit manufacturers warranty certificate for fittings for minimum 3 (Three) years in writting.
(ii) The contractor should submit latest LM-79 & LM-80 reports (Test certificate) for street light fittings from NABL accredited Lab. The quoted rates shall deemed to be inclusive for above stipulations. (iii) All LED light/luminaries must meet the provision laid down in relevant ISs. (iv) LED light fittings is required to be fixed on steel tubular poles/PCC poles or swan neck swaged tubular poles with all T&P and accessories etc complete including making connection , testing etc complete. No extra payment shall be admissible on these account. (v) Contractor shall furnish a written replacement warranty to the department in favour of GE for a period of 3 (Three) years from the date of completion of the work. The complete documents regarding warranty shall be handed over to the GE at the time of execution of the items. For this purpose, contractor may obtain Warranty/ Extended warranty from the manufacturer for the above period. (vi) The warranty furnished by the contractor shall meet the reqirement in following conditions :- (a) Manufacturing defects. (b) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen of the LED/Luminaries. (vi) The consolidated rate for Srl Nos. 131.00 & 131.10 shall be quoted against Srl No. 137.00 of BOQ.
Supply and fix in replacement LED flood light 100 Watts, protection class IP-66 with all standard fittings pre-wired and connecting the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed. {Model/Make:- Cat Part No. LFLN-100-CDL/60 of make Crompton or equivalent model of makes listed inList of Makes to Particular specification).
mahinder electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .