| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 CrAccepted-AOC 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹5.8 Cr Quoted ₹5.9 Cr | L1 | Accepted-AOC Due to L1 rate quoted |
| 2 | L2₹6.4 Cr+₹49.7 L (8.46%)Rejected-Finance WZ 487 2 MS BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹6.4 Cr+₹49.7 L (8.46%) | L2 | Rejected-Finance other than L1 rate quoted |
| 3 | L3₹7.3 Cr+₹1.5 Cr (24.9%)Rejected-Finance | ₹7.3 Cr+₹1.5 Cr (24.9%) | L3 | Rejected-Finance other than L1 rate quoted |
| 4 | L4₹8.9 Cr+₹3.0 Cr (51.3%)Rejected-Finance ANANDI NIWAS MAIN ROAD ROURKELA 769001 | ROURKELA | SUNDERGARH | ODISHA | 769001 | ₹8.9 Cr+₹3.0 Cr (51.3%) | L4 | Rejected-Finance other than L1 rate quoted |
| 5 | L5₹9.2 Cr+₹3.3 Cr (56.4%)Rejected-Finance C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹9.2 Cr+₹3.3 Cr (56.4%) | L5 | Rejected-Finance other than L1 rate quoted |
Tender Value
₹3.8 Cr
EMD Value
₹4.5 L
Closing Date
19 Oct 2024, 6:00 pmClosed
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
COMPLETION OF INCOMPLETE AND BALANCE WORK FOR PROVN OF AUDITORIUM AT KAPURTHALA
2024_MES_669002_1
81079/E8
Open Tender
Civil Works
Lump-sum
220 days
Jalandhar Cantt
All documents as per NIT
8 documents required · 8 mandatory
₹2,000
Garrison Engineer Kapurthala
₹4.5 L
Yes
21 Nov 2024
31 Aug 2024
28 Oct 2024
31 Aug 2024
19 Oct 2024
28 Sept 2024
Amount
Note: (i) Please refer Schedule 'A' Notes given on serial page No. 20 to 28 of tender documents. (ii) Item from Srl No. 3 to 12 of this document shall be Part-XV (Miscellaneous items) of BOQ (iii) Unless otherwise specified, earth work and excavation shall be measured and paid separately for item No 3 to 12 of BOQ
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for PARTLY COMPLETED BUILDING WORKS as listed in Schedule 'A' Part-I brought forward from serial page No. 29
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-II brought forward from serial page No. 33.
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 34.
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-IV brought forward from serial page No. 36.
Lump sum price worked out by the contractor for ROAD, PATH & CULVERT WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 38.
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule 'A' Part-VI brought forward from serial page No. 39.
Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKS listed in Schedule 'A' Part-VII brought forward from serial page No. 40
Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTH WORKS as listed in Schedule 'A' Part-VIII brought forward from serial page No. 41.
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-IX brought forward from serial page No. 44.
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-X brought forward from serial page No. 45.
Lump sum price worked out by the contractor for LIGHTENING PROTECTION WORKS listed in Schedule 'A' Part-XI brought forward from serial page No. 46.
Lump sum price worked out by the contractor for FIRE FIGHTING WORKS as listed in Schedule 'A' Part-XII brought forward from serial page No. 49.
Lump sum price worked out by the contractor for VENTILATION AND SUMMER APPLIANCES WORKS as listed in Schedule 'A' Part-XIII brought forward from serial page No. 50
Lump sum price worked out by the contractor for ARBORICULTRE WORKS as listed in Schedule 'A' Part-XIV brought forward from serial page No. 51.
INTERNAL ELECTRIC SUPPLY WORKS
Supply and fixing modular metal flush box of 8 module complete all as specified and directed.
Supply and fixing RCCB FP AC 25 Amp 415V 50 Hz 10 KA as per IS : 12640-1 & IEC/EN 61008-1 complete all as specified
Supply and fixing RCCB FP AC 63 Amp 415V 50 Hz 10 KA as per IS : 12640-1 & IEC/EN 61008-1 complete all as specified
Supply and fixing MCB, SPN 240 volts, capacity 6 to 32 Amps, 50 Hz, 10 KA complete all as specified.
Supply and fixing MCB, SP 240 volts, capacity 6 to 32 Amps, 50 Hz, 10 KA complete all as specified.
Supply and fixing modular dummy plate complete all as specified.
Supply and fixing lamp holder metal ring of modular fittings inlcuding LED lamp 6 W 220-240 volts 50 Hz complete all as specified.
Supply and fixing ceiling fan 5 star rating 1200mm sweep including provision of cord flexible copper conductor 23/0.0076 three core from ceiling rose to connector complete all as specified.
Supply and fixing High speed wall fan 450 mm sweep, 220-240, 50 Hz including provision of PVC fiexible copper cable of size 23/.0076/ three core from ceiling rose to fan for giving connection complete all as speciifed.
Supply and fixing exhaust fan heavy duty with louvers complete of 300mm sweep corrosion less, double ball bearings with louvers with bolts,nuts and washers ,size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan for giving connection complete allas specified.
Supply and fixing exhaust fan heavy duty with louvers complete of 380mm sweep corrosion less, double ball bearings with louvers with bolts,nuts and washers ,size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan for giving connection complete allas specified. Note for Srl item No. 3.10 & 3.11 : Cost of opening in wall and grouting of mild steel work shall be deemed included in the lump sum cost of the building.
Supply and fixing energy efficient LED, enviornment friendly tube light fittings surface/ pendent mounted compete with white powder coated slim box type batten of formed CRCA with snap on installer suitable for 1200 mm long 20W LED tube rod batten or LED tube light base complete with 1200m long LED rod 1x20 watt, 6500K for white illumination including all accessories and connection from ceiling rose to connector complete all as specified.
Supply and fixing ceiling mounted opal polycarbonate diffused 1 x 1 feet aesthetically desinged LED luminaire flat panel soft light and glare free symmetrical illumination of rating 15W 240V 50 Hz including surge protection device and making electrical connection complete in all respect and as specified .
Supply and fixing energy efficient LED enviornment friendly LED security light B-1 class made up of pressure die cast aluminium housing with high power LED as lighting source and lense embedded for area/ path illumination as per National Lighting Code (SP 72:2010) by using security light of 25 watts (total input power), CCT - 5000- 5500K CRI > 67, PF > 0.95, rated output lumens 2100 Im, operating performance temp - 10 degree centigrade + 45 degree centigrade LED module life span 50000 burning hrs, with toughened glass, external surge and over voltage protection device up to 440V alongwith connection 3 core copper flexible cable of size 0.75 sqmm to be provided with weather proof connector, LED module & driver IP-66 rated duly ISI marked IS:16103 part (1&2) 2012 : efficency 85% constant current Vtd < 10%, lthd < 15% complete with 40mm dia GI pipe light grade 1.5 mtr long bracket and FI 40 x 6 mm clamp 2 Nos with nut bolts etc including painting of clamps with two coats of aluminium paint over a coat of primer (for bldg security lights) complete all as specified.
Supply and fixing energy efficient, environmently friendly, long life die cast aluminium IP 65 powerful LED luminaire with high power LED as light source with lumen efficacy>100Im/W, CCT>5700K, operating temperature-10 to +50 degree centrigrade, 220-240 volts, 50 Hz, 240 watt and surge protection 5 KV, pf>0.95 complete all as specified and directed
Supply and fixing halogen light/ stage filler light 1000W/ Eqvt LED light fitting 220-240 volts, 50Hz complete all as specified and directed
Supply and fixing fresnel spot light fitting of suitable watts 220-240 volts, 50 Hz complete all as specified and directed
Supply and fixing profile spot light for sharp focusing 220-240 volts, 50 Hz complete all as specified and directed Note for Srl No. 3.15 to 3.18 : The rates also includes one suitable rating modular type dimmer switch to control the light all as shown in drawings
Supply and fixing energy efficient LED, enviornment friendly, linear and compact LED mirror light luminaire with decorvative end caps, polycarbonate body & ribbed opal diffuser LED rod 1x8W, CCT 6000K, 220-240V, 50 Hz for white illumination including surge protection device and all accessories and connection from ceiling rose to connector all as specified and directed.
Supply and fixing porch light energy efficient LED, enviornment friendly, aestheitically designed, moulded body, ceiling light LED fixture IP 54 with diffuser to give glare free light with Lamp LED 1 x 8/9 W 6000K, 220-240V, 50 Hzcomplete all as specified and directed
Supply and fix recess mounted diffused optics LED downlight elegantly designed pressue die cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separated replaceable electronic driver compatible for Analog dimming of rating 20/21 W 50 Hz, 220-240 Volts complete including surge protection device and making electrical connection all as specified and directed. Note : The rates also includes clamps,nuts,bolts etc for mounting of downlights on ceiling /false ceiling and includess one suitable rating modular type dimmer switch to control 04 Nos of downlights from projector room complete all as specified.
Supply and fix step light luminaire powder coated die cast aluminium housing IP 65 protection 4 W, 220-240 votls 50 Hz and making electrical connection all as specified and directed.
Supply and fixing concealed sub main wiring with FRLS PVC insulated standard copper conductor with two runs of 2.5 Sqmm and 1 x 2.5 Sqmm for earth continuous earth wire including suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Two runs of PVC cable 2.5 sqmm & one run of earth wire 2.5 sqmm alongwith PVC conduit will be considered as one unit.
Supply and fixing concealed sub main wiring with FRLS PVC insulated standard copper conductor three run of 4 Sqmm and 2 run of 4 Sqmm for earth continuous earth wire including suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Three runs of PVC cable 4 sqmm & two runs of earth wire 4 sqmm alongwith PVC conduit will be considered as one unit.
Supply and fixing concealed sub main wiring with FRLS PVC insulated standard copper conductor with four runs of 4 Sqmm and 2 runs of 4 Sqmm for earth continuous earth wire including suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Four runs of PVC cable 4 sqmm & two runs of earth wire 4 sqmm alongwith PVC conduit will be considered as one unit.
Supply and draw concealed sub main wiring complete with FRLS PVC insulated standard copper conductor of size with four runs of 6 Sqmm and two runs of 6 Sqmm for earth continous earth wire including suitable PVC conduit medium grade ISI marked all as specified and directed. Note:- Four runs of 6 Sqmm and two runs of 6 Sqmm alongwith PVC, conduit of suitable dia with all accessories will be measured as on unit.
Supply and fixing concealed sub main wiring with FRLS PVC insulated standard copper conductor with four runs of 16 Sqmm and 2 runs of 16 Sqmm for earth continuous earth wire inlcuidng suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Four runs of PVC cable 16 sqmm & two runs of earth wire 16 sqmm alongwith PVC conduit will be considered as one unit.
Material & labour earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 25 x 4mm dia connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron light grade 40mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-2 using graded stone aggregate and RCC cover in M-25 (Design mix) and all as shown in Electrical Plate No. 3 of MES Schedule (Part-I) of 2009 complete all as specified and directed.
Supply and fix single sided LED signage, light 1x3W, 220-240 V, 50 Hz with red sign "EXIT" in capital letters and making electical connection complete all as specified and directed.
Supply and installing single sided LED signage, light 1x3W, 220 V, 50 Hz with red sign "ENTRY" in capital letters including in built battery back up for 2 hours and making electrical connection complete all as specified and directed.
Supply and installing single sided LED signage (Gents Toilet) with 3W LED of red/ green colour including built in battery back up for 2 hours complete all as specified and directed.
Supply and installing single sided LED signage (Ladies Toilet) with 3W LED of red/ green colour including built in battery back up for 2 hours complete all as specified and directed.
M&L for high strength, corrosion less Aluminium truss (Lighting truss) with span 12 to 16 mtr for hanging of stage light as shown in drawing as directed.
Material & labour for concealed point wiring complete with 1.5 Sqmm (nominal cross sectional area) FRLS PVC insulated multi-stranded copper conductor cable in and including medium grade PVC conduit pipe (ISI marked) including fittings & accessories with MS concealed terminal boxes suitable for modular type fitting fixture top cover for mounting switch socket etc including 1.5 Sqmm FRLS PVC copper conductor cable multi-stranded in green colour code as earth wire connected to the common earth dolly as specified for one light point/ fan point/ exhaust fan point controlled by one switch
All as per description of Sr Item No. 3.36 but for one three pin socket outlet 5 Amp on independent board.
All as per description of Srl Item No. 3.36 here-in-before but with 2.5 Sqmm cable and 2.5 Sqm copper conductor cable in green colour code as earth wire for 15 Amp socket outlet controlled by one switch complete all as specified. Note:- Socket /switch shall be measured and paid for separately
All as per description of Srl Item No. 3.36 here-in-before but with 1.5 Sqmm cable and 1.5 Sqm copper conductor as earth wire for 4 recessed mounting ceiling downlights in one row controlled by one dimmer switch complete all as specified.
All as per srl item No 3.36 here-in-before but 1.5 Sqmm cable & 1.5 Sqmm copper conductor to conductor to control 4 Nos Street lights with one switch complete all as specified and directed
All as per description of Srl Item No. 3.36 here-in-before but with 1.5 Sqmm cable and 1.5 Sqm copper conductor cable in green colour code as earth wire for 6 lights controlled by one switch complete for building security lights complete auditorium step light all as specified. Note for srl item No 3.39 to 3.41 : Ceiling downlights will be controlled from projector Room with any length of wire, conduit etc as required for wiring all as shown in drg & directed by Engr-in-Charge. The rate of same is included in rate of above item.
INTERNAL WATER SUPPLY WORKS
S&F 15 mm bore chromium plated water jet of approved quality to be fixed with EWC complete all as specified.
EXTERNAL ELECTRIC SUPPLY WORKS
Supplying, erecting and fixing pre-stressed concrete pole 11 metre long, cross section 152mm x 152mm at top and 152mm x 260mm at bottom class-9 including zebra painting of poles with two coats of synthetic enamel paint over a coat of primer, black & white strips upto 1.5mtr height from top of PCC coping in 30cm alternate block and numbering of poles complete all as specified. Note :- PCC and earth work shall be measured & paid for separately
Supply and fixing switch air break gang operated out door type HT 11 KV triple poles 400 Amps with fixed contacts of phosphorus bronze and moving contacts of copper with mechanically operating from ground level vertical mounted complete with HT insulator on steel frame operating rod made out of 25mm GI pipe medium grade worked from ground level with handle and locking arrangement with 12 insulators with test complete all as specified and directed. Note : (i) Clamps/ cross arms shall be measured and paid for separately. (ii) Original test certificate of manufacturer shall be produced, without which no payment shall be made.
Supply, installation, testing & commissioning microprocessor based automatic power factor control LT panel board (MPFCS) 433 volt, IP-65, 50 cycles per second, cubical type, front & back openable double leaf type, dust & vermin proof with locking arrangement, powder coated with approved colour, made out of CRCA sheet 3.15 mm, outdoor type with canopy, cable entry glands, double compression type, duly pre-wired with suitable pillars made out of 50mm x 50mm x 6mm angle iron, grouted in & including PCC (1:2:4) using 20mm graded stone aggregate complete as per IS: 8623-1993 & all as per latest IS specifications & suitable for housing & including following accessories : - (a) Incoming MCCB of 400 Amps TP 36 KA rupturing capacity, 3 pole thermal magnetic release type with shunt trip coil - 01 No. (b) Copper bus bar duly insulated with colour coded heat shrinkable sleeve insulation for three phase four wire system of 500 Amps capacity rating with suitable size/ type non hygroscopic, non combustible track resistant, high strength FRP/ MC/ DMC insulators. (c) Capacitor switching contactor suitable for 1 x 10 + 1 x 15 + 5 x 25 capacity shunt capacitors (Contactor Amps rating shall not be less than 1.5 times nominal rated current), three poles, coil voltage 440 volts. Each contactor shall be protected with MCB TP 10 KA, D-curve type (MCB to be provided for 1.33 times KVAR ie 100% current capacity of the MPFCS irrespective of the fact that contactor's rating is 1.5 times). (d) One set current transformer (CTs) of ratio 500/5 to be fixed on bus bars of existing panel including connection with 2 core 1.5 sqmm armoured copper conductor cable complete with gland etc. (e) Shunt capacitors MPP type heavy duty 150 KVAR distributed in steps of 7 stages with configuration (1x10 + 1x15 + 5x25) and 25 KVAR (for fixed KVAR) directly connected to maintain power factor at 0.99 or unity, housed in self-extinguishing insulating material, with built in over pressure safety devices (Capacitors shall discharge automatically with electronic reactance discharge KA of suitable rating in kiloohm & watts, when power supply is switched off) 440 volts, 50 Hz, minimum static life expectancy of more than 1,15,000 hours & switching life (minimum 5000 switching operations per year) 1,00,000 hours, output capacitance tolerance of 0% to 10%. Di-electric losses less than 0.5 watt per KVAR, temperature (Max.) 55°C, IP 30 protection all as per latest IS.
(f) Wiring of complete panel board with multi stranded 2.5 sqmm flexible PVC copper wires & copper thimbles complete with number sleeve markers. (g) Microprocessor based automatic power factor control relay unit suitable for twelve stages of capacitor bank. The processor shall have the following features: - (i) Suitable for programming at site. (ii) Over & under voltage trip point ± 15%. (iii) Self adjusting switching sequence. (iv) PF adjusting range upto 0.8 lag to 0.99 lead by digital setting keys. (v) Auto calculation of C/K value. (vi) 50 Hz frequency, 433 volts, 3 phase system. (vii) Single phase prevention of capacitors & phase reversal for capacitors including electronic over load inter connected with MCCB. (viii) 50 Hz frequency, 433 volts, 3 Phase system. (ix) Indication for operational state of capacitors LED type. (x) Current input 0.5 Amps. (xi) Low current release less than 50mA, voltage release 35 milli seconds, voltage burden 5 VA, Current burden 0.5 VA. (h) Exhaust fan of 150 mm sweep for cooling of panel.
M&L for boring hole under the road/ pavement/ hardstanding with the help of trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure not less than one metre below ground level complete all as spcified and directed.
Supply,Installation, commissioning and testing of LT outdoor panel board (factory made of approved CPRI) not less than 150 cm x 100 cm x 50 cm mounted indoor type made out of CRCA sheet 3.15 mm thick dust proof, powder coated from both side, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and copper bus bar of capacity 200 Amps rating for phase and neutral mounted on hygroscopic insulator fixed in a separate bus bar chamber separate compartment for incoming and outgoing feeder prewired with suitable size of copper conductor cable including fitted on 50x50x6mm angle iron channel with PCC foundation and provision of lugs and bushing for housing the following :- (i) Electrolite copper bus bar 800 amps for phase & neutral-04 Nos (ii) MCCB 4P 630 Amps, 50 KA, Ics = 100% of Icu having thermal & magnetic setting provision- 01 Nos (In coming) (iii) MCCB 4P 250 Amps, 36 KA, Ics = 100% of Icu having thermal & magnetic setting provision - 02 No. (iv) MCCB 4P 100 Amps, 25 KA, Ics = 100% of Icu having thermal & magnetic setting provision - 04 No. (v) MCB TPN 32 Amps, Ics = 100% of Icu 10 KA - 04 No. (SL+W/S Pump+Terrace Tank Pump + High Mast) (vi) Multi functional digital Voltmeter and ampere meter including suitable and appropriate CTs-01 Set (vii) Indicator lamp (LED R-Y-B)- 01 Set
S&F LED street light luminaries 45 watt or above 6000K epoxy powder coated pressure die-cast aluminium housing, heat resistant toughened clear glass fixed with SS screws, surge protection against lightening of 10 KV with potted type anti vibration IP-66 driver, consumption of complete fixture should not exceed 45 W +5% ingress protection : IP- 66, class-I input voltage from 120-270V, power factor above 0.95, complete all as specified and directed. Note : (i) All LED fittings shall be made in India only. (ii) All LED fittings shall have supporting LM-79 & LM-80 test certificate from Govt. approved NABL accredited lab showing the parameters duly signed by the local office bearer of manufacturer. (iii) All LED fittings shall have 5 years written warranty from local office bearer of manufacturer.
Supply & fix factory made junction box of size 250 x 300 x 125mm suitable for street light fixed on pole, made out of CRCA sheet 2mm thick having front hinged shutter with lockable arrangements, outdoor type, weather proof duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer, having the provision to connect incoming and outgoing cable of size 25sqmm 2 core including one number MCB SP, 10 KA, C-curve, 6 Amps, 240 volts and earthing plug complete all as specified and directed. Note : (a) MS Clamps, nuts, bolts required to fixing on pole shall be measured and paid seperately. (b) Cost of MCB shall be included in above rate.
Supply & fix time analog type timer switch having multiple time setting 250 V single phase of 40 Amps rating with contactor and MCB TPN as incoming and outgoing protection totally enclosed in SMC box of suitable size including mounting bracket of MS flat 3mm thick made to shape complete all as specified and directed
S&F energy saving LED flood light fitting with high pressure die-cast aluminium housing with IP-65 Class-I protection, having discrete LED structure, extruded aluminium heat sink, surge protection device of 10 KV, suitable for voltage variation 120 to 270 volts and system efficacy 90 lumens per watt, THD < 10%, power factor > 0.95 and protection for toughened glass IK05, with PMMA optics lens for uniform distribution with constant current driver and mounting cradle complete of 120 watt or above. Note : Fittings and drivers shall be made in INDIA only and supplied with LM 79 and LM 80 reports issued from NABL accredited laboratory along with NABL certificate along with 2 years written warranty for complete fitting including driver from local manufacturer's office.
Earthing complete for transformer/LT Panels with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm in and including GI pipe 40mm bore light grade as protection pipe (from top of earth plate up to the body of equipment) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe medium grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate and angle iron frame including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 5 of SSR Part-I (2009) testing on completion complete all as specified. Note : Cost of protection pipe up to 7.5metres from earth electrode will be included in the unit rate quoted by the contractor.
All as per item No. 5.10 here-in-before but using GI wire of 4mm dia as earth lead in 15mm bore protection pipe and galvanised earth plate of size 60cm x 60cm x 6mm as earth electrode (2 for 2 pole structures, 1 for GO switch, 1 lightening arrestor) complete all as specified.
Supply and fixing LED 6 watt decorative bollards with opal acrylic with IP65 protection complete all as specified and directed.
EXTERNAL WATER SUPPLY WORKS
Supplying, installing, commissioning & testing pumping set centrifugal type electric driven complete capacity 5 HP complete all as specified and directed Note : Contractor shall furnish two years guarantee from the manufacturers/ dealer. The rate quoted shall deemed to include for the same.
Supply, installation, commissioning & testing cast iron air release valve with two air outlet, conforming to IS : 14845 of size 80mm dia bore and fixing up in cast iron water supply main line of size 100mm dia complete all as specified.
Material and labour for construction of brick masonry valve pit of size 90cms x 90cmx x90cm (internal size) with mild steel sheet cover 3.15mm thick and frame of angle iron of size 50 x 50 x 6mm duly apinted with two coats of synthetic enamel paint over a coat of red oxide primer including excavation and earth work, 150mm thick PCC (1:4:8) type D-2 as in foundation, brick work in cement mortar (1:6), locking arrangement, and all inner size of pit shall be plastered 15mm thick in cement mortar (1:4) and coping in PCC (1:2:4) type B-1 over brick wall complete all as shown in Drg No CEJZ/TD-1060/08 Sh 1/3 to 3/3.
M&L for cutting in position existing 150mm bore CI water main and insertion of tee 150 x 150 x 100mm bore for tapping out branch connection inlcuding other connected fittings and excavation earthwork etc complete all as specified and directed
M&L for Non return valve/reflux valve (with bypass) of rating PN 1.6 N 100 mm dia size with nuts, bolts complete all as specified.
LIGHTENING PROTECTION WORKS
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm with & including GI pipe 40mm bore light grade as protection pipe (upto the body of equipment max 7.50 metre) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of coal dust and common salt 15cm thick, all around top and bottom and watering pipe 20mm bore of GI pipe medium grade with funnel and wire mesh complete all as shown in Electrical plate No. 3 of SSR Part-I (2009), testing on completion including PCC chamber (1:3:6) using 20mm graded stone aggregate, RCC M-25 (Design mix) cover, angle iron frame and necessary earth work complete all as specified with the following :- (a) Test point GI for size 75mm x 75mm x 25mm (b) Watering pipe GI light grade 20mm dia from top of the earth electrode upto MS funnel with bras wire mesh embedded in floor of PCC earth pit. (GI funnel should properly tightened on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits. (c) PCC earth pit 30cm x 30cm constructed in PCC (1:2:4) type B-1 exposed surfaces smoothly finished with 15mm thick cement mortar (1:6) plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40 x 40 x 4mm angle iron for 30 x 30mm PCC pit for holding the pit cover. Note :- 1. The unit rate shall include for protection pipe GI water pipe, wire mesh, funnel, excavation, RCC pit cover, test point, GI strip of size 32 x 6mm from the earth plate and upto metallic body of the quipment/ panel board etc. 2. PCC pit shall be provided at least 0.50 metres away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction elbow etc shall be deemed to be included in the unit rate. 3. RCC pit cover shall be 80mm thick RCC M-25 (Design mix) reinforced with XPM weighting not less than 4 Kg/sqm.
FIRE FIGHTENING WORKS
S&F branch pipe and nozzle for 20mm dia hose reel conforming to IS 8090 complete all as specified and directed.
S&F fire extinguisher dry chemical powder (ABC) type, 6 Kg capacity (IS : 2171/13849, 14609) complete all as specified and directed.
S&F fire extinguisher dry chemical powder (ABC) type, 4 Kg capacity (IS : 2171/13849, 14609) complete all as specified and directed.
S&F fire extinguisher ISI marked CO2 6.5 Kg capacity, squeeze grip operated, light weight (IS : 15683 or 2878) complete all as specified and directed.
S&F fire extinguisher ISI marked CO2 4.5 Kg capacity, squeeze grip operated, light weight (IS : 15683 or 2878) complete all as specified and directed.
Supply, installation, comissioning and testing of LT outdoor panel board (factory made of approved CPRI) not less than 150cm x 100cm x 50cm mounted indoor type made out of CRCA sheet 3.15 mm thick dust proof, powder coated from both side, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply inlcuding bus bar chamber and copper bus bar of capacity 200 Amps rating for phase and neutral mounted on hygroscopic insulator fixed in a separate bus bar chamber separate compartment for incoming and outgoing feeder prewired with suitable size of copper conductor cable inlcuding fitted on 50 x 50 x 6mm angle iron channel with PCC foundation and provision of lugs and bushing for housing the following :- (i) Electrolite copper bus bar 200 Amps for phase & Neutral - 04 Nos (ii) MCCB 4P 100 Amps, 25 KA ,Ics = 100% of Icu having thermal & magnetic setting provision - 01 Nos (Incoming) (iii) MCCB TP 63 Amps, 10 KA, Ics = 100% of Icu having thermal & magnetic setting provision - 03 Nos (iv) Multi functional digital voltmeter and ampere meter including suitable and appropriate CTs-01 Set (v) Indicator lamp (LED RYB) - 01 Set
Material & labour earthing complete for transformer/ LT panesl with galvanized steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, connected with and including GI strip 32mm x 6mm in and including GI pipe 40mm bore medium grade as protection pipe (from top of earth plate upto the bodty of equipment) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and comon slat 15cm thick, all around inlcuding top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300 x 300 x 300mm (top of chamber minimum 15cm above the normal ground level (1:3:6) using 20mm graded stoen aggregate and angle iron frame inlcuding necessary excavation/ earth work in any type of soil/ rock and as shown in electrical plate No. 5 of SSR part-I (2009) testing on completion complete all as specified. Note Cost of protection pipe upto 7.5 metres from earth electyrode will be included in the unit rate quoted by the contractor.
Terrace pump electric driven fire pump with min pressure of 2kg/ sqcm and 450 LPM discharge alongwith control panel and pressure switch complete all as specified.
DG SET WORKS
Installation, commissioning & testing of DG set of capacity 100 KVA all as directed by Engineer-in-Charge. Notes :- (i) Maintenance chart and manufacturer instruction shall be displayed on wooden board including catlog board within area all cost quoted. (ii) Foundation for mounting of DG set shall be done as per manufacturer design within overall cost quoted. (iii) DG Set of capacity 100 KVA has been kept at site and the same shall be handed over to the contractor through proper inventory.
Material & labour earthing complete for transformer/ LT panesl with galvanized steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, connected with and including GI strip 32mm x 6mm in and including GI pipe 40mm bore medium grade as protection pipe (from top of earth plate upto the bodty of equipment) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and comon slat 15cm thick, all around inlcuding top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300 x 300 x 300mm (top of chamber minimum 15cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-1 using 20mm graded crushed stone aggregate and angle iron frame inlcuding necessary excavation/ earth work in any type of soil/ rock and as shown in electrical plate No. 5 of SSR part-I (2009) testing on completion complete all as specified. Note Cost of protection pipe upto 7.5 metres from earth electyrode will be included in the unit rate quoted by the contractor.
VENTILATION AND SUMMER APPLIANCES WORKS
Supply and fixing voltage stabilizer electronic type copper wounded for automatic operation,single phase naturally air cooled indoor type and designed for input variation between 150 volts to 285 volts with output voltage stabilized at 230 volt with accuracy of + 2.5% and of capacity 4 KVA complete all as specified.
Supply and fixing SICT of commercial air curtain unit for prevention of dust and conditioned air losses,three phase 440 volts 50 HZ, made out of MS/CRCA sheet min thickness 18 gauge finished with two coat of red oxide primer and final coat of synthetic enamel paint (over backed) with MS-CRC 18 gauge square perforated suction grills, aluminum alloys fans and single phase electric motor, nozzles etc,complete with fittings and accessories so as to produce 1-1.5m/sec air velocity at floor level for door opening of size 64"x 90" complete all as specified and as directed.
Road, Path, & Culvert Works
M&L for providing and marking broken centre line./side line/zebra line on road pavement and the like of any description & width ,with thermoplastic paint hot applied with machine ,confirming to BS 3262 and according to the specification laid down by IRC & MOST (Ministry of surface transport) specification 2001 (4th revision) complete all as specified
S&F DUAL-DIRECTION delinator made out of 10 gauge MS rectangular pipe of Size 25x68 mm and length 1000 mm pipe stove enameled bent to 120 degree powder coated. Head made out of ABS plastic rectangular moulded with flat face provided with high intensity prismatic coloured reflector (White/yellow/red) of size 100x125 mm (total height 750 mm) with additional 2 reflective strip, 25 mm wide on both side including taking out/ dismantaling the old unserviceable delinators complete all as specified and director. GREENTILE Cat Part No. GPL-UBPH-11-56 or equivalent of DARKEYE/TATA BP SOLAR
S&F Aluminium alloy solar studs of size 140mmx128mmx82mm Height of shank 54 mm and Dia of shank 42.50 mm, 100% water proof, Plastic unbreakable scratch proof poly carbonate for maintainance free operation of 100% of compressive strength 25 Tons, colour of studs reflector Amber, Blue, Green, and White complete and as specified.
Arboriculture
Supply and planting best pot grown healthy "Sisham" of height 2.4 m and above & 2 to 2.5 year old with propotional girth including preparation complete all as specified. Breakdown details : 35 (New) + 50 (To be redone) = 85 (Total)
Supply and planting best pot grown healthy "Neem" of height 2.4 m and above & 2 to 2.5 year old with propotional girth including preparation complete all as specified. Breakdown details : 2 (New) + 30 (To be redone) = 32 (Total)
Supply and planting best quality container healthy plant "FICUS BENJIMINA" of height 2.4 m and above & 2 to 2.5 year old with propotional girth including preparation complete all as specified. Breakdown details : 70 (To be redone)
Supply and planting best quality pot grown healthy ornamental plant "CHAMPAGNE PALM" of height 2.4 m and above & 2 to 2.5 year old with propotional girth including preparation with minimum stem of species complete all as specified.
Supply and planting best quality container grown healty plant "ASHOKA PLANT" complete all as specified. Breakdown details : 20 (To be redone)
Supply and planting best quality pot grown healty ground cover plant "DURANTA GOLDEN DWARF" with minimum stem, of species complete all as specified.
Supply and planting the "KOREAN" grass by dibbling method complete all as specified.
Excavation in post hole of size not less than 60 cm x 60 cm x 60 cm deep or according to the plant size & getting out the existing earth and planting the trees straight inside the pit and filling up the pit with and including the approved red earth along with and manure (composit) in the proportion (3:1) complete all as specified and as directed by the Engineer in Charge. Note : Besides planting new trees, post holes shall be required to be re-excavated and prepared for planting the above plants. The rate quoted shall deemed to include the same. Breakdown details : 127 (New) + 170 (To be redone) = 297 (Total)
M&L for land scapinig including brought of good earth for grass, including raw stones, any shape including bring into the of landscaping complete all as specifed. Note for srl item No 12.01 to 12.09 (MAINTENANCE AND UPKEEPING OF NEWLY DEVELOPED PLANTS/ GARDENS FOR 12 MONTHS FORM THE CERTIFIED DATE OF COMPLETION OF PHASE-I) Day to Day maintenance of newly developed plants/gardens/Trees plants by deploying minimum 01 gardner (experienced mali) for guarding/ security of the plants/ gardens including triming, suitable support for trees, etc as required as per standered practice all as specified and all as directed by the Garrison Engineer (i) Preparation of the existing area /field by ploughing in soft/ordinary soil upto the depth of 30 cm and removing all the unsuitable /foreign material such as stones,weeds,tree roots etc by trenching method as given in particular specification and disposal of the rubbish/foreign material to a distance exceeding 50 m but nexc 100 m all as specified and directed. (ii) Dressing of the top soil after mixing the manure and fertilizer to a required slope and mounds. iii) Final dressing of top of surface of soil to required slope and gradient towards the manholes. (iv) Plantation of grass at the rate of 10 cmC/C both ways by dibbing root method. (v) Periodical deweeding of unwanted vegitation growth around the plants and garden area. (vi) Watering all the Plants/Gardens/Trees as required for the proper growth. (vii) Periodical Lawn Mowing. (vii) Periodical Prunning the hedges, shrubs etc. (ix) Treating the plants and soil with required manure , pesticides and fertilizer including necessary topping of red earth and finally fine dressing, levelling etc (x) During the maintenance of any plant, if it is found dead, not true to the name or size as specified or not in satisfactory growth, plant of approved size & shape shall be replaced by contractor without any extra cost to the department. (xi) Supply and application of manure, sweet earth & pesticides, fertilisers, cartage as required etc are included in quoted unit rate during maintenance period. (xii) Commencement of maintenance period of two years will start after only count after certified date of completion of Phase-II.
(xiii) Water will not be supplied by MES and contrator has to make his own arrangments. (xiv) Hose pipe required for watering will be provided by the contractor and their cost is included in the rates quoted by the contractor. (xv) Rates quoted will be deemed to be included in quoted rates.
CENTRAL AIR CONDITIONING PLANT WORKS ( SCH 'A' PART-XVI)
(c) Close transtition type automatic star delta starter suitable for compressor motor complete with ammeter with CTs own load protection, under voltage protection, protection against phase reversal & independent single phase preventor etc complete all as required - 01 Set (d) Lubrication device conristing of automatic oil pump, oil cooler, oil stainer, automatic pressure regulating valve, oil heater thermal switch etc all as specified - 01 Set (e) Shell and tube type condenser with MS Shell and integrally fined copper tubing complete with safety valves drains valves, water inlet and outlet valves, hot gas inlet and liquid outlet isolating valves, thermostat and pressure gauge at inlet and outlet - 01 set Voltas/ Blue Star/ carrier (f) Shell and tube type direct expansion chiller unit having plane copper tubes Make Voltas/ Blue Star/ Carrier - 01 Set (g) Refrigerant piping fittings, valves and accessories to interconnect compressor, condenser chiller and expansion valve - 01 Lot (h) (1) Microprocessor based panel comprising of following:- (i) Automatic capacity control including energy conservation. (ii) Microprocessor controlled pump down system. (iii) Microprocessor based sequence of starting/ stopping of equipment with fixed time delays. (iv) Alarm history fiving cause of tripping. (v) Data scanner system including operating instruction.
(vi) Power loss trip and shut down (vii) Oil pressure failure output LP/ HP cut oil. (2) Fail safe features comprising of following: (i) Under voltage protection (ii) Single phase protection (iii) Over load protection (iv) Phase imbalance protection (v) Anti Freeze protection (j) Refrigerant line accessories comprising of safety valves, angle valve, liquid line indicators - 01 lot (k) Water flow switches at inlet and outlet of chiller, water drain and air purge valves where required - 01 lot (l) Suction line and chiller insulation with miniumum 19 mm thick polyvinyl nitrite rubber insulation complete as required - 01 lot (m) Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with anti virbration pads/springs - 01 lot (n) Initial/first change of refrigerant gas and compressor oil - 01 lot (o) Chilled water flow meter of suitable size and capacity - 01 No (p) Reinforced cement concrete foundation (all as per direction of GE) for the chiller unit - 01 lot (2 working and 1 standby) (ii) Chilled water pump set Supply,erection testing and commissioning of central monoblock type chilled water pump set capable 45 GPM of water against 26 mtr head each comprising of the following and complete as per specifications. (a) Monoblock type pump set, TEFC Squirrel cage induction motor of suitable HP with class 'F' insulation 2900 rpm synchronous speed, operating on 415 +\- 10% volts, 3 phase 50 Hz AC supply - 03 Nos (02 working and 01 standby) (b) 100 mm dia dial type stem thermometer at suction and delivery - 01 lot (c) 100 mm dia dial type pressure gauges with siphon & cock at both suction and delivery - 02 Nos for each pump set (d) Mounting frame with anti vibration pads - 01 lot
(e) Reinforced cement concrete foundation for the pump unit - 01 lot (2 working and 1 standby) (f) Water flow switches at chiller pipe lines - 06 Nos. (iii) Condensor water pump set Supply,erection testing and commissioning of central monoblock condenser water pump set capable 60 GPM of water against 20 mtr head each comprising of the following and complete as per specifications. (a) Monoblock type pump set TEFC Squirrel cage induction motor of suitable HP with class 'F' insulation 2900 rpm synchronous speed, operating on 415 +\- 10% volts, 3 phase 50 Hz AC supply - 03 Nos (02 working + 01 standby) (b) 100 mm dia dial type stem thermometer at suction and delivery - 01 lot (c) 100 mm dia dial type pressure gauges with siphen & coock at both suction and delivery - 02 Nos for each pump set (d) Mounting frame with anti vibration pads - 01 lot (e) RCC cement concrete foundation (as per direction of GE) for the pump unit - 01 lot (2 working and 1 standby) (iv) Electric strip Heaters Supply, installation, testing and commissioning of electric strip heaters in supply air plenum for winter & Monsoon reheating complete with heating thermostat, humidstat and control wiring as per sepcification, having 3x2 KW for Pre-heater and 3x1 KW for Re- heater.
(v) Air Handling Units of capacity not less than 12000 CFM - 02 Nos Supply, installations, testing and commissioning of double skin floor mounted VFM type air handling units decorative type fabricated & assembled complete, made of 21 to 25 mm thick panels consisting of GI casing of thickness 0.6 mm outside layer and 0.6 mm inside layer, injected at factory by moulding machine with CFC free polyurethene foam (PUF) insulation of 40 = 2 Kg/cum complete with blower section and pre-filter section with prefilter of 10 micron of 90% effeciency, chilled water coil constructed out of copper tubes not less than 0.5 mm thick and aluminium fins, TEFC drive squirrel cage induction motor 415+/- 10% votls, centrifugal DIDW forwarded curved fan, access door, drain pan insulated with 13 mm thick nitrile rubber etc complete as per std specifications. Maximum face velocity across the coil shall be 50 rpm and each 4 row deep cooling coil AHRI certified and RH to be maintained at 55%+/-5% the other accessories are view port, limit switches of the following capacity and comprising of :- (a) UV protection including sensors (b) Thermometer & temperature guages (c) Pre filter (MERV 6) in supply air stream (d) Energy efficient (EFF-2) squirrel cage induction motors suitable for 415+/-10% volts, 50Hz, AC supply meeting criteria as per ASHRAE standard 90.1- 2007 and high effeciency (e) 3 way balancing valves with actuator of sizes as required for satisfactory completion of work-quantiy as required. '(f) Humistat of suitable capacity as required for satisfactory completion of work quantity as required. (g) Ball valves of size as required for satisfactory completion of work quantity as required. (h) Heaters for de-humidification fo suitable capacity to serve as monsoonre-heaters to meet the inside design condition and connected with control cable up to LT panels/Chiller unit. UVC emitters & fixtures in sufficient quantity so as to provided with distribution of UVC energy on the coil and in the drain pan. (j) Humidification kits spray type wit FHP monoblock type pump set of suitable capacity operating on 230 volts +/- 10% single phase 50 Hz AC supply and PVC tank 100 ltr capacity to be interlocked with chiller control panel by control cables and with AHU by suitable size GI tubing of required length - 01 Set (k) Fan belt drive package
(l) Vibration isolator (m) Fan outlet velocity not exceeding 10 mps (vi) Cooling tower Supply installation testing and commissioning of FPR cooling tower of 150 TR heat rejection capacity with FRP water basin PVC fitting with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzies or having self rotating sprinklers, statically & dynamically balanced axial flow type fan direct driven or driven through reduction gear box with TEFC induction motor, suction screen make up quick fitting arrangement over flow and drain connections with necessary valves and suitable inspection ladder, access arrangement for cooling tower interior, installed on MS girders (MS-I sections) fixed in masonary foundations with cement concrete footing, second class brick work and cement mortor 1:6 all accessories, basin fittings, fan, fan motor, suitable for 415 volts supporting structure, anti vibration mountings etc complete (including suitable size storage water tank) and 50 Hz power supply having isolator panel with MCB at cooling tower and with following technical data:- (a) Water flow/tower - As per design (b) Ent water temp 97 deg F (c) Basin water temp 90 deg F
(vii) Piping - Chilled water Supply laying/fixing testing and commissioning the following nominal sizes of chilled plumbing pipes MS 'C' class as per IS 1239 inside the building (with necessary clamps, vibration isolators and fitting like valves, flanges union etc but excluding valves, strainer guages etc) cut to required lengths and welded at joints and inclusive of accessories like elbows, tees, reducers socket etc including insuating with 25 mm (for all pipes) and 13 mm (for drain pipe) thick closed cell chemically across linked fire retardant polyethylene foam insulation of density 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035W/Mk at an average temp of 40 deg C, covered with aluminium faced foil complete with application with rubber based adhesive pdilite SR 998 and 50 mm x 3 mm thick self adhesive tape on both longitudinal & traverse joints simultaneouslyy all as specified:- (a) 100 mm dia MS pipes (b) 80 mm dia MS pipes (c) 50 mm dia MS pipes (d) 40 mm dia MS pipes (e) 25 mm dia MS pipes (viii) Ducting a) Air and return air ducting made all as per SMACNA standards commercial grade Gi sheet zinc coating 120 grade 24 guage including 25mmx4mm angle iron supports, 10 mm dia rods, anchor fastener, fittings, joints including 3 mm rubber gaskets and nuts & bolts for jointing the ducts complete al as per IS-655 specified and directed - 01 Lot (b) Air and return air ducting made all as per SMACNA standards commercial grade GI sheet zinc coating 120 grade 22 guage including 25mmx4mm angle iron supports, 10 mm dia rods, anchor fastener, fittings, joints including 3 mm rubber gaskets and nuts & bolts for jointing the ducts complete al as per IS-655 specified and directed - 01 Lot Make for (a) & (b) SAIL/TATA/JISC/JINDAL (c) Acoustic insulation with 12 mm thick fibre glass rigid boards covered with tissue paper and MS wire mesh and finished with RP tissue paper and 28 gauge aluminium perforated sheet and upto 5 metre from AHU canvas connection complete all as specified and directed - 01 Lot. Make:- SPINTEX/UPTWIGA/FGP/LLYODS/BEARD SHELL
(d) Thermal insulation to duct in non air conditioned spaces with 50 mm thick fibre glass wool density 48 Kg/Cum, covered with polythene sheet faced hessain cloth, GI chicken wire mesh and protected with 28 gauge aluminim foil cladding complete all as per IS -655 as specified and directed. Make:-SPINTEX/UPTWIGA/FGP/LLYODS/BEARD SHELL/LLYODS (e) Supply air diffuser/grills with coller damper complete all as specified and directed. - 01 lot (f) Return air diffuser/grills with coller damper complete all as specified and directed. - 01 lot (g) Volume control dampers of GSS opposed blade construction including energy effecient motor of suitable capacity complete with flanges channel and control lever suitable for duct mounting - 01 lot (h) Fire dampers automatic type with fusible link (CPRI certified) and operated with stainless steel spring made out of 16 SWG GI sheet to be provided in main supply duct interlocked with AHU motor to cut off circulation of air in case of fire as required for satisfactory completion of work as per site requirement. (j) Air vent as required for satisfactory completion of work - Quantity as required . (k) In built stifuers to maintian noise level from AHU to condition room of conmmercial grade VIII as per IS 655 including plenum air chamber complete. Note:- AC duct shall be designed and submitted by the contractor before commencement of work. The approval shall be obtained from Accepting Officer,. The cost of designing, drawing is deemed to be included in quoted rates.
(ix) Supply laying/fixing testing and commissioning the following nominal sizes of chilled plumbing pipes MS 'C' class as per IS 1239 inside the building (with necessary clamps, vibration isolators and fitting like valves, flanges union etc but excluding valves, strainer guages etc) cut to required lengths and welded at joints and inclusive of accessories like elbows, tees, reducers socket etc including insuating with 25 mm (for all pipes) and 13 mm (for drain pipe) thick closed cell chemically across linked fire retardant polyethylene foam insulation of density 30 Kg/cum. The thermal conductivity of the material should not exceed 0.035W/Mk at an average temp of 40 deg C, covered with aluminium faced foil complete with application with rubber based adhesive pidilite SR 998 and 50 mm x 3 mm thick self adhesive tape on both longitudinal & traverse joints simultaneouslyy all as specified:- (a) 100 mm dia MS pipes (x) Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), double layered, 500 litres capacity, hoisted and fixed in position and totally insulated with 50 mm thick fibre glass wool density 48 Kg/Cum, covered with polythene sheet faced hessian cloth, GI chicken wire mesh and protected with 28 gauge aluminum foil cladding all as specified in SSR Part-I, complete including suitable size float valve, overflow vent, drain vent ect all as speciifed and directed - 01 No.
Supply, installation, commissioning and testng of LT indoor type FP 65 panel board (factory made of approved CPRI) of size not less than 150cmx100cmx50cm fabricaated of CRCA sheet 2 mm thick rust proof, powder coated from both side, individual door factory locking system with two side ventilation suitable for working on 440V, 50Hz AC supply including Bus bar chamber and copper bus of capacity 400 Amps rating for phase and neutral mounted on hygroscopic insulator fixed in refarate bus bar chamber, separate compentment for incoming and outgoing feeder prewired with suitable size of copper conductor cable including fitted on 50x50x6xcm angle iron channel & 04 Nos angle iron legs with PCC foundation 1:2:4 using 20 mm graded stone aggregate & provn of lugs & bushing for housing the following:- (i) Electrolite copper bus bar 400 amps for phase & neutral - 04 Nos (ii) MCCB 4P 400 Amps, 35 KA - 01 No (Incomiing) (iii) MCCB 4P 400 Amps, 35 KA- 01 (Outgoing for AC Plant) (iv) Multi functional digital voltmeter and ampere meter including suitable and appropriate CTs - 01 Set (v) Indicator lamp (LED R-Y-B) - 01 Set
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm with & including GI pipe 40mm bore light grade as protection pipe (upto the body of equipment max 7.50 metre) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of coal dust and common salt 15cm thick, all around top and bottom and watering pipe 20mm bore of GI pipe medium grade with funnel and wire mesh complete all as shown in Electrical plate No. 3 of SSR Part-I (2009), testing on completion including PCC chamber (1:3:6) using 20mm graded stone aggregate, RCC M-25 (Design mix) cover, angle iron frame and necessary earth work complete all as specified with the following :- (a) Test point GI for size 75mm x 75mm x 25mm (b) Watering pipe GI light grade 20mm dia from top of the earth electrode upto MS funnel with bras wire mesh embedded in floor of PCC earth pit. (GI funnel should properly tightened on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits. (c) PCC earth pit 30cm x 30cm constructed in PCC (1:2:4) type B-1 exposed surfaces smoothly finished with 15mm thick cement mortar (1:6) plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
(d) Angle iron frame made of 40 x 40 x 4mm angle iron for 30 x 30mm PCC pit for holding the pit cover. Note :- 1. The unit rate shall include for protection pipe GI water pipe, wire mesh, funnel, excavation, RCC pit cover, test point, GI strip of size 32 x 6mm from the earth plate and upto metallic body of the quipment/ panel board etc. 2. PCC pit shall be provided at least 0.50 metres away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction elbow etc shall be deemed to be included in the unit rate. 3. RCC pit cover shall be 80mm thick RCC M-25 (Design mix) reinforced with XPM weighting not less than 4 Kg/sqm.
MANNING AND OPERATION OF AIR CONDITIONING PLANT WORKS (SCH 'A' PART-XVII)
Manning and operation of Air conditioning plant and DG set during defect liability period of 12 months from the actual date of completion including operation of DG Set, compressors, condensers, AHU Unit, cooling tower ,pipe line, pumps including operation of valves complete by providing/ Deploying all required supervisory, Technical Staff and required number of Helper but minimum as following :- (i) Refrigeration mechanic - 02 Nos per shift of 08 Hrs (ii) Helper - 02 Nos per shift of 08 Hrs Notes :- (a) Quantity is variable and shall be calculated actually for 12 months period of completion as given. (b) The operator shall be ITI certificate holder from recognized board having minimum two year experience in similar Job/ trade in Refrigeration and Air Conditioning with 2 year experience in relevant field, responsible for plant operation and maintenance round the clock including Sunday and Holiday. (c) Helper to assist the refrigeration mechanic (minimum 10th pass) responsible for AC Plant/ Parts cleaning, cleaning surrounding area and carry necessary T&P from smooth functioning of plant, operation and maint around the clock including Sunday and Holiday. (d) The contractor shall submit name of persons to be deployed at work alongwith their qualifications and experience for approval from GE before the date of commencement of work. (e) Subsequently action for verification of antecedents of the persons to be deployed shall be taken by the contractor and submit the same to Engineer-in-Charge/ GE within 07 days from the date of commencement of work (f) Cleaning of area in and around pump houses & common areas (viz cutting of grass & disposal of debris) are deemed to be included in the scope of the work. Default if any noticed in duty of cleaning, recovery will be imposed as per clause specified in the Particular Specifications. (g) Per shift shall be of 08 Hrs
M/S Shiv Shakti Enterprises (BID ID -3144400)
Elite Builders (BID ID -3127841)
MASTER CONSTRUCTION CO (BID ID -3142707)
L G BUILDERS (BID ID -3142466)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .