| 1 | L1₹8.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.5 L+₹25,020 (3.05%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹8.5 L+₹30,405 (3.71%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹8.6 L+₹35,551 (4.33%)Rejected-Finance | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹8.6 L+₹37,245 (4.54%)Rejected-Finance | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
8 Jul 2021, 6:00 pmClosed
GE 867 EWS
GE 867 EWS C/O 99 APO PIN 913867
REPAIRS TO INTERNAL ELECTRIFICATION AND CONNECTED WORKS AT PEDONG, ALGARAH, DALAPCHAND, AP ALGARAH AND TEESTA TCP UNDER GE 867 EWS
2021_MES_450933_1
CA NO GE / 867 / TOKEN / 21 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Pedong
Refer Tender Documents
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹15,000
Yes
7 Oct 2021
12 Jun 2021
9 Jul 2021
12 Jun 2021
8 Jul 2021
26 Jun 2021
12 Jun 2021 - 19 Jun 2021
Amount
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of size not lee than 25mm with all necessary fittings, fixed on walls/ceilings etc., including 1.5 Sq mm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in PVC terminal boxes concealed type/surface type for housing switches, socket outlet, regulator etc., for one light /fan point controlled by one switch/one bell / buzzer point controlled by one bell push/one 3 / 5 -pin switch socket outlet 5 amps on independent board including taking down existing unserviceable point wiring terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge.
All as per item No. 1 above but for One 3/5 pin switch socket outlet 5 amps on same board along with other switches complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 2.5 Sqmm (nominal area) PVC insulated un - sheathed single core stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of size not less than 25mm with all necessary fittings, fixed on walls/ceilings etc., including 2.5 Sqmm PVC insulated copper conductor FRLS cable for earth continuity conductor and connected to earth dolly and to be terminated in PVC terminal box concealed type/surface type for housing switches, socket outlet, regulator etc., for one 5 / 6 -pin switch socket outlet 15 amps on independent board including taking down existing unserviceable point wiring including terminal boxes and making good disturbed surfaces including testing on completion complete all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring complete with 2 runs of 6 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor and drawing through and including rigid non metallic PVC casing and capping of size not less than 25mm fixed on wall/ceiling and connecting terminal ends including provision of 1 run of 6 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor as earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring and making good disturbed surfaces complete all as directed by Engr-in-charge. Note: 2 runs of 6 Sqmm and one run of 6 Sqmm and one run of casing capping shall be measured as one unit length.
M&L for sub main wiring complete with 2 runs of 4 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor and drawing through and including rigid non metallic PVC casing and capping of size not less than 25mm fixed on wall/ceiling and connecting terminal ends including provision of 1 run of 4 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor as earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring and making good disturbed surfaces complete all as directed by Engr-in-charge. Note: 2 runs of 4 Sqmm and one run of 4 Sqmm and one run of casing&capping shall be measured as one unit length. Make for Item No. 1 to 5 Cable: (i) Finolex, (ii) Plaza, (iii) Havells, (iv) Polycab, (v) KEI, (vi) Anchor Conduit: (i) Kinjal, (ii) Alwyn (iii) Harsh, (iv) Finolex (v) Berlia (vi) Plaza
S&F in repairs switch piano, flush button, single pole, 5 amps, one way complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs switch socket combination 2 – in – one, 3 Pin / 5 Pin, 5 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs switch socket combination 2 – in – one 6 Pin , 5 / 15 amps flush type complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs ceiling rose 3 terminal /PVC/Polycarnonate, isolated body complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs lamp holder, PVC/polycorbonate insulated body with back plate for batten fittings complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 6 to 10: (i) Anchor (ii) Plaza, (iii) Havells (Crabtree) (iv) ABB (v) Shalabh
S&F sheet metal enclosure DB SPN 8 way 240 V with 200 Amp rated bus bar, powder coated double door including taking down old unserviceable DB complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosure DB SPN 4 way 240 V with 200 Amp rated bus bar, powder coated, double door including taking down old unserviceable DB complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SPN 40 Amps, 10 KA breaking capacity, 240 volts, 50 Hz including taking down old unserviceable MCB complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of MCB SP 6 to 32 Amps, 10 KA breaking capacity, 240 volts, 50 Hz including taking down old unserviceable MCB complete all as specified and as directed by Engineer-in-Charge. Make for Item No. 11 to 14: Legrand / Siemens/Schinder/L&T.
S & F in replacement Regal batten box type suitable for LED T-8 tubular lamps, connector block, bipin holder,PVC square block etc. complete with all accessories internally pre wired including fixed with 02 Nos of PVC round/square block screws etc., and connecting up with PVC insulated 2 core, 0.5 sqmm copper conductor from connector to ceiling rose including taking down existing fitting and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge. Make: Crompton cat part No. IGP131LT8-16 or equivalent model of Philips/Wipro/Havells as approved by GE.
S & F in replacement energy efficent linerar LED tube light T8 tubular lamp with extruded aluminium body, PC diffuser and with inbuilt driver of 1 x 20 watt Ultra bright LED Tube light with very high efficacy suited for installation in box type batten including taking down existing tube light complete all as specified and as directed by Engineer-in-Charge. Make: Crompton cat part No.LTT8-20 or equivalent model of Philips/Wipro/Havells as approved by GE.
S&F in replacement LED bulk head fitting, 10 watt, compact, ultra low energy, modern design utility bulkhead suitable for indoor and outdoor applications with IP 65 protection. complete and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 V, 50 HZ and mounting on PVC rectaangular board of 200mm x 250mm including dismantling unserviceable light fittings and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge. Make: Crompton ( Cat No LBH-10-CDL) or equivelent in Havells/Philips as approved by GE.
Supply and fixing in replacement of 36 watt LED edge lit luminare of 3000K 600 mm x 600 mm suItable for armstrong/grid ceiling complete including electronic driver including taking down existing fitting and making good disturbed surfaces complete all as specified and as directed by Engineer-in-Charge. Make: Havells cat part No.VENUSNEOHE2X2PLR18-42WLED830MOD for Panel, LEDDRIVER36V36WS for 36 Watt LED driver or equivalent model of CG/Philips as approved by GE.
Supply and fix in repairs 1.5 KW capacity Heating Element, triangular type with ‘necessary washer including making electrical connection complete all as directed by Engineer-in-Charge.
Supply and fix in repairs 2.0 KW capacity Heating Element, triangular type with ‘necessary washer including making electrical connection complete all as directed by Engineer-in-Charge. Make for Item No. 19&20: Bajaj/Venus/Racold/Havells/Crompton/Power pack/Jilco or equivalent as approved by GE.
Supply & Fix in repairs Thermostat switch overheat cut off type for geysers 25/ 50 Ltr capacities including making connection complete all as directed by Engineer-in-Charge.
Supply and fixing PVC connection heavy duty with brass /PTMT nuts of reqd |ength not exceeding 300 mm with rubber/ PVC washer suitable for 15 mm bore GI pipe for cold water complete all as specified & directed by Engineer-in-Charge. Make:- PRAYAG/POLYTUFF or equivalent as approved by GE.
Supply & fixing in replacement 300mm long chromium plated copper pipe connection (Heavy Duty) with two numbers brass adopters for fixing one end at geyser & other end at water outlet point for hot water complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement indicator lamp round /rectangular and making electric connections (Red/Green) 220 Volts AC as per site requirement suitable for geysers complete all as directed by Engineer-in-Charge.
Taking down existing unserviceable service cable of any size and S&F 1100 volts grade heavy duty PVC insulated stranded aluminium conductor cable of cross-sectional area 6 Sqmm size (one twin core cable flat or circular, served with inner sheathing of PVC tape and overall PVC sheathed) in service connections, suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire and testing on completion complete all as specified and as directed by the Engineer-in-Charge. MAKE:- ANCHOR/FINOLEX/PLAZA/ HAVELLS/ HPL/ POLYCAB/KEI
Taking down existing unserviceable service cable of any size and S&F 1100 volts grade heavy duty PVC insulated stranded aluminium conductor cable of cross-sectional area 10 Sqmm size (one twin core cable flat or circular, served with inner sheathing of PVC tape and overall PVC sheathed) in service connections, suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire and testing on completion complete all as specified and as directed by the Engineer-in-Charge. MAKE:- ANCHOR/FINOLEX/PLAZA/ HAVELLS/ HPL/ POLYCAB/KEI
Sub Total of Schedule 'A'
Schedule of Credit (Minus) Rs. 16,159.00 B/F from Ser page No. 25 NOTE: Bidder shall insert credit amount as rate Rs. 16,159.00 in Green field under Col-M. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender.
Sub Total of Schedule of Credit
SANJAY SAW MILL
G K SUTHAR
MS MAYA PRAKASH GOEL AND SONS
DEEP CHANDRA JOSHI
GEETA CONSTRUCTION
MANOJ JINDAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .