Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 CrAccepted-AOC | ₹4.8 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹5.1 Cr+₹27.4 L (5.73%)Rejected-Finance 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | ₹5.1 Cr+₹27.4 L (5.73%) | L2 | Rejected-Finance Other than Lowest |
| 3 | L3₹5.2 Cr+₹45.8 L (9.59%)Rejected-Finance JODHPUR ROAD UTARLAI BARMER RAJ 344035 | BARMER | RAJASTHAN | 344035 | ₹5.2 Cr+₹45.8 L (9.59%) | L3 | Rejected-Finance Other than Lowest |
| Sl No | Description | Qty | Unit | Pioneer Enterprises L2 | M/s PRABHU DAN DETHA AND COMPANY L1 | M/s godara infratech and power industries L3 |
|---|---|---|---|---|---|---|
| 1.00 | B&R.WORK Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/disintegrated rock complete all as specified and directed by Engineer-in-charge. | 141.12 | SQM | 100 ₹14,112 | 20 ₹2,822.4 | 15 ₹2,116.8 Lowest |
| 2.00 | Excavation over areas n.exc 1.5m depth and getting out in soft/ disintegrated rock complete all as specified and directed by Engineer-in-charge. | 20 | CUM | 800 ₹16,000 | 350 ₹7,000 | 150 ₹3,000 Lowest |
| 3.00 | Excavation over areas exc 1.5m and n.exc 3m depth and getting out in soft/ disintegrated rock complete all as specified and directed by Engineer-in-charge. | 11 | CUM | 1,000 ₹11,000 | 600 ₹6,600 | 225 ₹2,475 Lowest |
| 4.00 | Excavating in trenches, not exc. 1.5m wide and not exc. 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/ disintegrated rock complete all as specified and directed by Engineer-in-charge. | 750.87 | CUM | 850 ₹6,38,239.5 | 500 ₹3,75,435 | 150 ₹1,12,630.5 Lowest |
| 5.00 | Excavating in trenches, exc 1.5 m deep and getting out in soft disintegrated rock complete all as specified and directed by Engineer-in-charge. | 106.98 | CUM | 1,050 ₹1,12,329 | 500 ₹53,490 | 300 ₹32,094 Lowest |
| 6.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft/ disintegrated rock complete all as specified and directed by Engineer-in-charge. | 323.55 | CUM | 100 ₹32,355 | 200 ₹64,710 | 65 ₹21,030.75 Lowest |
| 7.00 | Removing excavated rock material to a distance n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge. | 305.96 | CUM | 180 ₹55,072.8 | 200 ₹61,192 | 65 ₹19,887.4 Lowest |
| 8.00 | M&L PCC 1:4:8 (Type D2) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-charge. | 58.73 | CUM | 5,000 ₹2,93,650 | 4,200 ₹2,46,666 | 4,000 ₹2,34,920 Lowest |
| 9.00 | M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in foundations, including rafts, footing foundation beams, plinth beam, base for coulm, etc basement slab under ream piles and mass concrete complete all as specified and directed by Engineer-in-charge. | 115.25 | CUM | 8,000 ₹9,22,000 | 6,200 ₹7,14,550 | 6,000 ₹6,91,500 Lowest |
| 10.00 | M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in Col, Pillars post and struts etc complete all as specified and directed by Engineer-in-charge. | 17.2 | CUM | 8,700 ₹1,49,640 | 7,000 ₹1,20,400 | 6,000 ₹1,03,200 Lowest |
Tender Value
₹5.0 Cr
EMD Value
₹5.7 L
Closing Date
21 Oct 2025, 6:00 pmClosed
CWE (A) Jaisalmer
HQ CWE ARMY JAISALMER 345001 RAJASTHAN
PROVN OF SOLID WASTE MANAGEMENT AT JAISALMERMIL STATION UNDER GE (A) JAISALMER. (JOB No. 01/AMWP/2024-25/Q)
2025_MES_728173_1
84345/C/E8
Open Tender
Civil Works
Item Rate
240 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹2,000
GE ARMY JAISALMER
₹5.7 L
Yes
CWE (A) Jaisalmer
27 Dec 2025
28 Aug 2025
23 Oct 2025
28 Aug 2025
21 Oct 2025
15 Oct 2025
28 Aug 2025 - 4 Sept 2025
6 Sept 2025
Amount
B&R.WORK Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/disintegrated rock complete all as specified and directed by Engineer-in-charge.
Excavation over areas n.exc 1.5m depth and getting out in soft/ disintegrated rock complete all as specified and directed by Engineer-in-charge.
Excavation over areas exc 1.5m and n.exc 3m depth and getting out in soft/ disintegrated rock complete all as specified and directed by Engineer-in-charge.
Excavating in trenches, not exc. 1.5m wide and not exc. 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/ disintegrated rock complete all as specified and directed by Engineer-in-charge.
Excavating in trenches, exc 1.5 m deep and getting out in soft disintegrated rock complete all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft/ disintegrated rock complete all as specified and directed by Engineer-in-charge.
Removing excavated rock material to a distance n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
M&L PCC 1:4:8 (Type D2) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in foundations, including rafts, footing foundation beams, plinth beam, base for coulm, etc basement slab under ream piles and mass concrete complete all as specified and directed by Engineer-in-charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in Col, Pillars post and struts etc complete all as specified and directed by Engineer-in-charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as in beams, cantilever, bressummers, lintel over 1.5m span etc complete all as specified and directed by Engineer-in-charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate)e as on Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs andd in shelves and the like complete all as specified and directed by Engineer-in-charge.
M&L RCC (Design Mix) M-25 (using 20 mm graded stone aggregate) as for chajjas complete all as specified and directed by Engineer-in-charge.
M&L of formwork to sides of concrete foundation ,footing,base of column ,raft beams , sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter to rough finish surface of concrete flat complete all as specified and directed by Engineer-in-charge.
M&L of formwork to soffits of suspended slabs such as roof slabs ,floor slabs ,landing and similar work not exc 200mm thick (Horizontal or sloping) to rough finish surface of concrete flat complete all as specified and directed by Engineer-in-charge.
M&L of formwork to soffits of floor or roof beams, beam haunching ,grider, bressumber, lintels,cantilever ,sleves including supports ,over hang etc also splay between floor and beams to rough finish surface of concrete flat. complete all as specified and directed by Engineer-in-charge.
M&L of formwork to sides of pillars, posts ,struts piers ,columns and stanchion to rough finish surface of concrete square ,rectangular or polygonal. complete all as specified and directed by Engineer-in-charge.
M&L of formwork tochullah hoods, chajjas, troughs and similar items including edgescomplete complete all as specified and directed by Engineer-in-charge.
M&L of formwork to edges of concrete flats ,treads, break in floors window cills, concrete railing , opening in concrete wall, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls , horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide to rough finish surface of concrete flat. complete all as specified and directed by Engineer-in-charge.
M&L for TMT mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete all as specified and directed
All as per Item No. 20.00 here-in-before above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by Engineer-in-charge.
M&L for Plates (plain or chequered) Fe 410-W(Gde E-250) quality A in channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed by Engineer-in-charge.
M&L for Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections Fe 410-W(Gde E-250) quality 'A' complete all as specified and directed by Engineer-in-charge.
S&F for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm but not.exc 30 cm long,diameter of neck 16 to 20 mm complete all as specified and directed.
M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St-240 complete all as specified and directed by Engineer-in-charge.
M&L for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed by Engineer-in-charge.
S&F pre-painted Galvalume aluminium zinc coating GI based corrugated steel sheet/ semi corrugated 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
S&F Pre painted Galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
S&F for steel rolling shutters, 1.25mm thickness of laths with out ball bearing,but gear operated type with bevel gear box and crank handle as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-charge.
M&L squared rubble masonry Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified and directed by Engineer-in-charge.
M&L squared rubble walling Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge.
Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exc 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses complete all as specified and directed by Engineer-in-charge.
M&L for brick work with fly ash bricks modular brick size straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick cement plaster in CM 1:6 on fair faces of brick/concrete work surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for rendering 5 mm tk on fair faces of concrete surface in ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick cement plaster in CM 1:4 on fair faces of brick/concrete work surfaces finished even and smooth without using extra cement including water proofing compound complete all as specified and directed by Engineer-in-charge. NOTE : water proofing compound paid seperately.
Supply only integral water proofing compound (ISI Marked) complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces and applying three coat of white wash on ceiling complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered /unplastered surfaces and applying two coat of cement base paint over a coat of alkal resistant primer complete all as specified and directed by Engineer-in-charge.
M&L preparation of newly plastered /unplastered surface of wall and apppying two coat of oil bound distemper over a coat of 1mm thickness plaster of paris putty complete all as specified and directed by Engineer-in-charge.
M&L for 50 mm thick cement concrete 1:2:4, type B-1(20mm graded aggregate)in finishing course to flooring & pavings finished even and smooth withouth using extra cement complete all as specified and directed by Engineer-in-charge.
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-charge.
M&L for Glass dividing strips, 3 mm thick, 28mm width and inserted in position, conform to design complete all as specified and directed by Engineer-in-charge.
M&L for hardcore of guage n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface with broken stone boulders complete all as specified and directed by Engineer-in-charge.
M&L broken stones or boulder for loose filling with aggregate of gauge 40 to 80mm in soakage pit and soaksge wells complete all as specified and directed by Engineer-in-charge.
M&L for providing 200 mm thick PCC 1:2:4, type B-2 (using 40 mm graded stone aggregate ) as in sub base of flooring complete all as specified and directed by Engineer-in-charge.
M&L for providing 50 mm thick PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate ) as in sub base of flooring complete all as specified and directed by Engineer-in-charge.
M&L for providing 75 mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate ) as in sub base of flooring complete all as specified and directed by Engineer-in-charge.
M&L for 25 mm thick cement concrete type B-0 (1:2:4) using 12.5 mm graded aggregate as in floor for receiving screed bed complete all as specified and directed by Engineer-in-charge.
M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection and hard standing including providing contraction joints with wooden spacers complete all as specified and directed by Engineer-in-charge.
M&L for vitrified ceramic coloured tiles 9 to 10 mm thick area of each tile not exc 0.36 sqm in floors etc set and including jointed in neat cement slurry and pointed in coloured cement over 15mm thick screed bed in CM 1:6 provided with 3mm thick joints accomplished by providing PVC spacers and joints filled with epoxy filling complete all as specified and directed by Engineer-in-charge.
M&L for vitrified ceramic coloured tiles 9 to 10 mm thick area of each tile not exc 0.36 sqm in Skirting/dado over 10mm thick in CM 1:4 backing coat provided with 3mm thick joints accomplished by providing PVC spacers and joints filled with epoxy filling complete all as specified and directed by Engineer-in-charge.
M&L for non Skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick in (1:6) for laying floor finishes like tiles etc complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including rendering 10 mm thick cement plaster in CM 1:4 for fixing vertical tiles complete all as specified and directed by Engineer-in-charge.
S & F Steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed by Engineer-in-charge.
S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete with glazing bars complete all as specified and directed by Engineer-in-charge.
M&L for 3mm thick sheet glass pin head type and glazing with oil putty in square n. exc 0.50 sqm each pane complete all as specified and directed by Engineer-in-charge.
M&L for pin headed/figured Sheet glass 4mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 sq. m in each pane complete all as specified and directed by Engineer-in-charge.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engineer-in-charge.
S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bbottom rail; Panelling of wood grain printed PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed by Engineer-in-charge.
S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of New or previously untreated wood and wood based surfaces of any description over 10cm in girth or width and painting with two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed by the Engineer-in-Charge.
S&F Mild steel work in framed work such as grills, gratings, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe290-Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 150mm Aluminium handles , cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F butt hinges, extruded alluminium,with mild steel hinge pin,bright polished and fixed, type 100mm size C21 complete all as specified and as directed by the Engineer-in-Charge.
S&F Aluminium alloy, anodised, sliding door bolt 200mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
S&F GI tubing 15 mm bore (ISI) marked) medium grade with all fitting and fixed complete to wall ceiling or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S&F GI tubing 20 mm bore (ISI) marked) medium grade with all fitting and fixed complete to wall ceiling or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S&F 15mm bib tap long body fancy type cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 25 mm bore stop valve cast copper alloy screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed by the Engineer-in-Charge.
S&F vitreous china wash down water closet pedestal pattern including connecting to flush tank with flush pipe, seat cover of the same make as that of closet complete all as specified and as directed by the Engineer-in-Charge.
S&F Vitreous china wash basin, white, flat back, size 550 X 400 mm excluding taps, chain and plug and porcelain stopper but including CP waste coupling & brackets and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 10 ltrs capacity PVC low level flushing cistern with inlet, ball valve, float, handle including fitting and fixtures and providing connections to WC and flush pipe without any damage to the existing fittings, complete all as specified and as directed by the Engineer-in-Charge.
S&F 15 mm dia Stop valves, cast copper alloy screwed presure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed but fancy type chromium plated complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC connection 15 mm size with PTMT nuts of length 600mm complete all as specified and as directed by the Engineer-in-Charge.
S&F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or in trenches complete all as specified and as directed by the Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or in trenches complete all as specified and as directed by the Engineer-in-Charge.
S&F 75 mm bore PVC (SWR) bends of any radius with access door complete all as specified and as directed by the Engineer-in-Charge.
S & F 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and as directed by the Engineer-in-Charge.
S & F 75 mm bore PVC (SWR) Vent Cowl complete all as specified and as directed by the Engineer-in-Charge.
S & F 110 mm bore PVC (SWR) Vent Cowl complete all as specified and as directed by the Engineer-in-Charge.
M&L for APP based polymeric membrane minmum weighing 3 Kg/Sqm and minmum 3 mm thick reinforced with polyster non wove fabric ( wt not less than 150 gms/sqm) including priming of surface by forced application including 10mm thick screed bed 1:3 CM with water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
M&L Bitumen blown any grade, applied hot, two coats, to concrete surfaces at the rate of 1.5kg. per sq. m per coat complete all as specified and as directed by the Engineer-in-Charge.
M&L for PCC (1:2:4) B-0 using 12.5 mm graded stone aggregate as in levelling padding course over RCC roof surface including rounded or chamferred on edges etc., to achieve requisite slope complete all as specified and as directed by the Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tanks 1000 litres capacity triple layered (White) cylindrical vertical with closed top hoisted including 20mm ball valves high pressure with polythene float and flynut complete fixed in position including dismantling water tank and removing to store of any description complete all as specified and as directed by the Engineer-in-Charge.
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation of manholes, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L for brick work with fly ash modular size bricks of class designation 75 (kgf/ sqcm) bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in Coping incl necessary form work finished even & smooth with using pigment in cement complete all as specified and as directed by the Engineer-in-Charge.
M&L for PCC 1:2:4 type -B1 (using 20mm graded stone aggregate ) as in surface channaels and drain etc complete all as specified and as directed by the Engineer-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds, mitered /stopped ends etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for PCC (1:4:8) type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 150mm bore pipe complete all as specified and directed by Engineer-in-charge.
M&L for sand stone slabs 75mm thick in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L for sand stone slabs 5cm thick in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L for 150mm bore reinforced concrete pipes, class NP-2 (ISI marked) including collars laid in trenches and jointed complete complete all as specified and directed by Engineer-in-charge.
M&L for Precast cement concrete 1:3:6 type C1 (Using 20 mm graded granite stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:3:6) type C1 using 20mm graded stone aggregate as in bands, string course coping apex stone bed plate kerbs and the like including weathering , slightly rounded or chamfered angle with and incl necessary use and waste of form work complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in benching of drain complete all as specified and directed by Engineer-in-charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removing surplus soil to a distance n.exc 50 m in soft/disintegrated rock complete all as specified and directed by Engineer-in-charge.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed by Engineer-in-charge.
M&L for hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-charge.
Supply only chain link MS galvinised fencing of any size and type complete all as specified and directed by Engineer-in-Charge. Note :- This item shall be measured and paid as per actual weight or standard weight as per SSR which ever is less.
Fixing only chain link fencing including line wire, any mesh, size and any type of standards rails straining bolt etc including provision of binding wire complete all as specified and directed by Engineer-in-Charge.
S&F MS 10mm dia round bars as line wire for chain link fencing complete all as shown on drawing complete all as specified and directed by Engineer-in-Charge.
M&L for 5 to 10mm dia mild steel screw bolts (Machine made) with hexagonal or square head at one end and screwed the other or screwed both ends each screwed and to be bolted with washers and one hexagonal or square exc 50mm long and not exc 100mm long & dia of neck 11 to 15mm including fixed with welding to angle complete all as specified and directed by Engineer-in-Charge.
S&F for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and training and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed by Engineer-in-charge. Note - Each line wire to be measured
E&M WORK M&L for light/fan point wiring pvc insulated unsheathed FRLS 1100 volts grade cable as per IS 694 with valid CML No with multistranded copper conductor cable of nominal cls area 1.5 sq mm each for phase ,neutral and earth drawn and including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for conduits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc as earth continuity conductor connected to common earth complete all as specified and directed by Engineer-in-Charge for the following :- Note:- Modular switch and socket shall be measured and paid separately.
All as per Item No.111.00 here in before above but for One light point controlled by one way switch complete all as specified and directed by Engineer-in-Charge.
All as per Item No.111.00 here in before above but for One Ceiling Fan/Exhaust fan point controlled by one way switch complete all as specified and directed by Engineer-in-Charge.
All as per Item No.111.00 here in before above but with copper conductor cable of nominal class area 2.50 sq mm for phase ,neutral & earth One 2/3 pin socket outlet 5Amps on independent board complete all as specified and directed by Engineer-in-Charge.
All as per Item No.111.00 here in before above but with copper conductor cable of nominal class area 4.0 sq mm for phase ,neutral & earth for power socket point complete all as specified and directed by Engineer-in-Charge.
S&F switch Modular switch 1 way 6A, 1 module single pole complete all as specified and directed by Engineer-in-charge.
S&F modular Socket, 6A - 2/3 pin combined 2 module, ISI Marked with valid CML No complete all as specified and directed by Engineer-in-charge.
S&F Modular Switch socket Combination 6A/16A, 5/6 pin, 3 module ISI Marked with valid CML No complete all as specified and directed by Engineer-in-charge.
S&F ceiling rose surface bakelite 3 terminals 230 Volts AC with polycarbonate body complete all as specified and directed by Engineer-in-charge.
S&F for sheet metal enclosure MCB SPN DB 8 way made out of 1.5 mm thick sheet metal enclosure IP 43 with 200 Amps rated bus bar 240 volts double door with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCBs and isolators etc complete all as specified and directed by Engineer-in-charge.
S&F MCB SPN 240 volts, 40 to 63 Amps, 10 KA repturing capacity C curve complete all as specified and directed by Engineer-in-charge.
S&F MCB SP 240 volts, 10 to 32 Amps, 10 KA, repturing capacity C curve complete all as specified and directed by Engineer-in-charge.
S&F 415V 10KA 'B' curve miniature circuit breaker (MCB) of TP 40 to 63 Amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 1.50 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 1.50 Sqmm (FRLS) of continous earth wire green in colour complete and including complete all as specified and directed by Engineer-in-charge. Note :- Two runs of 1.50 Sqmm cable & one run of 1.50 Sqmm cable continuity earth and one run of PVC conduit with all necessary accessories shall be paid as one unit length
M&L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete and including complete all as specified and directed by Engineer-in-charge. Note :- Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable continuity earth and one run of PVC conduit with all necessary accessories shall be paid as one unit length
M&L for submain wiring with approved colour code/as per IS (Red,yellow,blue,black & green for three phase) concealed conduit circuit with four single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 10.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 10.00 Sqmm (FRLS) of continous earth wire green in colour complete and including complete all as specified and directed by Engineer-in-charge. Note :- Four runs of 10.00 Sqmm cable & one run of 10.00 Sqmm cable continuity earth and one run of PVC conduit with all necessary accessories shall be paid as one unit length
F&F of LED box type Integrated Batten 40 watt having Aluminum Extruded housing in white powder coated Finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Dimensions of the Fitting Shall be Not less then 1200 MM ( Length) X 40 MM ( Width ) X 63 MM ( Height ). Lumens output of the fitting shall be not less then 4400 lm, CCT 5700 – 6500K, buring hours 50,000 Surge Protector 4 KV, PF>= 0.95 , Separate detachable type Electronic constant current drivers for easy replacement and maintenance, THD < 10% , Necessary mounting arrangements. The fixture shall be suitable for wall mounting /suspension mounting as per site requirement. The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM80 / Test Report complete all as specified and directed by Engineer-in-charge.
S&F energy saving, environment friendly & robust Highbay/Mediumbay roof truss light LED for covered shed 150 Watt IP65 luminaire with high efficacy with fixing arrangement such as bracket, MS clamp, Nut bolts etc and connecting complete all as specified and directed by Engineer-in-charge.
S&F Air Circulator fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting complete all as specified and directed by Engineer-in-charge.
S&F load line distribution board TPN vertical, 4 way double door type, fixed on wall semi flush with incoming MCCB 4 poles 100 Amps, 16 KA, busbars , neutral link, blanking plates complete with all accessories complete all as specified and directed by Engineer-in-charge. Note : Outgoing MCBs shall be measured and paid separately
S&F load line distribution board TPN vertical, 8 way double door type, fixed on wall semi flush with incoming MCCB 4 poles 100 Amps, 16 KA, busbars , neutral link, blanking plates complete with all accessories complete all as specified and directed by Engineer-in-charge. Note : Outgoing MCBs shall be measured and paid separately
M&L for maintenance free chemical earthing with copper plating earthing electode inner pipe dia 42mm and outer pipe dia 76mm coating thickness of 250 mircrons over the rod and 3 mtr long duly inserted in ground by making a bore hole of 250 mm dia, 16 feet deep. Earthing enhcancing compound of 50 kg in sullery form shall be poured in hole after insertion of eletrode, remaining portion of hole shall be filled with excavated earth, interconnected with copper strip of size 20x3 mm and connected by means of exothermic brazing & protected by GI pipe light grade 32 mm bore and PCC (1:3:6) type C1 earth chamber & cast iron earth pit cover 300x300x3 mm connecting to test point & testing on ground complete including excavation, earth work, boring in any type of soil strata & cleaning of site complete all as specified and directed by Engineer-in-charge. Note :- (i) Cost of copper strip 20x3 mm and 32 mm dia GI pipe light grade required for interconnection of copper plate earth electrode 76 mm dia earth electrode is deemed to be included in unit quoted rates. The unit rate includes copper strip and protection pipe upto 7.5 metre. (ii) Cost of earth work, boring, PCC earth pit, CI cover, testing of earth after completion, connecting and commissioning is deemed to be included in unit quoted rates. (iii) Marking & painting of earth pit with iron plate of suitable size is deemed to be included in unit quoted rates.
Item No. 132.00 Contd... (iv) The boring will take place for 3 meter depth & 100 mm dia for copper earth electrode pipe. Earth enhance compound to be filled around the earth electrode in 100 mm dia in 3 layers of 1 mtr each by means of PVC pipe of 100mm dia as casing/formwork. The remaining volume of bore shall be filled with clay soil (available from vicinity) in 3 layers of 1 mtr each. The PVC pipe to be removed sinultaneously. The cost of all this is deemed to be included in the quoted rate. (v) Minimum distance between each earthing is not less than 3 running meter. (vi) Testing of earthing shall be conducted and result should be less than 1.00 Ohms
S&F GI tubing light grade 32 mm dia for earthing strip protection complete all as specified and directed by Engineer-in-charge.
M&L for Earth continuity strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to DBs or any other indicated situation for loop earthing with copper strip of size 20 x 3 mm complete all as specified and directed by Engineer-in-charge.
M&L for Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB of rating 63 Amp complete all as specified and directed by Engineer-in-charge.
Machines Supply, erection, automation, testing and commissioning of Solid Waste management system as per approved layout plan consisting of following items. Note : Equipments and connected items considered separately for payment purpose.
Supply, install, testing & commisioning of Waste bailing press machine of capacity 50 to 100 Kg/hr comprising following specifications : (i) Bailing machine for pressing/ compressing products like plastic bottles, aluminium cans, disposable plastic items, etc. (ii) Vertical clamping force of bailing machine - Hydraulic type (iii) Material of the bailing machine - MS (iv) Minimum Bailing capacity of machine in ton - 50 Ton (v) Maximum cycle time per bale in minutes - upto 25 minutes (vi) Number of cylinder - 01 No (vii) Type of pump - Hydraulic gear plunger pump system (viii) Gap between bottom plate and pressing plate in mm - 1400 (ix) Minimum motor power ( in HP) - 7.5 HP (x) Minimum number of ties of rope - 02 Nos (xi) Min Volume of the Chamber (LxWXH) - 0.85 Cubic Meter (xi) Number of door - 02 Nos (xii) Minimum thickness of the body plate - 5 mm (xiii) Minimum thickness of the clamping plate - 35 mm (xiv) Minimum Cylinder Stroke Length -1100 mm (xv) Minimum oil tank capacity - 160 litres (xvi) Hand lever operated (xvii) Pressure control Module - HP/LP cutoof setting (xviii) Control system of machine - Electrical (Star delta) (xix) Minimum Warranty - 5 years Make : Krishna Engineering System (Bangalore), Shreeji Machinery (Ahmedabad), TL Pathak Group (Kolkata) or equivalent make as approved by Accepting Officer.
Supply, install, testing & commisioning of Sorting conveyer machine of capacity 576 Kg/hr comprising following specifications : (i) Min Conveyor length - 10 meters (ii) Belt width - minimum 900 x 6mm ply (iii) MOC of belt - Rubber bed of min M24 Grade belt 315/3 ply. 3mm top and 1.5 mm bottom (iv) Conveyor Structure frame - 75 x 40 channel or above (v) Motor - 2 HP, 3 phase gear box motor (vi) Motor rpm - 20-25 (vii) Side Railing - SS 304 or above (viii) Seating Facility - 6 seat (3 x 3) (ix) Bins - 240 lit HDPE / LLDPE (x) Min Drum Size - 980 x275 (L x OD) in mm (xi) Min Shaft Size - 50 mm (xii) Min Idler Size - 980 x 76 (L x OD) in mm Make : Automag India Pvt Ltd (Kothrud Pune), Mika Enterprises (Ahmedabad) , Falcon Autotech Pvt Ltd (Noida), Beacon Engineers (Nagpur) or equivalent make as approved by Accepting Officer.
Supply, install, testing & commisioning of Glass bottle shredder machine comprising following specifications: TWIN SHAFT SHREDDER OF CAPACITY 500 KG/HR :- (i) Type of Shredder - Dual shaft Shredder (ii) Application of shredder - Glass waste, Glass bottles (iii) Min capacity of shredder - 100-200 kg per hrs (iv) Hooper Loading - Conveyor (v) Type of Drive for shredder - Gear motor (vi) Type of Rotary Shaft - Cylindrical - Solid router with blades fitted (vii) Input Electrical Supply - 3 Phase (viii) Motor Power for main drive in HP @ 1440 rpm - Minimum 15 HP (7.5 + 7.5 HP) (ix) Motor class - IE2 (x) Type of control panel - Automatic PLC Based control panel with reverse and forward mechanism. (xi) Material of Housing Enclosure - Mild Steel (xii) Material of Cutter blades mounted on rotary shaft - Carbon steel (xiii) Material of Rotary Shaft - EN8 (xiv) Gear box - Foot mounted and Direct drive (xv) Motor make - CG, ABB, Kirloskar or equivalent (xvi) Minimum Hopper Input Dimension - 700 x 400 mm (xvii) Minimum Shredder Chamber Size - 500 x 300 mm (xviii) Shredder Structure with 75x40 or above 'C' channels
Item No. Contd 136.03 SINGLE SHAFT CRUSHER:- (i) Drum Size - Minimum 600 mm dia X 500 mm length (ii) Minimum Hopper Input Dimension - 700 x 400 mm (iii) Shredder Structure - Base Structure 75 x 40 C channel or above (iv) Blade set - Flat Head 100 X 50 X 4 mm (v) Main motor - Minimum 3 PH , 20 HP (vi) Sieve size - 1.2 mm SWG round bore profile of 10 mm dia (vii) Blade material - C45 (viii) Electrical Control - Star delta Starter CONVEYOR BELT FOR CHARGING AND INTERMEDIATE FEEDING :- (i) Conveyor Size - 1 m x 3 m (ii) Conveyor Base structure - M.S. Heavy Duty pipes 40x40x5 mm thickness (iii) Belt MOC - End to End type 6 M PVC, 3 ply, 3mm thickness (iv) Transmission Drive - Worm gear box (v) Electrical Control - DOL starter (vi) Min Capacity - 1 TPH (vii) Quantity - 2 No’s (viii) Motor - 3 PH , 2 HP
Item No. Contd 136.03 CYCLONE:- (i) Application - To collect the output of Crusher (ii) Min Outer chamber size - 300 mm dia x 1200 mm height (iii) Body Material - M.S. Heavy Duty ‘L’ Angle, Pipe and Sheets with chute (iv) Impeller - Built up In M.S. (v) Transmission drive - Direct (vi) Collection Bag - Built up in non transferable cloth with a volume capacity of 50 kg (vii) Motor - 3 HP 3 phase Make : Infed Bio Upakaran (Vasai Palghar), Amey Engineers, (Dombivli, Mumbai), Namibind (Delhi) or equivalent make as approved by Accepting Officer.
Supply, install, testing & commisioning of Final compost screening machine of capacity 500 Kg/Hr with following specifications : ROTATING SCREEN:- (i) Material to be screened: compost (converted from garbage) - 1000 kg/hr. (ii) Minimum overall Dimension, Screen & Length - 1150 mm x 3600 mm length (iii) Material of Construction - 6 mm perforated sheet 2 mm thick (iv) Reinforcement Section - 50 X 8 mm flat or above (v) Drive - 3HP motor with GB & chain sprocket (vi) Electrical control - Control panel with desired output, emergency switch and safety (vii) Supporting structure - 70 x 70 sq. tube 2.5 mm thick (viii) Painting & Finishing - Finish with primer and enamel paint with standard process. BELT CONVEYOR :- (i) Belt width - 600 mmx 3 ply , M24 Grade belt (ii) Centre length - 20 foot (iii) Conveyor Frame - High Strength M.S. Fabricated 40 x 40 sq. tube of 2 mm thickness (iv) Drive all equipment’s - 2 HP Geared motor of desired O/P RPM (v) Drive / Tail drum - Ø 250mm with Ø 40mm shaft at bearing step (vi) Take up - Screw type take up for belt tightening (vii) Control Panel - 3 ph , 440 V , desired o/p setting (viii) Total Capacity - 900-1000 kg/hr. (ix) Painting & Finishing - Finish with primer and enamel paint with standard process. (x) Installation and commissioning (xi) AMC/ Free Visit - 3 years after Defects Liability Period. (xii) Warranty - 5 years Make : Hind Group (Nagpur), Eco Pollutech Engineers (New delhi), A S Tehno Green Pvt Ltd (Sonepat Haryana), Krishna Engineering System (Bangalore) or equivalent make as approved by Accepting Officer.
Supply, install, testing & commisioning of Waste shredder machine of capacity 500 Kg/Hr with following specifications : (i) Type of Shredder - Dual Shaft Shredder (ii) Application of shredder - Dual Shredder for Municipal Solid Waste containing various objects such as plastic bottles, plastic waste, thrash waste, organic waste, etc…. (iii) Capacity of shredder - 5 ton per day (iv) Hooper Loading - Manual (v) Type of Drive for shredder - Gear motor (vi) Type of Rotary Shaft - Cylindrical - Solid router with blades fitted (vii) Input Electrical Supply - 3 Phase (viii) Motor Power for main drive in HP @ 1440 rpm - Minimum 10 HP (5 + 5 HP) (ix) Motor class - IE2 (x) Type of control panel - Automatic PLC Based control panel with reverse and forward mechanism. (xi) Material of Housing Enclosure - Mild Steel (xii) Material of Cutter blades mounted on rotary shaft - Carbon steel (xiii) Material of Rotary Shaft - EN8 (xiv) Gear box - Foot mounted and Direct drive (xv) Make of Motor - CG, ABB or Kirloskar as approved by Accepting Officer (xvi) Hopper Input Dimension - 700 x 400 mm (xvii) Min Shredder Chamber Size - 500 x 300 mm (xviii) Shredder Structure - Base Structure 75 x 40 C or above channel Make : Infed Bio Upakaran (Vasai Palghar), Envicare (Kheda Gujarat), Maxin India Machinery Manufacturer Pvt Ltd (Coimbatore) or equivalent make as approved by Accepting Officer.
Supply, install, testing & commisioning of Wet waste/ Food waste composting machine of capacity 500 Kg/Hr with following specifications : (i) Type of plant - Fully Automatic , Aerobic (ii) Type of waste - Domestic food waste + Horticulture Waste (iii) Type of machine - Fully Automatic (PLC Based ) (iv) Reprocessing capacity of machine in (Kgs) - 1500 to 2000 Kgs/Day (v) Process - Continuous (operation 24 x 7 hrs.) (vi) Chamber Volume (approx. Six times to reprocessing capacity of machine (ltrs) - 10000 to13000 litres (vii) Material of vessel and shaft - SS-304 of suitable thickness (viii) Material of body cover - MS with powder coating (ix) Material of structure frame - MS of suitable thickness (x) Machine should have no sharp edges, welds/ joints should not be visible out side (xi) Gear motor (BEE star rating ) - 3 (xii) Gear motor - 15.HP Make : CG, ABB, Kirlosker or Equivalent amke as approved by Accepting Officer Planetary gear box (Direct drive) 10 rpm Standard or Equivalent (xiii) Gear motor of reputed make / BIS/ISO quality parts should be used Manufacturer Certificate required (xiv) Heating system - Thermic oil, Heating syterm( 6KW) (xv) Dimension of machine - 15.0 x 6.0 x 10.0 ft or as suitable (xvi) Power Consumption (KW) - Max 35 Kw for 1500 kgs reprocessing capacity (xvii) Power requirement - 440 V / 50Hz, 3 Phase (xviii) Capacity Twin shaft Shredder (Kg/hr) - 500kg / hr.
Item No. Contd 136.08 (xix) Material of Blade of Twin Shaft Shredder - Carbon Steel ; 08 mm Thickness (xx) Twin shaft /shredder - BBL or equivalent Motor: 5HP+5HP; 02 Nos. Motor & Gear Box ; worm Type Gear Box ; SS Hopper with Cover ; Application : Organic Waste Shredder (xxi) Organic De-Watering - Screen & Screw SS 304, In-Line Helical Type Gear Box ; 7.5HP BBL Make Motor (xxii) Feeding Conveyer to Shredder Machine - Structure SS 202; Plain PVC belt Thickness 3mm ply, V -type VFD Operated (xxiii) Feeding Conveyer to Dewatering to Compost machine - Screw Type Close Conveyer; Screw & Shaft SS 202; Body Cover SS 202 (xxiv) Treatable items - Fruits, fruits peels, vegetables, Vegetable peels, Fish, Fish Bones, Chicken Bones, Bread, Curries, garden waste. (xxv) Output - Dry Organic manure / Soil Additive / Compost (xxvi) Untreatable items - Coconut Shells, Metal waste, plastic glass, Big bones, large shells, petrochemicals etc. Make : Envicare (Kheda Gujarat), Ecobot, Smart Enviro systems or equivalent make as approved by Accepting Officer.
Supply, install, testing & commisioning of Incinerator machine of capacity 25 kg/Hr with following specifications : (i) Type of incinerator - Electric (ii) Material of outer body - Mild steel (iii) Material on Inner chambers (Primary & secondary) - Mild Steel (v) Min Primary Chamber volume - 0.25 Cubic Meter (vi) Min Secondary Chamber Volume - 0.25 Cubic Meter (vii) Min ESP Smoke holding Chamber Volume - 0.1 Cubic Meter (viii) Machine Weight - 400 to 500 Kgs (ix) No. of Absorption Chambers - 8 (x) Primary Chamber Temperature -800 to 900 Degree Centigrade with Auto Power Cutoff (xi)Secondary Chamber Temperature - 1000 to 1100 Degree Centigrade with Auto Power Cutoff (xii) Insulation - 1425 Degree Centigrade ceramic Boards (xiii) Min Primary Chamber Thickness -3mm (xiv) Min Secondary Chamber Thickness - 5 mm (xv) Min Outer Body Thickness - 1.2 mm
Item No. Contd 136.10 (xvi) Safety Measures - 3 MCB (xvii) Secondary Chamber Retention time - More than 2 seconds (xviii) Power Supply - 230v 16 Amps Single Phase (xix) Synchronized Primary and Secondary Temperature control (xx) Incineration Capacity - 50 kg per Hour (xxi) Smoke Treatment Technology - ESP with Corona effect (xxii) Combustion Efficiency - 99% (xxiii) Insulation Thickness - 115 MM (xxiv) Stand to be provided with two lockable wheels (xxv) All Weather Protection to be provided. (xxvi) Temperature Display to be provided. (xxvii) Timer Control to be provided. (xxviii) Temperature Control to be provided. (xxix) Primary Chamber Heater Watt - 5000 Watt (xxx) Secondary Chamber Heater Watt - 3000 Watt Make : Yatherm Scientific (Gautam Budha nagar : UP), Ajanta Export Industries, Aim Engineering & Consultancy Services or equivalent make as approved by Accepting Officer.
Supply, install, testing & commisioning of movable washing kit with following specifications : (i) Min dimensions (W X H X L) - 600 X 1000X 1200 in mm (ii) Weight - 60 Kg (iii) Body Structure - M.S. pipe and sheets, Powder coated (iv) Water tank make and capacity - Sintex/Finolex/ Plasto, 200 litres (v) Engine make - Honda/ equivalent (vi) Engine power and fuel type - 6.5 HP, Petrol Engine, 350 cc (vii) Fuel tank capacity - 3 litres (viii) HTP pump - Shakti / Taiwan /equivalent of 800-1200 RPM (ix) HTP pump pressure and lpm - 10 to 40 kg/cm2 & 30-40 lpm (x) Washing kit type - Movable anywhere (Trolley type) with 200 meter hose pipe
DG SET
Supply, installation , testing and commissioning of silent Diesel Engine driven generating set liquid cooled, factory assembled , 415 volts, 3 phase 4 wire, 50HZ, 0.8 p.f. engine as per IS:10001/ 10002 and Alternator as per IS: 13364 and conforming to New CPCB-IV+ norms for emmission complete with generator protection relay including CTs with all required protective relays and switch gears and electronic control and isolation emergency stop facility suitable for 160 KVA capacity silent DG set as per standard scope ,inbuilt AMF Panel , control panel having electronic meter and sound proof canopy as per CPCB-IV+ norms and PCC foundation (1:2:4 type B2) of approx depth 150 mm above finished genset room floor level, length & breadth of foundation should be atleast 250 mm more on all sides than size of enclosure and mounted on sturdy M.S. frabricated base frame ,fuel tank of 24 hr run capacity and fuel pipe set of two (inlet / outlet) mounted on common base platform,anti vibration mounting pads , safety switches for LLOP,HWT, etc. of capacity 160 KVA complete all as specified and directed by Engineer-in-charge. Note :The standard scope and specifications of DG set shall be as under :- Engine : Engine with direct injection,water cooled engine , 6 cylinder , in -line, 4 stroke, developing 199 HP at 1500 RPM, conforming the following is specifications :- Radiator with Fan, Electric starter motor with soft starting system,Electronic Governor (G3 as per ISO 8528 Part V class governor), Battery charging alternator,Dry type Air cleanerwith service indicator ,CRDI System,Lube Oil & Fuel filter,DOC, SCR,First fill of lube oil & coolant,IoT Remote Monitoring System
Item No.137.01 Contd... Alternator : (i) Brushless alernator (ii) Self - excited , self - regulated (iii) Class 'H' insullation (iv) Salient pole revolving field (v) Single bearing (vi) Automatic voltage regulator (vii) Acoustic enclosure, The Enclosure is of modular construction.Durable industrial locking system is provided on doors.The sheet metal components are pre-treated and are Polyester based powder coated (inside as well as outside) for long life. Specially designed sound attenuators are provided to control sound at air entry & exit points inside the enclosure.;- Engine alternator assembly mounted on AVM with Silencer and SS exhaust below suitably optimized to meet stringent sound emission standards as laid down by MOEF/ CPCB. (viii) Base rail with drawn-out type. (ix) Fuel tank is provided with drain plug,air vent,inlet and outlet connections, level indicator ,manhole etc. (x) Sub-base fuel tank with 13.5 hours capacity at75 %load. (xi) 12V dry battery 120 Ah with connecting leads and terminals. (xii) Control panel : Powder coated control panel manufactured with CRCA sheet provides:- (a) MCCB of sutaible rating with short circuit protection (b) Controler which displays voltage,current,KW,PF,Frequency,KWh. Indicating lamps for "Load On" and "Set Running" (c) Current Transformers of suitable ratings (d) Copper Cables of suitable capacity with incoming and outgoing terminations (e) Control fuses duly wired and ferruled
Item No.137.01 Contd... Power cables : Uninyvin copper conductor cable between Altemator & Control panel inside the canopy. Literature : (i) Operation Manual (ii) General maintenance & installation Guidelines (iii) Foundation Drawing (iv) Parts manual Note :- The rate to be quoted shall be including are all above standard scope and specification.
M & L for maintenance free chemical earthing with copper plating earthing electode inner pipe dia 42mm and outer pipe dia 76mm coating thickness of 250 mircrons over the rod and 3 mtr long duly inserted in ground by making a bore hole of 250 mm dia, 16 feet deep. Earthing enhcancing compound of 50 kg in sullery form shall be poured in hole after insertion of eletrode, remaining portion of hole shall be filled with excavated earth, interconnected with copper strip of size 20x3 mm and connected by means of exothermic brazing & protected by GI pipe light grade 32 mm bore and PCC (1:3:6) type C1 earth chamber & cast iron earth pit cover 300x300x3 mm connecting to test point & testing on ground complete including excavation, earth work, boring in any type of soil strata & cleaning of site complete all as specified and directed by Engineer-in Charge. Note :- (i) Cost of copper strip 20x3 mm and 32 mm dia GI pipe light grade required for interconnection of copper plate earth electrode 76 mm dia earth electrode is deemed to be included in unit quoted rates. The unit rate includes copper strip and protection pipe upto 7.5 metre. (ii) Cost of earth work, boring, PCC earth pit, CI cover, testing of earth after completion, connecting and commissioning is deemed to be included in unit quoted rates. (iii) Marking & painting of earth pit with iron plate of suitable size is deemed to be included in unit quoted rates.
Item No.138.00 Contd... (iv) The boring will take place for 3 meter depth & 100 mm dia for copper earth electrode pipe. Earth enhance compound to be filled around the earth electrode in 100 mm dia in 3 layers of 1 mtr each by means of PVC pipe of 100mm dia as casing/formwork. The remaining volume of bore shall be filled with clay soil (available from vicinity) in 3 layers of 1 mtr each. The PVC pipe to be removed sinultaneously. The cost of all this is deemed to be included in the quoted rate. (v) Minimum distance between each earthing is not less than 3 running meter. (vi) Testing of earthing shall be conducted and result should be less than 1.00 Ohms
S&F GI tubing 20 mm dia bore (ISI) marked) medium grade, with all fittings, laid in trenches or fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge.
All as per Item No. 139.00 here-in-before above but 25mm dia bore
All as per Item No. 139.00 here-in-before above but 50mm dia bore
S&F 20mm bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe with fittings and accessories, ISI marked and as per IS 14846 complete all as specified and directed by Engineer-in-Charge.
S&F 50mm bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe with fittings and accessories, ISI marked and as per IS 14846 complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth for foundation, etc, or for shafts, wells, cesspits, manholes pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick as in soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (soil) n. Exc. 50 mtr and depositibg where directed at a level n. Exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Cutting the existing pipe & inserting Tee size of 80x80x50mm complete all as specified and directed by Engineer-in-charge.
Construction of valve chamber of size 90 x 90 x 90 cm (internal dimensions) with the following specifications and complete all as specified and directed by Engineer-in-Charge :- (i) 15cm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation concrete. (ii) PCC solid block masonry 200mm thick using grade C-5 block built in CM 1:6. (iii) Rendering 15mm thick in CM 1:4 finished even and fair. (iv) PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in coping. (v) 3mm thick MS sheet cover alongwith MS angle iron frame 40 x 40x6 mm duly embedded in coping concrete with necessary locking arrangement. (vi) Painting MS sheet cover and frame with two coats of synthetic enamel paint over a coat of red oxide primer. NOTE : Excavation and earthwork shall deemed to inclusive in the rate quoted by the contractor.
Supply, Installation, testing and commissioing of outdoor type step down transformer 160 KVA, 11/0.433 KV, 3 Phase 50 Hz, ONAN Cooled Oil Immersed Copper wound complete with oil tank including first fill of ISI marked insulating oil up to top level, oil level indicater, breather with Silica gel, lifting hooks, drain valve, air vent valve, tackel wheel with channel and locking arrangement to put on the plinth with external cooling tubes, Core type, delta connected on primary side (HV) and star connected on secondary side LV) in accodance with vector symbol DYN-11 (vector Group-4) with neutral brought out on secondary side (LV Side) OFF load tap Changer with mannual voltage regulation 0.433 KV in suitable steps/position on HV side to give output of 0.433 KV on LV side and provision of following accessories and connecting with electrical system, earthing etc. including all jointing materials, all as per IS 1180-2014 and energy efficiency level-II including filling of trasformer oil having confirming to IS : 335-1993 of dyelectric strength more than 50KV and shall comprise of the following accessories as per manufactures direction and ambient temperature for design to be taken as 60 degree C :- (a) 03 Nos porclain HT bushings with brass/gun metal bushingrods complete with nut and washers on primary(HV) side with arcing horn. (b) 4 Nos porcelain bushings with brass/gun metal bushing rods complete with nut and washers on secondary(LV) side suitable for XLPE LT Cable. (c) Oil conservator with filter typedrain valve and oillevel gauge oil filter hole with caps/plugs and breather assemby. (d) De-hydrating breather with first fill dehydration agent (Silica gel). (e) Explosive vent.
Item No.149.00 Contd... (f) Thermometer pocket on tank cover. (g) One No 100MM dia, dial type thermameter, vapour pressure type having range 0-120 degree celsius with metal guard having minimum perimeter reading temperature indicator with resisting device for transformer. (h) Two earthing terminals to be provided diagonally on either side of transformer body to facilitate fixing of 50x6 mm galvanised iron earth strip for body earthing. (j) Name plate and terminal marking. (k) Oil drain filter valve. (l) Lifting lugs. (m) Oil filling hole with cap/plug with conservative tank. (n) Four plain solid cast steel detachable rockters. (o) Provision of 2 Nos danger boards 250/200 mm size made out of 1.6 mm thick plate, viterous enamele white, with letters figures of voltageand conventional skall and benes insignal red colours on frant side. The rear side of the plate also be enamelled. (p) Any other fittings/accessories so as to confirm the whole transformer to 1180 : 2014. (q) Off load changer of range (+) 7.5% to (-) 7.5% instep of 2.5% each, 7 steps.
Material and Labour for switch air break gang operated triple pole mechanically operated,mounted on HT insulator (12 insulator type vertical type) and MS galvanised steel frame withn operated mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps,bolts and nuts and washers etc also including drop out explusion type of fuse barrels of required capacity to suit load at site including two coats of red oxide primer on MS work complete all as specified and directed by Engineer-in-charge. Note :- Channel, cross arms, bracings etc shall be measured and paid separately
S&F lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11 KV transmission line complete all as specified and directed by Engineer-in-charge.
Supply & erect steel tubular pole swagged type as per IS 2713 complete with MS base plate finial tapper plug cap bolt, nut, screws etc all as specified for swaged pole of type 410 SP 55 , 11 mtrs long including painting with two coats of aluminium paint over a coat of red oxide paint including removing existing pole complete all as specified and directed by Engineer-in-charge. Note : Excavation and earth work and PCC in foundation shall be measured and paid separately
M&L for cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section (MS channel, angle sections, flat, round or square bars ) for reqd sizes and shape including bolts nuts & washers welding bending cutting cold or hot drilling holes for inserting in any shape or size as indicated and including applying two coats of aluminium paint over a coat on oxide primer complete all as specified and directed by Engineer-in-charge.
Supply, laying & testing HT electric cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade of size 3 core 95 sq mm complete all as specified and directed by Engineer-in-charge.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed by Engineer-in-charge.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured luminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed by Engineer-in-charge.
Supply, Install, Testing & Commissioning self supporting outdoor type totally enclosed LT Panel board of suitable size, IP-65, compartmentalised design, dust and varmin proof of suitable size suitable for 440 Volt 3 phase 4 wire system made out of 3.15 mm thick CRCA sheet and built upon rigid frame work having front and rear hinged doors with neoprence rubber gasket including danger plate, earthing strip point and, ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size of Zinc/Cromium plated and nuts, bolts ;and washers etc. The pannel shall be painted with two coats of red oxide primer and final finish of synthetic enmelled gray paint and incomming/outgoing cable holes at the bottom. The Panel shall be emmbeded with 50 x 5 mm MS Angle Iron frame and 30 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 complete complete all as specified and directed by Engineer-in-charge. (Location : NearTransformer) Note : All Internal connection of MCCB from BUS Bar made By using Aluminium busbar of rated Capacity :- (a) Aluminium bas bar 600 amps - 04 Nos, supported with suitable size of heavy duty PVC stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 4 Pole, 320 amps, 415 volt, adjustable type 35 KA Breaking capacity -01 No (In coming)
Item No.157.00 Contd... OUTGOING (c) MCCB 4 Pole 100 amps, 415 volt, adjustable type, 25 KA Breaking capacity -03 No (02 Nos Bus bar Panel & 01 Spare) (d) MCCB 4 Pole 63 amps , 415 volt, adjustable type 16 KA Breaking capacity -03 No (02 Nos Bus bar Panel & 01 for street light) (d) MCB TPN 63 amps , 415 volt, 02 Nos (01 for Shed No E & 01 for Guard Room) (e) Time Switches Astro type (having longitude and latitude of indian cities in memory) 250 V , Power contactor 3 pole AC, with 230V coil, 9 amps rating,MNX Make : L&T Contactor fitted inside steel enclosure-01No (f) Digital VAF Meter (g) LED Indicating lamp (set of three) - 01 Set. (h) Internal control wiring with 1100 volt grade 1.5 Sq.mm stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT 25x20cm size complete all as specified and directed by Engineer-in-Charge.
M&L for maintenance free chemical earthing with copper plating earthing electode inner pipe dia 42mm and outer pipe dia 76mm coating thickness of 250 mircrons over the rod and 3 mtr long duly inserted in ground by making a bore hole of 250 mm dia, 16 feet deep. Earthing enhcancing compound of 50 kg in sullery form shall be poured in hole after insertion of eletrode, remaining portion of hole shall be filled with excavated earth, interconnected with copper strip of size 20x3 mm and connected by means of exothermic brazing & protected by GI pipe light grade 32 mm bore and PCC (1:3:6) type C1 earth chamber & cast iron earth pit cover 300x300x3 mm connecting to test point & testing on ground complete including excavation, earth work, boring in any type of soil strata & cleaning of site complete all as specified and directed by Engineer-in-Charge. Note :- (i) Cost of copper strip 20x3 mm and 32 mm dia GI pipe light grade required for interconnection of copper plate earth electrode 76 mm dia earth electrode is deemed to be included in unit quoted rates. The unit rate includes copper strip and protection pipe upto 7.5 metre. (ii) Cost of earth work, boring, PCC earth pit, CI cover, testing of earth after completion, connecting and commissioning is deemed to be included in unit quoted rates.
Item No.159.00 Contd... (iii) Marking & painting of earth pit with iron plate of suitable size is deemed to be included in unit quoted rates. (iv) The boring will take place for 3 meter depth & 100 mm dia for copper earth electrode pipe. Earth enhance compound to be filled around the earth electrode in 100 mm dia in 3 layers of 1 mtr each by means of PVC pipe of 100mm dia as casing/formwork. The remaining volume of bore shall be filled with clay soil (available from vicinity) in 3 layers of 1 mtr each. The PVC pipe to be removed sinultaneously. The cost of all this is deemed to be included in the quoted rate. (v) Minimum distance between each earthing is not less than 3 running meter. (vi) Testing of earthing shall be conducted and result should be less than 1.00 Ohms
M&L for earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron wire 4.0 sqmm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 20mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed by Engineer-in-charge.
Supply, lay, test and commissioning of LT electric cable, XLPE insulated, heavy duty, 1100V grade of size 120 Sqmm 3½ core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required complete all as specified and directed by Engineer-in-charge. Note : Earthwork excavation sand cushioning GI protection pipe etc shall be measured and paid separately in their respective items
All as per Item No. 161.00 here-inbefore above but size 3½ core 95 sq mm.
All as per Item No. 161.00 here-inbefore above but size 3½ core 70 sq mm.
All as per Item No. 161.00 here-inbefore above but size 3½ core 50 sq mm.
All as per Item No. 161.00 here-inbefore above but size 4 core 16 sq mm.
All as per Item No. 161.00 here-inbefore above but size 2 core 16 sq mm.
Supply & erect in repair in position steel tubular pole swagged type as per IS 2713 complete with MS base plate finial tapper plug cap bolt, nut, screws etc all as specified for swaged pole of type 410 SP 31 , 09 mtrs long including applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge. Note :- Excavation and earth work and PCC in foundation shall be measured and paid separately
S&F weather proof Street light Junction Box of size 240 x 130X95 mm depth including MCB SP 10 Amp C Curve and connecting terminals 4-way and fixing with street light poles (steel) using necessary MS Clamps, nuts, bolts washers of suitable size etc. including fixing arrangement complete all as specified and directed by Engineer-in-charge.
S&F street light bracket made out of 40mm dia light grade GI pipe 1.5 Mtr long bend to shape including necessary fixing arrangement with MS Clamp of suitable size made out of 35 x 4 mm MS flat suitable shape to pole including nut bolts 03 Nos and washers complete all as specified and directed by Engineer-in-charge.
S&F LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver with separate surge protection device 5ka rating , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and sepatate connector block for termination of incomming cable connection complete all as specified and directed by Engineer-in-charge.
Supply and fixing 3 core PVC insulated and unsheathed 1100 volt grade multicore cable 1.5 sqmm with stranded copper conductor cable drawn inside the pole whereas required with making necessary holes on bottom and top of pole from looping box to security light fitting complete all as specified and directed by Engineer-in-charge.
S&F ACSR conductor and strengthening on insulators including aluminium binding wire including reconnecting service connections any type which has been disconnected while dismantling old conductor including dismantling of U/S conductor any type any size complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:4:8, type D-2 (using 40 mm aggregate) as in foundation for pole/four pole structure etc.complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:3:6, type C-1 (using 20 mm aggregate) as in coping/stay of pole etc. including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for plain cement concrete 1:2:4 type B1 using 20mm graded aggregate as footing for poles etc including necessary formwork complete all as specified and directed by Engineer-in-charge.
S&F GI pipe light grade of dia 80 mm laying in road and along with poles for cable protection complete all as specified and directed by Engineer-in-charge.
S&F GI pipe light grade of dia 50 mm laying in road and along with poles for cable protection complete all as specified and directed by Engineer-in-charge.
S&F GI pipe light grade of dia 40 mm laying in road and along with poles for cable protection complete all as specified and directed by Engineer-in-charge.
Construction of Plinth of size 2.5 m x 2.5 m x 1.6 m for transformer, using 100 mm thick PCC 1:4:8 type D-2 as in lean concrete, flyash brick masonry in CM 1:6, the top of the plinth shall consist of 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) over 75 mm thick PCC 1:4:8 type D-2 over compacted moorum filling, 10 mm thick rendering in CM 1:4 on brick surface with and including 25 cm thick stone aggregates of size 12.5 mm all around upto and including 1.5 m from the edge of the plinth complete all as specified and directed by Engineer-in-charge.
Supply and laying DOUBLE WALL CORRUGATED (DWC) pipe 110 mm outer dia 96 mm bore as per IS-16205 part-24 cable protection including all fitting as required complete all as specified and directed by Engineer-in-charge.
Supply and laying DOUBLE WALLED CORRUGATED (DWC) pipe 90 mm outer dia 76 mm bore as per IS-14930 part-2/IS-16205 part-24 cable protection including all fitting as required complete all as specified and directed by Engineer-in-charge.
Supply and laying DOUBLE WALL CORRUGATED (DWC) pipe 75 mm outer dia 63 mm bore as per IS-16205 part-24 cable protection including all fitting as required complete all as specified and directed by Engineer-in-charge.
Supply and laying DOUBLE WALL CORRUGATED (DWC) pipe 50 mm outer dia 38 mm bore as per IS-16205 part-24 cable protection including all fitting as required complet all as specified and directed by Engineer-in-Charge.
Excavating in trenches, not exc. 1.5m wide and not exc. 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in hard rock complete all as specified and directed by Engineer-in-charge.
Excavation in trenches for errection of poles etc.,n. exc 1.5m wide, exc 1.5m and n. exc 3.0m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in hard rock complete all as specified and directed by Engineer-in-charge.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of hard rock complete all as specified and directed by Engineer-in-charge.
S&F feeder pillar made out of 3.15mm CRCA sheet, power coated minimum 80 Micron, weather proof, size not lett than 800 (w)x700(H)x500(D) mm 3 Ph out door single door, with FRP inculstor 1100V , Aluminium Busbar 100 Amps current density not less than 2.0 shall be mounted on MS angle stand 40x40x5mm height 400mm above ground level and 200mm under PCC structure, earthing bolt to be provided M-10 complete including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
Pioneer Enterprises (BID ID -3456337)
M/s godara infratech and power industries (BID ID -3457825)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.54 MB
TENDER_84345.pdf
Tender Documents • 3.92 MB
DRAWING1TO7.pdf
Additional Documents • 4.51 MB
BOQ_815188.xls
BOQ • 0.45 MB
54AOC.pdf
Tender Documents • 0.51 MB
BOQ_AMEND_06102025.pdf
PDF • 0.57 MB
DATE_CORRIGENDUM_06102025.pdf
PDF • 0.38 MB
DATE_CORRIGENDUM_13092025.pdf
PDF • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .