| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC | ₹2.6 Cr | L1 | Accepted-AOC L-1 |
| 2 | L2₹2.6 CrRejected-Finance | ₹2.6 Cr | L2 | Rejected-Finance L-2 |
| 3 | Rejected-Technical 202 SHRILOK COMPLEX H B ROAD THARPAKHNA RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | - | - | Rejected-Technical Non Responsive |
| 4 | Rejected-Technical | - | - | Rejected-Technical Non Responsivea |
| Sl No | Description | Qty | Unit | M/s RAVI INFRASTRUCTURE L1 | Star Express Consultants Pvt. Ltd L2 |
|---|---|---|---|---|---|
| 1.00 | Earthwork in excavation Trenches in hard soil (vide classification of soil item -B) all complete as per approved design, building specification and direction of E/I | 1,144.84 | CUM | 150.95 ₹1,72,812.99 | 154.86 ₹1,77,289.3 |
| 2.00 | Extra for earth work in hard soil as per
specification and direction of E/I. (vide classfication of soil item - B) | 615.81 | CUM | 15.5 ₹9,545.04 | 15.82 ₹9,742.1 |
| 3.00 | Filling in foundation trenches and plenth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dresssd with earth obdiened from excavation of foundation trenches within a lead of 50 m and lift of 1.5 M all complete as per building specification and direction of E.I (Mode of measurement compacted volume.) | 285.08 | CUM | 55 ₹15,679.68 | 56.39 ₹16,075.94 |
| 4.00 | Providing coarse clean SAND FILLING in foundation trenches or plinth including ramming & watering in layers not exceeding | 180.57 | CUM | 587 ₹1,05,992.83 | 601.3 ₹1,08,574.94 |
| 5.00 | Providing designation 75 Abrick work in C.M (1:6)in foundation and plinth with approved quality of clean coarse sand of F.M2 to 2.5 including providing 10mm thick morter joints , cost of screening materials , raking of joints to 15mm depth , curing taxes and royality all complete as per building specification and direction of E/l | 114.52 | CUM | 5,098 ₹5,83,828.06 | 5,212.47 ₹5,96,937.28 |
| 6.00 | Providing 125mm thick reinforced designation 75A brickwork in C.M. (1:4) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as sper building specification and direction of E/I. | 7.17 | SQM | 710 ₹5,090.7 | 727.76 ₹5,218.04 |
| 7.00 | Providing P.C.C. M - 150 with nominal mix of (1:3:6) in foundation with approved quality of stone chips 20 mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l. | 2.35 | CUM | 4,114 ₹9,676.13 | 4,207.92 ₹9,897.03 |
| 8.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) | 170.83 | CUM | 3,741.9 ₹6,39,221.29 | 3,826.67 ₹6,53,702.38 |
| 9.00 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | 67.02 | SQM | 350.85 ₹23,513.62 | 358.79 ₹24,045.75 |
| 10.00 | Providing R.C.C. M-200 in band at plinth level with nominal mix of (1:1.5:3) of approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I. | 113.91 | CUM | 5,204.95 ₹5,92,890.65 | 5,322.36 ₹6,06,264.71 |
Tender Value
₹2.6 Cr
EMD Value
₹2.6 L
Closing Date
13 Nov 2025, 1:00 pmClosed
Office of the E.E, BCD Special Works Div., Ranchi
Office of the E.E, BCD Special Works Div., Ranchi
Proposed Renovation work of Secretariate Building- Civil work at Hindpiri, Ranchi.
2025_BCD_106201_1
BCD/EE, Special Works Div, BCD, Ranchi-31/2025-26
Open Tender
Civil Works - Buildings
Ranchi
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹2.6 L
21 Jan 2026
31 Oct 2025
14 Nov 2025
31 Oct 2025
13 Nov 2025
31 Oct 2025
Amount
Earthwork in excavation Trenches in hard soil (vide classification of soil item -B) all complete as per approved design, building specification and direction of E/I
Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B)
Filling in foundation trenches and plenth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dresssd with earth obdiened from excavation of foundation trenches within a lead of 50 m and lift of 1.5 M all complete as per building specification and direction of E.I (Mode of measurement compacted volume.)
Providing coarse clean SAND FILLING in foundation trenches or plinth including ramming & watering in layers not exceeding
Providing designation 75 Abrick work in C.M (1:6)in foundation and plinth with approved quality of clean coarse sand of F.M2 to 2.5 including providing 10mm thick morter joints , cost of screening materials , raking of joints to 15mm depth , curing taxes and royality all complete as per building specification and direction of E/l
Providing 125mm thick reinforced designation 75A brickwork in C.M. (1:4) in Superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as sper building specification and direction of E/I.
Providing P.C.C. M - 150 with nominal mix of (1:3:6) in foundation with approved quality of stone chips 20 mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing R.C.C. M-200 in band at plinth level with nominal mix of (1:1.5:3) of approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Providing French spirit polishing over new wooden surface to give desired texture and gloss with approved make and shade of ready mixed French polish including preparing the surface after cleaning removing dirt,scales grease including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Supplying fitting and fixing 35mm thick solid core type non-decorative single leaf flush shutters In doors and window with black board core blended with high quality phenol format dehyde
Providing T or steel reinforcement of 8,10 mm, 12 mm, &16 mm dia barsas per approved design and drawing excluding carriage of bars to work site, cutting, bending and binding with annealed wie with cost of wire, removel of rust, placing the rods in position all complete as per building specification and direction of E.
providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)
providing Tor steel reinforcement of 10 mm dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.
providing Tor steel reinforcement of 12mm dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.
Supplying, fitting & fixing M.S. GRILL made of 20 x 6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I.
Providing designation 75B one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I.
Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete
Providing and laying 25mm thick white makrana marble tiles in risers of steps, skirting and pillers of approved quality over 12mm thick base of cement mortar (1:3) and jointed with white cement slurry including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I.
Providing 12mm thick cement plaster (1:3) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I.
Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/l.
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface
Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with. brush, roller or spray for water proofing coating as per manufacturer specifications with following steps: (a)surface preparation :-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint /coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt.Ltd. / MYK Schomberg Dr Fixit/Fosroc or equivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mm X 150 mm fillet of mortar (Cement: sand -
1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. (b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." ( c) 2nd Coat :-To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours
to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:-Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance Chemical Base Part A: Acrylic copolymer, Part B: Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +27°C Tensile Strength -2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength ~2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength ~4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370) (d) Protection of treated surface with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of of cement to be added in the screed concrete (paid separately for this items).
All corners shall be chamfered with 150mm X-150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika India Pvt.Ltd./MYK Schomberg / Dr Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured." (e) Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately). Brand Sika India Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc. Warranty for five years.
Covering of treated surface wrth PCC :- Providing 25 mm thick Cement Concrete M20 (1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and cleaned sand of F M 2.5 io 3 including screening,shuttering, and mixing cement concrete in mixer with admixture of integral water proofing and placing in position, striking curing,taxes and royality all complete as per building specification and direction of E/l. Panels that has been left should be casted next day.- There should be 6 mm gap between Panels. Brand- Sika_Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421 ic , Dr Fixit Pidiproof LW+
Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats,
weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
Ventilator Casement window single panel with or without fixed panel with S.S. 304 friction hinges as per size and weight of sash, single point locking zinc alloy (zamak) powder coated handlesUsing R2 series with frame (39mm & above ) x (39mm & above) & sash /mullion (39mm & above) x (60mm & above). (Height upto 1.2 metre)
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm Rain water pipe
Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Providing and laying in situ five course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0 mm thick of 3.00 Kg/ sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 5th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by tablevibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Internal work -Exposed -ON - Wall Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge.
25 mm nominal outer dia pipes
32 mm nominal outer dia pipes
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness
Providing and fixing aluminium TUBULAR HANDLE BAR 32 MM OUTER dia 3.0 mm thick & 2100 mm long with SS screws etc complere as per direction of E/I
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I
Chips
Brick
Supplying and fixing male ended 15 mm dia brass bib cock of approved quality (wt. not less than 350 grms) with extra socket all complete as per specification and direction of E/I.
Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I.
Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I.
(c) 25mm dia
32 mm and weight not less than 700 gms.
supply materials labour for constraction of 600x600x90mm stop cock chamber of brick masonary.
Copper earth plate electrode:- Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonary enclours with cover plate having locking arrangrment and watering pipe etc .as requried .(But with out charcoal or coke and salt).
S/L 8 SWG copper wire in ground:- Suppling and laying 8SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldring as requried.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
MV Cable Laying up to 25 sq. mm. in ground :- Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm. direct in ground including excavation, sand cushioning, protective covering by 2nd class bricks and refilling the trench etc as required.
MV Cable Laying up to 400 sq. mm. in ground :- Laying of one number PVC insulated and PVC Sheathed / XLPE power cable of 1.1 KV grade of size exceeding120 sq.mm. but not exceeding 400 sq.mm. direct in ground including excavation, sand cushioning, protective covering by 2nd class bricks and refilling the trench etc as required.
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, (SINTEX / SINTER) ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
Supply fitting and fixing GI pipe 50 mm Dia (TATA or equivalent make) Medium Quaility as per IS:1239 ( part 01 ) 2004
Heavy duty,armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. 3.5c x 185 mm2 1.1kV
4c x 10 mm2 1.1kV
2c x 10 mm2 1.1kV
Providing , laying and fixing following dia GI pipe (medium Class) in ground complete with G.I.Fittings including trenching (75 cm deep) and refilling etc. as required.
40 mm dia
65 mm dia
Providing and supplying High Density Polyethyene pipe (HDPE pipe) of 20 mm to 225 mm OD and pressure 6.0 Kg/cm2 and 10 Kg/cm2 sutable ford water supply which is available in all standard, like ISI-4984, ISO - 4427 DIN-8074 and various grades like PE-63, PE-80, PE-100 and newly invented PE 100+ materials rates are exfactory excluding transpotation, taxes and duties, contractor profit and overhead charges. Note : CST @2% against Form 'C' and 4% without Form C' would be charged extra.
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to125.00 M
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I.
3 core PVC insulated PVC sheathed copper conductor flat submersible cable. Supplying , Flat flexible submersible cable with ,copper conductor , PVC insulated and PVC sheathed as IS:7098 3 Core 4 Sq mm
NON- SCHEDULE ITEM Sohrai Painting
Plastic Hose Pipe 1/2" dia
Sprinkler: Ketsy 771 Gardening Water Sprinkler Brass 3/4 size (Trajectory Angle 27 Degree)
Add 18 % GST
Add 1% Labour Cess
Star Express Consultants Pvt. Ltd (BID ID -686966)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
SBD-31.pdf
Tender Documents • 4.09 MB
Corrigendum.pdf
Additional Documents • 0.15 MB
BOQ_143031.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid