| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC 213 BAHARTI NAGAR SUBASH NAGAR JAMMU JAMMU JAMMU JAMMU KASHMIR 180007 | JAMMU | JAMMU AND KASHMIR | 180007 | L1 | Accepted-AOC Awarded to L1 bidder | |
| 2 | L2₹5.5 L+₹43,185 (8.47%)Rejected-AOC | L2 | Rejected-AOC Not eligible due to L2 bidder awarded to L1 bidder. |
Tender Value
₹6.3 L
EMD Value
₹12,529
Closing Date
27 Jun 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER
FTR HQ BSF JAMMU
AS PER NIT
2022_BSF_695824_1
08/EE(E)/FTR-JMU/2022-23
Open Tender
Electrical Works
Works
90 days
PALOURA CAMPUS, FTR HQ BSF JAMMU, J AND K KASHMIR
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹12,529
6 Aug 2022
20 Jun 2022
28 Jun 2022
20 Jun 2022
27 Jun 2022
20 Jun 2022
90 days
Amount
Dismantling of old light fittings, ceiling fans, switch & socket, conduits,switch boards, wires etc as required
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for light point/ power plug with 2x 4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, along with 1 No 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required .
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as rerquired. i) 2 x 1.5 sqmm + 1 x 1.5 sqmm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing 3 pin 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing PVC angle holder including connection etc as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing, Installation, testing and commissioning of 1200 mm ceiling fan of Usha swift DLx, Havells, Bajaj/Orient/Crompton Whirl wind HE or with equivalent specification, also necessary ceiling fan hook including wiring the down rod of standrad length ( upto 30 cm) with 1.5 sqmm FRLS PVC insulated, copper conductor, single core cable in cluding providing and fixing phenolic laminated sheet cover on the fan box etc as required.
Supplying and Fixing of 20 W LED battern of following specifications: Input voltage-220-240 V,50 Hz, Input wattage: 20 Watt, Efficacy:100 Lm/Watt, cool daylight 6500 K with extruded polycarbonate diffuser directly in-wall/ceiling with connections, etc as required. Havells/ Philips/ Crompton Make (Compatible with Havells Model-LHEXAWP7IN1W020LED) or with similar specifications.
Providing and Laying of one number aluminum conductor PVC insulated and PVC sheathed / XLPE armoured power cable of 1.1 KV grade of following size direct in the ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. a) 2 x 25 sq. mm
Providing and laying one number 2 X25 sq. mm PVC insulated and PVC sheathed XLPE armoured power cable of 1.1 KV grade in the existing RCC/HUME/Metal pipe as required.
Providing and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of 2X25 size in the existing masonry open duct/ in air as required
Providing, laying and fixing of 32 mm dia. G.I. pipe (medium class) in wall/floor for protection of UG cable including cutting the wall / floor and making good the same as required.
Ms Engineers and Contractors
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .