| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC | ₹1.0 Cr | L1 | Accepted-AOC LOWEST BIDDER LETTER OF ACCEPTANCE GIVEN |
| 2 | L2₹1.0 CrRejected-AOC NEOGIPARA AMTA HOWRAH WB 711401 | AMTA | HOWRAH | WEST BENGAL | 711401 | ₹1.0 Cr | L2 | Rejected-AOC HIGHER THAN LOWEST BIDDER |
| 3 | L3₹1.1 CrRejected-AOC PURBA BARDHAMAN | HOOGHLY | WEST BENGAL | 712134 | ₹1.1 Cr | L3 | Rejected-AOC HIGHER THAN LOWEST BIDDER |
| 4 | Rejected-Technical | - | - | Rejected-Technical Credential not matching as per NIT |
Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
29 Dec 2025, 6:00 pmClosed
Principal, Sivanath Sastri College
23/49, Gariahat Rd, Dhakuria, Kankulia, Kolkata, West Bengal 700029
Construction of Boundary wall and gates for the Second / Extended Campus (Educational Building) of Sivanath Sastri college at Sonarpur, South 24 Parganas, West Bengal
2025_DHE_946271_1
SNSC/NC/e-NIT-01/25-26 Dated- 12-11-2025
Open Tender
CIVIL WORKS
120 days
Sivanath Sastri College
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
₹2.1 L
Yes
Sivanath Sastri College at Conference Room
28 Feb 2026
18 Nov 2025
6 Jan 2026
18 Nov 2025
29 Dec 2025
29 Nov 2025
28 Nov 2025
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation not exceeding 1,500 mm.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
Controlled Cement Concrete grade M25 with well grade stone chips (20mm grade) excluding shuttering and reinforcement, with complete design of concrete as per IS:-456 and relevant special publications submission; of job mix formula after preliminary mix design after testing of concrete cubes as per direction of E.I.C. Consumption of cement will not be less than 6 bags/300kgs of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test & job-mix formula. i) Pakur Variety. At Foundation
Controlled Cement Concrete grade M25 with well grade stone chips (20mm grade) excluding shuttering and reinforcement, with complete design of concrete as per IS:-456 and relevant special publications submission; of job mix formula after preliminary mix design after testing of concrete cubes as per direction of E.I.C. Consumption of cement will not be less than 6 bags/300kgs of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test & job-mix formula. i) Pakur Variety. AT LVL 0.00 TO LVL +3.5 M
Controlled Cement Concrete grade M25 with well grade stone chips (20mm grade) excluding shuttering and reinforcement, with complete design of concrete as per IS:-456 and relevant special publications submission; of job mix formula after preliminary mix design after testing of concrete cubes as per direction of E.I.C. Consumption of cement will not be less than 6 bags/300kgs of cement per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test & job-mix formula. i) Pakur Variety. AT LVL 3.5M TO LVL +5.5 M
Hire & labour charges for shuttering with centering & necessay staging upto 4m. Approved stout props & thick hard wood planks of approved thickness with regarding bracing of concrete slabs, beams, columns, lintel curved or straight including fitting, fixing & striking out after completion of works. (Foundation & upto P.L.) 25 mm to 30 mm shuttering without staging in foundation
Hire & labour charges for shuttering with centering & necessay staging upto 4m. Approved stout props & thick hard wood planks of approved thickness with regarding bracing of concrete slabs, beams, columns, lintel curved or straight including fitting, fixing & striking out after completion of works. (Foundation & upto P.L.) Steel shuttering or 9mm to 12 mm thick approved ply board shuttering in any concrete. In ground floor
Hire & labour charges for shuttering with centering & necessay staging upto 4m. Approved stout props & thick hard wood planks of approved thickness with regarding bracing of concrete slabs, beams, columns, lintel curved or straight including fitting, fixing & striking out after completion of works. (Foundation & upto P.L.) Steel shuttering or 9mm to 12 mm thick approved ply board shuttering in any concrete. AT LVL 3.5M TO LVL +5.5 M
Labour for Chipping of concrete surface before taking up Plastering work.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply for rods, initial straightening & removal of loose rust (if necessary), cutting to requisite length hooking & bending to correct shape placing in proper position & with 16 gauge black annealed wire at every inter- section, complete as per drawing & direction. a) For works in foundation, basement & upto roof of ground floor/ upto P.L. Tor steel or Mild steel AT FOUNDATION
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply for rods, initial straightening & removal of loose rust (if necessary), cutting to requisite length hooking & bending to correct shape placing in proper position & with 16 gauge black annealed wire at every inter- section, complete as per drawing & direction. a) For works in foundation, basement & upto roof of ground floor/ upto P.L. Tor steel or Mild steel AT LVL 0.00 TO LVL +3.5 M
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply for rods, initial straightening & removal of loose rust (if necessary), cutting to requisite length hooking & bending to correct shape placing in proper position & with 16 gauge black annealed wire at every inter- section, complete as per drawing & direction. a) For works in foundation, basement & upto roof of ground floor/ upto P.L. Tor steel or Mild steel AT LVL 3.5M TO LVL +5.5 M
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation.
Brick work with 1st class bricks in cement mortar (1:6) In superstructure, ground floor
Brick work with 1st class bricks in cement mortar (1:6) Roof & Above
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 20mm thick plaster (1:6 cement sand morter) external plaster In ground floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 20mm thick plaster (1:6 cement sand morter) external plaster Roof & Above
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 15 mm thick plaster (1:6 cement sand morter) Internal plaster
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 10 mm thick plaster (1:4 cement sand morter) ceiling plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE: Cement 0.152 cu.m per100 sq.m.
Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades.
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coats-- Ground Floor
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coats-- Roof & Above
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Two Coats-- Super Protective 100% Acrylic Emulsion. Ground Floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Two Coats-- Super Protective 100% Acrylic Emulsion. Roof & Above
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) Two Coats Solvent based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) Luxury Quality
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On timber or plastered surface : With other than hi-gloss of approved quality- Two coats (with any shade except white)
Copal varnish of approved quality including preparing surface : On new wood work : Two coats
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive(6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e
) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. Deep Colour & White
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Local.
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. 50mm. X 40mm. X 2.5mm.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 100mm long x 10mm dia. bolt.
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: With continuous plate base (Hexagonal/ Round rod) 75 mm grip x 10 mm dia rod.
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white For 2-Track window : Members for Bottom frame @ 0.875 Kg per Mtr.and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kgper Mtr. and Interlock member @ 0.612 Kg per Mtr.For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr.and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. [Note : for estimate purpose construction wing may consider weight of 2-track Aluminium window @ 5.5 Kg per Sq.M.and 3-track Aluminium window @ 6.5 Kg per Sq.M]
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; B) coloured, toughened glass conforming to IS: 2553-1992 (part-II) 6mm thick
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : On steel or other metal surface : Two coats (with any shade except white)
Removal of mud/sludge/slurry/liquid earth obtained during piling work from the working site and disposal of the same beyond the KMC/Municipal or any suitable area with conformity of Municipal Corporation Rules using tanker including loading and unloading the same with pump, clearing the site complete in all respect as per direction of the Engineer-in-charge. For 450mm Pile
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. In ground floor including roof.
ADD 18% GST
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.03 MB
BOQ_2250498.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid