Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance E 366 2ND FLOOR NIRMAN VIHAR VIKAS MARG VIKAS MARG VIKAS MARG NEW DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Admitted-Finance |
| 2 | Admitted-Finance 15 1 GROUND FLOOR 4TH C MAIN ROAD OPP AGRO CORN PRODUCTS NEAR GOVT HEBBAL PRE UNIVERSITY HEBBAL BANGALORE KARNATAKA 560024 | BENGALURU URBAN | KARNATAKA | 560024 | Admitted-Finance |
| 3 | Rejected-Technical BHARATHIDASAN UNIVERSITY CAMPUS TIRUCHIRAPALLI TAMIL NADU 620023 | TIRUCHIRAPPALLI | TAMIL NADU | 620023 | Rejected-Technical Not meeting the NIT eligibility criteria of similar works and solvency certificate. |
| 4 | Not Admitted-Fee/PreQual/Technical CMS ATS GSO KALPAKKAM 603 102 CHENGALPATTU DISTRICT TAMIL NADU | CHENGALPATTU | TAMIL NADU | 603102 | Not Admitted-Fee/PreQual/Technical Others-Bid Security Declaration received after the due time for receipt of tenders. Hence, Tender is not considered |
Tender Value
₹97.0 L
Closing Date
17 Nov 2021, 4:00 pmClosed
GM, INRPK
Office of GM, INRPK, 608-A, Building, BARCF.
Design, Supply, Installation and Furnishing of Interior Decoration in Halls of NRB/BARCF, Kalpakkam
2021_BARC_655269_1
BARCF/KNRPC/PP/TR/17/2021
Open Tender
Architecture/Interior Design
Item Rate
120 days
Kalpakkam
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
26 Nov 2021
1 Nov 2021
18 Nov 2021
2 Nov 2021
17 Nov 2021
3 Nov 2021
3 Nov 2021 - 15 Nov 2021
Amount
Design,Providing and Fixing 15 mm thick Insula mineral fibre ceiling tiles Square edged eco friendly false ceiling tiles of approved texture Speckle/fissure Fine/ Textura of size 595 x 595 mm in true horizontal level. Mineral Fibre ceiling tile shall have NRC value of 0.65(Minimum), light reflection 90%, non - combustible as per B.S. 476 part 6 &7, 99% humidity resistance and also having thermal conductivity<0.055 K cal/hr. Ceiling tiles should be suspended on inter locking metal grid of hot dipped galvanized steel sections consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x32 mm x 3000mm made from 0.30 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross ""T"" of size 24x27 mm made out of 0.30 mm (Minimum) sheet, 1200 mm long spaced between main 'T' at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24 x27 mm made of 0.30 mm thick (Minimum) sheet to be inter locked at middle of the 1200 x 600 mm panel to form grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(22x20X3000 mm) made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick Insula mineral fibre ceiling tiles of approved texture Speckle/ Fissura Fine/ Textura in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main 'T' runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanized steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main 'T' , bottom exposed with 24 mm of all T-sections shall be pre-painted with powder coated paint, for all heights, as per specifications, drawings and as directed by engineer-in-charge. Only Insula mineral fibre false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm
Design,Providing and Fixing 'BARTONE WOODYWOOL' Panel having size 600x1200 mm and thickness of 15mm are made with inorganic binder wood fibre, which provide NRC 0.85 tested as per IS:8225-1987 (Equivalent to ISO: 354-1985 & ASTM 423 90). BARTONE’s Panels are an ecological green material. It is non-flammable as per IS:3614 (Part-II). It facilitates fast, rapid construction of walls. It is economic & energy efficient. Boards enhance the value of buildings. It requires very low maintenance cost. The product is ECO- Friendly and, tested as per Fire Retardant ASTMD 635-1991 and IS:15061-2002 for excellent results. System to be installed on wall fabric system by using FR Grade fabric of size 1400mm width, shall be stretched by using CC 25 with infill of synth wool 10X25 mm thick, rigid vinyl Stretch Tracks half wrap/full wrap 15mm and Mid-seam 15mm (FS15), wood wool board, synth infill with requisite accessories & tools. CC 25 mm is first installed on the wall along with the marking lines with metal fasteners inserted at 300mm centres. Gripper tracks to be installed on wooden base using tacks 150mm centres on one/both sides of Stretch Tracks. Wood wool board square edge pinewood panels of size 600x1200x15mm having density 400kg/m3, weight 4kg which is fixed to wall with suitable fasteners. Open Cell Sponge foam of 10mm thick adhered on strand panel by using adhesive. Fabric of width 1400mm is then aligned to the Stretch tracks by following the fabric thread line or pattern. The fabric is stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Note -minimum 50mm additional fabric is required for tucking hence maximum module wall fabric width would be 1300mm.
Design, Providing and applying of 2mm thick Epoxy flooring by prepare the surface by eitching, grinding, wire brushing to remove all dust, lase particles, dry slurry of any etc and apply two part epoxy component epoxy primer of approved make and allow it became tack free followed by providing and laying high build three part component epoxy floor topping system Fosroc’s Niotoflor SL2000 or equivalent in 2mm thickness including all materials, labour, leading, laying etc complete as per std.
Design,Providing and Fixing of 4mm thick HEGO Stone Plastic Composite Interlock Vinyl Flooring Planks of size 180mm x 12020mm by using PE underlay foam as per standards and as directed by the Engineer-in-Charge. Supply & Installation of MDF Profiles like Reducer, Skirting, T-Profile as per standards. 1. Sample shall be got approved before commencing the work.2. The above work shall be got executed from approved manufacturer only.
Design,Providing and Fixing false ceiling with 1.5mm thick tapered edge gypsem moisture resistant board at all height including providing and fixing frame work made of special sections, power pressed from M.S. Sheets and galvenized with zinc coating of 120gms/sq.m. (both side inclusive) as per IS:277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts other flange of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.8mm running at the rate of 1200mm centre to centre to which the ceiling section of 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channelwith connecting clips made out of 2.64mm dia x 230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs of 450mm centre, with 25mm long dry wall screws@ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230mm c/c, including jointing and flushing to a flush finish of tapered and squre edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm or both sides of joint and including the cost of painting one coat primer and two coats of emulsion paint of approved colour, all asper manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and as direted by the Engineer-in-Charge.
Design,Providing and Fixing of 12mm one side laminate skirting for a height of 150mm Matt finish etc., complete all as directed by EIC.
Design,Providing and Fixing wooden laminated skirting of size 100x15mm, top end curved shape of make 'Krone' or approvrd equivalent using nailing/adhesive tapes as per manufacturers requirement complete all as directed by the Enginner-in-Charge.
Supply of Tip-up & Back push recliner chairs. Center to center 508 mm. Plywood (hardwood) with induction heating and high pressure pressed. ABS moulded housing for seat & back cushions. Armrest Made of PP/PPCP/ABS or semi rigid PU foam. LED lights on sides along with aisles. 100% polyester synthetic fabric with 4 mm polyurethane foam lamination. Properties: Fire retardant - Standard – ISO3795, FMVVSS302 Water repellent - Standard - AATCC193 – Drop test Polyurethane injection moulded flexible Foam Seat and Back density 50 – 55 kg/m3. Torsion spring / spring steel IS: 4454 1981 Grade III. HRCA Bars Electrostatic epoxy Coating thickness: 70 - 80 microns
Supply & fixing of Frameless Glass Door using Dorma Patch fittings (With BTS 75v), Handle - H -Type (450mm) and 10mm thick clear Toughened glass and with Wall Connecting Profile and sealent with proper level, labour for installation fixing all complete and as directed by the Engineer-in-Charge.
Supply & fixing of frameless Fixed panel using Dorma wall connecting profile - non secure version of 10mm thick clear Toughened glass using adequate sealants with proper level, labour for installation fixing all complete and as directed by the Engineer-in-charge.
Supply of Tip-up & Back push recliner chairs. Made with special high-quality engineering plastics, Responds automatically to body movement by flexing seat and back to suit body posture with back tilt limit to suit variety of tasks, Seat height can be adjusted to suit the user and with adjustable armrest. Plywood (hardwood) with induction heating and high pressure pressed. ABS moulded housing for seat & back cushions. Armrest Made of PP/PPCP/ABS or semi rigid PU foam. LED lights on sides along with aisles. 100% polyester synthetic fabric with 4 mm polyurethane foam lamination. Properties: Fire retardant - Standard – ISO3795, FMVVSS302 Water repellent - Standard - AATCC193 – Drop test Polyurethane injection moulded flexible Foam Seat and Back density 50 – 55 kg/m3. Torsion spring / spring steel IS: 4454 1981 Grade III. HRCA Bars Electrostatic epoxy Coating thickness: 70 - 80 microns 1. Sample colour shall be got approved before commencing the work. 2. The above work shall be got executed from approved manufacturer only.
Stage Desk : Making and supplying stage desk. Made with HDF and with Melamine finish. Comforatable seating accomodation for 8 people. L 94.8 in X W 47.1 in X H 29.6 in
Podium : Made of 25mm thick plywood for top, Verticals and a shelf with stage matching lamination, veneer with melamine polish .SIZE: 42" X 21" depth and 30" width front semi circle. The podium front and side fully covered with design , Architect and complete as per disscussion.
BACK HORIZONTAL CURTAIN: 37X19FT Supply, installation and commissioning of front curtain with Horizontal sliding arrangement complete with fixing- rail tract, “Y”- bracket runners, master runner, steel rope for whole system, 1 Hp Crompton greave motor, aluminum gear box 1:40 ratio having gun metal gear ,aluminum groove drum, Single pulley spring loaded, double pulley with bracket, Siemens/L & T contactors, auto limit cut out switches,3nos LED ILUMINATED push switch, fasteners and extras. Working of curtain should control with forward / stop / reverse operation. Curtain made out of VELVET CLOTH material. Curtain should be stitched in pleated with having an overlap of 2ft in center on either tract.
FOH LIGHT BAR: 30 X 1 FT -1noLADDER type structure FOH bar placed outside the stage area hanging from the top ,35mm round M.S pipe Is used. pipe is hanged from the ceiling. Bars are suspended using the M.S angle, anchor bolt rawalt type M10 bolt. FRAME IS MADE COMFORTABLE FOR DISMANTLE OR ADDON TYPE .
TOP FRILL 3 NOS SIZE 37' X 3' FEET above stage area with Superior quality jersycloth 120 mt tailoring, stiching charges including materials cost all complete as per specifications and directed by engineer-in-charge.
WINGS DOOR CURTAIN:18x4ft - 4NOS Supply, installation and commissioning of wings door curtain Made out of BLUE DRILL /BLACK OUT CLOTH MATERIAL, stitching for the width of door ,cloth will enclosed on both side of the M.S frame structure . bottom heavy duty wheel. M.S metal fabrication support work with men and material, will be carried through from the trust and side wall . door wings will be stitched plain in surface and hand stitched at the bottom.10Feet wings can be moved using G.I wire.
Providing coverage and closure for embedded parts, trench covers, connection plates by using 20mm plywood, screw system for re-oepening and fixing in position complete as per drawings and specifications.
Providing and applying painting Two coats at all levels with Acrylic emulsion paint (ACE or equivalent approved brand, colour and manufacturer) to give an even shade including one under coat of suitable primer, applying putty, preparation of the surfaces, scaffolding complete all as per specifications and as directed by EIC.
Providing and applying painting One coats at all levels with Acrylic emulsion paint (ACE or equivalent approved brand, colour and manufacturer) to give an even shade including one under coat of suitable primer, applying putty, preparation of the surfaces, scaffolding complete all as per specifications and as directed by EIC.
Providing and applying painting One coats at all levels with Acrylic emulsion paint (ACE or equivalent approved brand, colour and manufacturer) to give an even shade including applying putty, preparation of the surfaces, scaffolding complete all as per specifications and as directed by EIC.
Providing, fabricating and fixing Hand rail using 304 grade stainless steel pipes, Square sections and sheets for toe gaurds etc. of approved size and make and quality by cutting to required size, welding, mirror/matt polishing, fixing at site etc. for balcony railing and staircase railings including special sections as per drawings, specificatiopns complete. A sample to be fabricated and to be got approved by the EIC before starting of work at site. This work to be executed through approved specialized agency.
Providing and fixing glazing with 5 mm thick clear float glass pane in aluminium doors,window, ventilator shutters and partitions etc.with neoprene gasket including cost of neoprene gasket complete as per the drawings and direction of the EIC.
Dismantling brick work in cement mortar at all levels by manually / by mechanical means, carefully without damaging adjacent structures including stacking of serviceable materials and disposal of unserviceable materials within 50m lead all as per specifications and directed by the Engineer -in -charge.
Dismantling of RCC works at all levels all levels by manually / by mechanical means,including cutting and stacking of steel reinforcement bars and disposal of unserviceable materials within 50m lead all as per specifications and directed by the Engineer -in -charge.
Providing and constructing brick masonry using well burnt stock bricks in cement mortar 1:5 including suitable scaffolding, raking out joints, curing etc. complete as per specifications and drawings for foundation, superstructure, etc. for Basement and Ground floor.
Providing plastering to the external/ internal faces of brick work / R.R masonry/concrete in cement mortar 1:5, 12mm thick at all elevations including hacking of cement surface with hacking tool, scaffolding, curing, forming grooves wherever required etc. complete as per specifications and drawings.
Painting the RCC screen wall (size 12x7m) with necessary wall putty for levelling the undulations 10 to 20 mm thickness, sanding, cleaning, smoothening and applying two coats of premium plastic emulsion paint of approved make and colour over a coat of primer all including scaffolding, necessary putty, materials and labour complete as per specifications and as instructed by Engineer-in-charge.
Dismentling doors, windows and clear storey openings(Steel/ wood/ Aluminium) shutter at all levels including chowkhats, architraves, holdfasts etc. Complete and stacking within 50m lead (full windows) of area above 3.00 sq.m. All as per specifications and directed by the Engineer-in-charge.
Providing F3 finish over concrete surfaces in cement mortar 1:1.5 (1 part cement: 1.5 part fine sand) including wetting the surface, labours, curing, all materials, scaffolding al all elevations complete all as per specification and as directed by the Engineer-in-charge.
Providing and laying cast in situ controlled reinforced cement concrete of M30 grade at all levels and lifts mentioned below, using 20 mm maximum size hard granite machine crushed graded stone aggregates, including weigh batching,charges for mixing and cost of admixture, mechanical mixing, transporting and placing, at all lifts, vibrating, consolidating, curing, finishing smooth, of all exposed faces complete for column footing, column, lintel, sunshade, getter slab, beams, slabs, water tank, machin foundation, trench raft, trench cover slabs and all other structural elements including dewatering werever necessary all as per specification and all as shown in drawings and as directed by the engineer incharge for all insitu item. Note: 1.The rate of concrete shall include all labour, equipment, charges of mixing & cost of admixture.Chemical admixture confirming to IS 9103 shall be mixed in fresh concrete and prior permission from engineer - in -charge shall be obtained for dosage and compatibility. 2.Test certificate of cement, procued from dealer/company to be submitted for all cement related works by the contractor. 3.The rate shall be quoted on the basis of use of 370Kg of cement per Cu.m concrete. Any upward ,downward variation required to obtain the specified strength will be paid for or deducted at the rate of Rs.6.00 per Kg of cement.
Providing and laying cast flexible LED Strip Light .W Power consumption in 5mtrs length CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver non integrated, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved with 2 years Warranty against any manufacturing defect working under standard electrical condition. complete with all lead & lifts complete as per specification and directions of the Engineer in charge of the work.
Supply and installation of Panasonic / RealPresence Group 700 - 720p: Group 700 HD codec, EagleEyeIV-L camera, mic array, univ. remote. Cables: 1 HDMI 1.8m, 1 CAT 5E LAN 3.6m,1 HDCI digital 3m.Maintenance Contract Required. Power Cord Required. For SEA and India only. Power Cord: India, BIS `Type C, CE 7/7, Group Series 1080p HD License-1080 encode/decode for people and content. Valid for Group 3x0, 500, 550, 700 incluing all other equipments connectivity like audio, video, multiplexer, projector, display units & audio mixer, video mixer etc is in the scope of supplier and should quote accordingly.
Agmatel India Pvt.Ltd
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .