Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAdmitted-Finance | ₹35.6 L | L1 | Admitted-Finance |
| 2 | L2₹39.6 LAdmitted-Finance | ₹39.6 L | L2 | Admitted-Finance |
| 3 | L3₹40.0 LAdmitted-Finance | ₹40.0 L | L3 | Admitted-Finance |
| 4 | L4₹42.3 LAdmitted-Finance | ₹42.3 L | L4 | Admitted-Finance |
| 5 | L5₹45.8 LAdmitted-Finance | ₹45.8 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SHRI GANESH ENTERPRISES L3 | MS ENTERPRISES L6 | M/s K L M INFRATECH L4 | Srinivasa Consructions L8 | BHAGYARAM ENTERPRISES L1 | SHILPA CONSTRUCTION COMPANY L5 | M/S J J ENTERPRISES L7 | MM PROJECTS L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting the electric supply to the transformer, opening the transformer by unscrewing bolts from the top cover of the transformer,draining out of transformer oil into a container upto required level for arresting the leakage in the transformer, taking down of unserviceable HV and LV bushes from the transformer if necessary, replacement of top cover gasket, HV and LV side bushes gasket, buchholz relay gasket,bolts, nuts and washers, with new ones required soldering work if necessary while fixing the bushes, and re-fixng the same for transformer capacity ranging upto 1250 KVA complete including testing the transformer after repairs all as specified and directed.
Note: (i) HT / LT metal studs, HT / LT bushes and gaskets of HT and LT side will be measured and paid for seperately.
(ii) Nuts, bolts, washers, petrolium jelly, grease, CTC required are deemed to be included in the unit rate quoted. (iii) Filteration of drained out transformer oil will be measured and paid for separately. | 5 | Each Job | 3,000 ₹15,000 | 9,663 ₹48,315 | 7,000 ₹35,000 | 10,000 ₹50,000 | 5,000 ₹25,000 | 7,332 ₹36,660 | 10,000 ₹50,000 | 5,000 ₹25,000 |
| 2.00 | Supply and fix HT porcelain bush rods suitable for any make of transformers capacity upto 1250 KVA capacity all as directed by Engineer-in-Charge | 5 | Each | 2,500 ₹12,500 | 5,663 ₹28,315 | 650 ₹3,250 | 1,000 ₹5,000 | 900 ₹4,500 | 654 ₹3,270 | 2,000 ₹10,000 | 450 ₹2,250 |
| 3.00 | Supply and fix LT porcelain bush rods suitable for transformers of any make and of capacity upto 1250 KVA all as specified and directed. | 5 | Each | 1,000 ₹5,000 | 5,993 ₹29,965 | 900 ₹4,500 | 6,000 ₹30,000 | 950 ₹4,750 | 897 ₹4,485 | 3,500 ₹17,500 | 700 ₹3,500 |
| 4.00 | Supply only set of top cover gasket for transformers of capacity upto 1250 KVA all as specified and directed by Engineer-in-Charge. | 5 | Each | 1,500 ₹7,500 | 3,933 ₹19,665 | 1,800 ₹9,000 | 6,000 ₹30,000 | 3,000 ₹15,000 | 1,851 ₹9,255 | 1,500 ₹7,500 | 1,250 ₹6,250 |
| 5.00 | Disconnecting the electric supply, removing the HT and LT cable connections and taking out the transformer of capacity upto 1250 KVA from the platform, lifting the transformer with suitable crane, loading into the goods carrier and shifting the transformer to an approved factory (workshop) for reairs and transporting back installation in its original location including connection of HT and LT cable connections all as directed by Engineer-in- Charge.
Note : Repairs to tranformer and testing will be measured and paid for separately | 1 | Each Job | 35,000 ₹35,000 | 9,963 ₹9,963 | 40,000 ₹40,000 | 25,000 ₹25,000 | 50,000 ₹50,000 | 43,836 ₹43,836 | 10,000 ₹10,000 | 40,000 ₹40,000 |
| 6.00 | M&L for draining out the transfomer oil, removing the inspection cover, lifting the core with suitable crane and removing the winding from the core replacing the unserviceable insulation of LV coil, HV coil and rewinding the unserviceable HV, LV coil turns with new electrolytic copper conductor, drying of core and winding in the oven upto required IR values, assembling the core with new insulation, replace the unserviceable LT, HT bushing washers, oil seal, gaskets of inspection cover with new ones, conduct all testing, commissioning complete upto 1250 KVA Transformer all as directed by Engineer-in-Charge.
Note : HT / LT bush, transformer oil, LV, HV coils, inspection cover gasket and testing of transformer will be measured and paid separately under relevant items. | 1 | Each Job | 60,000 ₹60,000 | 12,993 ₹12,993 | 90,000 ₹90,000 | 50,000 ₹50,000 | 25,000 ₹25,000 | 86,100 ₹86,100 | 1,00,000 ₹1 L | 75,000 ₹75,000 |
| 7.00 | M&L for making LT coil insulation with required gauge of craft paper cotton tape as per specification of old transformer of capacity upto 1250 KVA complete all as directed by Engineer -in-Charge. | 320 | KG | 100 ₹32,000 | 193 ₹61,760 | 160 ₹51,200 | 200 ₹64,000 | 85 ₹27,200 | 150 ₹48,000 | 100 ₹32,000 | 150 ₹48,000 |
| 8.00 | M&L for making HT coil insulation with required gauge of craft paper cotton tape as per specification of old transformers capacity complete all as specified and directed by Engineer -in-Charge. | 370 | KG | 100 ₹37,000 | 193 ₹71,410 | 150 ₹55,500 | 200 ₹74,000 | 85 ₹31,450 | 141 ₹52,170 | 100 ₹37,000 | 150 ₹55,500 |
| 9.00 | M&L for making HT coil insulation with copper wire of required gauge as per specification of old transformers capacity complete all as specified and directed by Engineer -in-Charge. | 690 | KG | 1,550 ₹10.7 L | 893 ₹6.2 L | 1,000 ₹6.9 L | 1,000 ₹6.9 L | 900 ₹6.2 L | 1,221 ₹8.4 L | 1,700 ₹11.7 L | 1,100 ₹7.6 L |
| 10.00 | M&L for conducting the following tests after repairs of transformers capacity upto 1600 KVA including submitting the test report.
(a) I.R values of HV to LV, HV to Earth and LV to Earth.
(b) winding resistance.
(c) Ratio test
(d) No-load test
(e) Short circuit test
(f) Dielectric strength of oil
(g) Transfomer tap switch positions
Note: contractor shall arrange all measuring instuments / equipment for testing of transformer. | 1 | Job | 10,000 ₹10,000 | 16,993 ₹16,993 | 10,000 ₹10,000 | 13,000 ₹13,000 | 5,000 ₹5,000 | 11,508 ₹11,508 | 10,000 ₹10,000 | 10,000 ₹10,000 |
Updated dates
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
30 Mar 2026, 6:00 pmClosed
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIRS AND REPLACEMENT OF SPARES TO DISTRIBUTION TRANSFORMER SWITCH GEARS LT HT UG CABLES AT NAVIGATION DNEC FOG BLDGS OF EMU UNDER GE I RND RCI HYDERABAD
2026_MES_754970_1
8389
Open Tender
Electrical and Maintenance Works
180 days
GE(I) R AND D RCI, HYDERABAD
MES enlisted Class D category b ii and Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹96,000
Yes
16 Apr 2026
2 Mar 2026
1 Apr 2026
2 Mar 2026
30 Mar 2026
16 Mar 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: GE(I) R&D RCI HYDERABAD
Name of Work: REPAIRS AND REPLACEMENT OF SPARES TO DISTRIBUTION TRANSFORMER, SWITCH GEARS, LT / HT UG CABLES AT NAVIGATION, DNEC, FOG BLDGS OF EMU UNDER GE (I) R&D RCI, HYDERABAD
Contract No: GE(I) RCI/HYD/ OF 2025-2026
Sl No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Basic Rate In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category
Disconnecting the electric supply to the transformer, opening the transformer by unscrewing bolts from the top cover of the transformer,draining out of transformer oil into a container upto required level for arresting the leakage in the transformer, taking down of unserviceable HV and LV bushes from the transformer if necessary, replacement of top cover gasket, HV and LV side bushes gasket, buchholz relay gasket,bolts, nuts and washers, with new ones required soldering work if necessary while fixing the bushes, and re-fixng the same for transformer capacity ranging upto 1250 KVA complete including testing the transformer after repairs all as specified and directed. Note: (i) HT / LT metal studs, HT / LT bushes and gaskets of HT and LT side will be measured and paid for seperately. (ii) Nuts, bolts, washers, petrolium jelly, grease, CTC required are deemed to be included in the unit rate quoted. (iii) Filteration of drained out transformer oil will be measured and paid for separately. 5 Each Job Excess(+) Full Conversion INR
Supply and fix HT porcelain bush rods suitable for any make of transformers capacity upto 1250 KVA capacity all as directed by Engineer-in-Charge 5 Each Excess(+) Full Conversion INR
Supply and fix LT porcelain bush rods suitable for transformers of any make and of capacity upto 1250 KVA all as specified and directed. 5 Each Excess(+) Full Conversion INR
Supply only set of top cover gasket for transformers of capacity upto 1250 KVA all as specified and directed by Engineer-in-Charge. 5 Each Excess(+) Full Conversion INR
Disconnecting the electric supply, removing the HT and LT cable connections and taking out the transformer of capacity upto 1250 KVA from the platform, lifting the transformer with suitable crane, loading into the goods carrier and shifting the transformer to an approved factory (workshop) for reairs and transporting back installation in its original location including connection of HT and LT cable connections all as directed by Engineer-in- Charge. Note : Repairs to tranformer and testing will be measured and paid for separately 1 Each Job Excess(+) Full Conversion INR
M&L for draining out the transfomer oil, removing the inspection cover, lifting the core with suitable crane and removing the winding from the core replacing the unserviceable insulation of LV coil, HV coil and rewinding the unserviceable HV, LV coil turns with new electrolytic copper conductor, drying of core and winding in the oven upto required IR values, assembling the core with new insulation, replace the unserviceable LT, HT bushing washers, oil seal, gaskets of inspection cover with new ones, conduct all testing, commissioning complete upto 1250 KVA Transformer all as directed by Engineer-in-Charge. Note : HT / LT bush, transformer oil, LV, HV coils, inspection cover gasket and testing of transformer will be measured and paid separately under relevant items. 1 Each Job Excess(+) Full Conversion INR
M&L for making LT coil insulation with required gauge of craft paper cotton tape as per specification of old transformer of capacity upto 1250 KVA complete all as directed by Engineer -in-Charge. 320 KG Excess(+) Full Conversion INR
M&L for making HT coil insulation with required gauge of craft paper cotton tape as per specification of old transformers capacity complete all as specified and directed by Engineer -in-Charge. 370 KG Excess(+) Full Conversion INR
M&L for making HT coil insulation with copper wire of required gauge as per specification of old transformers capacity complete all as specified and directed by Engineer -in-Charge. 690 KG Excess(+) Full Conversion INR
M&L for conducting the following tests after repairs of transformers capacity upto 1600 KVA including submitting the test report. (a) I.R values of HV to LV, HV to Earth and LV to Earth. (b) winding resistance. (c) Ratio test (d) No-load test (e) Short circuit test (f) Dielectric strength of oil (g) Transfomer tap switch positions Note: contractor shall arrange all measuring instuments / equipment for testing of transformer. 1 Job Excess(+) Full Conversion INR
Supply and replace of unserviceable transformer oil conforming to IS: 335 (1993), dielectric strength not less than 60 KV at 2.5 mm gap in various capacities distribution transformers installed at various indoor and outdoor sub stations complete all as specified and directed. Make: Power oil / SERVO / Castrol / Shell. 1000 Ltr Excess(+) Full Conversion INR
Supply and topping up transformer oil conforming to IS: 335 (1993), dielectric strength not less than 60 KV at 2.5 mm gap in various capacities distribution transformers installed at various indoor and outdoor sub stations complete all as specified and directed. Make: Power oil / SERVO / Castrol / Shell. 2500 Ltr Excess(+) Full Conversion INR
Dehydration of transformer oil of various capacities distribution transformers installed at various indoor and outdoor transformers with ultra high vaccum filtration machine to obtain the dielectric strength of 60 KV at 2.5 mm gap complete all as specified and directed. 10000 Ltr Excess(+) Full Conversion INR
M&L, locating fault in 11 KV HT underground cable of any sizes with the help of fault locator vehicle organized from TSSPDCL/TSTRANSCO by injecting necessary high voltage to the faulty cable within 12 hours of time from time of reporting of fault all as directed by Engineer in Charge. Note : Quoted rate shall deemed to be included the necessary charges towards liaisoning for arranging fault locating vehicle, transportation of trained technicians and charges payable to Electricity Department. 15 Each Job Excess(+) Full Conversion INR
M&L for painting to body of distribution transformers and Bus Bar Trunking to LT Panel of capacities ranging upto 1250 KVA installed at indoor and outdoor substations with one coat of synthetic enamel Grey / Green (Existing type) paint using spray gun machine after removing all dust and rust complete all as directed by Engineer-in-charge. Make of paint : Shalimar / Asian / Berger 6 Each Job Excess(+) Full Conversion INR
Taking down the defective air breathers from the transformers, supply and fix new breathers with flange type 1/2 Kg bottle suitable for step down distribution transformers of any make and capacity ranging from 63 KVA to 500 KVA including filling of new silica gel in breathers complete all as specified and directed. 4 Each Excess(+) Full Conversion INR
All as per item No 16 above but of capacity above 500 KVA and upto 1000 KVA, 1 Kg bottle 8 Each Excess(+) Full Conversion INR
18. All as per item No 16 above but of capacity above 1000 KVA and upto 3500 KVA, 2 Kg bottle 10 Each Excess(+) Full Conversion INR
Opening of LT panel board, disconnecting and removing of the burnt out cable end terminations, cutting and reterminating of the cable end portions with proper size of lugs and decarbonising of panel busbar and cleaning with CTC, replacing of cable glands, connecting back cable end termination properly, opening of the busbar chambers, cutting removing of the cable connections, reterminating with proper size of lugs, tightening of the bus bar nuts, bolts including wrapping of the busbar with colour codes, checking of all switches, MCCBs all isolators, tightening of the loose connections replacing of burnt out fuse, cut out fuses with new ones complete all as directed by Engineer-in-Charge. 5 Each Job Excess(+) Full Conversion INR
Supplying, laying, jointing, testing and commissioning of 3 Core 120 Sqmm, 11000 volts grade, Earthed, HT XLPE insulated, insulation screened with extruded semi-conducting compound in combination with copper tape (0.3 KA for one second), cores laid up, PVC inner sheath with fillers, galvanized steel flat strip armoured, heavy duty, electric cables, with multistranded aluminium conductor, conductor screen with extruded semi conducting compound and overall PVC sheathed cable as per IS-7098 (Part-2) 1988 with latest amendments, replaced with burntout HT Cable laid in trenches / passing through pipe/duct/road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., including disconnecting and taking down unserviceable cable complete all as specified and directed for the following sizes:- Note : Earthwork Excavation, sand cushioning, GI pipe and cable protection will be measured and paid separately. 450 RM Excess(+) Full Conversion INR
Supplying, laying, jointing, testing and commissioning of 3.5 Core 400 Sqmm, 1100 volts grade, Earthed, LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade replaced with burntout LT Cable laid in trenches / passing through pipe / duct / road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., including disconnecting and taking down unserviceable cable complete all as specified and directed. Note : Earthwork Excavation, sand cushioning, GI pipe and cable protection will be measured and paid separately. 400 RM Excess(+) Full Conversion INR
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in hard/dense sol complete all as specified and directed. CUM Excess(+) Full Conversion INR
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cms complete all as specified and directed. CUM Excess(+) Full Conversion INR
Removal of excavated soil to a distance not exceeding 50 mtrs and deposited where directed at a level not exceeding 1.5mtrs above the starting point all as directed. CUM Excess(+) Full Conversion INR
Supply and spread natural dry river sand for cable cushioning in trenches and punned down all as specified and directed. Note : Prunned thickness will be measured for payment. CUM Excess(+) Full Conversion INR
Supply and lay un reinforced pre cast concrete cable cover class HV type I flat size 300X180mmX40mm all as specified and directed. Each Excess(+) Full Conversion INR
Supply and lay un reinforced pre cast concrete cable cover class Class LV, Type I, flat, size 250 mm x 150mm x 40mmall as specified and directed. Each Excess(+) Full Conversion INR
Cutting of existing bituminious / PCC road or flooring / plinth protection, for laying of GI pipe in road intersection for passing of HT XLPE cable including excavation in any type of soil, returning and filling in and making good top 30cm of the trench by providing PCC 1:2:4 type B1 using 20mm graded stone aggregate to flush with existing road surface complete all as directed. 30 RM Excess(+) Full Conversion INR
S&F, 150mm dia GI pipe light grade fixed to walls / poles or laid in trenches, road crossing etc., for protection of underground cable/earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls/poles complete all as specified and directed 30 RM Excess(+) Full Conversion INR
Disconnecting and cutting down the existing unserviceable / burnt out HT cable end joints, outdoor type (Heat shrinkable) 11 KV grade suitable for XLPE cables of size 120 Sqmm, 3 core and supply and jointing new HT cable end joint of size 120 Sqmm, 3 core, outdoor type (Heat shrinkable) including testing complete all as specified and directed. Make : RAYCHEM / M-SEAL / DENSON 2 EACH Excess(+) Full Conversion INR
All as per item No 30 above, but for indoor type. Make : RAYCHEM / M-SEAL / DENSON 2 EACH Excess(+) Full Conversion INR
All as per item No 30 above, but for 3 core, 95 Sqmm outdoor type. Make : RAYCHEM / M-SEAL / DENSON 2 EACH Excess(+) Full Conversion INR
All as per item No 30 above, but for indoor type. Make : RAYCHEM / M-SEAL / DENSON 3 EACH Excess(+) Full Conversion INR
Cutting the burnt out portion of the HT underground XLPE cable of 120 Sq mm 3 core, supply and jointing HT cable straight through joints (Heat shrinkable) 11 KV grade suitable for XLPE cables of size 120 Sqmm, 3 core including testing complete all as specified and directed. Make : RAYCHEM / M-SEAL / DENSON 9 EACH Excess(+) Full Conversion INR
All as per item No 34 above, but for 3 core, 95 Sqmm Make : RAYCHEM / M-SEAL / DENSON 8 EACH Excess(+) Full Conversion INR
M&L in repairs, Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected to copper strip 20x3mm as earth lead by means of bolts, nuts, washers and check nuts made out of galvanized iron or steel all as shown on Electrical Plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed. Note 1: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, 50mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 25mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 422 of SSR Part-II. 2. Copper earth strip beyond 7.5m will be measured and paid separately. 15 Each Excess(+) Full Conversion INR
M&L in repairs, copper earth strip 20 x 3mm buried in ground or fixed on wall or drawn through pipe or fixed to poles or any other indicated situation for earthing complete all as specified and as directed. 50 RM Excess(+) Full Conversion INR
Supply and replacement of unserviceable rubber matting with new one of 12mm thick 1M X2 M LT ISI marked complete all as specified and directed by Engineer -in-Charge 2 Each Excess(+) Full Conversion INR
Supply and replacement of unserviceable HT rubber mat with new one of of size 1mx2mx19mm ISI marked complete all as specified and directed by Engineer -in-Charge. 5 Each Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_845592.pdf
techsummary_845592.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
BOQ_845592.xls
BOQ • 0.30 MB
8389PS.pdf
Tender Documents • 0.36 MB
Download all tender documents and submit your bid