| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-Finance | ₹12.3 L | L1 | Accepted-Finance ok |
| 2 | L2₹12.5 L+₹11,037.72 (0.89%)Accepted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | ₹12.5 L+₹11,037.72 (0.89%) | L2 | Accepted-Finance ok |
| Sl No | Description | Qty | Unit | Premier Engineering Company L2 | STANDARD CAPACITORS L1 |
|---|---|---|---|---|---|
| 1.00 | Dismantling of defective components like capacitors, relays, contactors, indication lights, etc. from 2 nos. APFC panels including dismantling of terminations, wirings, hardware etc. as required at site. | 2 | Job | 26,000 ₹30,680 | 25,000 ₹29,500 Lowest |
| 2.00 | Supply of Super Heavy-duty capacitors of various capacities rated at 440V, 50 Hz, 3 phase AC complete with terminal cover and discharge device for replacement of defective capacitors in various stages of APFC panels as required at Site - make standard. | 150 | kvar | 75,000 ₹88,500 | 74,700 ₹88,146 Lowest |
| 3.00 | Banking of capacitor units to form banks of suitable capacity by electrical interconnection with multistrand copper wires/aluminium bus bars using necessary hardware, lugs, tapes etc. as required at site. | 150 | kvar | 22,500 ₹26,550 | 21,750 ₹25,665 Lowest |
| 4.00 | Supply of microprocessor based, 12 step APFC relay with digital display of power factor and other parameters to replace defective relay for providing phased impulses to contactor coils on receipt of low or high-power factor signal from the control CT - make "standard". | 2 | Nos | 47,000 ₹55,460 | 46,736 ₹55,148.48 Lowest |
| 5.00 | Control wiring of APFC relay with multistrand copper wire of 1.5 mm sq. size from relay connectors to various contactor coils to replace defective / burnt out control wiring as required at site. | 2 | Job | 23,300 ₹27,494 | 23,000 ₹27,140 Lowest |
| 6.00 | Replacement of triple pole MCCB of 250A capacity for operation and safety of individual capacitor bank - make L&T/Standard/Havells. | 1 | Nos | 30,000 ₹35,400 | 29,450 ₹34,751 Lowest |
| 7.00 | Supply of 15 kVAr capacitor duty contactor or equivalent make to replace defective contactors in various stages of APFC panels L&T/Havells/TDK/Standard. | 3 | Nos | 11,100 ₹13,098 | 11,070 ₹13,062.6 Lowest |
| 8.00 | Supply of 25 kVAr capacitor duty contactor or equivalent make to replace defective contactors in various stages of APFC panels L&T/Havells/TDK/Standard. | 4 | Nos | 18,000 ₹21,240 Lowest | 20,200 ₹23,836 |
| 9.00 | Supply of TP MCBs up to 63A rating to replace defective MCB of various stages of APFC panels - make L&T/Havells/EPCOS/Standard. | 4 | Nos | 9,200 ₹10,856 Lowest | 9,440 ₹11,139.2 |
| 10.00 | Supply of Indication lights of various colours to replace defective indication lights of various stages of APFC panels as required at site - make FTC/Vaishno/Teknik. | 20 | Nos | 2,000 ₹2,360 Lowest | 2,300 ₹2,714 |
Tender Value
Refer Docs
EMD Value
₹25,500
Closing Date
3 Aug 2026, 2:30 pmClosed
EE EnM HP I
DELHI JAL BOARD GOVT OF NCT OF DELHI OFFICE OF THE EXECUTIVE ENGINEER EnM HP I HAIDERPUR WATER WORKS DELHI 110085
Improvement of Power factor through Standard make APFC panels installed at CWPH and Filter House Bawana WTP.
2026_DJB_295932_12
NIT NO. 04(2026-27) HP-I
Open Tender
Miscellaneous Works
Works
EE EnM HP I
Please refer tender documents
3 documents required · 3 mandatory
₹500
SAB PAISA PORTAL Ac No. 50448339804
₹25,500
6 Aug 2026
27 Jul 2026
3 Aug 2026
27 Jul 2026
3 Aug 2026
27 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of defective components like capacitors, relays, contactors, indication lights, etc. from 2 nos. APFC panels including dismantling of terminations, wirings, hardware etc. as required at site. | 2 | Job | - | - |
| 2 | Supply of Super Heavy-duty capacitors of various capacities rated at 440V, 50 Hz, 3 phase AC complete with terminal cover and discharge device for replacement of defective capacitors in various stages of APFC panels as required at Site - make standard. | 150 | kvar | - | - |
| 3 | Banking of capacitor units to form banks of suitable capacity by electrical interconnection with multistrand copper wires/aluminium bus bars using necessary hardware, lugs, tapes etc. as required at site. | 150 | kvar | - | - |
| 4 | Supply of microprocessor based, 12 step APFC relay with digital display of power factor and other parameters to replace defective relay for providing phased impulses to contactor coils on receipt of low or high-power factor signal from the control CT - make "standard". | 2 | Nos | - | - |
| 5 | Control wiring of APFC relay with multistrand copper wire of 1.5 mm sq. size from relay connectors to various contactor coils to replace defective / burnt out control wiring as required at site. | 2 | Job | - | - |
| 6 | Replacement of triple pole MCCB of 250A capacity for operation and safety of individual capacitor bank - make L&T/Standard/Havells. | 1 | Nos | - | - |
| 7 | Supply of 15 kVAr capacitor duty contactor or equivalent make to replace defective contactors in various stages of APFC panels L&T/Havells/TDK/Standard. | 3 | Nos | - | - |
| 8 | Supply of 25 kVAr capacitor duty contactor or equivalent make to replace defective contactors in various stages of APFC panels L&T/Havells/TDK/Standard. | 4 | Nos | - | - |
| 9 | Supply of TP MCBs up to 63A rating to replace defective MCB of various stages of APFC panels - make L&T/Havells/EPCOS/Standard. | 4 | Nos | - | - |
| 10 | Supply of Indication lights of various colours to replace defective indication lights of various stages of APFC panels as required at site - make FTC/Vaishno/Teknik. | 20 | Nos | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
BOQ_393855.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .