Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L5₹52.2 L+₹14.6 L (38.8%)Accepted-AOC 1108 CHOTA BAZAR MHOW MP PIN 453441 | MHOW | INDORE | MADHYA PRADESH | 453441 | L5 | Accepted-AOC was accepted by mistake, so reject | |
| 3 | L2₹43.3 L+₹5.7 L (15.1%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 4 | L3₹43.4 L+₹5.8 L (15.4%)Rejected-Finance | L3 | Rejected-Finance High Rate | |
| 5 | L4₹47.9 L+₹10.3 L (27.4%)Rejected-Finance 10 2 NARAYAN BAG INDORE M P | L4 | Rejected-Finance High Rate |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 May 2022, 6:00 pmClosed
GE (MCTE) Mhow
GE (MCTE) Mhow (MP) 453441
CERTAIN REPAIR / MAINTENANCE OF EXTERNAL ELECTRIFICATION AT WESTERN AREA UNDER GE MCTE MHOW
2022_MES_519611_1
GE (MCTE)/MHOW/06(T) OF 2022-23
Open Tender
Electrical and Maintenance Works
Works
180 days
GE (MCTE) Mhow
As Per Tender Document
9 documents required · 9 mandatory
₹500
Yes
GE (MCTE) Mhow
₹80,000
Yes
29 Jun 2022
23 Apr 2022
20 May 2022
23 Apr 2022
18 May 2022
5 May 2022
Amount
Excavation in trenches not exc. 1.5 Mtr wide and not exc 1.5 Mtr deep in any type of soil and getting out complete all as specified and directed.
All as above, but depth exc 1.5 Mtr and not exc 3.0 Mtr deep all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
Removing surplus excavated soil material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed.
M&L for filling approved fine river sand in trenches as cable cushion to the full width of excavated trench, under and over cable complete all as specified directed. (Note : Punned thickness of sand shall be measured)
M&L for bricks slightly over burnt (kiln burnt) , modular bricks, best quality, locally available, laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection all as specified directed.
Taking out existing stone aggregate of any description cleaning / removing the grass, vegetation etc, leveling the ground, well ramming and finally spreading the aggregate uniformly all as directed.
Supply and spreading graded stone aggregate of size 40 mm for transformer yard complete all as specified and directed.
Taking down damaged PCC/steel pole/strut of any size all as specified and directed.
M&L for steel tubular swaged poles complete with MS base plate, finial taper plug, bolts, nuts & screws type 410, SP-31 (9 mtrs long), erected to truely vertical position, painting externaly embedded portion in PCC with black bitumenous paint and externally exposed to surfaces with aluminium paint in two coats, making five alternate strips 30cm wide with black and yellow paint in two coats, marking MES number with black paint complete all as specified and directed. (Note : Excavation and PCC will be measured and paid for separately under respective items of this schedule)
Dismantling old unserviceable cross arms, bracings etc of any section and size incl nuts, bolts etc complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates etc fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for fixing insulaters and painting with aluminium paint two coats over one coat of red oxide zinc chrome primer complete all as specified and directed.
M&L in replacement of chain link fencing with two coats aluminum paint over a coat of red-oxide complete including taking down of old chain link fencing all as specfied and directed.
M&L for PCC 1:4:8, type D2 ( using 40 mm graded crushed stone aggregate) as in base, foundation filling of the pole, all as specified and directed.
M&L for PCC (1:3:6), type C2 (using 40 mm graded crushed stone aggregate) as in coping for poles, etc all as specified and directed.
M & L for PCC (1:2:4), type B1 using (20mm graded crushed stone aggregate) as in coping of poles including necessary use and waste of form work and finishing exposed surfaces even and smooth complete all as specified and directed.
Taking out old unserviceable underground cable heavy duty armoured with aluminum conductor of any size and all as specified and directed.
Sppply & Laying XLPE insulated, armoured, electric cable with aluminium conductor,multi stranded 1100 volts grade, laid in trenches, fixed on poles / walls or passing through pipes including provision of necessary lugs and glands & making necessary connection complete all as specified and directed for the following:- (Note : excavtion and earth work, cable protection sand cushioning will be measured and paid seperately)
(a) 10 Sqmm, 2 core.
(b) 16 Sqmm, 2 core
(c ) 16 sqmm, 4 core
(d) 25 Sqmm, 3 1/2 core
(e) 35 Sqmm, 3 1/2 core
(f) 50 Sqmm, 3 1/2 core
(g) 70 Sqmm, 3 1/2 core
(h) 95 Sqmm, 3 1/2 core
(j) 120 Sqmm, 3 1/2 core
(k) 150 Sqmm, 3 1/2 core
(l) 185 Sqmm, 3 1/2 core
(m) 240 Sqmm, 3 1/2 core
S&F GI tubing, light grade, ISI marked 80 mm bore pipe laid in trenches/duct or in road crossing or fixed to wall/poles for protection of cable incl taking out old pipe of any grade complete all as specified and directed.
All as above but 50 mm bore pipe.
All as above but 40 mm bore pipe.
S&F MCCB, TPN, fixed thermal and fixed magnetic, 415 Volts, including taking out old unserviceable MCCB of any type and make complete of following sizes :-
(a) 40 Amps 16 kA
(b) 63 Amps 16 kA
(c) 100 Amps 16 kA
(d) 125 Amps 25 kA
(e) 150 Amps 25 kA
(f) 200 Amps 25 kA
(g) 250 Amps 25 kA
(h) 320 Amps 36 kA
(j) 400 Amps 36 kA
M&L for painting of old RCC poles cross arms after preparation of old surfaces with two coats of synthetic enamel paint of approved colour incl making alternate strips of black and yellow colour of 30 cm width each above the top of coping/GL and marking MES No with black paint complete all as specified and directed.
M&L for painting of steel tubular poles 9 / 11 m long with cross arms with two coats of aluminium paint of approved make after preparation of surfaces, making five alternate strips 30cm wide with black and yellow paint above GL/plinth and marking MES No with black paint complete all as specified and directed.
M&L for painting to old chain link fencing and steel sections post with two coats aluminum paint over a coat of aluminium red-oxide complete including preparation of old steel or iron surfaces all as specified and directed.
Cutting the existing bituminuos road for passing of UG Cable in road crossing and making good the disturbed surface of road to its original specification complete all as specified and directed.
S&F in replacement of aluminium lugs including testing complete of following sizes :-
(a) 6 Sqmm
(b) 10 Sqmm
(c) 16 Sqmm
(d) 25 Sqmm
(e) 35 Sqmm
(f) 50 Sqmm
(g) 70 Sqmm
(h) 95 Sqmm
(j) 120 Sqmm
(k) 150 Sqmm
(l) 185 Sqmm
(m) 240 Sqmm
(n) 300 Sqmm
(o) 400 Sqmm
S&F in replacement of insulator pin type, porcelain, vitreous, white or brown, including one galvanised mild steel spindle, two galvanised iron washers & one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified & directed.
S&F in repair insulator shackle type, porcelain, vitreous, white or brown or green for LT 1100 volts grade including galvanised mild steel straps of section 31 mm x 5 mm and insulator bolts 14 mm dia with washers & nuts 100 mm height & 115 mm (max) dia complete all as specified & directed.
Cutting, trimming and prunning of trees/tree branches of any girth all around existing LT over head lines / surrounding street light and flood fitting including cleaning the area beneath the LT overhead lines and removing the debris from the site and depositing where directed.
M&L for cleaning the area including uprooting of weeds/grass and removing creepers from fencing or poles / posts and brooming the complete area of sub station around panels,transformers and four pole structures all aspecified & directed.
Taking down unserviceable / burnt out MCB from existing LT Panel board duly disconnected all electrical connection & Supply and fixing new MCB SP 6-32 Amps , incl making necessary cable connection complete all as specified and directed.
Taking down unserviceable / burnt out MCB from existing LT Panel board duly disconnected all electrical connection & Supply and fixing MCB 63 Amps TPN , incl necessary cable connection complete, all as specified and directed.
Supply & laying or fixing 1100 volts grade havey duty 4 sqmm twin core flat/circular PVC insulated aluminium conductor served with an inner shething of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtrs apart.
All as above but 6 Sqmm 2 core
All as above but 10 Sqmm 2 core
Supply and jointing LT kit, heat shrink type suitable for 1100 V, XLPE, UG aluminum conductor cable of size 25 to 50 Sqmm 3.5 core and testing after jointing all as directed.
All as above but 70 to 95 sqmm dia
All as above but 120 to 240 sqmm dia
Supply and fixing cable route indicator, made of MS sheet of size 200 mm x 150 mm x 3 mm thick, spot welded with angle iron of size 40 x 40 x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B-2( using 40mm graded crushed stone aggregate) block 30cm x 30cm x 40cm in ground including one coat of synthetic enamel black paint over one coat of red oxide zinc chrome primer and writing with white paint showing size of cable HT /LT complete all as specified & directed .
Supply and errecting LT Panel outdoor type (CPRI approved) mounted and fixed with PCC foundation, made out of MS sheet factory assembled & factory fabricated out of 3.15 mm thick sheet steel with suitable size MS angel frame duly spray painted with two coats of gray synthetic enamel paint over one coat of red oxide zinc chrome primer after preparatiion of surface, with required civil works & with and including 4 Nos aluminium bus bars 600 Amps with suitable size porcelain insulators & wiring with copper cable of suitable size, connecting including indicating lamp LED type for each phase, incl in built industiral type locking arrangement, front operated and back openable incl necessry arrangement for fixing with suitable clamps, nuts & bolts etc. The panel pre wired with PVC insulated copper conductor danger notice board, feeders marked, and testing & commissioning, complete consisting of the following :-
All as above but following capacity :-
Supply and errecting LT Panel outdoor type (CPRI approved) mounted and fixed with PCC foundation, made out of MS sheet factory assembled & factory fabricated out of 3.15 mm thick sheet steel with suitable size MS angel frame duly spray painted with two coats of gray synthetic enamel paint over one coat of red oxide zinc chrome primer after preparatiion of surface, with required civil works & with and including 4 Nos aluminium bus bars 600 Amps with suitable size porcelain insulators & wiring with copper cable of suitable size, connecting including indicating lamp LED type for each phase, incl in built industiral type locking arrangement, front operated and back openable incl necessry arrangement for fixing with suitable clamps, nuts & bolts etc. The panel pre wired with PVC insulated copper conductor danger notice board, feeders marked, and testing & commissioning, complete consisting of the following :-
Supply and Fixing Solar LED light fitting 24 watt with high efficiency All-in-One Solar street light Mono Crystel, Lithium Ferro Phosphate battery with in built BMS technology, MPPT Soler Charge controller and aluminium extruded body with PIR motion sensor automatically control the dimming and brightness of light, battery capacity 30AH , IP65, temp 5700K complete all as diricted.
M&L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI strip 32x6mm by means of bolts. nuts, check nuts and washers etc including protection pipe 15mm dia up to 7.5m length, provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts, bolts, earthing shall be done all as per shown electrical plate No 5 of SSR part 1 Including neccessary excavation in disintergratedand hard soil and 20mm dia GI pipe with funel for watering PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr -in -Charge.
Supply, installation testing & commissioning of waterless and maintenance free earthing with earth (grounding) electrodes and PCC pit with cover. (a) Earth Electrode: 17.2 mm dia copper bonded MS rod shall be in-situ cast in electrically conductive concrete earth enhancing material mixed with cement. Size of embedding of electrically conductive concrete earth enhancing material shall be 85 mm dia. The electrode of 3000mm should be able to withstand a fault current upto 35kA (Peak) for 1 second duly tested from recognized National Test laboratories like CPRI, ERDA, ERTL, MSME etc (not more than 18 months old). The ratio of mixing of conductive concrete to cement should be 3:1. Other hardware like nut, bolts and washers should be of stainless steel.
m/s bansal construction
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .