| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LQualified 18 R N MUKHERJEE ROAD KOLKATA KOLKATA WEST BENGAL 700001 UDYAM WB 10 0021525 19ADOPD5836A1ZN R M MII STATUS AS NOT VERIFIED | KOLKATA | WEST BENGAL | 700001 | ₹2.4 L | L1 | Qualified MSE, MII, Category: General |
| 2 | L2₹2.7 LQualified 89 SHREE DWARKESH INDUSTRIAL SOCIETY UDHNA MAGDALLAH ROAD SURAT 395007 SURAT SURAT GUJARAT 395007 UDYAM GJ 22 0026807 24CBBPK9314H1ZT R M MII STATUS AS VERIFIED | SURAT | GUJARAT | 395007 | ₹2.7 L | L2 | Qualified MSE, MII, Category: General |
| 3 | L3₹2.8 LQualified 5 GANESH BHAVAN SV LANE 3RD CROSS CHICKPET CHICKPET BANGALORE KARNATAKA 560053 UDYAM KR 03 0037648 | BENGALURU URBAN | KARNATAKA | 560053 | ₹2.8 L | L3 | Qualified MSE, MII, Category: OBC |
| 4 | L4₹2.9 LQualified 405 2 SYDENHAMS ROAD APPARAO GARDEN CHOOLAI CHENNAI TAMIL NADU 600112 UDYAM TN 02 0023454 | 600112 | ₹2.9 L | L4 | Qualified MSE, MII, Category: General |
| 5 | L5₹3.2 LQualified 0 VILLAGE DHOOMANPURA GWALIOR ROAD NEAR AVANTI BAI SMARAK ETAWAH UTTAR PRADESH 206001 UDYAM UP 23 0009245 09AEBPA2778J3ZE R M | ETAWAH | UTTAR PRADESH | 206001 | ₹3.2 L | L5 | Qualified MSE, MII, Category: OBC |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
5 Jan 2026, 4:00 pmClosed
MPCBs AND MCCBs
8764548
GEM/2025/B/7045860
Two Packet Bid
MPCB RATING 45-63 AMPS 50KA,MCCB TRIPPLE POLE KF 600 K 400 AMPS,MPCB RATING 28-40 AMPS 50KA,MPCB RA
60 days
Karnataka; Shivamogga
Total value wise evaluation
BOQ
Exempted
5 Jan 2026
26 Dec 2025
5 Jan 2026
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | MPCB RATING 45-63 AMPS 50KA | MPCB RATING 45-63 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS IEC-60947-4 Suitable for motor power rating- 30KW Auxiliary contacts-1 NO plus 1 NC Breaking capacity Ics is equal to 25KA or above Icu is equal to 50KA at 400 OR 415V AC Trip Mechanism- Thermal plus Magnetic Note- 1- Shall furnish make and part number of the offered item along with offer the same offered make shall be supplied in case of PO placed 2- Guarantee or Warranty against manufacturing defects for a period of 12 months from date of supply is required GC or WC should be furnished with supply In case of failure of material during the warranty period party has to replace the faulty material at VISL without any financial implication to SAIL-VISL Bhadravathi 3- Test Certificate shall be furnished along with material supply | 10 | Nos | Pradeep C 577301,Visvesvarya Ironand Steel Plant Bhadravathi | 60 |
| 2 | MCCB TRIPPLE POLE KF 600 K 400 AMPS | MCCB TRIPPLE POLE KF 600 K 400 AMPS Supply of 3 Pole Moulded Case Circuit Breakers (MCCB) as per the specifications given below- Rated Capacity - 400 Amps Breaking Capacity Ics is equal to 100 percent Icu is equal to 25 KA at 415 V AC Trip Unit - Termo Magnetic with Shor Circuit protection Adjustable Over Load protection Note- 1- Shall furnish make and part number of the offered item along with offer the same offered make shall be supplied in case of PO placed 2- Guarantee or Warranty against manufacturing defects for a period of 12 months from date of supply is required GC or WC should be furnished with supply In case of failure of material during the warranty period party has to replace the faulty material at VISL without any financial implication to SAIL-VISL Bhadravathi 3- Test Certificate shall be furnished along with material supply | 4 | Nos | Pradeep C 577301,Visvesvarya Ironand Steel Plant Bhadravathi | 60 |
| 3 | MPCB RATING 28-40 AMPS 50KA | MPCB RATING 28-40 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Suitable for motor power rating- 22KW Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics is equal to 25KA or above Icu is equal to 50KA at 400 or 415V AC Trip Mechanism- Thermal plus Magnetic Note- 1- Shall furnish make and part number of the offered item along with offer the same offered make shall be supplied in case of PO placed 2- Guarantee or Warranty against manufacturing defects for a period of 12 months from date of supply is required GC or WC should be furnished with supply In case of failure of material during the warranty period party has to replace the faulty material at VISL without any financial implication to SAIL-VISL Bhadravathi 3- Test Certificate shall be furnished along with material supply | 10 | Nos | Pradeep C 577301,Visvesvarya Ironand Steel Plant Bhadravathi | 60 |
| 4 | MPCB RATING 25-32 AMPS 50KA | MPCB RATING 25-32 AMPS 50KA 3-Pole motor protection circuit breaker with rotary control handle suitable for type-2 co-ordination conforming to IS or IEC- 60947-4 Suitable for motor power rating- 20 KW Auxiliary contacts- 1 NO plus 1 NC Breaking capacity Ics is equal to 25KA or above Icu is equal to 50KA at 400 or 415V AC Trip Mechanism- Thermal plus Magnetic Note- 1- Shall furnish make and part number of the offered item along with offer the same offered make shall be supplied in case of PO placed 2- Guarantee or Warranty against manufacturing defects for a period of 12 months from date of supply is required GC or WC should be furnished with supply In case of failure of material during the warranty period party has to replace the faulty material at VISL without any financial implication to SAIL-VISL Bhadravathi 3- Test Certificate shall be furnished along with material supply | 10 | Nos | Pradeep C 577301,Visvesvarya Ironand Steel Plant Bhadravathi | 60 |
| 5 | 3-POLE MOULDED CASE CIRCUIT BREAKER 250A | 3-POLE MOULDED CASE CIRCUIT BREAKER 250A Supply of 3 Pole Moulded Case Circuit Breakers-MCCB as per the specifications given below- Rated Capacity - 250A Breaking Capacity Ics is equal to 100 percent Icu is equal to 25 KA at 415 V AC Trip Unit- Thermo Magnetic with Short Circuit protection Adjustable Over Load protection Note- 1- Shall furnish make and part number of the offered item along with offer the same offered make shall be supplied in case of PO placed 2- Guarantee or Warranty against manufacturing defects for a period of 12 months from date of supply is required GC or WC should be furnished with supply In case of failure of material during the warranty period party has to replace the faulty material at VISL without any financial implication to SAIL-VISL Bhadravathi 3- Test Certificate shall be furnished along with material supply | 5 | Nos | Pradeep C 577301,Visvesvarya Ironand Steel Plant Bhadravathi | 60 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_8764548.pdf
GEM_BID
boq_mpcbs___mccbs_2025-12-26-14-55-21_0c88b0892bb6717a97c3e974229cb6b9.pdf
BOQ
boq_-_mpcbs_and_mccbs_05_items_2025-12-26-14-55-21_1147eced748cd31d65932552bf02ddb2.csv
BOQ
BOQ_DOC_c3e31084-b4a0-41a4-b5791766741655662_MM-Purchase.pdf
BOQ
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid