| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAccepted-AOC GOKUL APARTMENTS BLOCK C SHIVMANDIR ROAD PUNJABI PARA SILIGURI 734 401 WEST BENGAL | SILIGURI | WEST BENGAL | 734401 | ₹2.1 Cr Quoted ₹2.2 Cr | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND BEING L1 BIDDER |
| 2 | L2₹2.2 Cr+₹49,428.77 (0.23%)Rejected-Finance 57 7 MEGHNAD SAHA SARANI PRADHAN NAGAR SILIGURI 734 403 DIST DARJEELING | SILIGURI | DARJEELING | WEST BENGAL | 734403 | ₹2.2 Cr+₹49,428.77 (0.23%) | L2 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
| 3 | L3₹2.3 Cr+₹11.2 L (5.22%)Rejected-Finance BINDA JAYANTI BUILDING 31 SEVOKE ROAD SILIGURI PIN 734001 DIST DARJEELING | SILIGURI | DARJEELING | WEST BENGAL | 734001 | ₹2.3 Cr+₹11.2 L (5.22%) | L3 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
| 4 | L4₹2.5 Cr+₹36.8 L (17.1%)Rejected-Finance | ₹2.5 Cr+₹36.8 L (17.1%) | L4 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
| 5 | L5₹2.6 Cr+₹43.0 L (20.0%)Rejected-Finance | ₹2.6 Cr+₹43.0 L (20.0%) | L5 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
Tender Value
₹2.6 Cr
EMD Value
₹3.3 L
Closing Date
18 Sept 2024, 6:00 pmClosed
HQ CWE BINNAGURI
HQ CWE Binnaguri, PO-Binnaguri Cantt, Distt-Jalpaiguri, West Bengal-735232
ADDITION/ ALTERATION TO OTM ACCN AT SEVOKE ROAD MIL STN UNDER GE SEVOKE ROAD
2024_MES_664107_2
8150/E8
Open Tender
Civil Works
Item Rate
365 days
GE SEVOKE ROAD MIL STN
AS PER NIT
8 documents required · 8 mandatory
₹2,000
Yes
GE SEVOKE ROAD
₹3.3 L
Yes
23 Nov 2024
3 Sept 2024
19 Sept 2024
3 Sept 2024
18 Sept 2024
11 Sept 2024
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as per specified and as directed by Engineer-in-charge.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as per specified and as directed by Engineer-in-charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as per specified and as directed by Engineer-in-charge.
Taking down of steel windows/ventilators glazed and wire gauged including grill of any size, complete all as per specified and as directed by Engineer-in-charge.
S&F coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles, complete all as per specified and as directed by Engineer-in-charge.
M&L for coloured glazed ceramic tiles 350x 250x 7 mm/ 450X 350X 7mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of wall mixture CP cast copper alloy for 15 mm bore pipe with L- bend for overhead shower, complete all as specified and as directed by Engineer-in-charge.
M&L for 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed by Engineer-in-charge.
M&L for 10mm thick rendering in cm(1:4) on fair faces of brick work or concrete surfaces as backing coat of dado/skirting etc., complete all as specified and as directed by Engineer-in-charge.
Dismantling of stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, approaches, dado/Partitions etc, complete all as per specified and as directed by Engineer-in-charge.
M&L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite stone including griding & polishing with 20 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
M&L for Machine cut Kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over 20 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
M&L for Machine cut Kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over 10 mm thick screed bed or bedding layer of cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each and removing from site, complete all as specified and as directed by Engineer-in-charge.
Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each and removing from site, complete all as specified and as directed by Engineer-in-charge.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each, complete all as per specified and as directed by Engineer-in-charge.
S&F of Pressed steel frames of size 165x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as per specified and as directed by Engineer-in-charge.
S&F of Pressed steel frames of size 105x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as per specified and as directed by Engineer-in-charge.
S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffener and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life), complete all as per specified and as directed by Engineer-in-charge.
Supply and fixing factory made solid panel factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core supplying & fixing in frame at site as per specification & drawing complete all as per specified and as directed by Engineer-in-charge. With Particle Board Core
S&F of 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed by Engineer-in-charge.
M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as per specified and as directed by Engineer-in-charge.
S&F powder coated aluminium (Minium thickness of powder coating 50 micron) three track sliding windows incl frame, shutters of windows & ventilator including providing and fixing 5.00 mm thick glass pane, roller , handle , locking arrangement, neoprene gasket etc , CP brass/stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed by Engineer-in-charge.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and as directed by Engineer-in-charge.
S&F of 4 mm thick sheet glass of ordinary quality in squares not exc. 0.5 sqm in each pane glazing with oil putty complete all as per specified and as directed by Engineer-in-charge.
S&F of 4 mm thick sheet glass of ordinary quality in squares exc. 0.5 sqm in each pane glazing with oil putty complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of steel ventilator with top hung shutter including hinges, steel peg stay and making good to match as per existing surface etc., complete all as per specified and as directed by Engineer-in-charge.
M&L 35 mm thick second class hardwood glazed and skeleton shutter open rebated and prepared to receive glass, gauge etc (without sash bar) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of member (Bottom 250mm, stiles 100mm, top 120mm & lock rail 160mm wide) as specified in SSR part I section & clause 8.24 (a) complete all as specified and as directed by Engineer-in-charge.
S&F of Stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as per specified and as directed by Engineer-in-charge.
S&F of 200 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F of 300 mm long mild aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as per specified and as directed by Engineer-in-charge.
S&F of 100 mm butt hinges, heavy weight, cold rolled mild steel and fixed complete all as per specified and as directed by Engineer-in-charge.
S&F of 150 mm long aluminium handles, cast type, anodised, complete all as per specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated or semi-corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
S&F of Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation board/Slabs/blankets of any thickness including cover fillets, complete all as specified and as directed by Engineer-in-charge.
S & F of Powder coated snap grid of size of grid 605x605 frame work or false ceiling including hangers 6 mm dia G.I( upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleate made out of G.I Flat 40X 3 mm size 60 mm long and expansion fasteners 12.5 mm dia 40 mm long, complete all as specified and as directed by Engineer-in-charge.
M&L for 4mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws fixed in ceiling flat or sloping, complete all as per specified and as directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed by Engineer-in-charge.
S&F of MS steel work in tubular trusses including special shaped washers etc., complete using ERW or induction butt welded tubes confirming to IS 1161- 1979 graded St 240, complete all as per specified and as directed by Engineer-in-charge.
S&F of roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Confirming to Fe 410-W (Gde E- 250) quality-A, complete all as per specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick wall of any description, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-in-charge.
M&L for 5 mm thick rendering plastering on fair faces of brick work or concrete surface in cement mortar (1:3) and surface even and fair without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 including, surface even & smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for (10+10) mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm & 10mm) mixed with water proofing compound in top layer 200 ml per beg of cement or as per manufacturer's instructions finishing the surface even and fair without using extra cement complete all as specified and as directed by Engineer-in-charge. (Note: WPC shall be measured and paid separately as supply only under relevant item.)
Supply only Liquid water proofing compound confirming to IS complete all as per specified and as directed by Engineer-in-charge.
Taking up or down 15 mm steel tubing and connections, including cleaning for refixing or removal to store, complete all as per specified and as directed by Engineer-in-charge.
Taking up or down 20 mm steel tubing and connections, including cleaning for refixing or removal to store, complete all as per specified and as directed by Engineer-in-charge.
Taking up or down 25 mm steel tubing and connections, including cleaning for refixing or removal to store, complete all as per specified and as directed by Engineer-in-charge.
Taking up or down 32 mm steel tubing and connections, including cleaning for refixing or removal to store, complete all as per specified and as directed by Engineer-in-charge.
S&F of GI tube 15 mm bore medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-charge.
S&F of GI tube 20 mm bore medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-charge.
S&F of GI tube 25 mm bore medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-charge.
S&F of GI tube 32 mm bore medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-charge.
Dismantling water tanks of capacity exc. 250 and not exc. 500 litres, complete all as per specified and as directed by Engineer-in-charge.
Dismantling water tanks of capacity exc. 500 and not exc. 1000 litres, complete all as per specified and as directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tanks double layered ISI Marked (cylindrical, vertical with closed top) of 500 litres capacity hoisted and fixed in position including connecting up pipes securing access covers etc, complete all as per specified and as directed by Engineer-in-charge.
S&F of rotational moulded PVC water storage tank 1000 litres capacity conforming to IS-12701(1989) cylindrical vertical type multi-layered with closed top including inlet, outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part-I, 2009 etc., complete all as specified and as directed by Engineer-in-charge.
S&F in repair of 20 mm ball valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms/ 20 mm - 210gms/25mm-455gms/ 40mm - 690 gms) and fixed in position complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of Gun-metal 20 mm bore pipe, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as per specified and as directed by Engineer-in-charge.
M&L for welded steel wire fabric of weight n. exc 4 kg per Sqm supplied and fixed complete to wood or steel member, complete all as per specified and as directed by Engineer-in-charge.
Taking down existing un-serviceable waterproofing treatment from roof slab and slab and cleaning the roof slab by wire brush and removing WPT felt beyond the MOD premises etc., complete all as specified and as directed by Engineer-in-charge.
M&L for rendering 10 mm thick in CM (1:4) on fair faces of brick work or concrete surface mixed with water proofing compound as per manufacture instruction etc., complete all as specified and as directed by Engineer-in-charge. Notes : WPC shall be measured and paid separately.
Preparation of surface for application of water proof coating, prime the surface with water including removal of all existing treatment, bituminous membrane, tarfelt, screed concrete etc. from RCC roof slab, complete all as specified and as directed by Engineer-in-charge. Note: Surface to be free from frost, surface laitance and contamination and free from loose aggregate or other sharp protrusions with fairly smooth finish.
Application of waterproofing Coating: Providing and applying a single component High build fibre Reinforced Acrylic Waterproofing render for roofing system to be applied by brush, at three coats at minimum dry film thickness of 1 mm, which should cure by reaction with atmospheric moisture to give a tough elastomeric waterproof membrane. Note: (i) The above treatment will be carried out by authorised applicator of approved firm/ company. (ii) Please refer PS for details.
M&L for applying water proofing treatment to slab area with damp proof ultra, fiber reinforced elastomeric liquid applied water proofing membrane of approved make(Asian/Berger/Dr Fixit) . It is formulated with PU hybrid polymers and reinforcing acrylic fibres. Upon curing, it forms a thick, seamless, durable membrane thus offering ultimate water proofing. First do the self priming of smart care damp proof ultra of approved make after completing all necessary surface preparation, coving using approved smart care repair polymer, water pond test, etc complete as per manufacturers specifications and application methodology. The same coating shall be applied in two coats with 4-6 hrs intervals between the coats. Ensure that the product is applied at least 6 inches inside the drain pipe. The coating shall have a 350%-400%elongation with tensile strength of 2.9 Mpa and must be extended up to 300 mm over the slab area and apply parapet to parapet to envelop the entire building. Effectively bridges cracks up to 2.5 mm at 650 microns and provides surface temperature reduction up to 10 degree C. Complete all as specified and directed as per manufacturers instruction and submit roof water proofing warranty certificate of 6 years from the manufacturer.
Expansion Joint Treatment:- M&L for opening the existing installed system from expansion joint. Rain water pipeline also need to be treated with polymer modified mortar. The existing surfaces shall be cleaned properly so as to free from dirt, oil grease, etc. Apply mixed Thixotropic epoxy adhesive using a serrated spreader. Remove central masking tape immediately and position non reinforced Hypalon membrane with release tape into the high strength repair mortar adhesive. Roll firmly to displace trapped air and to ensure extrusion of Thixotropic epoxy adhesive through the edge perforations. Apply a second layer of epoxy adhesive to the full width of the top surface of membrane. Remove central release film from membrane. Finally remove outer edge masking tapes and feather edge the epoxy adhesive, put an Aluminium strip 3mm thick and 15mm width at the edge of “L” portion to make the membrane in proper shape and puncture from lapping portion, Protect the membrane with Aluminium strip (1.2mm STD) followed by nailing system, complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work or rubble stone masonry including all quoins arches, pillars etc. built in cement mortar and including removal from the site, complete all as specified and as directed by Engineer-in-charge.
M&L for brick work with fly ash old sized Bricks straight or curved on plan in CM 1:4 as in half brick thick walls, complete all as specified and as directed by Engineer-in-charge.
M&L for brick work with fly ash old sized Bricks straight or curved on plan exc 6m mean radius built in Cement mortar 1:6, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of white vitreous China wash basin white flat back size 550x400mm (Oval shape) excluding taps but including 32mm dia chromium plated waste fitting and PVC waste pipe 610 mm long and MS brackets, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of sinks made of stainless steel 0.80mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm etc., complete all as specified and as directed by Engineer-in-charge.
S&F in repair of vitreous china squatting pan "Orissa" pattern size 580x440mm white with integral foot rests(excluding flushing cistern and flush pipe) with 'P' or 'S" trap from or back inlet etc including connection to trap and flushing pipe and provision of lime concrete bedding, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of white vitreous China wash down water closet pan (pedestal pattern) EWC, of size 570 x 460 x 380 mm with ‘P’ or 'S' trap, including fixing bolts, plastic water closet seat and cover, closed pattern with flat bottom, and mild steel chromium plated or aluminium anodised hinging device, making all necessary connections and making good the disturbed surfaces of floor, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of tubular towel rail 20mm dia type brass chromium plated 600mm long between flanges, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of PVC valveless double siphonic action type flushing cistern low level of 10 Litre capacity white with inlet ball valve, float, flushing bend & handle including brackets, suitable for both Indian type water closet & European type water closet including brackets & connection to pipe etc., complete all as specified and as directed by Engineer-in-charge.
S&F in repairs of CP brass overhead shower 80mm dia round shape with and including CP brass shower arm 240mm long with wall flange, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of 15 mm bore Chromium plated bib tap fancy type, cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule complete all as specified and as directed by Engineer-in-charge.
S&F in repair of 15 mm bore Chromium plated two way bib cock fancy type, cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule complete all as specified and as directed by Engineer-in-charge.
S&F in repair of Vitreous China urinals, bowl type, flat back, size of 465 x 355 x 265 mm white (minimum), including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, with grating and union for 32 mm PVC discharge pipe, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of Stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of fancy type 15mm dia bore pillar tap cast copper alloy with capstan heads chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed by Engineer-in-charge.
S&F in repair of PVC connection of 45 cm length including brass nuts, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of PVC (SWR) floor trap, plain with grating 75mm including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) and including water leak proof treatment, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of PVC (SWR) gully trap 125/ 110 mm, setting and jointing with solvent cement etc., complete all as specified and as directed by Engineer-in-charge.
Dismantling of cast iron or reinforced concrete drain pipe up to 100 mm dia, jointed in cement mortar and taking out trenches if required etc., complete all as specified and as directed by Engineer-in-charge.
Taking down PVC rain water pipes (any size or pattern) including all fittings head shoes etc., complete all as specified and as directed by Engineer-in-charge.
S&F in repair of 75 mm dia PVC (SWR) pipes single socketed, in any length, with rubber ring joints laid in trenches or in floors, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of 110 mm dia PVC (SWR) pipes single socketed, in any length, with rubber ring joints laid in trenches or in floors, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of 75 mm dia bore PVC (SWR) bends, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of 75 mm dia bore PVC (SWR) bends with access door, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of 75 mm dia PVC (SWR) branch piece, single (single Y) equal or unequal, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of 110 mm dia PVC (SWR) branch piece, single (single Y) equal or unequal, complete all as specified and as directed by Engineer-in-charge.
Demolition and breaking up including removing salt glazed stoneware pipe 200 mm bore (internal) with concrete bedding and haunching complete including necessary earth work as required complete all as specified and as directed by Engineer-in-charge.
Demolition and breaking up including removing salt glazed stoneware pipe 150 mm bore (internal) with concrete bedding and haunching complete including necessary earth work as required complete all as specified and as directed by Engineer-in-charge.
Demolition and breaking up including removing salt glazed stoneware pipe 100 mm bore (internal) with concrete bedding and haunching complete including necessary earth work as required complete all as specified and as directed by Engineer-in-charge.
S&F of 200 mm internal diameter of double wall corrugated (DWC) high density polyethylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked (with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS: 16098-2013, Part-2 complete all as specified and as directed by Engineer-in-charge.
S&F of 150 mm internal diameter of double wall corrugated (DWC) high density polyethylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked (with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS: 16098-2013, Part-2 complete all as specified and as directed by Engineer-in-charge.
S&F of 100 mm internal diameter of double wall corrugated (DWC) high density polyethylene pipes (HDPE) and stiffness classes-8 (SN-8) with ISI marked (with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS: 16098-2013, Part-2 complete all as specified and as directed by Engineer-in-charge.
Demolition of cement concrete (un-reinforced) of any description & in any position not specifically provided for, complete all as specified and as directed by Engineer-in-charge.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description & in any position not specifically provided for, complete all as specified and as directed by Engineer-in-charge.
M&L for 75 mm thick PCC type C-2, 1:3:6 (using 40 mm graded aggregate) as in flooring, plinth protection Finishing cement concrete surface even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for Reinforced cement concrete M-20 (Nominal Mix) (using 20 mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed by Engineer-in-charge.
Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., complete all as specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality conforming to Fe-410-S or Fe-410-O, complete all as specified and as directed by Engineer-in-charge.
M&L for providing RCC M-20 (Nominal mix) (using 20 mm graded aggregate) for slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed by Engineer-in-charge.
M&L for Reinforced cement concrete M-20 (Nominal Mix) (using 20 mm graded aggregate) as in chajjas complete all as specified and as directed by Engineer-in-charge.
M&L for formwork to chullah hoods, chajjas, weather shades, corbels, water troughs and similar items including edges fair finished surface of concrete flat complete all as specified and as directed by Engineer-in-charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) including edges fair finished surface of concrete flat complete all as specified and as directed by Engineer-in-charge.
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) as in hold fast and filling of pressed steel chowkat etc., complete all as specified and as directed by Engineer-in-charge.
M&L for cement concrete 1:2:4 type, B-1 (using 20 mm graded stone aggregates) as in copings, chajja kerbs, roof padding/ staging of water tank etc. including necessary formwork, weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by Engineer-in-charge.
M&L for 20 mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:3 mixed with integral waterproofing compound as per manufacturer's instructions and finished even and smooth surface without using extra cement as in sunken floor treatment etc. complete all as specified and as directed by Engineer-in-charge. Note : WPC shall measured and paid separately under respective item of this Schedule.
M&L for cement concrete 1:5:10 type E-2 using 20mm graded brick aggregates as in sunken portion of WC etc., complete all as specified and as directed by Engineer-in-charge.
Cutting holes into or through brick/ stone masonry walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregates) as required superficial area exc 150 Sq. cm and not exc 400 Sq. cm etc., complete all as specified and as directed by Engineer-in-charge.
S&F in repair stainless steel decorative curtain rod of 25mm bore with wood finishes including brackets 2 no's funnel caps 2 Nos etc., complete all as specified and as directed by Engineer-in-charge.
M&L for preparing of new plastered surfaces of wall (internal & external) and applying two coats of wall putty including preparation of surface to receive finishes (primer, distemper, paint etc.) complete all as specified and as directed by the Eng-in-Charge and as per the manufacturer's instructions. Note: Preparation of new plastered surface and application of wall putty to be carried out mechanically by authorised applicator and as per the manufacturer's instructions. Please refer Smart Painting clause mentioned in Particular Specification.
M&L for complete removal of existing treatment of wall (internal & external) and applying two coats of wall putty including preparation of surface to receive finishes (primer, distemper, paint etc.) complete all as specified and as directed by the Eng-in-Charge and as per the manufacturer's instructions. Note: Removal of existing treatment and application of wall putty to be carried out mechanically by authorised applicator and as per the manufacturer's instructions. Please refer Smart Painting clause mentioned in Particular Specification.
M&L for applying two coats of Acrylic smooth exterior anti-fungal paint of shade as approved by GE over a coat of primer over finished putty surfaces of wall complete all as specified and as directed by the Eng-in-Charge and as per the manufacturer's instructions. Note: 1. Application of new finishes to be carried out mechanically by authorised applicator and as per the manufacturer's instructions. Please refer Smart Painting clause mentioned in Particular Specification. 2. Application of putty and preparation of surface to receive the paint shall be measured and paid separately under relevant item of this schedule.
M&L for applying two coats acrylic-based distemper of shade as approved by GE over a coat of primer over finished putty surfaces of wall complete all as specified and as directed by the Eng-in-Charge and as per the manufacturer's instructions. Note: 1. Application of new finishes to be carried out mechanically by authorised applicator and as per the manufacturer's instructions. Please refer Smart Painting clause mentioned in Particular Specification. 2. Application of putty and preparation of surface to receive the distemper shall be measured and paid separately under relevant item of this schedule.
M&L for applying two coats of colour washing including preparation of old decorated surface on walls, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge.
M&L for preparing old plastered surface of ceiling and applying two coats of white wash etc., complete all as specified and as directed by Engineer-in-charge.
M&L for preparing of old painted surfaces of wood & wood based surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc., complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old painted surfaces of steel surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed by Engineer-in-charge.
Excavation in trenches n. exc 1.5m wide and n. exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Excavation in trenches exc 1.5 Mtr wide and not exc 3.0 Mtr deep soft loose soil type of soil getting out and levelling of bottom surface to required level for cable/stay, complete all as specified and as directed by Engineer- in- charge.
M&L for precast cement concrete (1:1.5:3) type A1 (using 20 mm graded crushed stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4, complete all as specified and as directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) as in coping/ benching for manholes etc., complete all as specified and as directed by Engineer-in-charge.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:3, and surface finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge.
M&L for 20 mm thick rendering on other than fair faces of brick work or concrete surface in cement mortar 1:4, and surface finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge.
M&L for concrete bed to 200 mm dia drain pipes including packing under & haunching against the sides of pipes with concrete after they are laid & tested in PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) complete all as per specified and as directed by Engineer-in-charge.
M&L for concrete bed to 150 mm dia drain pipes including packing under & haunching against the sides of pipes with concrete after they are laid & tested in PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) complete all as per specified and as directed by Engineer-in-charge.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for pipe of internal dia. 150mm, complete all as specified and as directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge.
Taking down carefully old unserviceable copper/ aluminium point wiring (light, exhaust fan, socket or power) complete incl fittings such as switches, ceiling roses, pendants, regulators, bells, sockets, tube light fittings etc., and making good disturbed surface of walls & floors etc., complete all as specified and as directed by Engineer-in-charge.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store, complete all as specified and as directed by Engineer-in-charge.
M&L for concealed point wiring with two single core PVC insulated, unsheathed, multistranded copper conductor FRLS of size 1.5 Sq. mm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 Sq. mm green in colour as earth lead in and including PVC rigid conduit (medium grade), MS sunken box, bakelite cover with all fittings & accessories for mounting fittings switch, sockets, fan regulators etc. for one light / fan/bell point, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 143 above but for one Bell point controlled by one switch, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 143 above but for socket outlet 5/6 AMPs point on same board, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 143 above but for socket outlet 5/6 AMPs point on independent board, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 143 above but for wiring with single core, multistranded copper conductor of size 2.5 sqmm for 15/16 AMPs socket out let point on independent board, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 143 above but for One light point controlled by two 2 - way switches, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch socket 2 in 1, 3 pin, 5/6 Amp flush type universal, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch socket combination 2 in 1, 6 pin, 5/6 Amp flush type universal, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch Socket Combination 5 in 1, 3 pin, , 6 and 16 amp flush type universal, 240 volts, complete all as specified and as directed by Engineer-in-charge.
S&F of Bell push, flush type, 5 Amp 240 volts, complete all as specified and as directed by Engineer-in-charge.
S&F of Buzzer, Ding Dong AC 230 volts, single pole, complete all as specified and as directed by Engineer-in-charge.
S&F of switch piano flush type, 6/5 Amps 240 volts single pole one way, complete all as specified and as directed by Engineer-in-charge.
S&F of switch piano flush type, 16/15 Amps 240 volts single pole two way, complete all as specified and as directed by Engineer-in-charge.
S&F of ceiling rose surface PVC three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-charge.
S&F of exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed by Engineer-in-charge.
S&F of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, complete all as specified and as directed by Engineer-in-charge.
S&F of wall fan AC, single phase, 230/240 V of sweep 400 mm fixing on wall and making good disturbed surfaces with all connecting arrangement, complete all as specified and as directed by Engineer-in-charge.
M&L for sub main wiring two run of size 6 sqmm PVC insulated, ISI marked, FRLSH unsheathed, electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with 6.0 sqmm PVC insulated stranded copper conductor earth wire in PVC conduit of suitable size (two run of 6 sqmm cable and one of 6.0 sqmm wire and one run of PVC conduit will be measured as one unit)including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge.
Supply and fix of fan regulator electronic type, rotary step (speed regulation in 5 steps), SP 240 Volt, suitable for ceiling fans complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) with remote controlled complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc., complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc., complete all as specified and as directed by Engineer-in-charge.
S&F in repair of LED tube light fittings1 x 20 Watt, 220 V, AC decorative box type with driver holder including LED tube rod connecting up with three core flexible copper conductor cable from ceiling rose to tube light fitting complete all as specified and as directed by Engineer-in-charge.
S&F in repair of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-charge.
Supply and fix of sheet metal enclosure powder painted for MCB SPN 12 way double door DB, 240 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching with the existing including taking down old unserviceable complete all as specified and as directed by Engineer-in-charge.
Supply and fix of sheet metal enclosure powder painted for MCB SPN 4 way double door DB, 240 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching with the existing including taking down old unserviceable complete all as specified and as directed by Engineer-in-charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning including taking down old unserviceable complete all as specified and as directed by Engineer-in-charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 6 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning including taking down old unserviceable complete all as specified and as directed by Engineer-in-charge.
Supply and fix of sheet metal enclosure powder painted for MCB/ MCCB/ isolator/ RCCB/ RCBO TP & N 4 way double door DB, 415 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching with the existing including taking down old unserviceable complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN/FP 40 to 100 AMP and current carrying capacity in the DB complete with connection testing and commissioning including taking down old unserviceable complete all as specified and as directed by Engineer-in-charge.
M&L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with using galvanised iron 25x4mm strip as earthing lead wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on complete and taking down old unserviceable one, complete all as specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in hard/dense soil, complete all as per specified and as directed by Engineer-in-charge.
Removing excavated Soil materials to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point, complete all as per specified and as directed by Engineer-in-charge.
Supply, fixing & testing of 35 Sqmm, 3.5 Core XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. Note - Earthwork etc. shall be measured and paid separately.
S&F XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories of size 16 Sqmm 2 Core cable including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. Note - Earthwork etc. shall be measured and paid separately.
Supply, laying, jointing & testing of 25 Sqmm, 4 Core XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories such as Aluminium cable lugs, cable gland, nut, bolts, washer etc including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. Note - Earthwork etc. shall be measured and paid separately.
Supply and laying of 63 mm internal diameter of double wall corrugated (DWC) pipe in trenches/ over ground/ along wall with all fitting & jointing complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
B.B.Enterprise (BID ID -3098332)
HARBHAJDAS AGARWAL (BID ID -3096955)
M/s B.K. AGARWAL (BID ID -3093275)
CHAKRABORTY AND SONS (BID ID -3096873)
MAA BHAGWATI ASSOCIATES (BID ID -3099012)
M/S JYOTI SHARMA AND SONS (BID ID -3098795)
VARNI BUILDERS (BID ID -3098715)
B D JAIN and Co (BID ID -3099003)
M/S JANATA CONSTRUCTION (BID ID -3098768)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .