| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for comprehensive maintenance and repairs / rectification of deffects by electrically and technically by checking all indicators, SMPS, mother board, card , electrical connections and replacement of faulty service parts of complete with fire alarm system of any make and model installed in CSDO , AFRO, AFCAO, DIT, AFCME all as specified and as directed.
NOTE FOR ITEM NO 1 ABOVE :- ALL DEFECTIVE PART WHICH ARE REQUIRED TO REPLACE SHALL BE MEASURED AND PAID SEPERATELY UNDER RESPECTIVE ITEMS
(a) FIRE ALARM CONTROL PANEL : The functions of controls panel and indicating equipment will be checked by the operation of a trigger device in each zone. All fault indicator and their circuits will be checked by stimulation of fault conditions of any type fie alarm panel.
(b) HEAT DETECTOR : Heat detectors will be tested by aim a heat lamp, blow-dryer, or heat gun at the heat detector. The detector alarms should sound within three or four seconds after apply the heat source.
(c) SMOKE DETECTOR : Smoke detector will be cleaned periodically so as to remove dust or dirt that accumulates on them due to local ambient conditions at least each detector is cleaned once in month. Smoke detectors will be tested by apply a small spray of smoke detector test aerosol. The detector alarms should sound within three or four seconds after apply the heat source.
(d) MANUAL CALL POINT HOOTERS : All manual call points will be operated once a monthly by removing glass or by actual breaking of glass so as to ensure that system is capable of operation under alarm conditions and all hooters give proper sound
(e) RESPONSE INDICATORS : All detectors which are placed in side a cabin of room will be tested by initiating the particular detector so as to ensure the proper working of response indicator
(f) WIRING & CABLES : A visual inspection will be made so that structure or occupancy changes does not damage cables and sitting of trigger devices (manual call points smoke detector and heat detector.
(g) MONTHLY LOG SHEET WILL BE MAINTAINED FOR MONTHLY INSPECTION AND TESTING : Monthly inspection and testing will be done in the monthly maintained log sheet. Log sheet will be produced to the Engineer-in-charge duly complted on Ist day of every month.
NOTE :- (a) Replacement of parts will be measured and paid seperately.
(b) If service is not carried out by the contractor on due date Rs 1000.00 per day for each service recovery will be made.
(c) Contractor will provide One Technician and One helper from 0900 to 1700 hrs in all working days for day to day services.
(d) The maint shall be carried out through manufacturer representative or his authorised rep. (e) Any other work such as updation of location in fire alarm panel or at location deemed included in quoted rate. | 11 | Per Month | - | - |
| 2 | Supply, installation, testing and commissioning in replacement of Intelligent Analog Addressable MuliticriteriaType Detector Complete with Dual LED, Hard Addressable Having rotary decade Address swicthes from 01-99, complete with Mounting Base Complete as required Conforming to BS 5839 Standards and Duly Approved by EN54/LPCB//UL complete all as specified and directed. Make: honeywell and equivalent make as approved by GE | 320 | Each | - | - |
| 3 | Supply, installation, testing and commissioning in replacement of fault isolator with base with termination preferably after every 20–30 devices and shall be able to isolate electrical short circuit in the wiring etc. as required complete all as specified and directed. Make: honeywell and equivalent make as approved by GE | 40 | Each | - | - |
| 4 | Supply, installation, testing and commissioning in replacement of Intelligent Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully complaint to EN54 having Rotary Decade Swicthes for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directe. Make: honeywell and equivalent make as approved by GE | 18 | Each | - | - |
| 5 | Supply, installation, testing and commissioning in replacement of Response Indicators for getting fire indications of detectors installed above false ceiling area interconnecting to loop cable complete all as specified and directed . Make: honeywell and equivalent make as approved by GE | 165 | Each | - | - |
| 6 | Supply, installation, testing and commissioning in replacement of Addressable Type Loop Powered Hooter Cum Strobe complete with Mounting Base as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed. Make: honeywell and equivalent make as approved by GE | 10 | Each | - | - |
| 7 | Supply & fix in replacement of battery maintenance free 12 volt 24 AH complete all as specified and directed. | 6 | Each | - | - |
| 8 | Supplying, drawing, connecting, testing & commissioning in replacement of 2 core, 1.5 sq. mm. stranded copper conductor, pvc insulated PVC sheathed,aluminium myler tape shielded FRLS wire in existing conduit complete all as specified and directed .(For Fire Detection & Alarm System) | 251 | RM | - | - |
| 9 | Supply and laying in position in replacement of the following sizes of 25/ 20mm Dia PVC. conduits including providing all accessories complete all as specified and directed. (For Fire Detection) | 240 | RM | - | - |
| 10 | S & F in replacement of Loop driver card suitable for fire alarm/detection control panel complete all as specified and directed. | 3 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
Tender56.pdf
Tender Documents • 1.25 MB
BOQ_885493.xls
BOQ • 1.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .