Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC VPO KHERI SANWAL TEHSIL AND DISTT CHARKHI DADRI 127306 | CHARKI DADRI | HARYANA | 127306 | ₹1.5 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹1.5 Cr+₹68,436 (0.46%)Rejected-AOC C141 SUN CITY SECTOR 35 ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹1.5 Cr+₹68,436 (0.46%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹1.5 Cr+₹92,607 (0.63%)Rejected-AOC | ₹1.5 Cr+₹92,607 (0.63%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹1.5 Cr+₹3.8 L (2.60%)Rejected-AOC H NO 1100 SECTOR 3 124001 | ROHTAK | HARYANA | 124001 | ₹1.5 Cr+₹3.8 L (2.60%) | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹2.7 L
Closing Date
18 Mar 2021, 4:00 pmClosed
BP Sharma
PHED No 2 Rohtak
Construction of S S tank High level tank Filter beds Clear water tank Pump chamber boundary wall CC roads laying the internal distribution lines Providing Household tap connections Supply erection testing commissioning of Raw water
2021_HRY_161938_1
Water supply scheme Gugaheri under JJM
Open Tender
Civil Works
Works
450 days
Rohtak
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹2.7 L
31 Mar 2021
4 Mar 2021
18 Mar 2021
4 Mar 2021
18 Mar 2021
4 Mar 2021
Amount
RAW WATER PUMPING MACHINERY Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame WATER WORKS GUGAHERI600 LPM X 12.5 M. Head CLEAR WATER PUMPING MACHINERYSupply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame
WATER WORKS GUGAHERI 600 LPM X 45 M. Head
PANEL BOARDS FOR MOTORS Supply, erection, testing & commissioning of wall mounted electrical L.T. Panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400 mm deep having follwing items For 2 no Pumping Sets of 600 LPM x 12.5 m Head a) Main switch 63 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 600 LPM x 12.5 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No.h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
For 2 no Pumping Sets of 600 LPM x 45 m Head a) Main switch 63 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 600 LPM x 45 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
Supply, erection, testing & commissioning of IS marked copper wire for various motors with underground system in PVC and flexible pipes copper wire 3 core complete in all respevts with accessories like thimble etc. 10mm2 3core
25mm2 3core
Specials for Pumping Machinery & H/W Supply, fixing & testing of Mechanical Joints PN 1.6 alongwith ruber gaskit & galvanized nuts / bolts complete in all respect.100 mm i/d (For Pumping machinery)
200 mm i/d (For H/W pipe line)
Supply, erection, fixing & testing of DI Double flanged pipe complete with all jointing materials 100 mm i/d
Supply erection testing and commissioning of exhaust fans each having a capacity of 45 cubic meters per minutes, complete in all respect.
Supply erection & testing of Ceiling fan of size 48" i/d (1200 mm) of reputed ISI make complete in all respect.
Providing and fixing of insulated Rubber matting suitable for HKV installation 1 meter x 2 meter x 12 mm as per specification.
Providing & fixing suitable size floating along with swivel bend as per required specifications approved by Engineer-in-Charge 250 mm i/d
Supply erection testing of reputed make LED light 100 wats with fittings and accessories complete in all repects.
Supply erection testing and commissioning of Flow Meter (KRONE Make) with digital display of 150 mm i/d complete in all respect.
Design, Supply & Erection of 1 No. DG Sets of required KVA as mentioned below suitable capacity on higher side capacity with Acoustic Canopy, AMF Panel and Copper Earthing of suitable rate with change over switch & synchronizing panel complete as per DNIT including operation & Maintenance of 5 Years. 25 KVA
Providing & fixing in position GI elbow ISI marked complete in all respect 15 mm i/d
Providing & fixing in position GI Nipple ISI marked complete in all respect15mm x150mm /100 mm
Operation & Maintenance Operation & maintenance for the complete scope of work mentioned in the DNIT (Disinfection material will be supplied by the PHED) as per schedule-IV during Defect liability period of 12 months after trial run period of 3 months & 5 years thereafter. (Will be charged to A/mtc estimate)."Defect liability period
Operation & maintenance during 1st year
Operation and maintenance during 2nd year
Operation and maintenance during 3rd year
Operation and maintenance during 4th year
Operation and maintenance during 5th year
Bidder Name
Amount
Lalit Kumar(GSTN-06ALGPB5309Q1ZY)
Kulbir Singh Contractor(GSTN-06ATZPS6352H1ZW)
Amarjeet Sindhu(GSTN-NA)
SANJAY KUMAR CONT(GSTN-NA)
Lalit Kumar
Kulbir Singh Contractor
Amarjeet Sindhu
Kulbir Singh Contractor
Lalit Kumar
SANJAY KUMAR CONT
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .