Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹46.6 L+₹1.4 L (3.03%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹46.8 L+₹1.6 L (3.48%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹47.1 L+₹1.9 L (4.16%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹47.3 L+₹2.0 L (4.39%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹48.0 L
EMD Value
₹95,900
Closing Date
13 Apr 2023, 6:00 pmClosed
GE NORTH PUNE
Garrison Engineer North General Cariappa Marg Camp Pune 411001
GE (N) P/TOKEN- 55 OF 2022-2023 PROVN OF THREE PHASE ELECTRIC SUPPLY AND AREA SECURITY AND GARDEN LIGHTS , UPGRADATION OF STREET LIGHT SYSTEM TO ENERGY SAVING STREET LIGHT AND RW, MW WKS IN THE AREA OF AGE E/M (N) UNDER GE (N) PUNE
2022_MES_562158_3
GE (N) P/TOKEN- 55 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NORTH PUNE
Refer tender documents.
8 documents required · 8 mandatory
₹500
Yes
₹95,900
Yes
22 Jun 2023
18 Mar 2023
20 Apr 2023
18 Mar 2023
13 Apr 2023
1 Apr 2023
20 Mar 2023 - 28 Mar 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed
Supply and laying 50mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propagating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
Supply and laying 80mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propagating properties plete with fittings for cable protection complete all as specified and as directed.
M & L for PCC (1:3:6) type C2(using 40 mm graded stone aggregate ) as in foundation of poles and similar works, filling mass concrete complete all as specified and as directed.
Supply, lay, joint, test and commissioning of LT under ground cable 1100 volt grade , XLPE insulated and PVC sheathed heavy duty armoured with aluminium conductor , IS 7098-I Marked, Laid in trenches/ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe including cable glands, lugs jointing material etc complete all as specified and directed. cable of the size. 10 Sq mm 4 Core
- Ditto - all as per item No 07 above but of size 16 Sq mm 4 Core
- Ditto - all as per item No 07 above but of size 70 Sq mm 3.5 Core
Supply and errection in true vertical position Hot-Dip galvanised Octagonal poles for street lighting in single section of 6 Mtr height, top- 70mm Dia, Bottom - 130mm Dia and 3mm thickness sheet. base plate of minimum dimenssion 200mm x 200mm x 12mm, including foundation bolt (4 Nos with 3 Nos of nuts and washers in each), with decorative single arm bracket for mounting the light fitting 1000mm long, bent at an angle of 120 Degree, with necessary holding brackets, hold fasts, etc bakelite sheet with one 6A sp mcb and 16 Sqmm stud type connector (4 Nos) inside the pole at door opening for cable connection, common templates minimum 1 for each 15 poles complete all as specified and as directed.Foundation for cement concrete should be as per pole manufacturer. NOTE : Rates for Earthwork, Cement concrete for foundation, etc are deemed to be in quoted rates
Supply and fixing Inverter LED Street light fiting with 4 hrs back up, street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. make Halonix Cat Part No LED SL 90W HLSLD-ML04 - 90- CWL- INV - RTC- R / or equivalant in Bajaj, Philips, Jaquar
S & F in replacement LED street light fitting 60 Watt 230V energy efficient & environment friendly type. The fitting should have powder coated, pressure die cast Aluminium housing and heat resistant toughened glass with frame having better optics for uniform distribution complete all as per Make JAQUAR LSRTO1S060XC / Bajaj ENXT P 72L WH CR PC SD / HAVELLS ENDURAOMNIPLUS SL60WLED757SASYTOPC
S & F decorative LED bollard with aluminum die casting, suitable for and including 8 watts LED , elecrical connections with adequate size complete all as specified and as directed. Make: Jaquar Monaco Cat part No 340.44.NGG , equavalent in Philips Cat no BCP400 LED09 D CW PSU GR S1, Havells Cat no BAMBOO BL8WLED840SSYMTOPCM
Supply and errection in true vertical position for factory made steel tubular LT column for LED Column/pathway lighting 20 Watt having pressure die cast AL housing with specially designed optics provide uniform light distributuion fixed on company made type steel tubular LT pole fixed in ground all as specified and directed . Make :Monaco item code 340.PE8.NGG of JAQUAR , Wipro catpart Urbano Pathway LP06-351-XXX-57-XX OR Equivalant in Havells, PHILIPS
S & F for LED post top lantern fitting made of cast aluminium spigot housing with decarative diffuser complete with all accessories fixed on GI pipe 50 mm dia complete all as specified and directed. Jaquar Monaco Cat part No 340.33.NGG , Philips Cat no BGP161 LED2300/WW PSU 220-240V 7043 IN, Bajaj Cat no BRIL 40W LED WW
S&F for neon LED Rope light of warm white/green colour LED's. Rope light should be shockproof, Waterproof suitable for Outdoor purpose, Flexible Strip with and including suitable Adapter for Decoration purpose. Make Havells/Phillips/Bajaj
S & F Bush and spike LED light multi colour with die cast aluminium housing with transparent glass diffuser fitting of capacity 8 watts and IP 66 protection icomplete all as specified and as directed Make : JAQUAR ,Bajaj, Philips, Wipro, Havells.
S & F decorative hanging light of warm white colour with die cast aluminium housing capacity 8 watts and IP 66 protection icomplete all as specified and as directed Make : JAQUAR ,Bajaj, Philips, Wipro, Havells.
Supply and fixing LED flood light 200 watt 230 VAC of green colour LED light, outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion complete with driver and lamp.resistant Make: Havells/Philips/Wipro
Supply and fix Junction box IP 65 ready made type having Aluminium bus bar of capacity 60 Amps, box size 155 x 210 x 92 mm with connector and including bus bar (3 phase + 1 Neutral) 60 Amps and MCB SP 6 Amps 10 KA 240 volts with necessary connections and entry glands and fixed the box on poles by means of mild steel flat iron 25 mm X 4 mm thick cut to size made to shape and fixed on poles with suitable size of nut, bolts and washers complete all as specified and as directed cat part no: KF 1616 B of hensel
Supply and fixing in bracket for LED street light fitting of any type/wattage made out of 32mm GI tubing light grade made to shape including clamps, nut bolts washers etc and fixed in repairs complete all as directed.
S & F MCCB 4 pole 415 volts 25 KA suitable for fixing on existing panel of PG Road sub stn of capacity 200 Amps (ics = 100% icu) with extended terminals complete all as specified and as directed.
Design, supply, install, test and commissioning of free standing floor mounted, dust and vermin proof LT cubical panel outdoor type, fabricated with 3.15 mm thick CRCA MS Sheet for load bearing members and 2mm thick for doors and covers as per IS - 5039 / 1983 , partially type tested , CPRI approved , with aluminium bus bar of size 300 Amps for phases and half nuetral mounted on insulators MS sheet shall be painted with epoxy powder paint by means of electro static gun after rigorous pre treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces.The panel shall be provided with double stud hinged door, front openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10KA and degree of protection shall be IP 54. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following:
(a) MCCB , 4 pole , 160 Amps , 415 Volt , 3 phase , AC , 50 Hz , with breaking capacity 16KA - 01 No ( Incoming) ics = 100% icu .
(b) MCCB , 4 pole , 63 Amps , 415 Volt , 3 phase , AC , 50 Hz , with breaking capacity 16KA - 02 No ( outing) ics = 100% icu .
(b) MCCB , 32 pole , 20 Amps , 415 Volt , 1 phase , AC , 50 Hz , with breaking capacity 16 KA - 02 No ( outgoing) ics = 100% icu .
(e) Phase Indicator lamp LED type , R.Y.B - 01 Set of Three .
(f) Digital Timer switch for security light ,415V - 01 No .
(g) Power contactor 4 Pole 32 Amps- 01 No .
S&F for factory made street light control panel, with and including all accessories such as control switch, contactor, automatic control relay, pre-wired etc. fixed on fabricated angle iron channel of suitable size and grouting on floor, Timelite-32 Amps, 3 Pole 230/415 volts-Astronomical Time switch (suitable for Pune area), Make -Indo-Asian Cat No.TLO32ASO or equivalent in Havells, Legrand.
M & L for Trimming the branches of trees not more than 50 mm dia.and upto 5 Mtr distance where touching the street light pole or obstracting the street lights, without damaging the pole. The rates are deemed with & including cleaning the ground area after trimming trees and dump the leafs and branches at the site where directed.
Supply and fixing PVC insulated and sheathed 1100 volt grade copper cable of size 4 sqmm 3 core complete with lugs etc all as specified and as directed
Supply & lay GI tubing light grade in protection of cable at road crossing/canal crossing/hard standing as per site requirement etc of size 80 mm dia complete all as specified and directed
Supply & lay GI tubing light grade silver enamled painted in protection of cable at road crossing/canal crossing/hard standing as per site requirement etc of size 40 mm dia complete all as specified and directed
M&L for Maintenance Free Grounding Solution set earthing comprising of High tensile low carbon steel rod of 3 Mts length & 17.2 mm dia with 250micron ( average ) molecularly bonded copper on the outer surface along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. The earth electrode should finally be housed in a heavy duty ready made type PVC chamber with future access cover. Back-fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Make: JEF Technology or equivalant in True power earthings/Excel fibrotech NOTE :- (a) Rates for Excavation and earthwork in any type of soil/strata, testing on completion, Copper strip 20x3 mm and 40 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. (b)On testing, after completion, if the earth resistance < 5 ohms is not obtained, earthing will be rejuvenated at no extra cost till the desired earth resistance is obtained. c) Test certificate from the OEM has to be produced by the contractor for the material used in earthing
Supply and laying 32mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propagating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
Supply and fix 6 meters Energy Efficient solar Hybrid model pole with Decorative lighting system with aesthetically designed luminaire mounted on 6m high pole with integrated vertical solar PV panel(Warm White). Luminaire should have 50 W with lumen output not less than 6000 lm with efficacy not less than 120lm/watt. Life expectancy of 50000 Hr with 70% lumen maintenance. colour temperature of 4000K with CRI>70. Luminaire should have pressure die cast aluminum housing with minimum IP66 protected with IK08 impact resistance with a working temperature 0 to 35 degree. Luminaire should have factory fitted cable and waterproof connector to terminate in the charge controller.LFP Battery of 12.8V/60Ah rating to be provided within the pole. Battery should be IP68 enclosure with life of 2000 cycles. Battery should have factory fitted leader cable with waterproof connector matching with charge controller. Monocrystalline PV panel 400Wp/23Voc should be integrated into the pole. Cell efficiency of panels should be not less than 16.4%. Waterproof factory fitted connectors should be provided for termination of PV cable into charge controller. The column should be of total 6m length. Material of construction for pole and pole base should be galvanized MS with two suitable 2m long aluminum extrusion arrangement on the upper half to hold the PV panel.
The pole and aluminum extrusion should be painted aesthetically. Charge controller should be housed inside the pole hatch and should have IP67 waterproof connectors to terminate cables from luminaire, PV and battery. Charge controller should be MPPT type with efficiencies > 90%. Charge controller should have a default dimming profile for 15W output which can be and should have protection against Battery Reverse Polarity, Panel Reverse Polarity, Panel Reverse Current, Surge Protection at PV input up to 1kV of Differential Mode, Battery Over Voltage, Load short circuit, Load Disconnect/Over Voltage, Maximum Battery charging current, Panel over voltage protection. PV module to be placed vertically on all sides of pole to get maximum sunlight for charging battery bank, With Civil installation of Suitable Foundation with anchor plate 300X300 PCD with M20 X 700 J Bolt as per standard. Luminaire should conform to IS10322 test standard specification.Battery should comply with IS 16046:2015. Panel should comply with IS14286, IS61730-1&2. Charge Controller IEC 621 09-1, IEC 62093, IEC 61547, IEC 61347 & EN 50530. Make:- Phillips (Urban Spark), Surya (Urban spot circular) and equivalent in Havells.
Supply, lay, joint, test and commissioning of LT under ground cable 1100 volt grade , XLPE insulated and PVC sheathed heavy duty armoured with aluminium conductor , IS 7098-I Marked, Laid in trenches/ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe including cable glands, lugs jointing material etc complete all as specified and directed. cable of the size. 3.5 core x 95 Sqmm
- Ditto- all as per item no 30 above of the size 3.5 core x 35 Sqmm
Supply and laying 63 mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propagating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
Supply, fixing, testing and commissioning in replacement of LT feeder pillar panel single door floor mounted outdoor type, as per IP-65 grade, made out of MS sheet 3.00 mm and inner compartment 2.00 mm thick of size 540x525x200mm with aluminium bus bar 250 Amps, 4 strip (3 phase) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator with digital type multifunction meter will show voltage, current,frequency, wattage all in one meter panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking with 250 Amps 25 KA MCCB four pole for incomer cable, should have danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands etc and providing fixing arrangements including earthing lead fixing arrangement, complete all as specified and directed. Note :- Installation, testing, commissioning and connecting of incoming and outgoing cable connection LT feeder pillar panel is included in rates quoted.
Supply and lay in trenches /under roads/ crossing or fixed to wall/ pole, GI tubing light grade of size 50mm bore for protection of UG cables complete all as specified and as directed.
S&F MCCB 100 A ,4 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands enclosed in metal box etc complete including testing & commissioning all as specified and as directed.
Supply and fix high capacity Inverter of capcity :- 5.2 KVA (48 volts), digital display, safe for sensitive appliances with Sine wave output, supports a wide battery range, i.e. polarity, battery over charge, deep- discharge etc with 2 year warranty with 4 hrs backup all as specified and as directed. Make: EXIDE SINE WAVE or equivalent in Luminous.
Supply and fix tubular Inverter batteries 12 V, 200 AH, having high performance, made using rugged tubular plates including copper cables to connect with other batteries/ inverter all as specified and as directed. Make :- New Exide- IMTT-2000 or equivalent in Luminous.
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 50 KVA all as specified and as directed.
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with multistranded copper conductor of size 10 Sq. mm nominal area and drawing into PVC non metallic rigid heavy duty PVC conduit and its accessaries ISI marked heavt duty of suitable size including with two runs of PVC insulated 10.0 Sqmm (nominal area) multistranded copper conductor FRLS cable as earth wire and connected from DB to DB/ main board complete all as specified and as directed. Note:- four runs of 10 sqmm cable, two runs of 10 sqmm cable and one run of PVC heavy duty conduit will be measured as one unit.
Supply and Installation, commissioning of Inverter type wall mounting air cooled split type unit air conditioner electric driven single phase indoor unit and outdoor unit with cordless remote control unit and with in built airioniser and plasma filter for better indoor air quality cutting ,brazing and connecting the copper pipe of size 1/2 inch and 1/4 inch size of pipe and making holes as for passing of copper pipes and electric cables and pressure testing with nitrogen and freon gas vacumising the system and charging the Non CFC refrigerent and testing the complete system for smooth functioning of split AC up to satisfactioning, above 3 star rating, confirming to IS-1391 Para II 1992 herimatically sealed air compressor working with Non CFC refrigerent suitable for wall mounting 6000 K cal/ hrs 2 Ton with stand for outdoor unit to fix on wall/ground complete all as specified and directed.
Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type wall mounted and designed for input variation between 170 volts to 250 volts with out put voltage stablized at 230 volts with accuracy of + 2.5% and capacity 5 KVA suitable for AC complete all as specified.
Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
ANAND ENTERPRISES
TULAJA ENTERPRISES
Mahindra Electric Stores
CHAITANYA WINDWELL
Akanksha Enterprises
M/s Asrani and sons
PURVA ELECTRICALS AND ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .