| 1 | L1₹17.5 LAccepted-AOC 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹18.4 L+₹73,800 (4.18%)Rejected-Finance WARD NO 4 NEAR MASZID BHATTAGAON DISTT JHANSI 284001 UTTAR PRADESH | JHANSI | UTTAR PRADESH | 284001 | L2 | Rejected-Finance not become lowest bidder | |
| 3 | L3₹19.6 L+₹2.0 L (11.3%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L3 | Rejected-Finance not become lowest bidder | |
| 4 | L4₹21.0 L+₹3.3 L (18.8%)Rejected-Finance D12 GROTH CENTRE COLONY BIJAULI JHANSI U P | JHANSI | UTTAR PRADESH | 284001 | L4 | Rejected-Finance not become lowest bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Oct 2022, 6:00 pmClosed
Lt Col Deepak Kumar
Garrison Engineer Jhansi
CERTAIN REAPIR AND MAINT WORKS TO HIGH MAST LIGHTS, FLOOD LIGHTS, SECURITY LIGHTS, PAINTING OF POLES, RENEWALS OF EARTHINGS ETC AT JHANSI CANTT UNDER AGE E/M AT GE JHANSI
2022_MES_553726_1
GE/JHA/TOK/47 OF 2022-23
Open Tender
Civil Works
Item Rate
GE Jhansi
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE Jhansi
₹60,000
Yes
3 Dec 2022
22 Sept 2022
21 Oct 2022
22 Sept 2022
19 Oct 2022
6 Oct 2022
Amount
Material and labour for overhauling of existing 16 meters height high mast lighting system by degreasing and cleaning of double drum winch, gear box, wire rope, clamp, bobbin arrangement, power tool motor, mechanical torque limiter, lowering the mast head assembly, degreasing and cleaning the pulley, docking arm etc and applying new grease / lubricating oil for all mechanical moving / rotating parts, checking all the electrical parts such as timer panel, all cable connections in control panel, motor, junction box, flood light fittings & aviation obstruction light fitting etc, rectifying the defects, renewing the defective components etc including testing for proper functioning complete all as specified and directed by Engineer-in-Charge. Note: Replacement of flood light fittings, aviation obstruction light, control cable, steel wire rope , timer panel components & rewinding of motor if required at site shall be measured and paid separately. However, the cost of minor spare parts & lubrication is deemed to be included in the quoted rate.
Supply and fix in replacement of 150/170 Watt LED flood light fitting made up of Pressure die-cast aluminium alloy housing with toughened glass, IP65 protection and impact resistance of IK07 and individual high power LEDs with secondary optics having system lumen efficacy ≥100 lm/W, Inbuilt potted electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Over Voltage protection, Surge Voltage protection & other safety test as per IS 15885 Part-2/Sec 13 and BIS complying including surface mounting using adjustable MS cradle of thickness 5 mm provided with the fixture including taking down existing unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge.
All as per Serial Item No. 2.00 here-in-before but of 100 Watt LED flood light fitting.
Supply and fix in replacement of Integral LED aviation light fitting comprising of aluminium housing with polycarbonate enclosure including taking down existing unserviceable aviation light of any description complete all as specified and directed by Engineer-in-Charge.
Supply and connecting in replacement of PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable 5 core x 4 sqmm, 1100 Volt, conforming to IS 694 including taking down of existing unserviceable copper control cable of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of round strand galvanized steel wire rope conforming to IS:2266/02 of size 8mm dia, 6/36 SW construction including taking down existing unserviceable wire rope of any description complete all as specified and directed.
Supply and fixing in replacement of analog time switch, 3 module size suitable for automatic switching ON & OFF of street lights through 3 pole power contactor including taking down existing unserviceable time switch of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of reversing starter with Forward, OFF and Reverse switch 25A suitable for three phase power tool motor of high mast lighting system including taking down existing unserviceable reversing starter of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of three pole AC power contactor, 32 Amps, 415 volts suitable for street light timer panel including taking down existing unserviceable power contactor of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement MCB, TPN, 40 Amps, 10 KA, 415 V, 50 Hz, AC including taking down existing unserviceable MCB of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement MCB, TPN, 63 Amps, 10 KA, 415 V, 50 Hz, AC including taking down existing unserviceable MCB of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Auto/ Manual with centre off switch suitable for street light timer panel including taking down existing auto / manual switch of any description complete all as specified and directed by Engineer-in-Charge.
Cutting and removing of burnt out winding from electric motor of any make and rewinding with super enameled copper winding wire of existing gauge and number of turns including varnishing, heating etc and testing for satisfactory performance for capacity up to 3.0 HP, 3 Ph, 415 Volts, 50Hz, AC motor complete all as directed by Engineer-in-Charge.
Supply, fixing, installation & testing of All-in-one integrated solar street light with built in 36/40 Watt LED light, Mono Crystalline SPV Panel, Lithium Ferro Phosphate (LiFeP04) battery, MPPT charge Controller and PIR sensor with colour temperature 6000-6500K including taking down existing unserviceable solar street light fitting of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Circular LED Highbay light fitting 150 Watts, Integral product with LED, driver, aluminium heat sink for better thermal management, Polycarbonate high transmitivity lens and 3 core wire out for input power, with IP65 degree of protection, including taking down existing highbay light fitting of any description at any height from workshops / aircraft hangars complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of LED Post top light fitting 45 Watt / 50 Watt, made in die-cast aluminum housing with decorative clear opal acrylic diffuser, IP 65 protection, spun aluminum powder coated canopy, low power Warm White (WW) LEDs connected in series and parallel combination with better heat dissipation arrangement with LED color temperature- 3000K ±300K, Highly efficient constant current electronic driver having operating voltage range from 140-280 Volt AC, provided with high voltage, open and short circuit protection, Voltage surge protection 5KV complete suitable for up to 60mm OD pipe entry with fixing bolts including taking down existing unserviceable post top light of any description complete all as specified and directed by Engineer-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core 4 sq. mm nominal cross section in service connections complete all as specified and as directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core 6 sq. mm nominal cross section in service connections complete all as specified and as directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core 10 sq. mm nominal cross section in service connections complete all as specified and as directed.
Material and labour for preparation of old painted surfaces of HT / LT steel poles and painting with one coat of aluminium paint on all steel surfaces such as poles, channels, angles, clamps, nuts, bolts and washers of any description and Zebra marking on pole with black paint up to one meter height above PCC coping including pasting of radium reflector band / strips (Make: 3M or equivalent) of 5cm wide in Green (02 Nos) & White (01 No.) colour shall be provided at a height of 1.25mtr from coping of pole and writing the pole number in black colour on yellow background at a suitable place on the pole including applying one coat of snow cem on PCC coping of pole complete all as specified and directed by Engineer-in-Charge.
Material and labour for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II
M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II
Excavation in post holes (or similar holes) each not exc 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface complete in any type of soil.
M&L for mild steel work as in replacement of posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets(for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
Supply and fix in replacement of Galvanized Steel Chain Link fencing of mesh size 50mm x 50mm and dia of wire 4.00mm with and including line wires fixed to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed by Engineer-in-Charge.
M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc conforming to Fe.290.Gde-E-165 including taking down existing framed work of any description complete all as specified and directed by Engineer-in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil in the transformer yard complete all as specified and directed by Engineer-in-Charge.
Supply and spread graded coarse aggregate of 63mm nominal size around outdoor transformer and HT 11 KV two/four pole structure complete all as specified and directed.
M&L for Brickwork with sub class ‘B’ bricks on plan built in CM 1:6 complete all as specified and directed.
M&L for rendering 10mm thick cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (with out using extra cement) complete all as directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundations of pole/ stay assembly complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping of pole including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for pruning of tree branches up to 2.0 meter clearance all around HT/LT overhead lines and depositing where directed at a distance not less than 50m complete all as specified directed by Engineer-in-Charge. Note: The item will be measured in span length between poles. The approx span length is 50m.
Material and labour for Surface dressing not exc 15cm deep in any type of soil and site clearance including cutting and removing of plants/bushes, leveling of surface area, throw wastage material out of fencing area/ compound wall up to 50m distance at sub station areas / pump House areas complete all as specified and as directed by Engineer-in-Charge.
M/s JS Constructions
ROHIT ENTERPRISES
FTH Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .