| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.7 L+₹35,800.65 (1.86%)Rejected-Finance | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹19.9 L+₹58,512.20 (3.03%)Rejected-Finance A 91 DEFENCE COLONY AGRA CANTT AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance Being higher bidder | |
| 4 | L4₹20.2 L+₹90,417.15 (4.69%)Rejected-Finance 142 JAGJIVANRAM NAGAR GAROBA MAIDAN NAGPUR 440008 | NAGPUR | NAGPUR | MAHARASHTRA | 440008 | L4 | Rejected-Finance Being higher bidder | |
| 5 | L5₹20.5 L+₹1.2 L (6.05%)Rejected-Finance | L5 | Rejected-Finance Being higher bidder |
Tender Value
₹24.3 L
EMD Value
₹48,600
Closing Date
29 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE(AF) Agra
HQ CWE (AF) Agra PIN 282008
UPGRADATION OF BUILDING NO P-30 AT AF STN SONEGAON
2023_MES_616829_1
80023-13/E8
Open Tender
Civil Works
Item Rate
180 days
AGE(I) Air Force Sonegon
As per Tender documents
9 documents required · 9 mandatory
₹500
AGE (I) AF Sonegaon Nagpur
₹48,600
Yes
12 Dec 2023
1 Sept 2023
6 Oct 2023
1 Sept 2023
29 Sept 2023
15 Sept 2023
Amount
Taking down existing roof treatment including cleaning and removal from the premises to a distance exceeding 1 KM but not exceeding 1.5 KM complete all as directed.
Dismantling of false ceiling (Fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillets including removal from premises of MOD land complete all as directed.
S& F gypsum ceiling board for ceiling prepainted perforated finish 600X600X9 mm thick in size of approved brand/make, laid over and including grid work of size 605X605 mm , made out of 0.5 mm thick GI tee 32X24 mm for main, 25X24 mm fro cross tee and 24X24 mm angle fixed on wall, powder coated finish on expossed faces of tee and angle, hung from ceiling using 2mm dia GI suspension wire fixed with adjustable clip spaced at 1200 mm on main runners including making niches for fan/light complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L for 10 mm thick cement plaster in CM (1:4) for backing of tiles complete all as specified and directed.
M&L for 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M&L for 10 mm thick plaster in vertical surfaces such as skirting/Dado with CM (1:4) complete all as specified and directed.
M&L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.30 sqm, but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed
Taking down chowkhats or frame exc 4.0 Sqm each with shutter (without taking of shutter from framed) complete including removing from site complete all as specified and directed.
Taking down chowkhats or frame exc 1.50 Sqm but n.exc 4 Sqm each with shutter (without taking of shutter from framed) complete including removing from site complete all as specified and directed.
M & L for powder coated anodised aluminium (sliding/hanging type) windows/ventilator with three track bottom track size 92 X 29.5 X 2mm thick, side & top track frame size 92 X 29.5 X 2mm thick and shutter aluminium anodised 39 X 20 X 2 mm thick incl necessary aluminium fittings like jointing cleats, glazing cleats, rubber packing, anodised aluminium snap beading, screws etc with 5mm thick tinted/plain glass in panels including all fittings & fixture complete all as specified and directed. . Note: Net Opening will be measured lor payment purpose.
Supply only 5 mm thick itched quality glass complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Demolition of plain cement concrete in ground floor and paving not exceeding 15cm thickness below or above ground level including removal of up to a distance exceeding 1 KM but not exceeding 1.5 KM complete all as specified and directed.
Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings,heads,shoes,bends,swan-necks,etc and removing from site complete all as specified and directed..
M&L for brick work with flyash bricks straight or curved on plan to any radius in half brick wall built in CM (1:4) complete all as specified and directed.
M&L for brick work with flyash bricks, straight or curved on plan exc 6 m mean radius built in CM (1:6) complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:6) on wall finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:4) with using WPC on wall finishing the surfaces even and smooth without using extra cement complete all as specified and directed. Note ; WPC shall be measured seperetly.
M&L for 10 mm thick cement plaster in cement mortar 1:3 for ceiling, finished even & smooth without using extra cement complete all as specified and directed.
M&L for applying two coats of synthetic enameled paint on old painted wooden surfaces of any description not otherwise described over 10cm width or girth including preparation of surface complete all as specified and directed.
M & L for applying three coats of white wash on newly plastered surfaces on wall after preparation of the surface, complete all as specified and directed.
M & L for applying three coats of white wash on newly plastered surfaces of ceilings after preparation of the surface, complete all as specified and directed.
M & L for preparation of old decorated surface of walls by brooming down and wire brushing etc and applying one coat of white wash on wall complete all as specified and directed.
M & L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash to ceiling complete all as specified and directed.
M&L for preparing the new plastered surfaces of wall and applying two coats of cement based paint complete all as specified and directed.
M&L for preparing the old surfaces by complete removel of existing treatment and applying two coats of cement based paint on walls complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel l mm thick kitchen or laboratory with plugs, washers and wastes; including dding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm and including 38/40mm dia waste pipe complete all as specified and directed.
M&L for repairing on chajjas not exceeding 60cm width with 10mm thick rendering in CM 1:3 after removing cracked plaster and concrete including cleaning of viisible reinforcement and treating with cement slurry ,including repair to cracked concrete if any with cement concrete 1:2:4 Type B-0 using 12.5mm graded stone aggregate with and including necessary scafolding work for double/single storey bldgs complete all as specified and directed.
M&L for Machine cut cudappah stone slab 20-25mm thick over 15 mm thick screed bed or bedding layer in CM (1:6) cement , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for granite stone of any type tiles 20mm thick over 15 mm thick screed bed or bedding layer in CM (1:6) cement as in steps,jambs,pillars, cooking platforms,and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for rounding to edges of stone slabs one edge as in steps, cooking platform, and other similar location complete all as directed.
Demolition of stone slabs laid bedded and pointed in any cement mortar including bedding (but not backing) of any description or thickness in floors/skirting, aprons etc and removal of rubbish/debris from premises of MOD land complete all as specified and directed.
S&F PVC (SWR) bends 110 mm bore of any radius complete all as specified and directed.
M&L for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls with PVC clamps fixed to wall properly complete all as specified & directed.
S&F in repairs stack clamps out of 100 mm X 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
M&L for preparation of old plastered surface and applying two coats of oil bond distemper white or any tint over a coat of primer after preparation of wall surface with wall Putty complete all as specified and directed.
M&L for preparation of old steel surfaces of any description over 10 cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a redoxide primer etc complete all as specified and directed.
S & F in repair 15 mm dia pillar taps, fancy type , chromium plated, screwed down high pressure with long screwed shanks and fly nuts, serewed for iron pipe & fixed complete all as specified and directed.
S&F 15 mm bore tubes, medium grade' galvanised, with all fitting as socket, elbow,nipple,union etc and fixed complete to walls and ceilings or laid in floors etc complete all as specified and directed.
All as per item No 43 above but for 20 mm dia complete all as specified and directed.
M&L for steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410-W (Gde-E- 250) quality-A complete all as specified and directed.
M&L for compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc.Fe-410-W(Gde-E-250)quality-B complete all as specified and directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-W (Gde-E- 250) quality-A complete all as specified and directed.
S &F mild steel screw bolt,16 to 20mm dia machine made with hexagonal head at one and screwed the other or screwed bolts each screwed and to be filled with washer and one hexagonal or square nut exc 10cm but n exc15cm long complete all as specified and directed.
M & L for preparation to new steel surfaces of any description over 10 cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a redoxide primer etc. complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed .
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Demolation of cement concrete unreinforced on roof /terrace including plastering not exceeding 15 cm thick (below or above G.L) complete all as specified and directed .
M & L for plain cement concrete 1:2:4 type B-0, (using 12.5 mm graded stone aggregate) in roof kerbs, mud stops, rounded or chamfered on edges complete all as specified and directed .
M & L for cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed .
M & L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed .
M&L for screed bed 10 mm thick in cement mortar 1:3 on roof/terrace /parapet wall or concrete surfaces finish even and smooth without using extra cement with WPC @ 3% by weight of cement complete all as specified and directed .
M&L for Applying bitumenous primer @ 0.30 ltr per sqm including cleaning roof surfaces by wire brush complete all as specified and directed .
M&L for Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm including cleaning surfaces complete all as specified and directed .
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface of roof /terrace and parapet wall by torch application method and joint seald properly and location of drain pipe to be treated properly . Overlaping shall be 100 mm on length and width both side of APP membrane and as per manufacturers instruction complete all as specified and directed . Note: Water ponding for 24 hours to be carried out after laying of APP membrane sheet.
M & L for Applying two coats of solar reflective bitumenous aluminium paint on APP membrane fixed on roof including cleaning existing surfaces complete all as specified and directed .
Taking down carefully copper/aluminium point wiring any type ,surface/concealed/ PVC capping or tubing ( including light,fan,s/socket, or power) complete including fixtures and fittings such as switches,ceiling rose,pendents,regulators,sockets etc complete all as specified and directed.
Taking down old unserviceable main switch board, DB of any type and capacity from its location with accessories MCCB's/MCB SP/SPN/TPN complete all as specified and directed.
Taking down old unserviceable tube light/CFL light/recessed mounted light or any type of light fittings complete all as specified and directed.
Taking down old unserviceable Sub Main wiring any type any capacity including conduits from its location & making good of distrube surface complete all as specified and directed.
Taking down old unserviceable surface mounting fixed cable 3.5 core16/35/50/70 sqmm or any capacity complete all as specified and directed
M & L for PVC concealed conduit point wiring with 1.5 sqmm single core 1100V grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including MS pressed steel shet sunk box with 1.2 mm thick ISI marked laminated bakellite sheet fixed with cromium / nicckel plated screws and washers for switches and sockets, including 1.5 sqmm single core 1100v grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduiting and making good disturbed surface area with cement mortar 1;4 and white wash/colour wash to matching with the existing colour and complete all as specified and directed for the following;-
One light point controlled by one switch complete all as specified and directed
One Exhaust Fan controlled by one switch complete all as specified and directed
One three pin 5 Amps switch socket outlet on independent board complete all as specified and directed
One three pin 5 Amps switch socket outlet on same board complete all as specified and directed
All as per item No 67 above but point wiring with 2.5 sqmm multistrandard copper cable for 5 pin 15 Amp switch socket combination on Independent board with one run of 2.5 sq mm multistranded copper cable green colour for earth continuity conductor complete all as specified and directed.
S&F switch piano, flush type single pole,5 Amps, 240 Volts AC complete all as specified and directed.
S&F ceiling rose surface backlite, 65x50mm, three terminals, 5 Amps,240 Volts AC complete all as specified and directed
S&F switch socket combination 5 pin,5 Amps,240 Volts, flush type complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin,5 and 15 flush type universal ,240 Volts, complete all as specified and directed.
Supply and fix LED tube light fitting capacity 20 watt fixed on wall/surface / ceiling with all accessories tube,driver,with surge protector complete prewired with multistranded copper cable & connecting to ceiling rose with 3 core ,multistranded flexible copper cable complete all as specified and directed. Make : CGCta No-LDL-20-NW/wipro/CG/Havells/philips/Bajaj.
Supply and fix 36 watt Recess LED perforated single window modern designated enabled by advanced LFD light. It blandes into ceiling plane & maintain uniform luminance across aperture to enhance visual comfort ceiling tile provided with a drop down acrylic diffser suitable for Size 600X600MM ceiling incluiding extra frame for fixing at POP/ Gysum Ceiling mounted version including LED light complete. The 36W system shall be operating at 220-240v AC supply having internal driver. IP20, surge protection 2KV, ambient tempretaur (-) 20 to 45 degree C, frequency 50 to 60 Hz.PF should be greater than 0.95. THD< 10 % . Individual LED should not be visible for glare free output, and connecting upto tube light fitting with connecting up with copper 3 core flexible cord of minimum sisze 1.5 Sqmm size and testing complete all as specified and as directed.
Refixing of cable any size any capacity upto 70sqmm fixed on wall/trench with clamps & saddle properly complete all as specified and directed retrived from item No 66 above.
Supply and fix concealed sub main wiring with two single core cable of 6 sqmm PVC insulated , 1100 volt grade as per IS 694, with multistranded copper conductor in and including rigid PVC conduit (ISI Marked) medium grade including earthing wire of PVC insulated stranded 6 sq mm cable ,chess cutting including 20 mm dia PVC conduit medium grade with lbow,bends,couplers,tee, sucken boxes pressed steel box mounting fitting/junction boxes etc covered the conduit with cement mortor after drawing of electric cables and makig good of distrubed surfaces with cement mortar 1;4 and match with existing shade of wall/roof complete all as specified and directed.
S&F sheet metal enclosure DB 8 way 240Volt with bus bar semi conceled type with necessary connection DB with incoming slot for MCCB as incomer complete all as specified and directed. Make-Legrand,Havells,Indoasian.
S&F MCBs SP 6 Amp 32 Amp with necessary connection in DB box complete all as specified and directed.
S&FMCB SPN 32 Amp with necessary connection in DB box complete all as specified and directed.
Supply and fixing Heavy duty exhaust fan 300 mm sweep steel body, AC, Single phase, 230 volts, 1400 RPM complete with louvers shutters and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan including cutting wall of any type, making hole for fixing of exhaust fan size 300mm sweep (round/squire) and making good surface with cement mortar1;4 rendering, finishing and colouring with existing colour macthing complete all as specified and directed.
S&F Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece including PVC connection 600 mm long with nuts for 15 mm bore pipe for Cold and Hot water (2 Nos) including fixing of Geyser with nut, bolts /fastener ete complete all as specified and directed.
chronicle enterprises
M/s Shrangi Rishi Construction
karambir constructions
M/s Rahul Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .