Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance RZF 13A GALI NO 41A SADH NAGAR 2ND PALAM COLONY PALAM COLONY SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Not Technically at Par. |
| 4 | Rejected-Technical B 67 PHASE 1 AYA NAGAR EXTN NEW DELHI SOUTH WEST DELHI DELHI 110047 UDYAM DL 08 0037051 | SOUTH DELHI | DELHI | 110047 | Rejected-Technical Not Technically at Par. |
| 5 | Rejected-Technical K 60 B SECOND FLOOR LAJPAT NAGAR II NEW DELHI DELHI 110024 | SOUTH EAST DELHI | DELHI | 110024 | Rejected-Technical Not Technically at Par. |
Tender Value
₹16.3 L
EMD Value
₹32,700
Closing Date
21 Oct 2024, 4:00 pmClosed
DGM (EM)
The Ashok Hotel, 50-B, Diplomatic Enclave, Chanakyapuri, New Delhi-110021
Supplying, Installation,Testing and Commissioning of CCTV System at Hotel Kalinga Ashok, Bhubaneswar.
2024_ITDC_210883_1
Engg/EM/CCTV/HKA/24
Open Tender
Electrical Works
Works
210 days
Hotel Kalinga Ashok, Bhubaneswar
As per tender documents
19 documents required · 19 mandatory
₹0
₹32,700
Yes
9 Jan 2025
10 Oct 2024
22 Oct 2024
10 Oct 2024
21 Oct 2024
10 Oct 2024
Amount
SITC of 2.0 megapixel Day/ Night fixed Dome IP IR camera 1/2.7mm CMOS Sensor, having maximum resolution: 30 FPS @ 1080P (1920X1080) HD IR ranges up to 30 mtrs as per the technical specifications and requirement, complete at site as per Direction of Engineer In charge.
SITC of 2.0 megapixel Day/ Night fixed bullet IP IR camera 1/4mm CMOS Sensor, having maximum resolution: 30 FPS @ 1080P (1920X1080) HD IR ranges up to 30 mtrs as per the technical specifications and requirement, complete at site as per Direction of Engineer In charge.
Supply, Installation, Testing & Commissioning of 2MP IP PTZ Camera with following specifications: 1/2.8" CMOS Progressive Scan Sensor, 1920 X 180 @ 20fps - 2.0 Megapixel ,30X Optical Zoom ,H.265 / H.264 ,Smart IR, Visual Distance up to 150m ,WDR, 3D DNR, Dual-ICR, AWB, AGC, BLC ,3 User / Host Levels ,Support TCP/IP, HTTP, DHCP, DNS, RTP / RTCP, PPPoE ,360 Degree endless Pan range ,220 Preset Positions ,Graphical User Interface Menu ,Operating Temperature - -10~50 Degree, 0~95% RHG complete at site as per Direction of Engineer In charge.
Supply, Installation, Testing & Commissioning of 32 Channel NVR which support up to 32 IP Camera , 8 SATA HDD ( Each up to 8TB) ,2 RJ45 10M/100M/1000M network Interface ,32CH 8HDD NVR ,Simultaneous HDMI & VGA up to 4K output, User-friendly GUI/WEB/Client ,1CH Audio IN and 1CH Audio Out ,16CH Alarm IN and 4CH Alarm Out ,AUDIO Parameters, Compression : H.265+ / H.265 / H.264, Record rate: 320Mbps, Bit Rate: 100Kbps ~ 8Mbps Per Channel, Record Mode: Manual, Schedule (Regular, Continuous), Motion Detection, Video Loss, Camera Tamper, Alarm in, Network Function: HTTP, HTTPS, TCP/IP, IPv4, UPnP, UDP, RTSP, SMTP, NTP, DNS, DHCP, P2P, IP Filter, DDNS,802.1X, SNMP & EN / CE / FCC / RoHS / BIS complete at site as per Direction of Engineer In charge.
Supply, Installation, Testing & Commissioning of 6TB Surveillance HDD complete at site as per Direction of Engineer In charge.
Supplying and Laying of UTP 4 Pair CAT 6 LAN Cable in the Existing surface/ recessed steel/ PVC conduit with connection Complete as Required as Direction of Engineer In charge.
Supply, Installation, Testing & Commissioning of armored 06 Core Single mode (OS2) 9/125 Fiber Cable, ITU G.652.D, G.657A1, Outdoor Corrugated ECCS Armor, HDPE (UV) Sheathing, Theoxtropic gel filled OFC cable with 2 Nos steel wire embedded in side sheathing as strengthening member for switch connectivity. Cable should be ROHS compliant and as per ANSI/TIA-568.3-D, Telcordia GR-20, IEC 60794-2/60794-3-10, ISO/IEC 11801, ISO/IEC 24702 complete on surface / recess / in existing pipe / open duct complete etc. complete at site as per Direction of Engineer In charge.
Wiring of circuit/ sub main wiring along with 2x1.5 wire size of FRLS PVC insulated copper conductor, single core cable in surface /Recessed medium existing PVC conduit complete at site as per Direction of Engineer In charge.
Wiring of circuit/ sub main wiring along with 4x1.5 wire size of FRLS PVC insulated copper conductor, single core cable in surface /Recessed medium existing PVC conduit complete at site as per Direction of Engineer In charge.
SITC of 12 Port LIU Complete as required as Direction of Engineer In charge.
Supply, Installation, Testing & Commissioning of LC-LC 9/125μm OS2 Single mode Round Cord duplex, LSZH fiber patch cord having a protective layer of metal braiding for LIU to switch connectivity. Patch Cord should have Blue Jacket with 1000 time mating cycle complete at site as per Direction of Engineer In charge.
Supplying and Fixing of 25 mm size of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit complete at site as per Direction of Engineer In charge.
Supplying and Fixing of 25 mm size, medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit complete at site as per Direction of Engineer In charge.
SITC of Network Switch Managed Layer 2, 8 Port POE with 120 or above watt POE Budget with 2 SFP Port Loaded with minimum 1 SFP as per requirement complete as Direction of Engineer.
Supply, Installation, Testing & Commissioning of 24 Port POE Access Switches with switching capacity of min 56 Gbps, forwarding performance min 41 Mpps, having 24 x 10/100/1000BASE-T PoE (RJ45) with minimum PoE budget of 180W, with 4 x 1G SFP uplink ports. Operating temperature: 0°C to 45°C, complete at site as per Direction of Engineer In charge.
S.I.T.C of Wall Mount Network Racks 9U with accessories like FAN, PDU, Over Point, Cable manager etc. as per requirement, complete at site as Section of Engineer In charge
S.I.T.C Media Converter for Camera as per requirement, complete at site as Section of Engineer In charge
S.I.T.C of UHD LED smart TV with minimum requirements of screen Solution of 3840 X 2160 Pixel, sound output of 20 Watt, refresh rate 50 Screen Size 43", HDMI Port-2 nos., USB 2.0/3.0- 2 nos. with power Consumption of 0.5 W, AC 100-240 V, 50/60 HZ and with one year complete Warranty complete at site as per Direction of Engineer In charge.
Supply, Installation, Testing & Commissioning of Category 6 RJ45 Unshielded LSZH Patch Cord as per ANSI/TIA/EIA 568.2-D and ETL 04-Connector Channel Verified, ROHS Compliant, 24AWG Patch Cord, Diameter 5.8 ± 0.03 mm, 1 Meter, Operating Temperature -10 Deg C to +60 Deg C. patch cord 1 Mtr for Data at Rack Side for Switch to Jack Panel Connectivity complete etc as required for rack side switch to jack panel connectivity complete at site as per Direction of Engineer In charge..
Supply, Installation, Testing and commissioning of PTZ Camera Power Supply 12 volt/ 10 Amp. As per site requirements and Direction of Engineer Incharge.
Supply, Installation, Testing and commissioning of 5 Mtr HDMI Cable for connecting NVR to the screen complete at site as per Direction of Engineer In charge.
Supply, Installation, Testing & Commissioning of 15 U Wall Mount Rack with fans, stationary shelf, 6 Socket PDU, 2 Nos. of hardware pkts. As per site requirements and Direction of Engineer Incharge.
Supply, Installation, Testing and commissioning of PTZ Camera stand as per site requirements and Direction of Engineer Incharge.
Endeavour Power Services (BID ID -758750)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .