Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹40.2 L+₹2.0 L (5.21%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
18 Mar 2022, 6:00 pmClosed
GE AF SRINAGAR
GE AF SRINAGAR AF STATION SRINAGAR 190007
PROVISION OF MT STORE AND SPECIAL REPAIR TO UNDERGROUND ATC BUILDING AT AF STATION UNDER GE (AF) SRINAGAR.
2022_MES_507989_1
GE (AF) - 65/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE AF SRINAGAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) SRINAGAR
₹73,000
Yes
27 Apr 2022
14 Feb 2022
19 Mar 2022
14 Feb 2022
18 Mar 2022
4 Mar 2022
Amount
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out, complete all as specified.
M&L for PCC 1:4:8 type D-2, using 40 mm graded stone aggregate as in foundation footing / mass concrete etc.
M&L for RCC design mix M-30 grade, using 20 mm graded stone aggregate as in foundation, footings, plinth Beam and similar RCC works complete all as specified and as directed by the Engineer-in-Charge.
M&L for RCC design mix M-30 grade, using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels & similar RCC works complete all as specified and as directed by the Engineer-in-Charge.
M&L for RCC design mix M-30 grade, using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts & similar RCC works complete all as specified and as directed by the Engineer-in-Charge.
M&L for RCC design mix M-30 grade, using 20 mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, plinth beams and similar works for rough finished surface complete all as directed.
Use & waste form work to sides of pillars, posts and columns for rough finished surface of concrete complete all as directed.
Use & waste Form work to sides and soffits of floor or roof beams, lintiles cantilever etc for rough finished surface complete all as directed.
Use & waste Form work to soffits of suspended slabs such as roof slabs floor slab landing and similar work not exc 200 mm thick, for rough finished surface complete all as directed.
M&L for steel reinforcement of TMT bars (Fe-500 Grade) 10 mm dia and over cut to length and bent to shape required including cranking bending spirally, hooking end and binding with mild steel wire ( annealed ) not less than 0.9 mm dia or securing with clips all as specified and directed.
M&L for steel reinforcement of TMT bars (Fe-500 Grade) not exc 10 mm dia as in stirrups cut to length and bent to shape required including cranking bending spirally for hOoping for columns hooking end and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 15 mm thick in cement and sand mortar 1:6 on brick work or cement concrete surfaces of walls including finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. .
M&L for Rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete surfaces of walls including finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. .
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash, all as specified.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer, colour and tint as ordered, complete all as specified and directed by Engineer-in-Charge.
M&L for hardcore of broken stones or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface of broken stone or boulders, complete all as specifed.
M&L for 75 mm thick cement concrete 1:4:8, type D-2,(using 40 mm graded stone aggregate) as in Sub base for path / flooring complete all as specified and as directed.
M&L for 100 mm thick cement concrete 1:4:8, type D-2,(using 40 mm graded stone aggregate) as in Sub base for path / flooring complete all as specified and as directed.
M&L machine cut kota stone slab flooring 20-25 mm thick as in floor, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, laid over and including 20 mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in -Charge.
M&L machine cut kota stone slab flooring 18 - 20 mm thick as in dado / skirting, risers of steps laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, laid over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer-in -Charge.
M&L for 75 mm thick PCC type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection laid in bays n. exc. 2 sqm each, finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge.
M&L for Pressed steel frames 125 mm x 60 mm for doors with one or more rebates including necessary fixing lugs, lock strike plates complete, providing mild steel 6 mm dia thresh old bar and filling hollow of frame with plain cement concrete Type C-0, 1:3:6 (using 12.5 mm graded crushed stone aggregate) complete, all as specified.
S&F 30 mm thick factory made flush door shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
S&F 100 mm long extruded aluminium handles, cast type, anodised, complete all as specified.
S&F 150 mm long extruded aluminium handles, cast type, anodised, complete all as specified.
S&F 100 mm long aluminium anodised, barrel tower bolts of extruded section and fixed, all as specified.
S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed, all as specified.
S&F 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, complete all as specified.
S&F 100 mm long butt hinges, medium weight, cold rolled mild steel and fixed, complete all as specified.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, steel peg stay, & hold fast, and glazing bars, dovetailed or welded complete.
S&F sheet glass 3 mm thick, ordinary quality and glazing with oil putty in square or rectangular in section n exc 0.5 Sqm in each pane, complete all as specified.
M&L for galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tack or galvanised wire staples or fixed with nails and wooden beads, complete all as specified and directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
S&F MS work as in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated) of grade Fe-410- W (Gde-E-250) quality-B , complete all as specified & directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, Fe-410-W (Gde-E-250) quality A, all as specified.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, of diameter of neck 5 to 10 mm and of length exc 15cm but n exc 22.5cm, complete all as specified.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, all as specified.
S&F for pre-painted galvaume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in lroof covering / cladding to wall, fixed with self tapping screws all as specified.
S&F pre-painted galvaume aluminium zink coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covelring/cladding to wall, fixed with self tapping screws as specified, complete all as specified.
Surface excavation (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil, complete all as specifed.
M&L for sand cushioning over PCC surfaces, for laying of interlocking tiles, spread rolled and consolidated to gradient as required complete all as specified and as directed.
Material & Labour for machine pressed precast concrete interlocking paver block of approved shape and size of 80 mm thickness, with minimum compressive strength of 40 N / Sqmm (M-40 grade), without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer coating on top surface, with white cement and pigment laid in path / hardstanding complete Note:- Sand screed will be measured & paid seperatly.
M&L filleting in any position and to any shape in cement mortar 1:3 or cement concrete 1:2:4 including all mitres, stops, etc., section of fillet exc 25sqcm but n exc 50 sqcm, all as specified.
Returning, filling in, including spreading, leveling, watering and well ramming in each layers not exceeding 25 cm using excavated soil.
Filling of excavated soil in floor, including spreading, levelling in layers n exc. 25 cm thick, well ramming including watering as required
Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specifed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. and removing from site all as specified and directed.
Taking down cement plaster of any description on brick or stone masonary wall , etc including racking out joints, hacking for key, scrubbing down with water etc, all as specified.
M&L for applying 3 mm thick cement base wall care putty in two coats on plastered surface of wall, and making the surafce even & smooth for reciving distemper / paint of any descreption all as specified & directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over one coat of primer all as specified and directed. Note:- Cement base wall care putty where ever directed will be applied and will be measured & paid seperatly
M&L for Complete removal of existing treatment from Plastered surfaces of walls including scraping down smoke soots, moulds, moss and trading oil and greasy spots etc including cornices, pilasters etc and applying two coats of oil bound distemper over one coat of primer complete all as specified and directed by Engineer-in-charge. Note:- Cement base wall care putty where ever directed will be applied and will be measured & paid seperatly
M&L for complete removal of existing treatment of wall including sides and soffits of beams, fascias, parapets etc and applying two coats of cement base paint over a coat of primer, , complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each complete all as specified and as directed by the Engineer-in-Charge
Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 5 mm thick aluminium camposit pannel of approved coloure & pattern including rubber bead joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt 200 mm size, 100 mm size mortice lock etc complete all as specified and directed. (a) Frame (top & side) section shall of size 101.60 x 44.75 x 2.4 mm ( Section No 14021) (b) Vertical Members of shutter Section shall be be of size 85.00 x 44.45 x 2.00 mm (Section No 19560) (c) Top Members of shutter Section shall be be of size 83.50 x 44.45 x 2.00 mm (Section No 19581) (d) Lock rail (Middle member) of shutter Section shall be be of size 150.00 x 44.45 x 3.00 mm (Section No 19596) (e) Bottom Members of shutter Section shall be be of size 150.00 x 44.45 x 3.10 mm (Section No 19584) (f) Glazing clip for securing glass of shutters shall be be of 0.80 mm thick (Section No 19370).
Note:- (i) Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx A
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed in position
Supply fabricate & fix in position aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) three track window ( two shutters glazed & one shutters wire gauge) with frame, glazed with 4 mm thick tinted glass and, wire gauge with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead joining cleat for fixing in position, concealed type lock for all three shutter, PVC roller etc all as specified below, complete all as specified and directed. (a) Frame (top & side) section shall of size 92.00 x 31.75 x 1.50 mm ( Section No 20831) (b) Frame (bottom) section shall of size 92.00 x 31.75 x 1.50 mm ( Section No 20832)
(c) Top & side Members of shutter Section shall be be of size 18.00 x 40.00 x 1.55 (Section No 20738) (d) Shutter Interlock Section shall be be of size 18.00 x 40.00 x 1.45 (Section No 20737) (e) Bottom Members of shutter Section shall be be of size 18.00 x 40.00 x 1.55 (Section No 20736) Note:- Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx A
S&F aluminium powder coated minimum thickness of power coated 50 micron of approved colour ventilator, partially glazed and partially louvers, outer frame & mullion fabricated with aluminium section of size 82.50 mm x 38.00 mm x 1.50 mm thick (Cat No 20036), half portion glazed with 4 mm thick frosted glass including rubber beading, & glazing clip, half portion louvers of 40 mm wide & 4 mm thick frosted glass. aluminium louver patti, S.S wire gauge 0.36mm dia and 1.40 width of aperture fixed with 25 x 3mm think aluminium strip with screw to upper half portion of ventilator including all fitting & fixture and fixed in position complete. Note:- (i) Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx A
S&F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet, reinforced with M.S. square tube and fixing in opening as per specification & drawing, complete all as specified and as directed.
M&L for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall bw covered with heat moulded plain colour PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and botom rail on either side & as gap insert for tip rail & bottom rails; panelling of plain colour PVC sheet to be fitted in the MS frame weloded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement. suppling and fixing in the frame at site as per specification & drawing, complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including cover fillets, & snap grid etc, complete all as specified.
M&L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre, intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre.
M&L for Providing and fixing Gypsum Board 12 mm thick (water proof) in ceiling fixed with screw or as per manufacturers instructions including necessary jointing and taping, and applying two coat oild bound distemper over one coat primer and 1 mm thick cement base putty complete all as specified and directed by Engr-in-Charge.
Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including rubbish off the premises, all as specified..
M&L 15 mm thick screed or bedding layer in cement mortar (1:4) for laying floor finishes, complete all as specified.
M&L for 10 mm thick rendring / backing coat in cement mortar (1:3) to receive wall tiles, complete all as specified.
M&L for light shed colour vitrified ceramic tiles 10 mm thick (square) polished, area of each tiles n.exc 0.36 sqm in floors etc laid over existing screed bed, set and jointed in neat cement slurry and pointed in white or coloured cement to match.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match, all as specified.
M&L for coloured glazed ceramic tiles in vertical surfaces of size 450 x 300 x 7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified.
Taking up or down steel tubing and connections, 15 mm bore fixed on walls, floors or ceiling etc complete all as specified and as directed by Engineer-in-Charge.
S&F 15 mm bore tubes, 'medium grade', galvanised, with all fitting; ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed to wall / ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, complete all as specified.
Taking up or down steel tubing and connections, 20 mm bore fixed on walls, floors or ceiling etc complete all as specified and as directed by Engineer-in-Charge.
S&F 20 mm bore tubes, 'medium grade', galvanised, with all fitting; ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed to wall / ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, complete all as specified.
M&L for Lagging to pipes 20 mm bore used in external water supply or plumbing all around with 50 mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25 gauge 20 mm mesh complete including taking down of old lagging all as specified and directed by Engineer-in-Charge
S&F in repair sinks with drainage board made of stainless steel 1mm thick for kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm including waste assembly, complete all as specified and directed.
S&F in repair, PVC flexible waste pipe, 32 mm bore for WHB & sink complete all as specified and directed by Engineer in Charge.
Supply and fix in repair white vitreous China wash hand basin (Flat back) of size 550 x 400 mm fixed on and including new brackets complete including, 32 mm size brass chromium plated waste coupling, chain and plug and porcelain stopper, etc complete.
S & F in repairs 15 mm size central hole basin mixer for mixing hot & cold water, cast copper alloy chromium plated with capstan heads, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe including 450 mm long braided connection pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, brass chromium plated Jet spray with one meter long flexible pipe including all connection complete.
Supply only plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as specified, complete all as specified.
S&F in repair PVC low level flushing cistern, valveless, syphonic action type, double push botton, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 32 mm dia of required length and making connection complete complete all as specified.
S&F in repairs for 15 mm size bib taps fancy type, cast copper alloy chromium plated, with capston head, screwed down, screwed for iron pipe or for brass ferrule and fixed, all as specified.
S&F in repairs for 15 mm size angle cock fancy type, cast copper alloy chromium plated, with capston head, screwed down, screwed for iron pipe or for brass ferrule and fixed, all as specified.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm, complete all as specified.
S&F in repairs, 100 mm dia stainles steel chromium plated grating, fixed in position with white cement Complete.
S&F in reapir Toilet paper holder cast copper alloy chromium plated fixed to walls with chromium plated brass screws, complete all as specified and as direted by the Engr-in-Charge
S&F in repair Tubular towel rail stainless steel chromium plated 20 mm dia D-type 60 cm long between flanges, including brackets and fixed to walls, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 75 mm outlet dia PVC floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete.
Supply and fix in repair 500 litres capacity double layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete
Demolition of cement concrete (unreinforced) in ground floor and in paving n exc 15 cm thickness (below or above ground level), complete all as specified.
M&L for rubbur molded glossy finish Chequered cement concrete tiles of size 30 cm x 30 cm x 25 mm thick, in white cement with pigment, set, jointed in neat cement slurry & pointed in coloured cement, as in floors / path / hardstanding, laid over screed bed complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering, and removal of debries from site.
Dismantling timber scantlings in unframed work 40 sqcm and over in section, in any position, all as specified
S&F 0.63 mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, with L-type or J-type or cranked hook bolts, in roofs, walls etc. with grade of zinc coating 275 complete.
S&F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275
M&L for Preparation of new zinc (or galvanised) steel and iron roof surfaces of any description over 10 cm width or girth to receive painting, by coating with mordant solution including washing and cleaning, etc and applying two coat of synthetic enamel paint over one coat red oxide primer in camouflage pattern complete all as specified and directed by Engineer-in-Charge
M&L for Mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe-410- W (Gde- E-250) quality-B, all as specified.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment using Fe-410-W (Gde-E-250) quality A, complete all as specified .
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long & diametre 16 to 20mm, all as specified.
Taking down copper / aluminium point wiring (light, fan, socket & power) complet incl fixtures and fittings such as switches, ceiling rose, pendent holdes, regulators, sockets, lifgt fitting etc and making good disturbed surface of wall, floor etc complete as specified and directed.
Taking down carefully aluminium sub main wiring complete of any type (batten / surface conduit complete and making good disturbed surfaces complete all as specified and directed.
Taking down carefully by unscrewing MCB DBs of any descreption complete sealing the cable end and making good disturbed surface by walls etc.
Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC rigid conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including sunken type pressed steel terminal box of suitable size for modular type switch with cover plate & frame complete. Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green)
All as per item No 105 above but point wiring for one 5 / 6 Amps socket outlet on independent board controlled by one-way switch.
All as per item No 105 above but point wiring for one 5 Amps socket outlet on same board controlled by one-way switch.
All as per item No 105 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
Material & Labour for conceled type point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and drawn and including PVC rigid conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including sunken type pressed steel terminal box of suitable size with laminated white top sheet cover of 3.00 mm thick complete.
All as per item No 109 above but point wiring for one 5 / 6 Amps socket outlet on independent board controlled by one-way switch.
All as per item No 109 above but point wiring for one 5 Amps socket outlet on same board controlled by one-way switch.
All as per item No 109 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
S&F modular one way switch 6 Amp 240 volt marked light / fan suitable for one moduel etc complete as specified and directed.
S&F Modular 6 Amp 5 pin universal socket suitable for two moduel , 250 volts complete all as specified and directed.
S&F modular switch one way 16 Amps 240 volts suitable for one moduel complete as specified and directed.
S&F Modular 6 /16 Amp socket suitable for two moduel , 250 volts complete all as specified and directed.
M&L for Switch Piano type, white polycarbonate body, single pole, one way 6 amp, 230 V, including connecting complete.
M&L for Switch Piano type, white polycarbonate body, single pole, one way 16 amp, 230 V, including connecting complete.
M&L for Socket outlet white polycarbonate body, 6A- 230 V, 2/3 pin combined, including connecting complete.
M&L for Socket outlet white polycarbonate body, 16 A, 3 pin cum 6 A, 3 pin- 230 V, combined, including connecting complete.
M&L for ceiling rose with three terminal as per relevant IS complete as specified and directed
S&F fix in repair lamp holder Polycarbonate body with back plate suitable for batten fitting including connection complete.
S&F 15 Watt LED retrofit lamp fixed to holder complete. Make Havels Cat No LHLDEBUEMD8Z015 or equvallent cat No of make mention Appx A
S&F energy efficient LED tube light fitting with built in LED & integral LED driver 20 watt, channel housing & diffuser of length 1200 mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge.
S&F Energy saving new generation 10 W LED IP 65 bulkhead luminair with opal diffuser etc complete as specified and directed by Engr-in-charge.
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 4 way TPN (VTP), for Single / Three Phase Outgoing, for MCB as incomer, 415 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed.
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 12 way SPN suitable for MCB DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 8 way SPN suitable for MCB DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed
S&F epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 2 way SPN suitable for MCB DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting complete all as specified and directed
S&F MCB single pole ISI marked ISI Marked `C' series working on 240 Volts 50 HZ AC supply for incomming and out going controlling cercuit of capacity 6-32 Amp breaking capacity 10 KA etc all as specified and directed.
S&F MCB single pole and neutral ISI marked `C' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 32 Amps 10 KA breaking capacity etc all as specified and directed.
Supply and fix heavy duty, metal body, exhuast fan 300 mm sweep, 900 RPM, single phase, 240 Volt, 50 Hz, with all accessories as per manufacturer norms fixed in position and connecting, including taking down old fan and deposited in MES store yard complete as specified and directed by EIC
Supply and fix heavy duty, metal body, exhuast fan 450 mm sweep, 900 RPM, single phase, 240 Volt, 50 Hz, with all accessories as per manufacturer norms fixed in position and connecting, including taking down old fan and deposited in MES store yard complete as specified and directed by EIC
Supply and fix storage type water heater 5 star rated, 25 liters capacity vertical wall mounting type made out of CRCA outer body, stainless steel storage tank, titanium enameled heating element, thermostat, thermal cutout, glass wool, fixed in position with and including GI fasteners of size M-10, as per manufacturer's instruction, & writing the MES No etc complete as specified and directed by EIC .
Supply only Fiber reinforced PVC flexible pipe(Flexi connection pipe), heavy duty size 450 mm long 15 mm bore with brass chromium plated nut on both end, with rubber washers.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling, complete. Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
Material and labour for renewal earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Note:- Quoted rates shall be deemed to include for earth wire with protection pipe up to 7.5 M length.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade of size 16 Sqmm, 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed. Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
Supply and Laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks complete all as specified and directed by Engineer-in-Charge.
S&F in repair 50 mm dia bore mild steel galvanized iron tubes, 'light grade' with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable complete all as directed.
M&L for cutting existing 20 mm bore GI tubing for making new connection for 15 mm pipe including provision of 20 mm size union, 20 x 15 mm reducer T complete all as specified
S&F 15 mm bore tubes, 'medium grade', galvanised, with all fitting; ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) laid in trenches including screwing and waste and for forged bends on piping as required, complete all as specified.
S&F 75 mm bore, HDPE Double Wall Corrugated Pipe in any length with rubber ring joints, laid in trenches or fixed on wall with clamp for protection of cable etc complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of Early Streamer Emission Lightning Protection system (Creates an upward stream to neutralise the lightning stroke above the building and hence protect the building, 79 meter radius of protection at Level-I protection (very high protection) complete with all fixing accessories as required, Device confirming to NFC 17-102 & 21186 standards Make:- SGI model No ESE Taran or equivalent of make approved by GE
Supply & fix 50 mm bore and 5 meter long mild steel galvanised iron tubing heavy duty as in post / Mast for fixing / installation of lighting protection system, cut to size and errect in true verticle position including necessary foundation by excavation in any type soil, PCC 1:4:8 for foundation, brick masonary work in CM 1:4, returning & filling & removal of surplus soil complete as specified & directed.
Supply, installation, testing and commissioning of lightning transient event counter non resettable type 6 digits mechanically display having IP65 rating enclosure, mounting arrangement etc. as required manufacture norms etc complete as specified and directed. Make:- SGI model No ESE Taran or equivalent of make approved by GE
S&F Oblong test link joints to Discount the earth pit for testing etc complete as manufacture norms and specified and directed. Make:- SGI model No ESE Taran or equivalent of make approved by GE
Supply and laying XLPE insulated PVC inner sheathed, un-armoured heavy duty underground cable with copper multi stranded conductor 1100 volt grade of size 70 Sqmm, single core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete.
Supply, install and erect in true vertical position steel tubular swaged welded poles complete with MS base plate of 6 mm thick of size 300 mm x 300 mm, B 118 finial taper plug, pole cap, bolts, nuts and washers and screwed, pole made out of ERW MS tubing conforming to IS-2713 Part II, type 410-SP-22 ( 8.5 meters long) L.T poles including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of black bituminous paint for portion embedded in concrete, painting three black / red / bands at lower portion of pole each of 300 mm height at 300 mm spacing, painting pole No with black paint at suitable height, complete all as specified and directed.
Note - Excavation & PCC for foundation & coping will be measured & paid separately.
Material and labour for installation, testing and commissioning of maintinance free chemicle tripod earthing using following material including necessary T&P required to complete job for earthing excavation etc for Make:- SGI Engineers Pvt Ltd, Powertrac, PRAGATI / McML’s Earthing Solution (MES) / Ashlock
(a) 3 Nos Earthing Electrode of 17.2 mm dia and 3 meter long solid copper rod. (b) Placing & fixing of all three earthing rod by boring 3 Nos, 100 dia bore, 3 metre deep in any type of strata, returning filling bore after placing the rod with soil mixed with 25 Kg Earthcon & 5 Kg Terec+ compound all as per manufacturer instruction. (c) FRP Earthing chamber cover ,earthing pit, as per manufacturer instruction complete. Note:- Interconnection between electrode will be measured & paid separately.
M&L for cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate as in coping of pole and the like, weathering, slightly rounded or chamfered angles including necessary form work complete.
M/S Abdul Ahad Rather
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .