Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC H NO 19 6 243 1 NGO S COLONY SHIV NAGAR NORTH BIDAR 585401 | BIDAR | KARNATAKA | 585401 | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.5 L+₹6,185 (0.36%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹18.0 L+₹55,130 (3.17%)Rejected-Finance | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹19.7 L+₹2.3 L (13.4%)Rejected-Finance | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹21.4 L+₹4.0 L (23.1%)Rejected-Finance | L5 | Rejected-Finance Not L1 |
Tender Value
Refer Docs
EMD Value
₹37,000
Closing Date
27 Mar 2021, 6:00 pmClosed
GE (AF) Hakimpet
GE (AF) Hakimpet Secunderabad-14
SPECIAL REPAIRS / REPLACEMENT OF BER ACs AND AIRFIELD MAINTENANCE LIGHTING AND PROVN OF GEYSERS AND CONNECTED WORKS AT PUNDIR BLOCK OF NO 2 OFFICERS MESS AT AFS HAKIMPET UNDER GE(AF) HAKIMPET
2021_MES_426344_1
8281/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HAKIMPET
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) HAKIMPET
₹37,000
Yes
1 Apr 2021
27 Feb 2021
29 Mar 2021
27 Feb 2021
27 Mar 2021
13 Mar 2021
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in hard/ dense soil for carefully taking out the existing cable inlcuding PCC cable covers(for re-use) and for laying of runway lighting cables Note: (i) Replacement of cables and Isolation Transformers will be under taken by AFS Hakimpet (ii) Re-laying of removed PCC cover shall be taken separately under "Laying Obly " item.
Supply and spread fine river sand in trenches for cushioning of cables complete all as specified and directed.
Laying only PCC cable cover of size 300mm x 180mm x 40mm or as retrived against item No 01. (Cable covers removed under item No. 1 shall be re-used)
Returning, filling in excavated hard/dense soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
Removing excavated hard/dense soil not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and Labour for Cable jointing kit for 3.3 KV grade cable for straight through joint complete with jointing material and accessories suitable for single core unarmoured multi-stranded copper conductor cable of size upto 16 sqmm, complete all as specified and directed.
Material & labour for concealed point wiring by using 2.5 Sqmm PVC insulated unsheathed copper conductor multistrand drawn in new terminal sunkon boxand provn of PVCrigid non metallic conduit medium density ISI marked fixed with all fittings and all accessories i.e 3 mm thick plastic laminated sheet for mounting of switches and socket complete for one light/fan point controlled by one switch including provn of 1.5 sqmm PVC insulated copper conductor continus asearth wire connected to earth dollycomplete all as specified and directed. Note:- Switches, sockets etc shall be measured and paid seperately in an appropriate Item of Sch'A'.
S&F Stop Valve 15 mm, cast copper alloy, screwed down, high pressure with crutch complete all as specified and directed.
S&F GI Tubing 15 mm medium with all fittings, laid in trenches, floor/wall, complete all as specified and directed.
S&F PVC connection 15 mm size with PTMT nuts of length 300 mm, complete all as specified and directed.
S&F Bib Tap 15 mm, cast copper alloy, screwed down, high pressure with crutch, complete all as specified and directed.
S&F Water heater storage type(Geyser), electric driven capacity of 25 Ltrs capacity of rating 5 star including all necessary fixing arrangements, complete all as specified and directed. Make:Havells Cat No.GHWAMGTWH025 / Racold Cat.Buono Pro
M&L for fixing of 15 A plug 3 pin, complete all as specified and directed.
Dismantling of wall mounted split units indoor & outdoor complete or window type aircondioners of any capacity and deposted to store of AGE E/M Hakimpet, complete all as specified and directed.
Supply, installation, connecting, testing and commissioning of wall mounted Split AC units indoor & outdoor complete with cordless remote control unit, with inverter technology of capacity 1.5 TR, 5 star adjustable, inclusive of suction and discharge lines of suitable size and length of copper tube including necesary brazing and providing nitrile tubing over gas circulating copper tubes and neatly tying the ends with PVC insulating tape and mounting on suitable bracket inclusive of suitable drain pipe for disposal of waste water upto ground level, including cutting holes in to stone/brick walls built in cement mortar or cement lime mortar and wall of cement concrete not exceeding 150 Sqcm area of holes for running copper tubes from indoor to outdoor split unit and testing, neatly finishing the disturbed surfaces of walls to match with the surroundings, complete all as specified and directed. Make:Lloyd Cat No.GLS18152WBEL/ Blue Star DATX Cat Part No.IC518LBTU
SRI SAI RAM ENTERPRISES
Saiansh Associates
SREE KIRAN ENGINEERS
Srinivash Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .