Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC 23 6 C LAL VIHAR EAST END BAMRAULI PRAYAGRAJ 211012 U P | PRAYAGRAJ | UTTAR PRADESH | 211012 | L1 | Accepted-AOC Pl deposit Perf Security | |
| 2 | L2₹32.4 L+₹8.6 L (35.9%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹36.1 L+₹12.3 L (51.7%)Rejected-Finance 83 5M 1 SHIV GANGA PURAM YADAVPUR ROAD UMARPUR NEEWAN PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
24 Oct 2024, 6:00 pmClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
REPAIR OF PATH, HARD STANDING, DRAIN, CULVERTS SECURITY FENCING, BOUNDARY WALL AND CLEANING MAINTENANCE OF SEWAGE LINES MANHOLES SEPTIC TANK INCLUDING SANITARY FITTINGS AND OTHER CONNECTED WORKS IN SOUTH CAMP, 4 AFSR, MAP, TEACHER COLONY, TECH AREA A
2024_MES_658113_2
8889/E8
Open Tender
Civil Works - Others
Works
180 days
GE (AF) Bamrauli
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Bamrauli
₹80,000
Yes
23 Nov 2024
30 Sept 2024
26 Oct 2024
30 Sept 2024
24 Oct 2024
7 Oct 2024
Amount
Demolition of cement concrete of any description and in any position not other wise specifically provided for complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, Arches etc and removal of debrishes from site complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radious, built in cement mortar (1:6) complete all as specified and directed.
All as per item No. 3 above but except bricks (Bricks shall be obtained from demolition. Rates for segregation of old bricks, stacking, cleaning etc. shall be included in this item.)
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 M mean radius built in CM (1:4) complete all as specified and directed
Ditto all as per Item No 5 here-in- before but except bricks (using old serviceable bricks)
Taking down cement plaster of any description including racking out joints, hacking for key, scrubbing down with water etc and prepare to receive new plaster complete all as specified and directed.
M&L for 15 mm thick rendering in CM (1:4) on external surface fair/other than fair faces of brick wall finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for 15 mm thick rendering in CM (1:4) on external surface fair/other than fair faces of brick wall /concrete surfacefinished even and smooth without using extra cement etc complete all as specified and directed with mixing of WPC @ 3% by weight of cement or as per manufacturers instruction.(Note : WPC shall be measured and paid seperately as supply only under respective items of this Schedule)
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Non Skid ceramic coloured tiles 300mmx300mmx 7 to 8 mm thick(square/ rectagular) joint free as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing shade tile laid over and including 15mm thick screed bed layer in CM (1:6) etc complete all as specified and directed.
M&L for Glazed ceramic coloured tiles in vertical surface 350 x250x 7 mm/ 450x 350x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade tile including 10mm thick rendering in CM (1:4) complete all as specified and directed.(Premium quality).
Supply only Intergral water proofing compound.
M&L for Keyed pointing in cement mortar (1:4) to brick wall of drains complete all as specified and directed.
M&L for PCC (1:4:8) type D-2(using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete, complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in surface channel and drain finished surface even & fair complete all as specified and directed.
M&L for Extra for forming fair finished drain or channel 30cm inner girth in cement concrete with using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed. (inner girth only measured)
Add or deduct from item No. 17 for each 25mm girth or part thereof over or under 30cm inner girth (inner girth only measured).
M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in beching and coping, bed block lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
Dismantling of mild steel or structural steel work including doors, gates, but excluding framed truss and dismantling of CI work and removing complete all as specified and directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shoulders or reveted, forged into spikes, framed guard bars, railings, ladders and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
All as per ser item No 21 above but fixing only
Demolition of reinforced cement concrete of any description and in any position as in ground foors all as directed by Engr-in-Charge
M&L for Reinforcement cement concrete pre-cast reinforcement cover slab (1:2:4) type B-1 using( 20 mm graded crushed stone aggregate) as in manhole cover of any size including RCC ring/Frame and MS frame set in CM (1:4) etc complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Dismantling Stone slabs and tiles of any description or thickness in floors aprons etc laid dry or laid dry and pointed complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block of grey cement rubber moulded glossy finish and no pigment, any shape and size confirming to IS-15658-2006 of 80mm thickness, M-40 grade laid over and including 30mm thick sand cushion complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block of grey cement rubber moulded glossy finish and no pigment, any shape and size confirming to IS-15658-2006 of 60mm thickness, M-35 grade laid over and including 30mm thick sand cushion complete all as specified and directed.
All as per item No 28 above but fixing only.
M&L for preparation of new concrete/brick/stone or plastered surface of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer etc complete all as specified and directed.
M&L for Preparing new plastered wall surfaces and applying Two coats of cement base paint on wall surfaces over one coat of primer complete all as specified and directed.
M&L for Preparing, plastered or unplastered of old plastered surfaces of walls and applying one coat of cement base paint complete all as specified and directed.
De-silting and cleaning of existing rain water drain and removing the earth / sand / silt and shrub and other materials etc complete to a distance exc. 250 m but n. exc 500 mtr and depositing where directed at a level n. exc. 1.5 m above the starting paint complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground
S&F for mild steel work as in posts or struts in fencing including cutting tops to shape as directed ,drilling holes, notching for wire etc flat iron fillets (for securing wiremesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Ditto all as per item No 35 above but fixing only
M&L for two coats of synthetic enamel paint on new steel surfaces of any description over and including a coat of red oxide primer including preparation of steel surface complete all as specified and directed.
M&L for preparation of old steel surfacses of any description and applying one coats of synthetic enamel paint etc complete all as specified and directed.
S&F in repair for galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining fixing to any type of strandard rail straining bolts,including securing or tying at crossing with provision of galvanised mild steel wire, staples or steel pins etc as directed (each line wire to be measured)
Ditto all as per item No 39 above but fixing only
S&F in repair chain link mild steel galvanized fencing of mesh size 50mmx50mm and not less than 3mm dia hot dipped GI wire fixed and binding with GI wire complete all as specified and directed.
M&L for Cleaning and clearing of underground sewage line (including manholes by taking off manhole covers and re-fixing the same after cleaning) of any description underground any depth by removing any type of blockage including de-silting and de-chocking manually by providing rodding and flushing after cleaning including clearing of manholes and as directly by Engineer-in-Charge, from the following size/bore of sewage lines :-
(a) Upto 150mm bore pipe.
(b) Exceeding 150mm bore but not exceeding 300mm bore pipe.
Material and labour for cleaning of blockage manually by rodding, pumping etc and removing the deposited sludge/solid/liquid material, outside MOD land, complete all as directed from the following :-
(a) Water Closet (Indian or European), trap & CI pipe line upto first Manhole.
(b) Floor/Nanhi trap of Kitchen/Bathroom upto gully trap (excluding gully trap).
(c) Gully trap upto first Manhole.
Excavation in soft/loose soil for getting out puncturing or existing damaged/broken or otherwise nonfunctional salt glazed stone ware pipe 100mm dia bore (length of pipe 60cm) and supply and fixing salt glazed stone ware pipe of 100mm dia bore grade 'A' ISI Marked incl PCC 1:3:6, Type C-2 bed and haunching as required incl jointing with existing line, returning, filling in and well ramming the soil and removal of surplus spoil to a distance n. exc 50 mtr and deposited where directed etc complete all as specified.
Ditto all as per item No 45 here-in before but bore of pipe 150mm
Excavation in soft/loose soil for getting out puncturing or existing damaged/broken or otherwise nonfunctional RCC drain pipe (one peace) 300mm dia bore and supply and fixing RCC drain pipe 300mm bore class NP-2 with collars etc complete incl PCC 1:3:6, Type C-2 bed and haunching as required incl jointing with existing line, returning, filling in and well ramming the soil and removal of surplus spoil to a distance n. exc 50 mtr and deposited where directed etc complete all as specified.
Dewatering of septic tank and manholes any size and cleaning by taking out sludge from septic tanks and monholes of any depth, in foul conditions and confined places, getting out and removing the sludge to a distance exc 250m and n. exc 500m and deposited where directed in and including borrow pits and covering the borrow pits with 20cms thick layer of soil complete all as specified and directed.
S&F (in repair) vitreous china squatting pan Orissa Pattern size 580x440mm white with integal foot rest (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe complete including trap, set with cement concrete complete all as specified and directed.
S&F in replacement vitreous china wash down water closet (pedestal pattern) white (excluding flushing cistern and flush pipe) including plastic seat cover and making good the floor with adjacent floor finishing and making connection to flush pipe etc complete including making functional and removal rubbish/waste materials to a distance n.exc 50m etc complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan (one piece type) ivory with PVC sheet cover & flushing cistern, flushing pipe), including making good the floor with adjacent floor finishing and making connection to flush pipe etc complete including making functional and removal rubbish/waste materials to a distance n. exc 50m, complete all as specified and directed.
M&L for Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device as in repair complete all as specified and directed.
S&F in repair 10 liter PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flush pipe and 600 mm long PVC connection complete all as specified and directed.
S&F in repair vitrous china urinal, bowl type of size 410x355x265mm(back or corner wall type),complete including providing and fixing plugs,bedding urinal against walls in ceemnt mortar 1:2,securing urinals to plugs with and including 60mm long brass screws,pointing around urinal backin cement,fixing automatic flushing cistern with brackets,flush pipe grating and union for discharge pipe(exclusive of fixing supply pipe to flushing cistern,trap and waste pipe compete
M&L for cutting into existing manholes of internal dia 100mm for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for internal dia of pipe 150mm complete all as specified and directed.
All as per item No 55 here-in before but internal dia of pipe 300mm
S&F for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. .
Taking down eaves gutters and rainwater pipes (any size or pattern) , including all fittings, heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories).
M&L for 100mm dia Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
M&L for 75mm dia Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
S&F in repair 100mm dia Cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) etc complete all as specified and directed.
S&F in repair 75mm dia Cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) etc complete all as specified and directed.
S&F in repair 100mm dia Cast iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors etc complete all as specified and directed.
S&F in repair 75mm dia Cast iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors etc complete all as specified and directed.
S&F PVC (SWR) 75mm dia pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC (SWR) 110mm dia pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F for 110mm bore PVC soil waste/Vent pipe in any length with or without ears with cement joints laid in trenches or in floors complete all as specified and directed. (Excavation and earth work shall be measured and Paid separately).
All as per Item No 67 herein before but 75mm bore of pipes
S&F for 75mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F for 110mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F for 75mm dia PVC (SWR) junction single, (Single T) equal or unequal with access door etc. complete all as specified and directed. (in Repair)
S&F for 110mm dia PVC (SWR) junction single, (Single T) equal or unequal with access door etc. complete all as specified and directed. (in Repair)
M&L for repairs to sunken portion/floor including demolition of existing PCC,WC,P/S Trap and removing the material outside MD land and cleaning with the wire brush to dry and applying one coat of URP in cement in ratio 1:1 @ 1liter per Sqm. After drying of this process applying two coats of pidifin2K @ 01 liter/Sqm for two coats and minimum time gap between each coat is 4 hours and 15 mm thick rendering in CM 1:4 including finished even & smooth without using extra cement complete all as specified and directed. Notes:- (a) Area of measurement will be floor area which includes side walls of the sunken portion (a) The pidifin2k chemical treatment shall be carried out by authorized technicians of Dr Fixit (b) 10 years written guarantee (from the certified date of completion of work) shall be obtained from the Dr Fixit and submitted by the contractor.
M&L for cement concrete type E2 1:5:10 (40mm graded stone aggregate) as lean concrete in filling / Mass concrete complete all as specified and directed
Excavating in trenches soft/loose soil n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out complete all as specified and directed.
Excavating in trenches soft/loose soil n. exc 1.5m wide and exc 1.5m in depth but n.exc 3 meter ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and exc 1.5m but n.exc 3m in depth and getting out complete all as specified and directed.
Returning filling in soft /loose excavated soil including spreading leveling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing surplus excavated soil/earth to a distance not exc.50M and deposited where directed at a level not exc.1.5 M above the starting point.
M&L for salt-glazed stoneware drain pipe grade 'A' 100mm bore, ISI marked, jointe with cement mortar, laid in trenches and tested including fittings of same grade complete all as specified and directed.
M&L for salt-glazed stoneware drain pipe grade 'A' 150mm bore, ISI marked, jointe with cement mortar, laid in trenches and tested including fittings of same grade complete all as specified and directed.
M&L for concrete bed (40mm graded stone agg) to drain pipes 100mm dia including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C2 using complete all as specified and directed.
M&L for concrete bed (40mm graded stone agg) to drain pipes 150mm dia including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C2 using complete all as specified and directed.
Cleaning of sewage lines of 100mm dia. by roding from manhole to manhole removing the materials obtained from sewage line including cleaning of manholes and flushing with clean water complete all as directed.
Cleaning of Septic tanks of 150 uesrs capacity by dewatering all the water, taking out the sludge/night soil, in order to remove all stacked mud/sludge etc., cleaning the chocked inlets, outlets of septic tanks, removing all the sludge outside MD land, complete all as directed.
Removing of blockage from 'S' trap/'P' trap/ Nahani trap/floor trap by flushing or by sucking by suction pumps at GF/Ist/IInd/ IIIrd floor including cleaning the line up to 1st manhole complete all as directed.
Clearing the urinal blockage of any length and dia by roding and removing the materials (sludge) to a distance not exceeding 500m all as directed.
Cutting into existing manholes for connecting new drains of internal dia of pipe 100/150/200/300mm etc, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round and 3/4 section) in cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) smooth finished and reforming benching as required complete all as directed.
M&L for plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping, benching etc including necessary form work complete all as specified
M&L for RCC NP3 pipe dia 100 mm bore laid and jointed with collars in cement mortar complete all as specified.
All as per srl item No.101 here-in-before but of 150mm dia
All as per srl item No.101 here-in-before but of 200mm dia
All as per srl item No.101 here-in-before but of 300mm dia
S&F 150x150mm Salt-glazed stoneware gully traps, square or round mouthed, type 'P' including demolition of old/damaged gully trap complete all as directed.
M&L for pre-cast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate) as in cover slabs including necessary from work etc, set in CM 1:6 complete all as specified( form work shall be included in quoted rates), ( reinforcemnt be measured and paid seperately)
M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) of 75mm thick as in Path / PCC floor, finished even and fair including demolishing old cement complete all as directed.
M&L for Chequered cement concrete tiles 30cmx30cmx25mm thick set and jointed in neat cement slurry including 15 mm thick screed in CM(1:6) and pointed in white or colour cement to match with grey cement and no pigment complete all as specified and directed.
M&L for PCC (1:2:4) type B2 (using 40mm graded stone aggregate), 100mm thick, as in hard standing finished even and smooth without using extra cement including demolishing old concrete complete all as directed.
M&L for 75 mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection including making 10mm thick joints filled with bituminous & sand mixture (1:7) not exec 3.00 mt intervals, corners and finished even and smooth without using extra cement including demolishing old concrete complete all as directed.
Cleaning of Rain Water pipes and removing the materials (sludge) to a distance n exc 50m, complete all as directed.
Complete removal of trees/plants growth on bldg's roofs, chajjas, at junctions of pipe line fixed on walls and walls coming on bldgs up to the roots and removing the material (Branches and plants ) to a distance n exc 50Mtr complete all as directed. Note : Work to be carried out up 15mtr height of the bldg.
Cleaning of non accesible Roof/ roof sheeting , sorrounding area mud, tree leaves etc including water outgoing holes at any height of bldg, removing the materials (sludge) to a distance n exc 50m, complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensil strength of 550 Mpa as in roof covering to wall fixed with self tapping screws as specified
Ditto as per item No 118 above but plain sheet as in walls, ridfges etc complete all as specified and directed.
M&L for grating, Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
S&F in repair concertina coil 900mm dia (in stretched position) hot dip galvanized steel wire coated with CLR anti corrosive paint, making diamond shape with the help of dovetail clips (26 SWG) fixed over and including razaor wire, medium barb, hot dip galvanized steel wire razor wire with angle iron. The concertina coil to be fixed with razor wire at points wherever coil touches bottom of razor wire with the help of hog rings (20 SWG) including all fittings like fasteener clips,steel lug rings etc complete all as specified and directed. Note- (i) Stretch length of each coil shall be 6 mtr complete all as specified and directed.
Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface, work in hard/dense soil complete all as specified
M&L for PCC 1:3:6 Type C-2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
S&F (in Repair) Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified including plastic water closet seat closed pattern with flat bottom and cover and mild steel chromiunm plated or aluminum hinging device.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material
M/S SWASTIK BUILDERS (BID ID -3148924)
chauhan construction (BID ID -3149296)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .